AmpF STR NGM PCR Amplification Kit - Overview

Similar documents
Data Quality Worth Sharing

Upgrading the Workflow: Enhancing Information Recovery from Forensic Evidence. The world leader in serving science

AmpFlSTR Identifiler PCR Amplification Kit

HID Validation: The 3500 Series Genetic Analyzers

GlobalFiler Kit Casework Test Site Results and Other Development Updates

Development and Validation of the 3500 Series Genetic Analyzer for Human Identification

First Look: Applied Biosystems NGM Detect PCR Amplification Kit

Development of a Global STR Multiplex for Human Identification Analysis

User Bulletin. Veriti 96-Well Thermal Cycler AmpFlSTR Kit Validation. Overview

Artifacts Identified Post-Developmental Validation: AmpFLSTR Identifiler Plus PCR Amplification Kit

DNA Typing Strategy for the Identification of Old Skeletal Remains

Product Catalog 2012 AmplGen Ltd.

DNA Typing for the Identification of Korean War Victims

Developmental Validation of Amplicon Rx, a post-pcr Purification System

Investigator Quantiplex HYres Kit

GlobalFiler TM Extra Cycle Evaluation Report

Development of a Global STR Multiplex for Human Identification Analysis

Development of a Global STR Multiplex for Human Identification Analysis. Julio Mulero, Ph. D. R&D Group Human Identification, Life Technologies

Genetic Identity. Steve Harris SPASH - Biotechnology

QIAGEN Validation Report

PowerSeq 46GY System Eases the transition to MPS for forensic laboratories

QIAGEN Validation Report

Introducing: The AmpF STR NGM SElect Express Kit From Sample to Result in 2 Hours*

PowerPlex ESX & ESI Fast Systems

Developmental validation of the Investigator Argus X-12 QS Kit

Direct PCR Amplification of Blood Samples on Copan NUCLEIC-CARD TM Systems Using the AmpFlSTR Identifiler Direct PCR Amplification Kit

STRmix Implementation and Internal Validation Erie County Central Police Services Forensic Laboratory

A comparative performance evaluation of illustra Ready-To-Go GenomiPhi V3 and illustra GenomiPhi V2 DNA amplification kits

What is DNA? Deoxyribonucleic Acid The inherited genetic material that makes us what we are

The Evolution of Direct Amplification: From Sample to Result in 2 Hours*

STRmix Implementation and Internal Validation-FUSION. Erie County Central Police Services Forensic Laboratory

Design and Execution of Validation Studies for Establishing DNA Mixture Interpretation Procedures

Latest Tools for Human Identification

Report of Analyzing Short Tandem Repeats for Parentage Testing

STR Profiling Matching Criteria: Establishment and Importance of a Cell Line Database

Procedure for Casework DNA Interpretation

Forensic Applications of CE and MPS

QIAGEN Validation Report

Developmental validation of GlobalFiler PCR amplification kit: a 6-dye multiplex assay designed for amplification of casework samples

AmpFlSTR COfiler PCR Amplification Kit

Technical Focus. Direct PCR Amplification of Buccal Samples on the NUCLEIC-CARD COLOR With the AmpFlSTR Identifiler Direct PCR Amplification Kit

Internal Validation of the Promega PowerPlex Fusion System with the Applied Biosystems 3130xl Genetic Analyzer

Forensic News. FAS Corner April The Maximizing Data Quality Series Part 2: DNA Quantitation

PowerPlex Fusion 6C System

Virginia and the New SWGDAM Guidelines

QIAGEN Whole Genome Amplification REPLI-g Eliminating Sample Limitations, Potential Use for Reference Material

Investigation of the effects of sample degradation and inhibition in forensic DNA typing

Comparison of the Promega Power Y and AB AmpFlSTR YFiler kits and the Subsequent Validation of YFiler.

Generating Forensic DNA Profiles

STR Interpretation Guidelines

Maximizing the Performance of Capillary Electrophoresis Systems The Maximizing Data Quality Series Part 4

DNA Expert Witness. Nuclear DNA 10/23/14. Adams County Bar Association. DNA found in the nucleus of the cell is called nuclear DNA.

The injection of the 28 and 29 PCR cycle data was performed at 3kV for 10 and 5 seconds.

AmpFlSTR COfiler. PCR Amplification Kit. User Bulletin

Characters of degraded DNA

AmpFlSTR Identifiler Plus

DNA Mixture Interpretation Workshop Karin Crenshaw. Reporting DNA Mixture Results and Statistics

AutoMate Express Forensic DNA Extraction System

Get more information from challenging samples with next-generation sequencing of short tandem repeats

Introducing the Applied Biosystems TM Precision ID NGS System for Human Identification

Authenticating human cell lines using the Identifiler kits and capillary electrophoresis platforms

PowerPlex. Y System Validation

Implementation of MPS into a Specialist Casework Laboratory. David Ballard

Procedure for GeneMapper ID-X for Casework

Notice of Amendment of the FBI s STR Population Data Published in 1999 and 2001

Routine Use of ForenSeq Solution on Casework Samples: Feedback One Year After Lab Implementation

Enhanced Resolution and Statistical Power Through SNP Distributions Within the Short Tandem Repeats

Training on STR Typing Using Commercial Kits and ABI 310/3100

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Validation of the AmpF STR R MiniFiler TM PCR Amplification Kit for Use in Forensic Casework*

TECHNICAL NOTE. JForensicSci,Nov. 2004, Vol. 49, No. 6 Paper ID JFS Available online at:

Y chromosomal STRs in forensics

Mutations during meiosis and germ line division lead to genetic variation between individuals

Procedure for GeneMapper ID-X for Casework

Overview of the Ibis STR Assay

FORENSIC GENETICS. DNA in the cell FORENSIC GENETICS PERSONAL IDENTIFICATION KINSHIP ANALYSIS FORENSIC GENETICS. Sources of biological evidence

DNA 101. DNA 101:Kate Philpott and Jennifer Friedman

Capillary Electrophoresis in DNA Analysis

Understanding PCR. Total allelic product Peak height Back stutter Forward stutter Variability in peak height

Validation of a Multiplexed System for Quantification of Human DNA and Human Male DNA and Detection of PCR Inhibitors in Biological Samples

Naming Convention and Laboratory Methods: PROVEDIt Database

Puritan Report for Batch PC Lot# 3127, Blue Pink and Yellow. Swabs were received for testing on May 22, 2012

The Evolution of Short Tandem Repeat (STR) Multiplex Systems

AmpFlSTR NGM PCR Amplification Kit

Evaluation of the Autogen FlexSTAR automated DNA extractor, for suitability in routine diagnostic use

Human Identification Solutions Conference, Mar , Madrid Quantifiler Trio kit and forensic samples management: a matter of degradation

Automated purification of DNA from bones of a Bronze Age family using the BioRobot EZ1 workstation

!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"

A*01:02, 68:02 B*15:10, 58:02 DRB1*03:01, 12:01

Automated Extraction of High Quality Genomic DNA from Forensic Evidence Samples Using a Cartridge-Based System

GenPlex HID Training Class I

Short Tandem Repeat (STR) Analysis

TWGDAM Validation of AmpF STR PCR Amplification Kits for Forensic DNA Casework

Biology/DNA DNA Interpretation SOP. Biology/DNA Division

PowerPlex ESX 17 Fast System for Use on the Applied Biosystems Genetic Analyzers

The STAR Q Swab AS Instrument for highthroughput PCR setup of QIAGEN s Investigator STR GO! Kits

AmpFlSTR NGM SElect PCR Amplification Kit. User Guide

A Rape on a Minor Victim Under POCSO Act 2012 Investigation Through DNA Analysis Technique A Case Study

Uniparental disomy (UPD) analysis of chromosome 15

PowerPlex Y23 Developmental Validation

Transcription:

AmpF STR NGM PCR Amplification Kit - Overview

The most advanced STR kits optimized for analysis of forensic casework and database samples in Europe Data Quality Worth Sharing! 9/7/2011 Life Technologies 2

The AmpFlSTR NGM Kit: Performance Enhanced! Greater power of discrimination Amplifies the 12 loci in the European Standard Set plus D2S1338, D19S433, D16S539 & Amelogenin Exceptional profile quality Implementation of the latest improvements in primer synthesis and purification procedures to produce an artifact-free baseline Increased sensitivity Improved buffer formulation increases amplification efficiency and maximises signal, even for the minor contributor in mixed samples Ability to amplify and analyze challenging samples without increasing cycle number or changing reaction conditions Option of a 30 cycle protocol for greater flexibility Maximum success with compromised samples Improved buffer formulation overcomes significant levels of inhibition and supports enhanced profile and locus balance, even when inhibitors are present Concentration of loci in the low molecular weight region of the profile increases the power of discrimination in partial profiles Works in conjunction with the MiniFiler Kit to recover the maximum number of ESS loci when amplifying highly degraded samples 9/7/2011 Life Technologies 3

The AmpFlSTR NGM Kit: Quality Maintained! Maximized concordance with previously typed samples Maintains all STR primer sequences for loci common to the SGM Plus, Identifiler & SEfiler Plus kits > Contains the additional primer for D8S1179 included in all AmpFlSTR kits since the Identifiler kit Optimal detection Uses the same highly optimized dye set as the Identifiler & SEfiler Plus Kits Familiar workflow Uses the same reaction volume and instrument workflow as the Identifiler & SEfiler Plus Kits Requirement for only a single kit & a single amplification protocol for both casework and database samples Optimal locus spacing Use of proprietary and proven mobility modifier technology to maximize locus spacing 9/7/2011 Life Technologies 4

NGM Kit Configuration: Building Blocks for Success Size Standard GeneScan 500 LIZ or GeneScan 600 LIZ v2.0 Components Master mix Primer set Control DNA 007 Allelic ladder Reaction Conditions 25µL Reaction Volume 1 ng Input DNA 29/30 Cycle Amplification Reduced Cycling Time Instruments 9700 or Veriti PCR Systems, 310, 3100, 3130 & 3500 Series Analyzers Dye Set G5 Dye Set, 5 Dye Chemistry 9/7/2011 Life Technologies 5

AmpFlSTR NGM PCR Amplification Kit Locus Configuration 200bp D10S1248 VWA D16S539 D2S1338 Amel D8S1179 D21S11 D18S51 D22S1045 D19S433 TH01 FGA D2S441 D3S1358 D1S1656 D12S391 10 PEGs 8 PEGs 8 PEGs 8 PEGs 10 PEGs Amplicon Size Ranges (bp) 10 PEGs 50 100 150 200 250 300 350 400 Use of mobility modifiers permits optimal spacing of loci 9/7/2011 Life Technologies 6

AmpFlSTR NGM PCR Amplification Kit Allelic Ladder 9/7/2011 Life Technologies 7

AmpFlSTR NGM PCR Amplification Kit 1ng Control DNA 007 9/7/2011 Life Technologies 8

AmpFlSTR Kit Configurations Comparison of Pi Values Kit Configuration Hispanic African American US Caucasian SGM Plus Kit Not Available 7.9 x 10-14 2.99 x 10-13 SEfiler Plus Kit Not Available 6.47 x 10-15 7.46 x 10-14 Identifiler Kit 7.65 x 10-18 1.31 x 10-18 5.01 x 10-18 MiniFiler Kit 1.05 x 10-10 6.52 x 10-11 8.21 x 10-11 Identifiler Kit < 200bp (+TPOX) 7.32x 10-08 2.01x 10-08 6.10x 10-08 NGM Kit 1.60 x 10-19 4.61 x 10-20 2.21 x 10-19 NGM Kit < 200 bp (+D21S11) 3.31-12 8.75 x 10-13 2.64 x 10-12 9/7/2011 Life Technologies 9

AmpFlSTR NGM PCR Amplification Kit Population Study Genotype Concordance AmpFlSTR Kit Comparison Number of Individuals Number of Loci Number of Alleles Concordance NGM Kit v Profiler Plus Kit 1231 6 14772 100% NGM Kit v SGM Plus Kit 1231 11 27082 100% NGM Kit v Identifiler Kit 1231 11 27082 100% NGM Kit v NGM SElect Kit 1231 16 39392 100% The NGM Kit contains an additional reverse primer at the D8S1179 locus to accommodate a rare mutation identified in Chamorro and Filipino populations from Guam. This primer was developed for inclusion in the Identifiler kit and is included as standard in all subsequent AmpFlSTR kits containing D8S1179. This primer is not found in the SGM Plus kit 9/7/2011 Life Technologies 10

AmpFlSTR Kit Primer Strategy AmpFlSTR Kit primer sequences and primer complements are maintained wherever possible to enable maximum concordance between data generated with different AmpFlSTR kits Consistent genotypes between historical and contemporary data sets Consistent genotypes between database and the majority of casework samples Simplified analysis, interpretation and reporting of genotype results Changes are made to AmpFlSTR Kit primer sequences or primer complements only when the result is of significant benefit to the analysis of forensic samples Reduction of amplicon size in the MiniFiler kit for the analysis of degraded samples > Only those markers demonstrated to perform poorly in degraded samples are re-engineered to minimise the number of alternate primer sequences in use in the laboratory Improvement of genotyping accuracy for known mutations by the inclusion of degenerate primers > Potential for a homozygote to heterozygote change at the affected locus only 9/7/2011 Life Technologies 11

Promoting Performance and Concordance NGM Kit Primer Information: D8S1179 Rare mutation identified during development of the Identifiler Kit Introduced into all subsequent AmpFlSTR Kits to address this mutation Cause: A single G-A transition in the primer binding region for the standard AmpFlSTR reverse D8S1179 primer Kits containing the primer will yield heterozygote genotypes for samples containing the mutation 9/7/2011 Life Technologies 12

Promoting Performance and Concordance NGM Kit Primer Information: Amelogenin Identifiler Kit NGM Kit Equine Bovine Canine Amelogenin primer sequences redesigned from previous AmpFlSTR Kits to reduce cross species reactivity significantly Ovine 9/7/2011 Life Technologies 13

Promoting Performance and Concordance NGM Kit Primer Information: Amelogenin, D2S441, D22S1045 Kit updated in 2011 to include three SNP-specific primers to address mutations at the Amelogenin, D2S441 and D22S1045 loci X allele drop-out 15 allele drop-out 9.1 allele drop-out Amelogenin D22S1045 D2S441 Amelogenin mutation identified as a result of the redesign of the primers to improve cross-species reactivity, D2S441 and D22S1045 mutations reported by NIST Mutation Frequency Amelogenin: Frequency ~0.9% of Caucasian genomes D2S441: Frequency ~5.1% of Korean genomes D22S1045: Frequency ~1.4% of African American genomes 9/7/2011 Life Technologies 14

AmpFlSTR Kit Primer Set Comparison Locus AmpFlSTR Kit Identifiler Kit SEfiler Plus Kit NGM Kit NGM SElect Kit Amelogenin vwa D16S539 D2S1338 D3S1358 SGM Plus Kit Primers New F/R Primers to Improve Specificity (includes 1 x SNP-Specific Primer) D21S11 D18S51 D19S433 TH01 FGA D8S1179 SGM Plus Kit Primers SGM Plus Kit Primers + 1 x SNP-Specific Primer SE33 N/A Published F/R Primers N/A 1 x SEfiler Plus Primer + 1 x New Primer D10S1248 D1S1656 D21S391 N/A D22S1045 D2S441 9/7/2011 Life Technologies 15 New Loci: Identical Primers New Loci: Identical Primers (includes 1 x SNP-Specific Primer per Locus)

Developmental Validation of the AmpFlSTR NGM PCR Amplification Kit Based on SWGDAM guidelines for manufacturers Studies included (among others) Sensitivity Reproducibility > Heterozygote Peak Height Ratio, Intra-color Balance PCR inhibition DNA degradation Selection of Guard Band > Effect of Cycle Number, Annealing Temperature etc. Reproducible Artifacts Mixtures and Species Specificity Instrument concordance (310 NT, 3100 and 3130 Systems) > Validated for use with the 3500 Series Genetic Analyzers during instrument validation 9/7/2011 Life Technologies 16

Greater Sensitivity 1 ng 500 pg 250 pg 125 pg 62.5 pg 32.25 pg 9/7/2011 Life Technologies 17

Increased Allele Recovery at Lower Input DNA Levels 9/7/2011 Life Technologies 18

Peak Height Ratio Maintained at Decreasing Input DNA Concentrations 3.0 2.5 Heterozygote Peak Height Ratio 2.0 1.5 1.0 0.5 1 ng 500 pg 250 pg 125 pg 0.0 NGM SGM SEF IDE NGM SGM SEF IDE NGM SGM SEF IDE NGM SGM SEF IDE Amplification Kit 9/7/2011 Life Technologies 19

Improved Performance in the Presence of Inhibitors Replicates SGM Plus Kit SEfiler Plus Kit Loci No Inhibitor Humic Acid 40 ng/µl 80 ng/µl Hematin 100 µm 200 µm Identifiler Kit NGM Kit Green = Full Profile, Red = Allelic Dropout 9/7/2011 Life Technologies 20

Improved Performance on Degraded Samples 0 U DNase I 3 U DNase I 4 U DNase I 5 U DNase I 6 U DNase I The longer loci which fail due to extreme degradation may be recovered using the MiniFiler Kit 6 U DNase I 9/7/2011 Life Technologies 21 MiniFiler Kit

The Importance of Mobility Modifiers: Amplicon Mobility v Amplicon Size for the NGM Kit Amplicon Mobility Amplicon Size D2S1338 D2S1338 D16S539 D16S539 vwa vwa D10S1248 D10S1248 D18S51 D18S51 D21S11 D21S11 D8S1179 D8S1179 Locus AMEL FGA TH01 D19S433 D22S1045 D12S391 D1S1656 D3S1358 Locus AMEL FGA TH01 D19S433 D22S1045 D12S391 D1S1656 D3S1358 * * * * * * D2S441 D2S441 50.00 100.00 150.00 200.00 250.00 300.00 350.00 400.00 50.00 100.00 150.00 200.00 250.00 300.00 350.00 400.00 Amplicon Mobility (bp) Amplicon Size (bp) Amplicons can be engineered as short as possible while increasing the run size on the CE platform to ensure optimal locus spacing 9/7/2011 Life Technologies 22

The Importance of Mobility Modifiers: Amplicon Mobility v Amplicon Size for the MiniFiler Kit Amplicon Mobility Amplicon Size D7S820 D7S820 D13S317 D13S317 D21S11 D2S1338 D21S11 D2S1338-183 bp -33 bp Locus Amel Locus Amel D18S51 D16S539 D18S51 D16S539-157 bp -168 bp FGA FGA -87 bp CSF1PO CSF1PO 50.00 100.00 150.00 200.00 250.00 300.00 Amplicon Mobility (bp) 50.00 100.00 150.00 200.00 250.00 300.00 Amplicon Size (bp) Together, the NGM & MiniFiler Kits provide an unparalleled solution for the amplification of highly degraded samples 9/7/2011 Life Technologies 23

A Powerful Solution for Degraded Samples: The NGM & MiniFiler Kits 200 bp Physical amplicon size ranges when using the NGM /MiniFiler Kit Combination 9/7/2011 Life Technologies 24

Maximum Profile Quality: Baseline Comparisons Between the NGM, SGM Plus & Identifiler Kits NGM Kit SGM Plus Kit Identifiler Kit 9/7/2011 Life Technologies 25

Maximum Profile Quality: Mixture Interpretation Major Component: 775 pg; Minor Component 125 pg Full profile obtained for the minor contributor 9/7/2011 Life Technologies 26

Performance on Casework Samples All Data Courtesy of Forensic Laboratories 9/7/2011 Life Technologies 27

Bone sample amplified using the Identifiler Kit Extraction: Qiagen QIAamp DNA MiniKit; DNA Input Concentration: Not Detected; Cycle Number = 28 Data Courtesy of RIS Carabinieri Roma, Italy 9/7/2011 Life Technologies 28

Bone sample amplified using the NGM Kit Extraction: Qiagen QIAamp DNA MiniKit; DNA Input Concentration: Not Detected; Cycle Number = 29 Data Courtesy of RIS Carabinieri Roma, Italy 9/7/2011 Life Technologies 29

Swab from a cap headband amplified using the SGM Plus Kit Extraction: Chelex; DNA Input Concentration: 0.02 ng; Cycle Number = 28 Data Courtesy of National Bureau of Investigation, Forensic Laboratory, Finland 9/7/2011 Life Technologies 30

Swab from a cap headband amplified using the NGM Kit Extraction: Chelex; DNA Input Concentration: 0.02 ng; Cycle Number = 29 Data Courtesy of National Bureau of Investigation, Forensic Laboratory, Finland 9/7/2011 Life Technologies 31

Swab from a window handle amplified using the SGM Plus Kit Extraction: Organic; DNA Input Concentration: Not Detected; Cycle Number = 28 Data Courtesy of Eesti Kohtuekspertiisi Instituut, Tallinn, Estonia 9/7/2011 Life Technologies 32

Swab from a window handle amplified using the NGM Kit Extraction: Organic; DNA Input Concentration: Not Detected; Cycle Number = 29 Data Courtesy of Eesti Kohtuekspertiisi Instituut, Tallinn, Estonia 9/7/2011 Life Technologies 33

Swab from a car dashboard amplified using the SEfiler Plus Kit Extraction: Qiagen QIAamp DNA Mini kit; DNA Input Concentration: Not Known; Cycle Number = 30 Data Courtesy of a German State Police Laboratory 9/7/2011 Life Technologies 34

Swab from a car dashboard amplified using the NGM Kit Extraction: Qiagen QIAamp DNA Mini kit; DNA Input Concentration: Not Known; Cycle Number = 29 Data Courtesy of a German State Police Laboratory 9/7/2011 Life Technologies 35

Sample from a fired bullet head amplified with the Identifiler Kit Extraction: Nucleospin Columns; DNA Input Concentration: 0.11 ng; Cycle Number = 28 Data Courtesy of IGNA, France 9/7/2011 Life Technologies 36

Sample from a fired bullet head amplified with the NGM Kit Extraction: Nucleospin Colums; DNA Input Concentration: 0.11 ng; Cycle Number = 29 Data Courtesy of IGNA, France 9/7/2011 Life Technologies 37

AmpFlSTR NGM PCR Amplification Kit Impact on Laboratory Workflow More information per sample Amplifies the 12 loci in the European Standard Set plus D2S1338, D19S433 and D16S539 Facilitates international comparability of profiles Maximum reliability of results Proven Applied Biosystems product and data quality ISO 13485 manufacturing, rigorous quality control testing Validated according to DAB and SWGDAM guidelines Optimized as part of an instrument-reagent-software system Professional training and support Reduced labor and decreased time to result Single amplification protocol for both casework and database samples Increased first-pass success rate for difficult casework samples Reduced time needed for data analysis due to production of highest quality profiles Maximised concordance with data generated with previous AmpFlSTR kits 9/7/2011 Life Technologies 38

Thank You 2011 Life Technologies Corporation. All rights reserved. The trademarks mentioned herein are the property of Life Technologies Corporation or their respective owners For Research, Forensic or Paternity Use Only. Not intended for any animal or human therapeutic or diagnostic use 9/7/2011 Life Technologies 39