Microfil Filtration System

Similar documents
Microfil Filtration System

EZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration

EZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration

Built for Better Testing. EZ-Fit Filtration Units: Convenience without compromise. Data Sheet

MicroFunnel Filter Funnels

Swab and Samplers Test Kits Quality control as easy as 1, 2, 3

Heterotrophic Bacteria

Microbial Media and Culture Dishes

Streamline your microbial detection workflow with the Milliflex platform.

USEPA Membrane Filtration Method Method m-tec. Scope and Application: For potable water, nonpotable water, recreation water and wastewater.

Guideline Landscape. Quality Control

Swab and Samplers Test Kits Quality control as easy as 1, 2, 3

Membrane Solutions is manufacturer

Streamline your microbial detection workflow with the Milliflex platform.

2. 47 mm grid marked, white sterile 0.45 micron membranes (Millipore or equivalent) 4. Vacuum pump capable of inches of vacuum

At Your ServIce. Microbiology Services. The life science business of Merck operates as MilliporeSigma in the U.S. and Canada.

COLIFORM FILTERS. All filters listed on this page are white with black grids, 47 mm diameter, sterile.

EZ-Fluo System. For rapid detection of spoilage organisms in wine

PROFICIENCY TESTING PROGRAMS MICROBIOLOGY

Coliforms, Total and E. coli

Method 9.2 Drinking water and effluent: bacteria by the membrane filter method

Monitoring the quality of beverages, water and foods...

RiOs Essential 5, 8, 16, 24 Water Purification Systems

Your Goal is Zero Positives. So is Ours.

COMPARING THE ANTIMICROBIAL ACTIVITY OF THE SEMCO 3A TOTAL ENERGY WHEEL WITH OTHER SELECTED ANTIMICROBIAL SURFACE TREATMENTS RESEARCH FINDINGS

Microsart e.motion Filter Dispensers Make Membranes Move

Monitoring the quality of beverages, water and foods

1. Low profile units 2 Normal profile sterilisation filter units 3. Each pack includes 12 glass-fibre prefilters

Milliflex Rapid Microbiology Detection System

MICROBIOLOGICAL TOOLS FOR QUALITY ASSURANCE IN HATCHERY: Laboratory Methods

DAIRY WATERS. (Coliform Group and Escherichia coli) [E. coli verification required only on source water] IMS #24

Performance Evaluation and Cleanability Study using Pellicon 3 Cassettes with 30 kd Biomax and Ultracel Ultrafiltration Membranes

Lab Activity #14 - Bacteriological Examination Of Water and Milk (Adapted from Lab manual by Dr. Diehl)

Microbial Monitoring. Gusmer Enterprises April 2013

Microbiological Quality: Understanding Drinking Water Quality and Management

Air monitoring around the world.

IN THIS SECTION MICROBIOLOGY TESTING EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT. Bacterial Endotoxin (LAL) Testing

Principle of Lab. Safety

Finally, You Have a Choice! Online Ordering Available

Advantec MFS. Filtration Products

Milliflex Quantum Detection of microbial contaminants in water samples

STS Directory Accreditation number: STS 0268

Polysep II Filters. Superior filters provide multiple filtration stages in a single compact configuration for critical prefiltration applications

RiOs 3, 5, 8 Water Purification Systems

ANALYTICAL PROCEDURE. Bacteria: Hydrogen Sulfide Producing

RiOs 3, 5, 8 Water Purification Systems

Public Health Microbiology Lab. Cork Integrated Service Area(ISA), HSE South

Biocontamination control in pharmaceutical production

Originally released 12/2017 with proposed compliance date extension and equivalent methods Updated 07/2018 to include FDA updates to equivalent

Make the invisible visible HY-LiTE Plus.

Monitoring the quality of drinking water

BIO & PHARMA ANALYTICAL TECHNIQUES

Plastic Storage Bottles Product Selection Guide

mdi Filters for Pharmaceutical and Biological

Hamilton PRP Polymeric Columns

Advanced. Anoxomat System. For the cultivation of anaerobic, microaerophilic, and capnophilic bacteria

Merck Millipore BioMonitoring

Validation Guide for and

rios Water Purification system The standard for laboratory-grade water

Biocidal Surface Test - Clinell Wipes ~ Project Report Prepared for GAMA Healthcare Ltd ~ Huddersfield Microbiology Services Oct 06

Thermo Scientific Heracell VIOS 160i CO 2. Incubator with Cell Locker System. Protected chambers for your most sensitive cells

Thermo Scientific Heracell VIOS 160i CO 2. Incubator with Cell Locker System. Protected chambers for your most sensitive cells

Synchronised solutions for cell culture

TITLE : : SABS/TC 147/SC

Milli-Q Reference Water Purification System. The reference for ultrapure water systems

Milligard Filters. Superior filters for critical prefiltration applications. Benefits. Data Sheet. Data Sheet

Public Health Microbiology Lab. Cork Integrated Service Area(ISA), HSE South

Environment Agency. Methods for the Examination of Waters and Associated Materials

Test Method of Specified Requirements of Antibacterial Textiles for Medical Use FTTS-FA-002

RapidChek SELECT Salmonella Test Kit

Monitoring the quality of drinking water

Supor PES Membrane Disc Filters

LAB. Interpretation Guide. Lactic Acid Bacteria Count Plate

Microbiological tests not just for safe drinking water. PRACTICE REPORT MICROBIOLOGY Author: Dr. Elmar Grabert, HACH LANGE GmbH, Germany

TECHNICAL NOTENo. 6 DECEMBER Authors: - Olivier MOLINIER - Mylène MARECHAL

á62ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: TESTS FOR SPECIFIED MICROORGANISMS

Standard Operating Procedure for the Sampling and Analysis of Total Suspended Solids in Great Lakes Waters

ISO INTERNATIONAL STANDARD. Water quality Detection of Salmonella spp. Qualité de l'eau Recherche de Salmonella spp. First edition

Just Prove it. Spectroquant Prove

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS

Microbiological Methods

Milli-Q Reference Water Purification System. The reference for ultrapure water systems

FLUID CLEANLINESS OIL FILTRATION

Microbiology sheet (6)

Milli-Q Reference Water Purification System

TRYPTIC SOY AGAR (TSA) WITH LECITHIN AND TWEEN 80

RiOs-DI Water Purification Systems

COMPARATIVE STUDY ON THE MICROBIOLOGICAL QUALITY OF WATER COOLER DISPENSERS AND TAP WATER

3 8 COLIFORM BACTERIA AS INDICATOR ORGANISMS Laboratory tests for disease-producing bacteria, viruses, and protozoa are difficult to perform

How to perform a Gram Stain. Jasleen Singh

Millistak+ Pod carbon depth filter media system

New and Amended Methods

BacTrac 4300 Microbiological Multi Monitoring System. Fast Automated Documented

Tests to Support Sterility Claim. Imtiaz Ahmed

Standing Committee of Analysts

Rapid Microbiological Methods: Why and what!

INTERNATIONAL STANDARD

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised November 2015

THE COLISCAN MEMBRANE FILTER METHOD of Micrology Laboratories LLC for ESCHERICHIA COLI AND TOTAL COLIFORMS

PROJECT TITLE (DNR PROJECT #226): Evaluation of Quantitative Real-Time PCR (qpcr) for the Measurement of E.coli in Well Water Samples

Transcription:

Data Sheet Microfil Filtration System An easy to use, fast and accurate system for the routine microbiological analysis of your beverages and drinking water The Microfil filtration system is a simple and reliable solution for routine testing of raw materials, beverages and water for microbiological contamination. These tests are an important part of your quality assurance program. The standard testing method used in laboratories around the world for microbial analysis of fluids is membrane filtration. However, this method is technically demanding and requires time-consuming preparation, assembly and sterilization of the test apparatus. With MilliporeSigma's Microfil filtration system, you will eliminate time-consuming steps, equipment setup, waste, and autoclaving while improving the productivity of your lab. This cost-effective system uses presterilized, ready-to-use funnels and membranes on a filtration support. Benefits No Preparation No Washing No Autoclaving No Clamps No Breakage No Filter Wrinkling No By-pass The life science business of Merck KGaA, Darmstadt, Germany operates as MilliporeSigma in the U.S. and Canada.

Minimize Clean-Up, Assembly and Autoclaving Ready-to-use, ultra-thin 100 or 250 ml Microfil funnels eliminate the need for washing and sterilizing after each test and make equipment handling easy. Packaged in convenient stacks of 25 or 30, the funnels are removed as needed from the custom designed funnel dispenser. Such vertical stacking of the funnels also optimizes lab space. A range of pre-sterilized 47 mm diameter gridded membranes are available with the Microfil funnels. Each membrane is individually sealed in pleated band (EZ-Pak membranes) or in peel back envelopes (S-Pak membranes). Polycarbonate membranes are also available. Easy-to-Use with No Clamps and No O-Rings The push-fit design of the Microfil funnels seals tightly to manifold supports without the need for clamps or O-rings. This ensures leak-free operation and uniform microorganism recoveries. Membrane Lifting Device The membrane lifting device automatically breaks residual vacuum and lifts the membrane for easy removal with forceps. This aids in removing the membrane from the support after filtration, also reducing user-related contamination during the membrane transfer process. Consistent Recoveries Unlike with conventional filter holders, incomplete sealing at the membrane/funnel interface is eliminated resulting in uniform recovery of organisms. The smooth hydrophobic funnel surface repels sample residues and microorganisms to ensure that any microorganisms in your sample are collected on the membrane and not lost on the funnels walls. Pleating and distortion of the wet membrane due to expansion is avoided by the design of the support. As a result, uniform contact between the membrane and the medium is achieved. Faster Filtration Rates Due to the membrane support, filtration rates with the Microfil filtration system are faster when compared to traditional filtration equipment. Culture Media You will find the full range of MilliporeSigma culture media (including broth and dehydrated media) on our website at EMDMillipore.com. 2

Regulatory Requirements The Microfil filtration system method has been established with reference to International Standards allowing biological analysis to be conducted under optimum conditions and conforms to International Standards for drinking water and mineral water. United States Standard Methods for the Examination of Water and Wastewater 22 edition, 2012 Europe EEC Directive 2009/54/EC of the European Parliament and of the council of 18th June 2009 EEC Directive 98/83/EC, 3 November, 1998, relating to the quality of water intended for human consumption Worldwide WHO Guidelines for Drinking Water Quality, 1993 ISO Regulations ISO 11731-2:2004: Water Quality Detection and enumeration of Legionella Part 2: Direct membrane filtration method for waters with low bacterial counts ISO 8199:2005: Water Quality Water quality General guidance on the enumeration of microorganisms by culture ISO 7899-2:2000: Water Quality Detection and enumeration of intestinal enterococci Part 2: Membrane filtration method ISO 9308-1:2014: Water Quality Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora ISO 19250:2010: Water Quality Detection of Salmonella spp. ISO 6461-2:1986: Water Quality Detection and enumeration of the spores of sulfite-reducing anaerobes (clostridia); Part 2: Method by membrane filtration ISO 7704:1985: Water Quality Evolution of membrane filters used for microbiological analyses ISO 16266:2006: Water Quality Detection and enumeration of Pseudomonas aeruginosa by membrane filtration ISO 14189:2013: Water Quality Enumeration of Clostridium Perfringens Method using membrane filtration ISO 17995:2005: Water Quality Detection and enumeration of thermotolerant Campylobacter species Microfil Filtration System Method Advantages Use of 47 mm gridded presterilized membranes 100 ml and 250 ml funnels for drinking water and mineral water analysis Hydrophobic funnel surfaces for improved recovery Smooth interior funnel surfaces with no scratches Lip seal to prevent membrane by-pass Food-contact-polymer funnels, free from agents that may inhibit bacterial growth Disposable funnels eliminate decontamination by flaming or use of alcohol Recyclable plastic funnel material that allows for greater environmental protection 0.45 μm membranes are certified in accordance with Standard Methods for coliform analysis 3

Processing an aqueous sample using the Microfil filtration system can be done in 7 simple steps: Step 1 Sanitize the Microfil filtration system support prior to processing each sample. Recommended methods include the use of alcohol or a quick flaming of the Microfil filtration system support steel surface. Step 2 Place either an EZ-Pak, S-Pak or a polycarbonate membrane filter on the Microfil filtration system support. Step 3 Dispense a Microfil funnel using the specially designed dispenser. Step 4 Place the Microfil funnel on the support and push down to fix it firmly in place. 4

Step 5 Pour the sample into the funnel and filter by applying vacuum. Step 6 Remove the funnel. Simply press the lever to lift the membrane off the support for easy removal with forceps. Residual vacuum is broken at the same time. Step 7 Place the membrane filter into a Petri dish containing solid or liquid medium and incubate. Step 8 Filter support can easly be removed for decontamination. 5

Ordering Information 150 Funnels and 150 S-Pak Membranes Each box contains 6 x 25 (100 ml) or 5 x 30 (250 ml) sterilized Microfil funnels and 150 individually packed, sterilized 47 mm diameter gridded S-Pak membranes, available with the following pore sizes and colors: Membrane Description 100 ml Funnels 250 ml Funnels 0.2 µm white, gridded MIGSWG100 MIGSWG250 0.45 µm white, gridded MIHAWG100 MIHAWG250 0.45 µm white, plain MIHVWP100 N/A 0.45 µm black, gridded MIHABG100 MIHABG250 0.7 µm white, gridded MIHCWG100 MIHCWG250 0.8 µm white, gridded MIAAWG100 MIAAWG250 1.2 µm white, gridded MIRAWG100 MIRAWG250 150 Funnels and 150 Isopore Polycarbonate Membranes Membrane Description 100 ml Funnels 250 ml Funnels 0.4 μm; colorless, plain N/A MIHTTP250 Additional membranes are available - 0.4 μm; colorless, plain - 150 units - item MIHTTPMNE 150 Funnels and 150 EZ-Pak Membranes Each box contains 6 x 25 (100 ml) or 5 x 30 (250 ml) sterilized Microfil funnels and a band of 150 individually packed, sterilized 47 mm diameter gridded EZ-Pak membranes, available with the following pore sizes and colors: Membrane Description 100 ml Funnels 250 ml Funnels 0.2 µm white gridded MZGSWG101 N/A 0.45 µm white, gridded MZHAWG101 MZHAWG251 0.45 µm black, gridded MZHABG101 MZHABG251 0.8 µm white, gridded MZAAWG101 MZAAWG251 0.8 µm black, gridded MZAABG101 N/A 6

Equipment Description (1/Pk) 3-Position Vacuum Manifold, complete with Microfil filtration system supports 1-Position Vacuum Manifold, complete with Microfil filtration system supports Microfil Support with integrated valve 11/4 Microfil Funnel Dispenser, for use with 100 ml funnels Microfil Funnel Dispenser, for use with 250 ml funnels EZ-Pak Dispenser Curve EZ-Stream Vacuum Pump for Liquid Transfer Milliflex plus vacuum pump base Microfil filtration system pump head for MilliporeSigma vacuum pump Cat. No. MIAC03P01 MIAC01P01 MIAC01401 MIACFD101 MIACFD201 EZCURVE01 EZSTREAM1 MXPPUMP01 MCLHEAD01 Petri Dishes 47 mm Petri Dishes, packed in sleeves of 25 dishes. Available with or without cellulose pad. Description (1/Pk) Qty/Pk 100 ml Funnels Cat. No. Petri Dish without pad 150 PD2004700 Petri Dish without pad 600 PD2004705 Petri Dish with pad 150 PD20047S0 Petri Dish with pad 600 PD20047S5 10 canisters of 100 absorbent pads 1000 AP10045S0 1 pad dispenser and 2 pad canisters 200 pads & 1 dispenser AP10045S1 0.45 μm with MCE membrane absorbent pads in canister 600 HAWG674SP HAWG674SP We provide information and advice to our customers on application technologies and regulatory matters to the best of our knowledge and ability, but without obligation or liability. Existing laws and regulations are to be observed in all cases by our customers. This also applies in respect to any rights of third parties. Our information and advice do not relieve our customers of their own responsibility for checking the suitability of our products for the envisaged purpose. For more information, please visit EMDMillipore.com/EZ 7

To Place an Order or Receive Technical Assistance In the U.S. and Canada, call toll-free 1(800)-645-5476 For other countries across Europe, call +44 (0) 115 943 0840 For other countries across Europe and the world, please visit EMDMillipore.com/offices For Technical Service, please visit EMDMillipore.com/techservice MilliporeSigma 290 Concord Road Billerica, MA 01821 Copyright 2017 EMD Millipore Corporation. All Rights Reserved. MilliporeSigma, Milli-Q, Millipore and the Vibrant M are trademarks of Merck KGaA, Darmstadt, Germany. Sigma-Aldrich, Supelco, SAFC and Bioreliance are trademarks of Sigma-Aldrich Co. LLC. or its affiliates. EZ-Pak, EZ-Stream, Isopore, Microfil, Milliflex and S-Pak are trademarks of Merck KGaA, Darmstadt, Germany. All other trademarksare the property of their respective owners. milliporesigma.com DS1047ENUS Ver. 3.0 2017-05241 06/2017