ADVANCED SOFTENING MATERIAL. for problem water. SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium

Similar documents
ADVANCED SOFTENING MATERIAL FOR PROBLEM WATER

DW Module 22 Inorganic Removal Basics Answer Key

Valve Nest Filter with Time Clock Control Installation and Operation Manual

Watch Water. ANSI/NSF 61 Certified From. February 2014

Overview. Commercial High-Purity Water Systems and Applications. Quality Water Is Our Business

Filtration & Pretreatment Basics

Water Treatment & Purification Chemicals

DISTRIBUTION TECHNOLOGY SAVES WATER. SAVES SALT. SAVES THE ENVIRONMENT. Where Innovation Flows

SECTION 5 E-Treat Water Conditioning Systems

SALT EFFICIENCY FOR SOFTENER REGENERATIONS. Presented. ALBERTA Public Works, Supply and Services Management Division. Ft. Saskatchewan, Alberta

PERFORMANCE DATA SHEET Water Conditioning Systems

PERFORMANCE DATA SHEET Water Softening Systems

TREATMENT OF WATER. A.Sateesh Chemist State Level Laboratory

PERFORMANCE DATA SHEET Powerline Water Conditioning Systems

How to Choose a Water Softener. Brought to you by

IRON, MANGANESE AND HYDROGEN SULFIDE IN PRIVATE WATER SUPPLIES

PERFORMANCE DATA SHEET Water Conditioning Systems

The Iron Curtain Filtration System

Water supplied by Marafiq does not meet the process requirements.

3/25/2015. MARCH 24, 2015 Chad T. Olsen, P.E., BCEE. WRWA 27 th ANNUAL TECHNICAL CONFERENCE. City of Chilton, Wisconsin. Chilton.

Programming Manual 85HE PROGRAM GUIDE

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal

Demineralization (RO, NF, UF, MF, ED, IE)

Water Treatment. Water Conditioning Parts - Aquatrol Pressure Tanks

Understanding Reverse Osmosis Mark Rowzee Mark Rowzee

Household Water Treatment

City of Woodbury. Red Bank Water Treatment Plant - Treatment Alternatives Analysis November 2016

INDUSTRIAL SEPARATE BED DEIONIZER. FDI Series. High Purity Industrial Packaged System

ISR (IRON SPECIFIC RESIN)

KDF Process Media. Improve the performance and economy of your water purification system.

Solving Water Problems

MAINTAINING DRIP IRRIGATION SYSTEMS

Evaporative Condenser Passivation. Cameron Klein Strand Associates, Inc.

EVERPURE COMMERCIAL WATER SOFTENING PRODUCTS FOODSERVICE

C-100E Strong Acid Cation Exchange Resin (For use in water softening applications)

REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION

CR-200 ZEOLITE SIZE SPECIFICATION

Exeterline. R.E. Prescott Company Water Treatment Catalog. Enter a World of Cleaner Water.

POWER OF PURITY ecosoft.com ABOUT THE COMPANY

CR-200 CHARACTERISTICS

DOWEX UPCORE Ion Exchange Resins Retrofit of Demineralizer with UPCORE System Cuts Chemical Costs by 50%

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

Rectangular Basin = Volume, gal (Length, ft) x (Width, ft) x (Height, ft) x7.48 gal/cu.ft.

Specific Gravity 2.69 Minimum Bed Depth 24 Inches (600mm) Effective Size Freeboard 40% minimum Uniformity Coefficient 1.4 Service Flow Rate

WATER FILTRATION EQUIPMENT LWF Series Commercial Water Filters

A-300, A-300E Strong Base Type II Anion Exchange Resin

C-100H Strong Acid Cation Exchange Resin in Hydrogen Form (For use in water demineralization)

Water Treatment Solutions A - Z

Cover. Pressure Filters

Cover. Pressure Filters

Kinetico SIGNATURE. Owner s Manual. Guide d utilisation. Manual del usuario WATER SOFTENERS SERIES

WEFTEC.06. Lake Okeechobee, Actiflo, peroxone, surface water, Cyanobacteria

Commercial Catalog. 11th Edition

Treatment of all source water influent & effluent for user application, be it commercial, industrial, domestic, to defined & required standards.

COMMERCIAL WATER SOFTENER LWTF SERIES

Advanced water purifier system operation manual and setup guide

Use of Spiral Wound UF in RO Pretreatment

WATER RECYCLING SOLUTIONS

SST-60 Salt Saving Technology Softening Resin

PERFORMANCE DATA SHEET Kinetico Water Filtering Systems

Membrane Technology: From Manufacture to. May Production

Feed Water Reduction in Industrial Water Purification Systems

Clear Solutions from your Culligan Man for Complicated Water Problems

Technical Data. Typical Chemical & Physical Characteristics

SRO-300 INSTALLATION MANUAL

Industrial / Municipal

5.B Generation of pharmaceutical water Author: Michael Gronwald Co-Author: Dr. Ralph Gomez / Up06

from the water treatment specialists

On-Site Sodium Hypochlorite Generation Equipment

Treatment of Coal Bed Methane Produced Water Using Short Bed Ion Exchange MICHAEL SHEEDY AND PAUL ROBINSON, Eco-Tec Inc., Pickering, Ontario

1000 GPD Marlin Reverse Osmosis Instruction & Owner s Manual

Produced Water Treatment Systems

Distributed by: Phone: , Toll-Free U.S. Fax: , Toll-Free U.S.

Lecture 1: Introduction

Maintenance of Drip Drip Irrigation Systems. Patrick Byers Regional Horticulture Specialist University of Missouri Extension

MANUAL DUAL MEDIA FILTER (MILD STEEL)

Reverse-osmosis membranes were

Hybrid RO & Softening Birjand Water Treatment Plant

SHORT BED ION EXCHANGE TECHNOLOGY PRODUCES ULTRAPURE WATER WITHOUT USING A MIXED BED

Aqua Pristine Global Technologies, an ISO 9001:2008 & CE certified company is a leading supplier of world class Domestic RO, Industrial RO Plant,

KTDA SEMINAR WATER TREATMENT PRESENTATION. John Waema

Water softening and scale prevention

SRO-1000 SRO-2000 SRO-4000 INSTALLATION MANUAL US 33 N. Churubusco, IN Ph. (260) Fax (260)

Water Quality. CE 370 Lecture 1. Global Distribution of Earth s s Water

WATER CONDITIONING & ENVIRONMENTAL PROTECTION

Creating SDI Solutions WATER TECHNOLOGIES

1. Inspection and monitoring... 3

Fresh water may come from either a surface or ground source and typically contains less than 5 000ppm TDS.

KEYWORDS: Ion exchange, compressed short bed, wastewater, filter, secondary water, tertiary water, reverse osmosis (RO), electrodeionization (EDI).

World-Class Equipment & Process Expertise WDI Marketing Package INCLUDED DOCUMENTS. For more information visit

PERFORMANCE DATA SHEET Drinking Water System A200. A200 Drinking Water System

Operation & Maintenance Manual

Water and Wastewater Engineering Dr. Ligy Philip Department of Civil Engineering Indian Institute of Technology, Madras

Purification of Brackish Water using Hybrid CDI-EDI Technology

Sustainability in commercial laundering processes. Module 1 Usage of water. Chapter 3b. Water softening

Softener Owners Manual Manuel Utilisateur Manual del usuario Model

Concentration mg/l TDS mg/l 10, ,000 Recovery 75% Waste TDS mg/l 44,000 COD mg/l 3,500 0 BOD NTU 1,250 0 Power Used kwh/m3 2.

the faculty for factory program (FFF), Jordan

July 1977 Subject: Technical Letter 26 Removal of Water Supply Contaminants Chlorophenoxy Acid Herbicides

PUR-1241 ADDENDUM NO. 2 INVITATION TO BID GREENSAND FILTER SYSTEM AT ELK RIDGE WATER TREATMENT PLANT

Transcription:

ADVANCED SOFTENING MATERIAL for problem water SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium Used by water treatment companies globally since 1998 AMERICA

WHAT ECOMIX IS ECOMIX is a scientifically grounded technology, confirmed by 6 patents and service world-wide since 1998. ECOMIX works effectively in well water and municipal water within the allowable concentrations of iron and manganese, hardness and natural organic matter (tannins). ECOMIX consists of five ingredients, including two patented materials. 82 materials researched 1998 developing and patenting Ecomix 6 patents ECOMIX reduces: hardness iron manganese natural organic matter (including tannins) ammonium Certified in compliance with the NSF/ANSI 44/61/372 standards

HOW ECOMIX WORKS Delivered and loaded as homogeneous media Top basket Stratifies into five layers after regenereation Regenerates with softener plain salt * Do not use resin cleaner salt or chemicals Inert layer enhances backwash FerroSorb unique reduces iron and manganese compounds HumiSorb unique reduces natural organic matter (tannins) and organic iron Cation exchange resin softens water * Potassim chloride at a higher dosage can also be used Gravel ensures uniform flow across the vessel Bottom basket 3

REDUCING IRON AND MANGANESE FerroSorb is a proprietary sorption material for iron and manganese reduction Dissected FerroSorb bead Mechanism of iron and manganese reduction ADSORPTION OXIDATION ACTIVE LAYER FORMATION AUTOCATALYTIC OXIDATION This chain works to reduce iron in the dissolved ferrous form (clear water iron). The surface layer of FerroSorb contains active sites for reduction of manganese. For best resuts pre-treat with a sediment filter only. Aeration and oxidative pre-treatment should be avoided. Treat iron bacteria before installing ECOMIX. 4

REDUCING ORGANIC MATTER HumiSorb is a proprietary sorption material for reduction of natural organic matter (reduces color and tannins) Fresh HumiSorb beads HumiSorb beads after service Tannins and organic iron are reduced due to hydrophobic and electrostatic interactions with HumiSorb. Check the tannins concentration before using ECOMIX when tannins reduction is desired. ECOMIX is intended for the treatment of well water and chlorinated municipal water from tannins. ECOMIX is not designed for the treatment of surface water (lakes, ponds, rivers, swamps etc). Water from a shallow well located close to the surface water should be checked for tannins concentration and microbiological safeness. Microbiologically unsafe water cannot be treated by ECOMIX. 5

ECOMIX REGENERATION ECOMIX is regenerated with the same steps as typical water softeners: backwash, brine, rinse. Calcium and magnesium ions are displaced from the cation exchange resin matrix with sodium ions. Iron and manganese compounds are reduced by surface friction of FerroSorb beads in the fluidized bed during backwash. HumiSorb exhibits a reversible mechanism of sorption of organic molecules, and is regenerated with chloride ions. 6

ECOMIX EFFICIENCY AND LIMITATIONS Raw water quality requirements and efficiency of purification Raw water limitations Max. efficiency, % Hardness 45 gpg 97 Iron 15 ppm 98 Manganese 3 ppm 98 TOC* (including tannins) 17 ppm C 80 Ammonium 4 ppm 90 *TOC (total organic carbon) is used as a measure of natural organic matter content OPERATING CONDITIONS: ph 5 9 No limits on influent hydrogen sulfide or anion content Active chlorine 1 ppm TDS 4000 ppm 7

ECOMIX TECHNICAL SPECIFICATIONS When designing ECOMIX units, refer to the following figures: Parameter Value Service flow rate 8-10 gpm/ft 2 Backwash flow rate 4-6 gpm/ft 2!!! Brine (slow rinse) flow rate 1.2-2.0 gpm/ft 2 Minimum bed depth 20 inches Recommended bed depth 30 inches Freeboard 40% or more Ion exchange capacity 13,000 grain/cu.ft. Salt consumption 6.3 lbs/ft 3 Brine concentration 8-10% Water consumption per regeneration less than 75 gallon/ft 3 Rust removal, resin cleaner salt, and chemicals will affect ECOMIX performance. If using potassium chloride increase salt dosage to 9 lbs/ft 3. ECOMIX does not affect ph. 8

COMMONLY USED VESSELS BAG HALF BAG Size of vessel 1035 1054 1252 1354 1465 1665 2162 ECOMIX volume, bags* 1.0 1.5 2.0 2.5 3.0 4.0 6.0 Service flow rate, gpm 5.7 5.7 8.0 10.0 11.0 14.5 24.3 System capacity, grains 11,500 17,000 23,000 28,500 34,500 46,000 69,000 Salt per regeneration, lbs. 5.5 8.4 11.0 13.7 16.5 22.0 33.0 Backwash flow rate, gpm!!! 2.7 2.7 4.2 5.3 6.5 7.5 11.3 *ECOMIX is supplied in two size types: Bag - 0.88 cu. ft. (25L) Half bag - 0.42 cu. ft. (12L)!!! Pay attention to the backwash flow rate and choose the right drain line flow control (DLFC). Visit ecomix.us to use the ECOMIX calculator. 9

VOLUME CAPACITY OF ECOMIX UNIT Volume capacity can be calculated using just influent hardness and ECOMIX system capacity. Volume Capacity, gal= System Capacity, grains Raw water Hardness, gpg Average service life is 5 years No need to compensate raw water hardness for iron and manganese concentration when calculating volume capacity. 10

ECOMIX INSTALLATION SCHEMATIC Treated water Feed pressure 40-60 psi recommended Input water hardness in control valve settings Raw water Regenerate after installation Sediment pre-filter PP cartridge filter for clear water *For water with high turbidity and iron content (over 10 ppm) application of filter with Filter Ag media is recommended Drain line tube diameter equal to value drain connection and should not exceed 8 ft. If longer, increase drain line tube diameter 11

ECOMIX IN A RESIDENTIAL ENVIRONMENT STANDARD SOLUTIONS MULTISTAGE SOLUTIONS 1 2 3 1 2 3 1 Sediment filter for sand, rust and silt reduction 2 Ecomix system for hardness, iron, manganese, natural organic matter & ammonium reduction 3 Сentaur carbon system 1 2 3 for hydrogen sulfide reduction 1 2 2 3 12

ECOMIX IN COMMERCIAL AND INDUSTRIAL APPLICATIONS ECOMIX is used to treat raw water supplied to reverse osmosis systems, to soften and reduce iron from boiler feed water, to purify domestic water in hotels, apartment buildings and business centers. 13

ECOMIX PRODUCTION ECOMIX is manufactured in Germany The manufacturing process includes surface activation of FerroSorb and HumiSorb. Digital control of ingredient mixing ensures consistent quality of finished product across batches. ECOMIX is certified in EU for compliance with LFGB requirements for foodcontacting materials by TÜV SÜD. ECOMIX is certified in compliance with NSF/ANSI standards: - NSF/ANSI 61 Drinking Water System Components Health Effects - NSF/ANSI 44 Residential Cation Exchange Water Softeners - NSF/ANSI 372 Drinking Water System Components Lead Content Scheme 14

ECOMIX SUPREMACY 100 % success rate up to10 years service life Most reliable technology for removal of iron and manganese Highest permissible concentration of iron and manganese Smallest regeneration salt requirement Consistent quality of purified water throughout service life ECOMIX is not only a unique water treatment technology. It has been a firm platform for the corporate success of numerous companies around the globe. 15

SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium ECOMIX is certified in compliance with NSF/ANSI standards ECOMIX is certified in EU by TÜV SÜD meets the requirements LFGB ResAP(2004)3 EU Guideline 2002/72/EG Ecosoft Water Systems GmbH www.ecosoft.com www.ecomix.us Ecosoft 02-02-2017