AQUADYN Ultrafiltration Modules Smarter Solutions for Water Treatment

Similar documents
BIO-CEL -Modules. The Solution for state-of-the-art MBR-Technology. Backwashable - Self-Healing - Mechanically Cleanable

Reverse Osmosis & Nanofiltration Performance & Design Calculations

U-Version. Incoming City Water

MICRODYN-NADIR. MICRODYN isep 500 Ultrafiltration Modules. Product Manual. Product Manual

MICRODYN-NADIR MICRODYN AQUADYN UA860

Ultrafiltration or UF is a pressure driven membrane separation process that. The Omexell UF system utilizes a double-walled hollow fiber (capillary)

Ultrafiltration Technical Manual

Pora. A Host of Latest Water Membrane Technologies

Technical White Paper

MBR MRI BIO-CEL. Ultra-Effective, Ultra-Filtration. MRI Bio-Cel MBR. Meurer Research, Inc Joyce Drive (303) FAX (303)

INNOVATIONS IN ADVANCED MEMBRANE TECHNOLOGIES

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Lenntech THE ART TO CLEAR SOLUTIONS PRODUCTS. Tel Fax

Submerged Membrane Technology for MBR

APC. Ultrafiltration Membranes

Membrane Systems. Featuring Aqua MultiBore Membranes

Reclamation of Sand Filter Backwash Effluent using HYDRAcap LD Capillary UF Membrane Technology

Produced Water Desalination: Science and Solutions

COMPACT PLANTS FOR MUNICIPAL WASTEWATER TREATMENT

The Shell Water purification Unit

Membranes & Water Treatment

DOW Ultrafiltration. Case History. DOW Ultrafiltration Membranes Offer Reliable, Economical Answer to High Solids

Polymeric Hollow Fibre Membrane

DOW Ultrafiltration. Case History. DOW Ultrafiltration Modules Protect Reverse Osmosis System from High Iron

Micro- and ultrafiltration

INNOVATIONS IN ADVANCED MEMBRANE TECHNOLOGIES

Crossflow Filtration for Ink Jet Fluids

Koch Membrane Systems, Inc. Matias Amor Regional Sales Manager. WEX Casablanca Nov 2014

HEAVY INDUSTRY PLANT WASTEWATER TREATMENT, RECOVERY AND RECYCLE USING THREE MEMBRANE CONFIGURATIONS IN COMBINATION WITH AEROBIC TREATMENT A CASE STUDY

Leachate treatment by direct capillary nanofiltration. Hans Woelders Second Intercontinental Landfill Research Symposium Asheville NC, October 2002

F ltrat on. An ISO & ISO Company

new generation membranes clean water for life

Advanced Treatment by Membrane Processes

SPIRA-CEL spiral wound modules

Ceramic Hollow Fibre Membrane

Recent Advances in Membrane Technologies Peter D Adamo, Ph.D., P.E Spring Conference Wilmington, NC April 13, 2015

new generation membranes clean water for life

Keywords nanofiltration; capillary membrane; direct treatment; backflush; surface water.

Make Water Anywhere with Pall Integrated Membrane Systems

FLOW REVERSAL DESALINATION TECHNOLOGY

Pre-Version 05/09. More than Pure Water. Membrane technology. Printed in Germany, PT PM /09 GB

Membrane Technique MF UF NF - RO

MEMBRANE BIOREACTORS (MBR)

UF/MF Membrane Water Treatment: Principles and Design, Dr G K Pearce

Aqua-Aerobic MBR Topics

Water Filtration Applications Using Porous Silicon Carbide Membranes

Some Standard Membranes: Filmtec Membrane, Hydronatics Membrane, Torry membrane and Koch Membrane.

SPIRA-CEL. Lenntech. Instruction manual for SPIRA-CEL spiral wound modules for industrial applications

OsmoBC Integrated Membrane Systems

PedalPure The Portable Ultra-Filtration Water Treatment System

Depth Filtration with Microfiber Cloth Enhances Performance of Ultrafiltration as Pretreatment to Seawater Desalination Systems

Air Connection on Rack. Filtrate Connection on Rack

EMERGENCY WATER. Immediate delivery when emergency response for water and/or waste water is required

Vibro unique filtration devices for micro- and ultrafiltration

Clean water for the world. Innovative technology from the ultrafiltration specialists

Membrane technology past, present and future within the water industry T. Peters*

NANO FILTERING SYSTEM

Water Treatment Technology

Evaluation of MF/UF Technology on the Nooksack River for Drinking Water Production

OLTRE CAP V- SERIES OUTSIDE IN AIR SCOUR ULTRAFILTRATION MEMBRANES

Membrane Bioreactor. Highest level of effluent standards

MEMBRANE SEPARATION. Microfiltration Ultrafiltration Nanofiltration Reverse Osmosis Desalination. Satisfies Your High-Purity Water Needs

Engineering & Equipment Division

Beer Filtration Solutions Your Partner for All Your Filtration Needs

CV GEDE DARMA PUTRA. Head Office Jln. Cihanjuang km 2,5 No.124 Cihanjuang, Parongpong Bandung, West Java, Indonesia. Phone

Basic Design Concepts of MBR

Gregory E. Choryhanna and Alan R. Daza, SEPROTECH SYSTEMS INC. Process Development Division Ottawa, Canada

Fabrication of Reverse Osmosis Spiral Wound Membranes using Local Materials

NEW GENERATION MEMBRANES clean water for life

Engineering, NTUA, 15780, Greece Tel: ; Fax: * Correspondence author

MBRs The Future of Wastewater Treatment PURON MBR. Tim Jordan KMS Midwest RSM

Ecologix Immersed Flat Sheet MBR module

Production of Drinking and Service Water from Brackish and Sea Water

Fresh water production from municipal waste water with membrane technology and its application for agriculture in an arid area YOKOYAMA, Fumio *1,*2 A

Vibro a unique filtration device for micro- and ultrafiltration

DEVELOPMENT OF THE. Ken Mikkelson, Ph.D. Ed Lang Lloyd Johnson, P.E. Aqua Aerobic Systems, Inc.

Innovative Ultrafiltration (UF) Membrane for Produced Water Treatment

Design of a Laboratory Scale Test Facility for Cross Flow Micro- and Ultra- Filtration Membranes

PRESENTATION OUTLINE

Membrane Solutions for Landfill Leachate Treatment

PRO. Safe, clean drinking water on tap anywhere, anytime with UF-PRO Ultrafiltration Units...

Membrane BioReactor: Technology for Waste Water Reclamation

PERFORMANCE AND RESIDUAL MANAGEMENT ASSESSMENT OF 5 MGD MEMBRANE WATER PLANT. Presented by: Stephen P. Dorman, P.E.

THE CLEAR ADVANTAGE. INNOVATIVE FILTERS FOR process and potable water

Nanofiltration: New Developments Show Promise. Dr Graeme K Pearce, Membrane Consultancy Associates

Copper Removal from Cooling Tower Blowdowns

DOW TM Ultrafiltration

Hollow Fiber and Tubular UF Pilot Testing Procedures & Case Studies

Proven Solutions for the Most Challenging Wastewaters

Seawater desalination with Lewabrane LPT, 2016

Scientific & Technical Report

MEMCOR MEMBRANES FOR DRINKING WATER APPLICATIONS

HUBER Vacuum Rotation Membrane VRM Bioreactor

Project News. inge references. Issue 18 12/12/2017

Rotation Filtration. Dynamic Cross Flow Filtration

Key words: Integrated Membrane System, IMS, Seawater Reverse Osmosis, SWRO, SW30HRLE- 400, Ultrafiltration, UF, ZeeWeed 1000

Summary of Pilot Plant Results and Preliminary Recommendations

Aquaporin Inside Forward Osmosis Technology

Design Considerations for Small Drinking Water Membrane Systems

PRODUCTS & APPLICATIONS COURSE WATER TREATMENT PRESENTATION John Waema

Transcription:

AQUADYN Ultrafiltration Modules Smarter Solutions for Water Treatment

AQUADYN Hollow Fiber Modules AQUADYN modules are encased ultrafiltration hollow fiber membrane modules which effectively reduce micro-organisms and suspended solids from water. The AQUADYN series offers a comprehensive range of filtration modules for a wide spectrum of applications. At a choice of either modified Poly Acrylonitrile (PAN) or Poly Ethersulfone (PES) a huge selection of module sizes is available. These innovative membrane modules are developed by MANN+HUMMEL with vast R&D and business experience in filtration. The modules are manufactured under strict supervision and quality checks. Due to the optimized design efficient flow distribution, enhanced cleaning, minimal pressure drop and high packing density can be achieved. For applications requiring large capacities, extra large modules are available (10 x 60 ). Moreover, the AQUADYN UA (PAN) as well as the AQUADYN UE (PES) materials are superior in their hydrophilic property compared to most other polymeric materials. The enhanced hydrophilic property improves the wettability and reduces operating pressure. Additionally, it makes the membrane more resistant to fouling; resulting in less cleaning cycles and reduced chemical usage. The double asymmetric hollow fiber membranes offer another advantage over single asymmetric membranes. Bacteria, solids and turbidity can be rejected effectively due to a filtration layer inside and outside the hollow fiber. Therefore, problems such as pore clogging during backflush do not occur. ADVANTAGES» high flow rates (high hydrophilicity)» high and stable permeate performance» most reliable process (double asymmetric hollow fiber membranes)» effective retention of particles and bacteria» easy pre-treatment (100µm)» compact installation» high productivity» flexible flushing modes» low chemical demand

Module Specifications and Operating Data AQUADYN UA/UE Series Parameters UA420-BT 1) UA640 1) UA860 1) UA1060 1) UE1060 1) 2) Structure Hollow Fiber Hollow Fiber Hollow Fiber Hollow Fiber Hollow Fiber Membrane surface (m 2 ) 6 16 45 60 55 Poresize (µm) 0.025 0.025 0.025 0.025 0.025 Housing material Reinforced PP upvc Reinforced ABS and upvc upvc upvc Potting Epoxy Epoxy Epoxy Epoxy Epoxy Flow type Out / In Out / In Out / In Out / In Out / In Type of filtration Dead End Dead End Dead End Dead End Dead End Regeneration - Forward Flush, Forward Flush, Max Trans-Membrane- Pressure (bar) 3 1 1 1 1 ph range 2-10 2-10 2-10 2-10 2-12 Max Feed TSS (mg/l) 5 350 350 350 350 Note: (1) Only the information given in the data sheets of the single products is binding (2) NSF Approval Module Operating Process Product Water Feed water Suspended Solid Filtration Process Filtration process is an outside-in flow configuration where feed water is in contact with the exterior of the fibers and the filtrate (product water) is drawn from the inside of the hollow fibers (lumen). This configuration has the distinctive advantage of a larger membrane surface area which translates into higher flows. Air Bubble During the backflush process, air is injected into the module to loosen suspended solids on the fiber surface. This enables suspended solids in the module to be flushed out effectively and prevents solid build-up.

Flushing Modes for AQUADYN Ultrafiltration Modules Reject Reject Permeate Backflush Permeate Backflush Drain Feed Forward Flush Suspended Solid Air Bubble Feed Water Forward Flush Feed water flushes the exterior surface of the fiber and dilutes the retentate. Air scouring is incorporated along with this process to ensure the suspended solids are dislodged before backflushing. This reduces the use of permeate. Product Water Suspended Solid Backflush Either at pre-set intervals or when reaching a predetermined transmembrane pressure (TMP), the membrane module undergoes a backflush cleaning sequence where filtrate is used to backflush from the inside of the hollow fibers, hence dislodging the solids attached to the feed surface of the fiber.

AQUADYN Ultrafiltration Modules Decoding of the product code: U A 10 60 U E 10 60 Type Fiber Arrangement Membrane Material Ø Module [mm] Length Module [mm] UA420-BT U-Shape PAN 160 604 UA640 U-Shape PAN 168 1210 UA860 U-Shape PAN 216 1642 UA1060 U-Shape PAN 267 1737 UE1060 U-Shape PES 267 1737 Applications AQUADYN Modules efflluent treatment after biological wastewater plants pre-treatment to reverse osmosis (sea water and brackish water desalination) stormwater treatment surface water treatment borehole water treatment karst water filtration drinking water filtration Final sizing and selection has to be approved by an official MICRODYN-NADIR representative. Please contact phone + 49 611 962 6001 or www.microdyn-nadir.de 1 m 2 =^ 10.764 ft 2 1L =^ 0.26 us-gal. 1 =^ 2.54 cm

MICRODYN-NADIR GmbH Kasteler Straße 45 65203 Wiesbaden / Germany Phone: + 49 611 962 6001 info@microdyn-nadir.de MICRODYN-NADIR US, INC. 93 South La Patera Lane Goleta, CA 93117, USA Phone: + 1 919 341 5936 info@microdyn-nadir.com SEPARATION OUR PASSION For more than 50 years, MICRODYN-NADIR has developed innovative membranes and membrane modules for micro-, ultra- and nano-filtration as well as solutions to support our customers needs in operation, performance, efficient membrane processes and regulatory compliance. We will deliver products, information and services, which fully meet or exceed customer expectations. Our team focuses on continual improvement to achieve the highest possible level of customer satisfaction and to be recognized by our customers as the technology and quality leader. We are not satisfied until our products have been successfully integrated into your customers plants and processes. That is our passion. Our quality system is designed to support these goals. 00790581/03.2017 MICRODYN-NADIR (Xiamen) Co. Ltd No. 66 Jinting North Road Xinglin Xiamen, China 361022 Phone: + 86 592 677 5500 infochina@microdyn-nadir.cn MICRODYN-NADIR Singapore Pte. Ltd. 18 Tuas Avenue 8 639233 Singapore Phone: +65 6457 7533 info@microdyn-nadir.com Locations Sales Offices and Cooperations WE SUPPORT YOU WORLDWIDE!» Global availability» Intensive technical consulting» Ideal choice of membranes and modules» Support with engineering and plant design» Laboratory and pilot tests» After Sales Service WWW.MICRODYN-NADIR.COM 1