Specifications. Materials and Fabrication. Physical Properties. Environmental Impact. Sizes. Installation - General Requirements.

Similar documents
LP OSB Sheathing & Structural 1 Sheathing

Eclipse OSB Radiant Barrier OSB Structural Panels from RoyOMartin

RoyOMartin TuffStrand and Windbrace 7/16 Performance Category OSB PR-N129 Martco, L.L.C. Revised November 6, 2017

City of Long Beach Department of Development Services Building and Safety Bureau. Design Limitation for Wood Shear Walls

MEETING FIRE CODE WITH ORIENTED STRAND BOARD

Warmboard-S Radiant-Floor Heating Panels PR-V180 Warmboard, Inc. Revised February 19, 2018

LP SmartSide Strand Substrate Treated-Engineered-Wood Lap & Panel Siding Louisiana-Pacific Corporation Revised December 2, 2016

TECH BULLETIN. SIP No. Subject: Engineered Wood Lap Siding from Louisiana-Pacific. Date: August 2010 (Revised January 2015)

Joint Evaluation Report ICC-ES (800) (562)

The LP Family of Sub-Flooring

PR-L274 Nordic Structures Revised April 16, 2017

PRP-108 Performance Standards and Policies for Structural-Use Panels

CODE COMPLIANCE, STRENGTH AND SAVINGS IN ONE PANEL

Strong-Drive SDWS TIMBER Screw

Image courtesy of KTGY, Inc. ENGINEERED FOR FIRE CODE COMPLIANCE AND DESIGN FLEXIBILITY

Image courtesy of KTGY, Inc. ENGINEERED FOR FIRE CODE COMPLIANCE AND DESIGN FLEXIBILITY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: LOUISIANA PACIFIC CORPORATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

Featuring Selection and Installation Information for Lateral Wind Loads

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

Multi-Institutional Academic Health Science & Research Center Evansville, IN

AdvanTech Sheathing and Subfloor Panels

HIGH PERFORMANCE FIRE RETARDANT TREATED WOOD PRODUCTS

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

International Beams Revised June 15, 2018

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

Trusted ICC ES APA TH STREET. Conformity! subject of the

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels ( )

LPI 56 Technical Guide

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Design Guide Revised 11/17/2016

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

LP SmartSide Perfection Shingle

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

KERTO HEADER INSULATED LVL HEADER 31/2", 51/2" 3 1/2" AND 5 1/2" THICKNESSES DESIGN VALUES USA

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

ZIP System Sheathing Load-Span Tables

SECTION Fiber Reinforced Stucco 1

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Overview Revised 11/17/2016

ESR-2961 Reissued September 1, 2011 This report is subject to renewal in two years.

Joint Evaluation Report

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

Originally Issued: 11/04/2016 Revised: 11/28/2017 Valid Through: 11/30/2018

THE ENGINEERED WOOD ASSOCIATION

Joint Evaluation Report

Joint Evaluation Report

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

Ready-to-Frame Solutions for the Fire Protection of Floors. LP SolidStart LSL and LP FlameBlock I-Joists. U.S. Technical Guide U.S.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION

Joint Evaluation Report ICC-ES (800) (562)

STRUCTURAL CALCULATIONS EXTERIOR SIDING CLADDING SYSTEM FLUSH PANEL SIDING SYSTEM AND LAPPED PANEL SIDING SYSTEM

Table R (1) Allowable Spans and Loads for Wood Structural Panels for Roof and Subfloor. Sheathing and Combination Subfloor Underlayment

2008 Special Design Provisions for Wind and Seismic

ESR-1882 Reissued February 1, 2013 This report is subject to renewal February 1, 2014.

Contents. ZIP System R-Sheathing

SDPWS. Special Design Provisions for Wind & Seismic 2015 EDITION

Gold Bond BRAND Gypsum Sheathing

EDGE AND EDGE GOLD FLOOR PANELS

Diaphragms 2. Design Process. Design Process. Diaphragms are the roofs and floors of the upper stories

SECTION COLD-FORMED METAL TRUSSES

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

PFC-5804* Reissued February 1, Filing Category: DESIGN Wood

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

CH. 9 WOOD CONSTRUCTION

Build A Better Floor, Every Step Of The Way. LPCorp.com

The Engineered Wood Association DESIGN/CONSTRUCTION GUIDE NONRESIDENTIAL ROOF SYSTEMS

Installation of Stucco Exterior Finish Over Wood Structural Panel Wall Sheathing

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

CHAPTER 5 FLOORS SECTION R501

Listing Report: MUR Reissue Date: 12/07/17 This report is subject to annual review

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

A. Meet at Project site <insert number> days before starting installation.

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

DECK PERMIT APPLICATION

Mid-Rise Engineering Considerations for Engineered Wood Products

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

FIGURE R502.2 FLOOR CONSTRUCTION

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: AFM CORPORATION

C. Delegated-Design Submittal: For metal-plate-connected wood trusses indicated to comply with

WALL CONSTRUCTION CHAPTER 6

Copyright Materials. Fire-Rated Cementitious Coated OSB in Wall and Roof Sheathing Applications

LVL Product Guide 2.0E LVL 1.5E LVL

Transcription:

Specifications Materials and Fabrication Physical Properties LP FlameBlock Fire-Rated OSB Sheathing panels are made of oriented strand board (OSB) with a fire-resistant, cementitious coating (Pyrotite TM ) bonded to one or both sides. The coating consists of a highly hydrated, magnesium oxychloride cement reinforced with fiberglass. The LP OSB substrate is manufactured to be consistent and free of knots, grain defects, core voids, splits and other irregularities. The wood strands are mixed with resins, arranged in layers for strength and stability and bonded under heat and pressure. The panels are sealed on all four edges for added moisture resistance and dimensional stability. LP FlameBlock Fire-Rated OSB Sheathing roof panels have a coarse-textured top surface that helps provide safe footing on pitched roofs. The panels should be fastened with conventional nailing techniques. Consult your local building authorities regarding acceptability of fastenings techniques. The panels may be sawn cleanly, and may be routed or drilled with standard woodworking tools. Sizes LP FlameBlock Fire-Rated OSB Sheathing panels are fabricated in standard ft. 11-7/8 in. x 7 ft. 11-7/8 in. size (products are undersized 1/8 in. to allow for proper spacing during installation). Extended length panels are available. Limitations LP FLAMEBLOCK FIRE-RATED OSB SHEATHING PANELS ARE NOT FOR UNPROTECTED EXTERIOR USE. They must be covered with siding panels or other types of exterior wall cladding or roofing material. Normal exposure to weather during ordinary construction delays will not damage the panels. ADDITIONAL PROTECTIVE MEASURES ARE RECOMMENDED FOR EXTENDED ADVERSE WEATHER CONDITIONS. EXCEPTION: Panels identified as Exposure 1 may be used for roof sheathing where exposed on the underside, such as on eaves. When used in this application, the underside and any exposed edges of panels must be coated with exterior-grade paint. Slight surface flaking or thickness swell caused by moisture exposure will not affect structural performance. Fire Performance meet the requirements of a Class A Flame Spread Rated material as defined in ASTM E-84 (Intertek Listing 15-4), as well as Class A and Class C roof deck as defined in ASTM E-108 (verified by Underwriters Laboratories). LP FlameBlock Fire-Rated OSB Sheathing is an approved component in fire-rated wall assemblies. Find more information at www.lpcorp.com/flameblock and in our ICC Evaluation Report, ESR-165. LP FlameBlock Fire-Rated OSB Sheathing wall panels provide sufficient racking strength to meet corner bracing requirements. Panels are stiff and strong and have a low coefficient of lineal expansion. For additional technical and engineering information and Material Safety Data Sheets, contact your LP sales representative or visit www.lpcorp.com/flameblock. Environmental Impact LP products are manufactured in accordance with the company s policy on protection of the environment which includes: Use of environmental control technology and energy efficient equipment to conserve resources. Use of wood by-products to produce energy, thereby conserving nonrenewable resources. Use of SFI -certified forest management and procurement systems, which help ensure that wood comes from well-managed forests. Efficient use of raw material to produce engineered wood products that offer more consistent performance and strength than non-strand-based products. For more information, see our LP FlameBlock Fire-Rated OSB Sheathing Green Brief. Installation - General Requirements Comply with local safety regulations when installing roof, wall, or subfloor sheathing. Comply with the following manufacturer s instructions and with APA s Engineered Wood Construction Guide Form E0U (September 007) or the current equivalent. Storage and Handling Store panels in clean, dry areas off the ground. If possible, store indoors. If stored outside, cover with plastic sheets, tarps or the LP FlameBlock Fire-Rated OSB Sheathing unit cover. Keep cover open and away from the sides and bottom of panels to allow for air circulation. Additional protective measures may be necessary during extended adverse weather conditions. Roof Installation Place the skid-resistant side up with the white fire-resistant surface facing down and wear skid-resistant shoes when installing LP FlameBlock Fire-Rated OSB Sheathing as roof sheathing on either side of a partition wall in multi-family residential buildings, or in any application where reducing the spread rate of an interior fire is the intent of the code requirement. Install LP FlameBlock Fire-Rated OSB Sheathing with the white Pyrotite TM side facing upwards when used under EPDM roof membranes and in other applications where reducing the spread rate of fire from an exterior source is the intent.

Install with the long dimension or strength axis of the panel across supports and with the panel continuous over two or more spans. Provide 1/8 in. space at panel ends and edges. Use a spacer tool (i.e. 10d box nail) to ensure accurate and consistent spacing. Panel end joints shall occur over framing. Stagger end joints in each succeeding row. For panels in the and 15/ category, provide additional panel stiffness by installing panel edge clips mid-span on all un-supported edges. Nail 6 in. o.c. along supported panel ends and edges and 1 in. o.c. at intermediate supports. Fasten panels /8 in. from panel edges. Use 8d common nails for panels up to 1 in. thickness. For panels over 1 in. use 8d ring-shank or 10d common nails. Other code-approved fasteners may be used. Cover roof sheathing as soon as possible with roofing felt or shingle underlayment for protection against excessive moisture prior to roofing. If any edge swelling occurs prior to roof underlayment installation, the exposed wood substrate side of panels with raised joints should be sanded flat. Wall Installation LP FlameBlock Fire-Rated OSB Sheathing panels should be installed as specified in the relevant fire-rated assembly. In the absence of a listed fire-rated assembly, panels should be installed vertically, with the horizontal joints blocked. When installing LP FlameBlock Fire-Rated OSB Sheathing in walls, consult approved construction plans to determine the proper orientation of the white, fire-resistant panel surface. Provide 1/8 in. space between panel ends and edges. Use a spacer tool (i.e. 10d box nail) to ensure accurate and consistent spacing. At minimum, nail 6 in. o.c. along supported panel ends and edges and 1 in. o.c. at intermediate supports. Fasten panels /8 in. from panel edges. Use 6d common nails for panels up to 1 in. thickness. For panels over 1 in. use 8d ring-shank or 8d common nails. Other code-approved fasteners may be used. For additional fastening requirements, refer to Figure. NOTE: For shear walls, use the fastener type and spacing specified in approved construction documents. Remove wrinkles and flatten surface of shingle underlayment before installing shingles. High performance shingle underlayment is recommended for better results. Heavier weight and/or textured shingles are recommended to better mask imperfections in roofing assembly. When installed as roof deck in open eaves, the exposed underside of panels, as well as any exposed edges, must be coated with exterior-grade paint. NOTE: Check with your local building department before deciding on an installation method. LP FlameBlock Fire-Rated Sheathing Product Description LP FlameBlock Fire-Rated OSB Sheathing panels are designed for use in roof, wall and subfloor systems in commercial and residential projects, maintenance, remodeling or new construction. Structural performance is verified by Progressive Engineering, Inc. (Report, PER-0601), www.p-e-i.com. Fire performance is verified by Omega Point/Intertek (listing 15-4). Directory can be referenced at www.opl.com. Standards & Certifications LP FlameBlock Fire-Rated OSB Sheathing panels comply with the following industry standards and certifications: comply with U.S. Voluntary Product Standard PS, which is recognized in the Uniform Building Code, the International-Building Code and the International Residential Code, and by International Code Council Evaluation service (ICC-ES) Evaluation Report ESR-165.

FIGURE 1. RECOMMENDED UNIFORM ROOF LIVE LOADS FOR LP FLAMEBLOCK FIRE-RATED SHEATHING (c) AND RATED SUBFLOOR WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS (c) Panel Span Performance Maximum Span (in.) Allowable Live Loads (psf) (b) Rating Category** With Edge Support (a) Without Edge Support Spacing of Supports Center-to-Center (in.) Rated Sheathing (c) 1 16 0 4 40 48 60 4/16 4 4 190 100 65 40 /16 15/, 1/ 8 5 180 10 94 0 40/0 19/, 5/8 40-05 05 151 60 0 48/4 /, /4 48 6 - - 80 175 95 45 5 60/ 7/8 60 40 - - - 05 165 100 70 5 60/48 1-1/8 60 48 - - - 05 165 100 70 5 Rated Subfloor (c) 1 16 0 4 40 48 60 16 oc 19/, 5/8 4 4 185 100 65 40 0 oc 19/, 5/8 70 150 100 60 0 4 oc /, /4 48 6-40 160 100 50 0 5 oc 7/8 48 40 - - 95 185 100 60 40 48 oc 1-/, 1-1/8 60 48 - - - 90 160 100 65 40 (a) Tongue and groove edges, panel edge clips (one midway* between each support, except two equally spaced between supports 48 in. on center or greater), lumber blocking, or other. (b) 10 psf dead load assumed (c) Applies to panels 4 in. or wider applied over two or more spans. * No established tolerance. **Performance Category replaces the fractional nominal thickness used in PS and is consistent with the panel thickness used in the U.S. model building codes. LP FlameBlock Fire-Rated Structural 1 Sheathing Product Description LP FlameBlock Fire-Rated Structural 1 Sheathing panels are designed to perform as roof, sidewall and floor systems, where high wind or earthquake conditions may occur. LP FlameBlock Fire-Rated Structural 1 Sheathing panels are equally suited for pitched or flat roof applications. LP FlameBlock Fire-Rated Structural 1 Sheathing panels can be used in commercial and residential projects, such as industrial buildings, mobile and modular home construction or in any application requiring high strength, superior shear values, and fire resistance. Standards & Certifications LP FlameBlock Fire-Rated OSB Sheathing panels comply with the following industry standards and certifications: comply with U.S. Voluntary Product Standard PS, which is recognized in the Uniform Building Code, the International-Building Code and the International Residential Code, and by International Code Council Evaluation Service (ICC-ES) Evaluation Report/ESR-165. Structural performance is verified by Progressive Engineering, Inc. (Report, PER-0601), www.p-e-i.com. LP FlameBlock Fire-Rated Structural 1 Sheathing panels have superior maximum live load over standard OSB when installed with the long axis parallel to the structural supports. Figure. LP FlameBlock Structural 1 Rated Sheathing Roof Panels Parallel to Supports Performance Category Span Rating Max. Live Load for Roofs (lbs)** 4/16 40 15/ /16 70 1/ /16 70 ** Live load for 4 in. o.c. span conditions. 10 psf dead load assumed. Availability LP FlameBlock Fire-Rated OSB Sheathing panels are available directly from LP by railcar, as well as piggyback and truckload shipment. Call LP customer service or visit our web site for more information on OSB structural panels and other LP products. Customer Service: 888.80.05 www.lpcorp.com Sales Office: Nashville, TN 800.964.610 Fire performance is verified by Omega Point/Intertek (listing 15-4). Directory can be referenced at www.opl.com.

FIGURE. ALLOWABLE SHEAR (POUNDS PER FOOT) FOR PANEL SHEAR WALLS WITH FRAMING OF DOUGLAS-FIR, LARCH, OR SOUTHERN PINE (a) OR WIND OR SEISMIC LOADING (b,f, g, h, i) (See also 006 IBC Table 06.4.1) Panels Applied Over Panels Applied Direct to Framing 1/ or 5/8 Gypsum Sheathing Panel Performance Minimum Grade Category** Nail Nail Size Nail Spacing Nail Size Nail Spacing Penetration (Common or at Panel Edge (in.) (common or at Panel Edges (in.) in Framing Galvanized Box) Galvanized (in.) 6 4 (e) Box) 6 4 (e)(d) Structural 1 Grades Rated Sheathing 1-/8 8d 55 95 505 670 (c) 15/ 80 40 550 70 10d 80 40 550(e) 70 15/ 1-1/ 10d 40 510 665 (e) 870 1-/8 8d 40 50 450 585 (c) 10d 60 80 490 (e) 640 15/ 60 80 490 640 15/ 10 460 600 (e) 770 1-1/ 10d 5/8 40 510 665 (e) 870 (a) For framing of other species: (1) Find specific gravity for species of lumber in the AF&PA National Design Specification. () For common or galvanized box nails, find shear value from table above for nail size for actual grade. () Multiply value by the following adjustment factor: Specific Gravity Adjustment Factor = [1-(0.5 - SG)], where SG = specific gravity of the framing. This adjustment shall not be greater than 1.*** (b) All panel edges backed with -in. nominal or wider framing. Install panels either horizontally or vertically. Space nails maximum 6 in. o.c. along intermediate framing members for /8 Category and Category panels installed on studs spaced 4 in. o.c. For other conditions and panel thicknesses, space nails maximum 1 in. o.c. on intermediate supports. Fasteners shall be located /8 in. from panel edges.*** (c) Allowable shear values are permitted to be increased to values shown for 15/ category sheathing with same nailing provided (1) studs are spaced a maximum of 16 in. o.c., or () panels are applied with long dimension across studs.*** (d) Framing at adjoining panel edges shall be -in. nominal or wider, and nails shall be staggered where nails are spaced in. o.c. Check local code for variations of these requirements.*** (e) Framing at adjoining panel edges shall be -in. nominal or wider, and nails shall be staggered where 10d nails ( in. x 0.148 in.) having penetration into framing of more than 1-1/ in. are spaced inches o.c. Check local code for variations of these requirements.*** (f) Where panels are applied on both faces of a wall and nail spacing is less than 6 in. o.c. on either side, panel joints should be offset to fall on different framing members. Or framing shall be in. nominal or thicker and nails on each side should be staggered.*** (g) In Seismic Design Category D, E, or F, where shear design values exceed 50 pounds per lineal foot, all framing members receiving edge nailing from abutting panel edges shall not be less than a single -in. nominal member, or two -in. nominal members fastened together in accordance with 006 IBC Section 06.1 to transfer the design shear value between framing members. Wood structural panel joint and sill plate nailing shall be staggered in all cases. See 006 IBC Section 05.11 for sill plate size and anchorage requirements.*** (h) Galvanized nails should be hot dipped or tumbled.*** (i) For shear loads of normal or permanent load duration as defined by the AF&PA NDS, the values in the table above should be multiplied by 0.6 or 0.56 respectively.*** **Performance Category replaces the fractional nominal thickness used in PS. ***Typical Layout for Shear Walls table

FIGURE 4. ALLOWABLE SHEAR (POUNDS PER FOOT) FOR HORIZONTAL LP PANEL DIAPHRAGMS WITH FRAMING OF DOUGLAS-FIR, LARCH OR SOUTHERN PINE (a) FOR WIND OR SEISMIC LOADING (b) (See also IBC Table 06.1) Blocked Diaphragms Unblocked Diaphragms Panel Grade Common Nail Size Minimum Nail Penetration in Framing (in.) Performance Category** Minimum Nominal Width of Framing Members at Adjoining Panel Edges and Boundaries (e) (in.) Nail Spacing (in.) at diaphragm boundaries (all cases), at continuous Panel edges parallel To load (Cases & 4), And at all panel Edges (Cases 5 & 6) (c) 6 4-1/ (d) (d) Nail Spacing (in.) at Other Panel Edges (Cases 1,, & 4) (c) Nails Spaced 6 max at Supported Edges (c) Case 1 (No unblocked edges or continuous joints parallel to load) All other Configurations (Case,, 4, 5 & 6) LP Structural 1 Grades 10d (g 1-1/ 15/ 0 60 45 480 640 70 70 80 85 0 15 40 LP Rated Sheathing 8d (f) 10d (g) 1-/8 1-1/ 15/ 15/ 5/8 55 85 70 00 90 5 0 60 40 80 60 400 85 40 45 480 505 570 50 600 575 650 640 70 575 645 600 675 655 75 70 80 0 55 40 65 55 90 85 0 170 190 180 00 190 15 15 40 (a) For framing of other species: (1) Find specific gravity for species of lumber in the AFPA National Design Specification () Find shear value from table above for nail size for actual grade () Multiply value by the following adjustment factor: Specific Gravity Adjustment Factor = [1-(0.5 SG)], where SG = specific gravity of the framing. This adjustment shall not be greater than 1. (b) For shear loads of normal or permanent load duration as defined by the AF&PA NDS, the values in the table above should be multiplied by 0.6 or 0.56, respectively. (c) Space nails maximum 1 in. o.c. along intermediate framing members (6 in. o.c. when supports are spaced 48 in. o.c. or greater). Fasteners shall be located /8 in. from panel edges. (d) Framing at adjoining panel edges shall be in. nominal or wider, and nails should be staggered where nails are spaced in. o.c. or -1/ in. o.c. (e) The minimum normal width of framing members not located at boundaries or adjoining panel edges should be in. (f) 8d is recommended minimum for roofs due to negative pressures of high winds. (g) Framing at adjoining panel edges should be in. nominal or wider, and nails should be staggered where 10d nails having penetration into framing of more than 1-1/ in. are spaced inches o.c. Note: Design for diaphragm stresses depends on direction of continuous panel joints with reference to load, not on direction of long dimension or strength axis of sheet. Continuous framing may be in either direction for blocked diaphragms. **Performance Category replaces the fractional nominal thickness used in PS. Cal. Prop 65 Warning: Use of this product may result in exposure to wood dust, known to the State of California to cause cancer. 011 Louisiana-Pacific Corporation. LP is a registered trademark of Louisiana-Pacific Corporation. APA and Struc 1 are registered trademarks of APA The Engineered Wood Association. Pyrotite is a registered trademark of Barrier Technology Corporation. All rights reserved. Printed in USA. Specifications subject to change without notice. LPFB0017