Moisture Meter Instruction Manual. Wagner Model BI 2200

Similar documents
Concrete Moisture Meter

Moisture Meter Instruction Manual

Moisture Meter Instruction Manual. for Wagner Meters Models: MMC 205 MMC 210 MMC 220

RAPiD Safe Setup and Operation

MODEL MT-215 TTL SINGLE OR DUAL HEAD INSERTION READER TECHNICAL REFERENCE MANUAL

Operating Instructions

EP100 EMERGENCY POWER BANK

itemp Anywhere Wireless Sensors and Cellular Gateway User s Guide

RAPiD VEHICLE SAFE. Owner s Manual. Instructional videos for Hornady Security products are available at hornady.com. With patented RFID technology.

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

Age User s Guide. Dominator Drone

AVerMedia AVerDVR POS Capture Box Quick Guide

Model 292A. Surface Resistance Test Kit. Instruction Manual

Owner s Manual & Safety Instructions

FULL SIZE PORT POWERED SWIPE READER TECHNICAL REFERENCE MANUAL

MOSQUITO HD VIDEO DRONE WITH LED LIGHTS. Item No User Manual

Quick Start TIME mode Set Time... 4 Set Alarm... 5

This product has been tested and certified to conform to ASTM F2456, Youth Resistant Firearms Container.

WAGNER MODEL L722 STACK PROBE OWNER S MANUAL

How Molekule Works. After two decades of research and development, a fundamentally new approach to air purification has arrived to your home.

VIDEO CAMERA DRONE WITH LED LIGHTS

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

WAGNER MODEL L722 "STACK PROBE" ATTACHMENT

Model 5000 Cargo Lift Installation and Operations Manual

4-UP QUICK START GUIDE SAVE THIS GUIDE FOR FUTURE USE.

W A R R A N T Y. mr.steam I Feel Good, Inc. I

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Instruction Manual V2.0. Instruction Manual. Laser Diode Drivers Models: LSP-500/1000/1500/-XK-XX

4-PIECE SHOWER WITH E-Z Pin INSTALLATION

Xxxxx Xxxxxx OM-CP-TEMP101A. Temperature Data Logger with 10 year battery life INSTRUCTION SHEET MQS5026/0117

SHOWER & TUB/SHOWER INSTALLATION

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

Installation Guide. Single AC or Dual AC Sump Pump Installation. 1 AC Primary Pump or 2 AC Pumps with Auxiliary Alternator

4-PIECE SHOWER & TUB/SHOWER w/ E-Z Pin INSTALLATION

Gold Bond brand /NGC. High Strength LITETM. Family of Products

DIGITAL PORTION SCALE PS-5 OWNER S Manual

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation

Model 5200 Cargo Lift Installation and Operation Manual

Stacker 1000 Operator Manual 701P98048

VLS User Manual. Patent Pending Hickory, NC 28601

KA 17. Compact Cash Drawer. Product Manual

U51. Operations Guide

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

Conversion Station Model 812

DLB-23 Shower Enclosure Installation and User s guide

Instruction Manual V2.0. Instruction Manual. High Power Laser Diode Drivers/High Voltage Pulser/ High Voltage Switch Models: LSP-500/1000/1500/-XK-XX

WEIGHT PER PIECE (LBS.)

Effective This guide supersedes all previous versions

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

user guide MEP moisture encounter plus

Shower Column SHCM Installation Guide

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

Stucco Moisture Inspection Report

INSTRUCTION MANUAL DAFM3

UNI BAR. user manual. ELATION UNI BAR user manual

PORTABLE CHAIR SCALES BEAM and DIGITAL TYPES MODELS 475, 4751, 6475, 6475k and 6475KGEU

user guide CME4 concrete encounter

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Installation Instructions. DuraTech 5" - 24" Chimney Shroud. DuraTech Shroud

Royal Sovereign RSL 2701 Laminator

DuraChimney II Shroud

USER MANUAL FOR MORE INFORMATION

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

DS-520 Digital Indicator Operation Manual 73366

DUST FREE ACTIVE Total Home Air Purification

Model M120 Mini Temperature/Humidity Meter

INSTALLATION MANUAL & Warranty Information

BIOVE PRODUCT REQUIREMENTS. A. Introduction. B. Installer Hazard Notification. A. Summary Of Key Requirements. B. Product Inspection T01-B

Model 5200 Cargo Lift Installation and Operation Manual

PORT POWERED SWIPE READER TECHNICAL REFERENCE MANUAL

1.0 STS-WiFi Operations Manual Outline

Limited Product Warranty

MERGE-8. 8 into 2 MIDI Merge Box. Operating manual

OWNER S MANUAL. Model 845. RFV Dye Marking System /15

NANO Q4 CAM PLUS NO. H002

I210 3G SmartMeter User Guide. SmartMeter System. I210 3G SmartMeter User Guide SMR B 1

INSTRUCTION MANUAL PHANTOM LOAD MODEL PA For SERIAL NO.

OM-CP-QUADPROCESS 4-Channel Low Level DC Current Data Logger. OM-CP-OCTPROCESS 8-Channel Low Level DC Current Data Logger INSTRUCTION SHEET

2020 Plus II. Instruction Manual

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00

Installation Instructions

VILLAGIO FLOORS, INC. TOLL FREE: Fax: VILLAGIOWOODFLOORS.COM. Finish Warranty. Structural Warranty

Global Water Instrumentation, Inc.

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

Finestone Stucco System

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: SWM-1 Loudspeaker Wall Mount Device. P/N: Rev 1

Global Water globalw.com. Global Water. Instrumentation, Inc.

INSTALLATION INSTRUCTIONS FOR BALCO, INC. TRENCH AND ACCESS COVER TSA/ACA-X-250 W/O LINER FOR CAST-IN-PLACE INSTALLATION

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL

PRELUDE K-8266T/K-8267T/K-8268T/K-8269T K-8270T/K-8271T/K-8273T/K-8275T QUIETUDE K-8262T/K-8263T

TT DataTran 162 SL Installation Guide

INSTALLATION PROCEDURE

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

Global Water Instrumentation, Inc.

Model E100 Gauss Meter

Infrared Digital Scouting Camera

Transcription:

Moisture Meter Instruction Manual Wagner Model BI 2200

Table of Contents INTRODUCTION...3 THE WAGNER METERS MOISTURE METER DEFINED...3 FEATURES...4 ON/OFF FUNCTION...5 INSPECTION FUNCTION...6 HOLD FUNCTION...6 MATERIAL SENSITIVITY RANGE...7 A RELIABLE METHOD TO INSPECTING WITH A MOISTURE METER... 9 FALSE ALARMS...10 AUTO SHUTDOWN...11 LOW BATTERY INDICATOR...12 METER STORAGE...12 BI 2200 METER SPECIFICATIONS...13 MATERIALS SETTINGS TABLE...14 FCC COMPLIANCE STATEMENT...15 WARRANTY...16 REPAIR SERVICE...19 2

Introduction The power of the Wagner Meters brand speaks loudly of the company s strategy of building superior products. Over the years, Wagner Meters has associated itself with some of the biggest names in construction materials. This means consistently delivering real value to customers. Wagner Meters initial success resulted from the technical superiority of its moisture measuring equipment, sold to those who were frustrated by the lack of innovation in moisture measurement. The Wagner Meters Moisture Meter Defined The basic concept underlying your moisture meter is its electromagnetic wave measurement feature technology. This allows you to perform a thorough survey quickly. The Basic Inspection Meter was specially designed to provide a quick 3

general moisture indication for many different industries who only require relative readings. Features Uses Wagner s non-invasive patented electromagnetic wave technology Selectable material range includes wood, tile, shingles, plaster, drywall, linoleum, fiberglass, veneer, synthetic stucco, roofing, siding, insulation materials, and more. Teflon abrasion pad protects sensor plate from abrasive surfaces 1 Hold feature allows you to freeze readings on the display Large, bright digital display Smart autopower off saves battery life Footnote: 1 Note that the meter sensor is covered with a self adhesive replaceable Teflon abrasion pad. Replace Teflon pad when worn through to sensor, or when edges or corners loosen. Do not use the meter with debris under a loosened edge or corner. Replacement Teflon pads are available by calling Wagner Customer Service (541) 582-0541. 4

Compact pocket-size design Rugged design User-friendly 2-button operation Low battery indicator Complete with 9-volt battery and protective holster Factory-direct technical support Light weight and compact design On/Off Function ON/ HOLD The ingenious 2 button control panel makes the operation of your moisture meter easy, especially if your hands are full. Turn on the meter by pressing the left button. The firmware version 2.2.0 will appear briefly on the screen as the microcomputer is initializing. You can turn off the meter by pressing down on the On/Hold button for 3 seconds 5

otherwise automatic turn off will occur after one minute if the meter is not in use. Inspection Function ON/ HOLD Turn on the meter (the firmware version 2.2.0 will appear briefly). Set the meter on the material to be scanned. Press down firmly on the center of the meter with approximately 3 pounds of force to ensure good sensor plate contact. Observe the number displayed on the screen. Hold Function ON/ HOLD When the meter is in the inspection mode, and the On/ Hold button is momentarily pressed and released, it will enter Hold mode to allow the user to freeze the moisture reading. 6

A ( ) symbol will appear on the left side of the screen. This will indicate the hold mode. To clear the screen, press the On/ Hold button again. Material Sensitivity Range M There are three ways to use the material sensitivity range feature. 1. You can use the factory setting of :50 for the moisture measurement of many materials. No adjustment is needed. 2. Before you scan a very dense material such as concrete or cement, change the material setting to 1:00. Remember to reset the number to :50 when done measuring this type of material. To operate the material sensitivity range feature, turn on the meter; when the 7

firmware version 2.2.0 clears from the screen, press the M button. The meter display will show the current material setting. The factory preset number is :50. Press the M button a second time. The colon (:) will blink, indicating that you are in the change mode. Next, hold the M button down to increment the material setting by :10. The value will go as high as 1:00, then will wrap around to :20 and continue incrementing. When the desired setting has been reached, release the M button and then press the On/Hold button to store the material setting and return to Inspection mode. For a list of suggested material settings, see the Material Settings Table section in this manual. 3. The BI 2200 meter has a feature to allow you to fine tune your moisture meters readings for many different 8

materials. This is a feature that may not be needed by most users. If you would like to adjust the material sensitivity range anywhere between :20 to 1:00 for customized projects you may use the instructions outlined above. (Note: You may press the M button to increment the selected material setting by :01 or hold the button down to increment by :10). A Reliable Method To Inspecting With A Moisture Meter Compare dry to wet readings, one material at a time. For example, before a wall stain is scanned by the meter establish a base line reading on the meter at a section of the same wall that is known to be dry. This reading is the base line of comparison. Next, take readings at the stain area and compare to the base line reading. Elevated 9

readings at the stain, compared to the base line can indicate elevated moisture near the stain area. False Alarms Your moisture meter may respond to metal in a wall as it would to an increase in moisture content. To determine if the elevated readings are caused by metal, scan in the direction of a straight line, horizontally, then vertically away from the point where you obtained elevated readings. Notice if the meter is responding to what may be a piece of metal or wood stud rather than an area of elevated moisture. By observing the shapes of the elevated reading area you may obtain clues as to whether the readings are from moisture or from metal such as a pipe or copper wire. Be aware of hidden metal objects that are used in construction. Common examples 10

are steel frames that join drywall at corners (bead and trim), fasteners, flashing and metal channels. You do not need to be concerned with metal at depths greater than 1 inch to 1 1 / 2 inch from the surface being scanned. Please note that as you scan across studs, the readings will be elevated due to the higher density of the stud vs. the void and the insulation space. The above guidelines also apply when measuring flooring material over concrete or plywood. Your meter may respond to these types of materials as it would to an increase in moisture content. Auto-Shutdown The meter will automatically shutdown in 60 seconds when the meter s moisture reading has not changed by more than 2, and none of the meter buttons have been pressed. The shutdown timer will reset anytime the meter reading changes or a button has been pressed. 11

Low Battery Indicator When the LO BAT indicator is on, you should replace the battery to insure the meter will function properly. If the battery needs to be replaced, use a 9-volt alkaline battery. Be sure to observe proper battery polarity. Meter Storage For a long service life, it is important to store your meter properly. Avoid excessively hot or cold locations, and keep the meter in the case provided. Do not store the meter in an area with excessive electro-magnetic interference, such as near an electric motor, or where it could be crushed. 12

BI 2200 Meter Specifications Size: Length Width Height Scanning Area: Length Width Scanning Depth: Weight: Power: Auto Shut Down: 4 9 / 16 inches 2 3 / 4 inches 1 1 / 16 inches 2 1 / 2 inches 1 1 / 2 inches 3 / 4 inch 0.37 pounds 9 volt alkaline 60 seconds 13

Materials Settings Table These material settings are provided to give users general correction factors for various construction materials. Material Setting Material :50 Boat Structures (Fiberglass) 1:00 Brick :50 Ceramic Tile 1:00 Concrete :50 Drywall / Sheetrock :50 Engineered / Laminated Wood :50 Fiberboard / Particleboard :50 Flooring (Wood) 1:00 Gypsum :50 Insulation Materials 1:00 Mortar :50 Plaster :50 Roofing :50 Siding (Wood) :50 Stucco (Synthetic) :50 Veneer :50 Wood 14

FCC Compliance Statement This equipment has been tested and found to comply within the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television equipment reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Move the equipment away from the receiver. Plug the equipment into an outlet on a circuit different from that to which the receiver is powered. If necessary, the user should consult the dealer or an experienced radio/ television technician for additional suggestions. CAUTION: Only equipment certified to comply with Class B (computer input/ output devices, terminals, printers, etc.) should be attached to this equipment. Finally, any changes or modifications to the equipment by the user not expressly approved by the grantee or manufacturer could void the user s authority to operate such equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. Canadian Department of Communications compliance statement This equipment does not exceed class B limits per radio noise emissions for digital apparatus, set out in the Radio Interference Regulation of the Canadian Department of communications. Operation in a residential area may cause unacceptable interference to radio and TV reception, requiring the owner or operator to take whatever steps are necessary to correct the interference. Avis de conformité aux normes du ministère des Communications du Canada Cet équipement ne dépasse pas les limites de Classe B d émission de bruits radioélectriques pour les appareils numériques, telles que prescrites par le Réglement sur le brouillage radioélectrique établi par le ministère des Communications du Canada. L exploitation faite en milieu résidentiel peut entrainer le brouillage des réceptions radio et télé, ce qui obligerait le propriétaire ou l opérateur à prendre les dispositions nécessaires pour en éliminer les causes. 15

Warranty Wagner Meters warrants this product against defects in material and workmanship for one (1) year from the date of purchase, subject to the following terms and conditions: Wagner Meters liability under this warranty shall be limited, at Wagner Meters option, to the repair or replacement of this product or any part thereof, which is demonstrated to be defective. To exercise this warranty, visit www.wagnerrepairs.com for instructions. This limited warranty does not apply if the product has been damaged by accident, negligent handling, misuse, alteration, damage during shipment, or improper service. Wagner Meters shall in no event be liable for any breach of warranty or defect in this product, which exceeds the amount of purchase price of the product. Wagner Meters shall not be liable for 16

incidental or consequential damages for the breach of any express or implied warranty with respect to this product or its calibration. With proper care and maintenance, the meter should stay in calibration; however, because Wagner Meters has no control over the manner in which the unit will be used, it makes no warranty that the meter will stay in calibration for any specific period of time. Factory recalibrations are not covered under this warranty. This warranty is in lieu of all other warranties, whether oral or written, express or implied. Any implied warranties, including implied warranties of merchantability and fitness for a particular purpose, are excluded. Agents and employees of Wagner Meters are not authorized to make modifications to this warranty or additional warranties binding on Wagner Meters. Accordingly, 17

additional statements, whether oral or written, except written statements from an officer of Wagner Meters do not constitute warranties and should not be relied upon by the customer. This warranty is personal to the customer purchasing the product from Wagner Meters and is not transferable. 18

Repair Service In the event of damage, failure, or if the unit requires re-calibration, contact Wagner Meters Technical Services Department at www.wagnerrepairs.com or by phone for complete shipping information. The values stored in memory may be lost in the event that the meter is sent in for repair. * If parts are unavailable to repair we reserve the right to replace the meter with an alternative model with equal or better accuracy and range 19

2017 WM Wagner Meters Part # 500-02200-001 Rev. C Wagner Meters 326 Pine Grove Road, Rogue River, OR 97537 USA Phone: (541) 582-0541 Fax: (541) 582-4138 E-mail: sales@wagnermeters.com Visit Our Moisture Measuring Information Center at: www.wagnermeters.com