Fielders Steel Door Frames. Architectural and Commercial

Similar documents
Metal Door Frames & Meter Boxes

BETAFRAMES. Engineered products for the building industry Solutions without compromise. Industry Knowledge. Flexible Manufacturing.

B. ASTM A 153/A 153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware; 1998.

Rytec Corporation One Cedar Parkway Jackson, WI GO-RYTEC (262)

HOTEL SPECIFICATION SECTION 08100

2003 International Residential Building Code

Masonry Veneer - Chapter 6. Masonry Veneer Anchored Veneer

Stone and Masonry Veneer

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

Fire Rated Glazing System Guide

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

Wet Areas Using Plasterboard

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SECTION NON-STRUCTURAL METAL FRAMING

DETAILED METAL DOOR SPECIFICATION. UNIVERSITY CONTACT: Mark Golden, Supervisor of Structural Services (302)

SECTION NON-STRUCTURAL METAL FRAMING

SECTION METAL DOORS & FRAMES

SECTION 5: BUILDING TRADES CONTENTS

Bullet Resistant Doors P/N BRD_

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

Table of Contents. Introduction 1-5. Standard Metal Door Frames 8

Product Description. Standard Sizes and Hardware Locations

SECTION CHAIN LINK FENCES AND GATES (PARK)

Wall Ties. Differential Movement In Timber Frame

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

SVG+ (Triple Track) Product Manual

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

SECTION ALUMINUM HANDRAIL SYSTEMS

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

SECTION HOLLOW METAL DOORS AND FRAMES. A. Section includes steel doors and frames (hollow metal) indicated and as specified.

Smart Panel System The Health Care Specialist

SECTION ORNAMENTAL ALUMINUM FENCING

Concrete Soffit Direct Fix

SECTION STEEL DOORS AND FRAMES

SUBMITTAL PACKAGE CUSTOM HOLLOW METAL DOORS, FRAMES AND WINDOWS

Aluminum-Framed Entrances and Storefronts

END ELEVATION FRONT ELEVATION. LEG (inside view) TOP (1:20) FOOT - FIXING DETAIL (1:5) (1:20) CONSTRUCTION STANDARD

SECTION ORNAMENTAL WELDED STEEL FENCING

Superior quality, a strong service commitment, and value are DKS watch words. Standard features built

HOME SYSTEMS CONSTRUCTION PROCEDURE

LLOYD INDUSTRIES INC. DAMPER INSTALLATION INSTRUCTIONS

UNIVERSAL. Weight Max Panel Weight: 130kg. Parameters Panel Width: Max 1300mm Glass Thickness: 8-12mm

Series 729 Thermally Broken Hinged Door DESIGNER SERIES THERMAL HEART

SECTION NON--STRUCTURAL METAL FRAMING

FIRE RESISTANT GLAZING SYSTEMS 8

Brick Masonry. Best Practices Guide

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

Floor Plan. *The floor plan represents a section view of a residence which has had an imaginary cut made approximately 4 feet above the floor line.

MASPORT I5000 INSERT FIRE, AUSTRALIAN MODEL

deceuninck 2500 chamfered series

CWCT CURTAIN WALL INSTALLATION HANDBOOK

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

INDEX General Information Flush Frames Drywall Frames Technical Data Sheets Anchors

AMBICO Limited Section and ACOUSTIC STEEL DOOR AND FRAME ASSEMBLIES Page 1

Trend Synergy Aluminium Sliding Stacker Door TECHNICAL DATA

AA Series 90mm Frame Windows (Operated Casement Window Illustrated)

SERIES 487 CENTER GLAZED SLIDING DOOR WITH 1-1/2" TRIM

Weep vents on the outer leaf should be installed in accordance with standard masonry practice O O P P. Example load ratio 2:1-1:5

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Design Guide Revised 11/17/2016

Installation Instructions

Quantum Sliding Window. Features & Benefits. Trend Windows & Doors Design Manual Q-Mk-1 May 2014

B. Provide fire-rated access doors where indicated or scheduled.

Missouri S&T Bullman Showers Date: February 13, 2017 Project No SECTION PLASTIC SHOWER AND DRESSING COMPARTMENTS

ES2 integrated screening system for bifold doors

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START

SECTION TOILET PARTITIONS. A. Section Structural Steel: Supports for ceiling hung compartments.

SECTION DETENTION WINDOW SCREENS. 1. Detention screens for interior and exterior installations at exterior windows in existing buildings.

CERTIFICATE OF APPROVAL No CF 535 HALSPAN LIMITED

1. Include plans, elevations, sections, details, and attachments to other work.

Halfen systems for the support and restraint of brickwork

RATING: Consult factory for availability Consult factory for availability

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

STEEL WINDOWS & DOORS SECTION 08510

GUIDE SPECIFICATION Los Angeles World Airports SECTION HOLLOW METAL DOORS AND FRAMES

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses. DD No

The Australian Catalog Content is compiled by Cadsoft Australia, for any further information contact:

Composite / Veneer Units. Precision...1. Split Face... 2

1600 WALL SYSTEM 2 ESTIMATING/TAKE-OFF AND ORDERING GUIDE (16 Pages) E.C.# (09/09/13)

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

INDIGATECH CERTIFICATION SCHEDULE

Post Style with ABS Real Tuff

Note on the assessment:

SECTION MASONRY ACCESSORIES

5.0 NUDURA PRODUCTS ON SITE STORAGE PACKAGING, UNIT ASSEMBLY, USAGE

RESIDENTIAL GATE FRAMES MADE WITH 17 GA DOMESTIC PIPE

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

Specifications PRE ASSEMBLED DOOR SPECIFICATION PART 1 GENERAL 1.01 SUMMARY

Guide to using the Ultimate Building Block

Building Division Informational Handout

BRICK CONSTRUCTION DETAILS

A. Minimum Thickness: Minimum thickness of base metal without coatings according to NAAMM-HMMA 803 or SDI A250.8.

Transcription:

Fielders Steel Door Frames

The Fielders Steel Door Frame is a strong and durable solution, made from 100% Australian steel by BlueScope. We offer an extensive range of standard sizes and a complete custom manufacture service. Our in-house estimators can do a take off from your plans. Projects suitable for Fielders Steel Door Frames include: Residential buildings. High-rise commercial buildings. Education, retail and health projects. Fielders can assist with your next project, through: An in-house estimation service for commercial projects. Just send us your plans and we do the rest. Technical literature and collateral. Fielders Steel Door Frames offer a robust, durable and in certain circumstances, a structural solution for any type of project. Custom Options Fielders Steel Door Frames can be fabricated with the following options: Screwfix backing plates Galvanised Steel Stainless Steel Provision for electric opening Provision for door closers Provision for transoms and mullions

Typical Door Frame Detail Standard Profiles Factory assembled with mitred corners. Welded and smooth finish. Neatly mitred welded joints Striker with Mortar Guard Standard Door Frame Sizes and Stud Sizes AUST. STANDARD DOOR SIZE (mm) DOOR FRAME REVEAL SIZE (mm)* OVERALL FRAME SIZE (mm) STUD OPENING SIZE (mm) SINGLE DOORS 2040 x 520 2060 x 523 2100 x 603 2080 x 555 Masonary Anchor or tie 2040 x 620 2060 x 623 2100 x 703 2080 x 655 2040 x 720 2060 x 723 2100 x 803 2080 x 755 2040 x 820 2060 x 823 2100 x 903 2080 x 855 Customisable Striker height 2040 x 920 2060 x 923 2100 x 1003 2080 x 955 DOUBLE DOORS Foot Plate if required Butt Hinge for fixing door. 100mm x 75mm, Zinc Plated. 2 per frame unless otherwise nominated. (Hinge is spot welded onto frame) 2040 x 2/520 2060 x 1043 2100 x 1123 2080 x 1075 2040 x 2/620 2060 x 1243 2100 x 1323 2080 x 1275 2040 x 2/720 2060 x 1443 2100 x 1523 2080 x 1475 2040 x 2/820 2060 x 1643 2100 x 1723 2080 x 1675 2040 x 2/920 2060 x 1843 2100 x 1923 2080 x 1875 NOTE: It is recommended to add required clearances to this dimension* 4 5

Frame Dimension Measurements X = Flange return Y = Back opening V = Door stop depth (13mm) Z = Architrave W = Door rebate Stud Fixing Details Brick Veneer Wall 20mm Stud channels (welded) Stud strap (welded) 4mm diameter wire tie Closed Cavity Wall Selecting the Correct Opening Masonry Fix details Left-hand swing Right-hand swing Double Doors Sliding Doors Transoms and Sidelights Custom transoms and sidelights can be fabricated as required. Typical designs: Fielders built-in Corrugated offset strap 4mm diameter wire tie 4mm diameter wire tie Fielders built-in Corrugated straight strap Double Brick or Concrete Double Brick Single Wall Single Wall Block wall with Door Frame fitted centrally cavity wall with Plaster inside with brick or block with brick or block 6 7

C/Sk holes (A) Into existing masonry C/Sk holes (B) With sleeves and straps into existing masonry Fielders Door Frame EXISTING MASONRY Timber Packers EXISTING MASONRY DYNABOLT FIXING BY INSTALLER 15mm Centreline 10mm 10mm countersunk hole Galv. Steel Sleeve Galv. Steel Straps welded to flanges DYNABOLT FIXING BY INSTALLER Note: Mortar guards are fitted to all cutouts when using C/Sk holes 8 9

How to Order 1. Specify Back Openings 95mm internal brick walls. 114mm single brick external walls or feature brick walls. 2. Specify Frame Size Internal Dimensions When ordering always specify the opening height and width of the opening eg. 2060mm x 820mm. Fielders will supply a frame with an opening to height and 3mm greater in width. 3. Specify Left or Right Hand Side Always stand with the door opening towards you. The side with hinges is how the hand is determined. 6. External Doors When ordering an external frame always supply the following information: i) Is the frame left or right hand? ii) Is the frame to be fitted to the internal or external brick of the wall? iii) Is the door to open in or out? External Leaf Left hand open in with flashing to outside leaf Door Internal Leaf 4. Hung Doors When ordering always specify the total width of the combined opening. For example, a frame to suit two 820mm doors will be specified as 2360mm x 1644mm. If fixing to external double brick walls, a flashing will be required to protect the cavity. 5. Robe Frames Robe features can be specified as: Standard height - 2060mm - with other heights available on request. All door robe frames have a spacing fixed to the bottom sill. Standard height (2060mm) robes have two hinges per door whilst full height robes (2320mm) have three hinges per door. A steel shelf rail is supplied only if requested and is fitted 1700mm above floor level. Always state the number of doors required - eg 2060mm x 2/720mm robe. If there is a single door, always state whether it needs to be a left hand or right hand single door. NOTE: If fixing to external double brick walls a flashing will be required to protect the cavity. 7. Toilet Doors Fielders will fit door frames with lift off hinges. When specifying, identify these openings with the abbreviation WC - eg 2060mm x 620mm LH WC. 8. Striker Plate Height Plates are typically located 1000mm from the center to floor level, however these can be customised for commercial frames. 9). Standard Abreviations - GLOSSARY Hand Slider Toilet Doors No Striker Double Hung RH or LH SL WC NS DH 10 11