ProSimPlus Library (Standard version + rate base option)

Similar documents
Exercise 5. Simulation of HDA plant in UniSim

SIMPACK - MODEL DEVELOPMENT PACKAGE FOR POWER PLANTS

Exercise 5. Simulation of HDA plant in UniSim

HYSYS WORKBOOK By: Eng. Ahmed Deyab Fares.

Utilization of THERMOPTIM Optimization Method

Problems in chapter 9 CB Thermodynamics

- 2 - SME Q1. (a) Briefly explain how the following methods used in a gas-turbine power plant increase the thermal efficiency:

CHAPTER 1 BASIC CONCEPTS

Improvement of distillation column efficiency by integration with organic Rankine power generation cycle. Introduction

Optimal Design Technologies for Integration of Combined Cycle Gas Turbine Power Plant with CO 2 Capture

ME ENGINEERING THERMODYNAMICS UNIT III QUESTION BANK SVCET

Simple Dew Point Control HYSYS v8.6

Fluid Mechanics, Heat Transfer, and Thermodynamics Design Project. Production of Acrylic Acid

Example SPC-2: Effect of Increasing Column P on a C3 splitter

Chapter 5: Thermodynamic Processes and Cycles

Engineering Thermodynamics

CHAPTER 3 MODELLING AND SIMULATION

Chapter 1 STEAM CYCLES

Fluid Mechanics, Heat Transfer, and Thermodynamics Fall Design Project. Production of Dimethyl Ether

Lecture No.1. Vapour Power Cycles

Fluid Mechanics, Heat Transfer, Thermodynamics Design Project. Production of Allyl Chloride

Methanol Production by Gasification of Heavy Residues

PINCH ANALYSIS: For the Efficient Use of Energy, Water & Hydrogen. PULP AND PAPER INDUSTRY Energy Recovery and Effluent Cooling at a TMP Plant

Chapter 8. Vapor Power Systems

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

GAS CONDITIONING & PROCESSING TRAINING

Faculty of Engineering 2 nd year 2016 Mechanical Engineering Dep. Final-exam (code: M 1222)

Thermodynamic analysis on post combustion CO 2 capture of natural gas fired power plant

Module 2: Solid Fossil Fuel (Coal) Lecture 12: Combustion of coal and coke making

Modeling Techniques for Increased Accuracy

NEW RECYCLE PROCESS SCHEME FOR HIGH ETHANE RECOVERY NEW PROCESS SCHEME FOR HIGH NGL RECOVERY INTRODUCTION. Abstract PROCESS FUNDAMENTALS

PINCH ANALYSIS: For the Efficient Use of Energy, Water & Hydrogen. PULP AND PAPER INDUSTRY Energy Recovery and Effluent Cooling at a TMP Plant

Simple Dew Point Control HYSYS v10. When the simulation is set up the overall PFD should look like the following figure.

S.E. (Mechanical) (First Semester) EXAMINATION, 2012 APPLIED THERMODYNAMICS (2008 PATTERN) Time : Three Hours Maximum Marks : 100

Thermodynamics: An Engineering Approach, 6 th Edition Yunus A. Cengel, Michael A. Boles McGraw-Hill, 2008

SUMMER 13 EXAMINATION

AREN 2110: Thermodynamics Spring 2010 Homework 7: Due Friday, March 12, 6 PM

Multi-Variable Optimisation Of Wet Vapour Organic Rankine Cycles With Twin-Screw Expanders

Design Features of Combined Cycle Systems

GATE Solution 2000 to 2015 GATE SOLUTION to Detailed solution of each question CHEMICAL ENGINEERING GATE SOLUTION

R13. II B. Tech I Semester Regular/Supplementary Examinations, Oct/Nov THERMODYNAMICS (Com. to ME, AE, AME) Time: 3 hours Max.

Modeling, Simulation and Optimization of Energy Systems using Aspen Plus. Giovanni Manente University of Padova

a. The power required to drive the compressor; b. The inlet and output pipe cross-sectional area. [Ans: kw, m 2 ] [3.34, R. K.

Effluent Treatment Using Evaporation and Crystallisation Technology

Chapter 10 VAPOR AND COMBINED POWER CYCLES

Quiz Questions. For Process Integration. Fill in the blanks type Questions

Enhancement of CO2 Refrigeration Cycle Using an Ejector: 1D Analysis

Aspen Plus. Unit Operation Models. Version STEADY STATE SIMULATION. AspenTech

Design Project Energy Balances and Numerical Methods Styrene Manufacture

Second Law of Thermodynamics

SYNTHESIS AND OPTIMIZATION OF DEMETHANIZER FLOWSHEETS FOR LOW TEMPERATURE SEPARATION PROCESSES

Attachment 18. Undergraduate Teaching Laboratory Facilities

OPTIMIZATION OF PARAMETERS FOR HEAT RECOVERY STEAM GENERATOR (HRSG) IN COMBINED CYCLE PLANTS

CHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

Chapter 1 Basic Concepts

Fluid Mechanics, Heat Transfer, and Thermodynamics. Design Project. Production of Acetone

Chapter 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

Permanent City Research Online URL:

Contents. Tribute to a great thermodynamicist Professor Lucien Borel

Supercritical Fluids

Commercial-Scale Performance Predictions for High-Temperature Electrolysis Plants Coupled to Three Advanced Reactor Types

Enthalpy Calculations. Change in enthalpy can occur because of change in temperature, change in phase, or mixing of solutions and reactions.

OUTCOME 2 TUTORIAL 2 STEADY FLOW PLANT

Chapter 10 POWER CYCLES. Department of Mechanical Engineering

LECTURE-14. Air Refrigeration Cycles. Coefficient of Performance of a Refrigerator:

Distillation DEPARTMENT OF CHEMICAL ENGINEERING

Table of Contents. iii. vi Tables. Figures. viii Foreword. ix Acknowledgments

Chapter 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

Fluid Mechanics, Heat Transfer, and Thermodynamics Fall Design Project. Production of Drying Oil

A comparison of advanced thermal cycles suitable for upgrading existing power plant

Vapor and Combined Power Cycles

Appendix B. Glossary of Steam Turbine Terms

Revue des Energies Renouvelables Spécial ICT3-MENA Bou Ismail (2015) Numerical study of a single effect ejector-absorption cooling system

CHAPTER 2 STUDY OF 210 MW BOILER SYSTEM 2.1 DESCRIPTION OF 210 MW BOILER

Reforming Natural Gas for CO 2 pre-combustion capture in Combined Cycle power plant

Superior Efficiency Reduced Costs Viable Alternative Energy Kalex Kalina Cycle Power Systems For Cement Kiln Waste Heat Applications

Large scale hydrogen liquefaction in combination with LNG re-gasification

Enhancement of LNG Propane Cycle through Waste Heat Powered Absorption Cooling

Fluid Mechanics, Heat Transfer, Thermodynamics Design Project. Production of Styrene

Systematic Analysis of Proton Electrolyte Membrane Fuel Cell Systems Integrated with Biogas Reforming Process

Innovative Stripper Configurations to Reduce the Energy Cost of CO 2 Capture

Fluid Mechanics, Heat Transfer, Thermodynamics. Design Project. Production of Ammonia

Problems at the Cumene Production Facility, Unit 800

Available online at ScienceDirect. Energy Procedia 63 (2014 ) GHGT-12

UNIVERSITY OF TORONTO FACULTY OF APPLIED SCIENCE AND ENGINEERING FINAL EXAMINATION, DECEMBER 2008 MIE 411H1 F - THERMAL ENERGY CONVERSION

NATURAL GAS HYDRATES & DEHYDRATION

Exergy in Processes. Flows and Destruction of Exergy

Investigation of Separator Parameters in Kalina Cycle Systems

Energy and Exergy Analysis of a Simple Gas Turbine Cycle with Wet Compression

Kalex Kalina Cycle Power Systems For Use as a Bottoming Cycle for Combined Cycle Applications

HW-1: Due Tuesday 13 Jun 2017 by 2:00:00 pm EDT to Your Division s GradeScope Site

Training Venue and Dates REF Gas Dehydration & Booster Station Utilities Nov $5,750 PE038

Combined Heat and Power

Fluid Mechanics, Heat Transfer, Fluid Mechanics Design Project. Production of Ethanol

Evaluating Performance of Steam Turbine using CFD

CHAPTER 1 BASIC CONCEPTS THEORY

R13 SET - 1 '' ''' '' ' '''' Code No: RT31035

Introduction to Aerospace Propulsion. Prof. Bhaskar Roy. Prof. A. M. Pradeep. Department of Aerospace Engineering

DETERMINING THE MAXIMUM LNG PRODUCTION RATE BY PROCESS SIMULATION MODELLING OF LOW TEMPERATURE NATURAL GAS SEPARATION UNIT

Guidance page for practical work 15: modeling of the secondary circuit of a PWR

Transcription:

ProSimPlus Library (Standard version + rate base option) Contents UNIT OPERATIONS... 5 Absorber... 5 Absorber with reboiler... 5 Rigorous two-phase distillation (L-V) with partial condenser and decanter... 6 Rigorous two-phase distillation (L-V) with total condenser... 6 Rigorous two-phase distillation (L-V) with total condenser and decanter... 7 Column sizing... 7 Distillation "short-cut"... 8 Stripper with total condenser... 9 Stripper with total condenser and decanter... 9 Stripper with partial condenser... 10 Stripper with partial condenser and decanter... 10 Rigorous three-phase distillation (L-L-V) with partial condenser, without decanter... 11 Rigorous three-phase distillation (L-L-V) with partial condenser and decanter... 12 Rigorous three-phase distillation (L-L-V) with total condenser, without decanter... 13 Rigorous three-phase distillation (L-L-V) with total condenser and decanter... 14 Liquid-liquid extraction... 14 Liquid-liquid extraction with reflux... 15 Decanter... 15 Generalized three-phase flash (liquid-liquid-vapor)... 15 Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 1 / 4

Generalized two-phase flash (liquid-vapor)... 16 Reactive two-phase flash... 16 Simple heat exchanger... 16 Cooler/Heater... 16 Heat exchanger... 17 Double pipe heat exchanger... 17 Multi-fluid heat exchanger... 18 Brazed plate fin heat exchanger... 18 MHX exchanger... 18 Continuous stirred tank reactor... 18 Equilibrium reactor... 19 Simple chemical reactor... 19 Plug flow reactor... 19 Solid oxide fuel cell (SOFC)... 19 Combustion... 20 Methanization reactor... 20 Pump... 20 Compressor... 20 Generalized compressor... 21 Expander... 21 Pressure drop calculations... 21 Vapor ejector... 21 Expansion valve... 22 Orifice plate... 22 Mixer... 22 Stream splitter... 22 Component splitter... 22 Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 2 / 4

Belt filter... 23 Filter press... 23 Clarifying filter... 23 Hydrocyclone... 23 Tank (solid-liquid separation)... 24 Liquid-solid crystallizer... 24 Evaporator-crystallizer... 24 Heat pump... 25 Generalized heat pump... 25 Organic rankine cycle... 26 Fuel engine... 26 Fuel turbine... 27 Boiler... 27 ENERGY EFFICIENCY... 28 Pinch analysis... 28 Exergy balance... 28 ECONOMIC EVALUATION... 29 Economic evaluation (COST)... 29 OPTIMIZATION AND DESIGN SPECIFICATIONS... 30 Constraints and recycles... 30 Information stream handler... 30 Measurement... 31 ph meter... 31 Solid solubility measurement... 31 Optimization... 32 UTILITIES AND TOOLS... 33 HCurves... 33 Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 3 / 4

Calculator switch... 33 USER DEFINED UNIT OPERATIONS... 34 Windows scripts... 34 CAPE-OPEN unit operation... 34 User defined unit operation (UTI)... 34 RATE BASE OPTION... 35 Absorber by rate-based model (optional)... 35 Absorber with reboiler by rate-based model (optional)... 35 Distillation with partial condenser by rate-based model (optional)... 36 Distillation with total condenser by rate-based model (optional)... 36 Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 4 / 4

UNIT OPERATIONS Unit operation Short description Module on the flowsheet Absorber Makes it possible to represent a multi-stage liquid-vapor separation process where takes place a counter-current mass transfer between a liquid phase and a vapor phase within a column without boiler nor condenser. A liquid feed, a vapor sidestream at the column overhead, a vapor feed and a liquid sidestream in bottom of column are necessary. Sidestreams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage, nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Absorber Absorber with reboiler Makes it possible to represent a multi-stage liquid-vapor separation process where takes place a counter-current mass transfer between a liquid phase and a vapor phase within a column with a boiler but without condenser. A liquid feed, a vapor sidestream at the column overhead and a liquid sidestream in bottom of column are necessary. Sidestreams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage, nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Absorber with a reboiler Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 5 / 5

Rigorous two-phase distillation (L-V) with partial condenser and decanter Makes it possible to represent a multi-stage liquid-vapor separation process where takes place a counter-current mass transfer between a liquid phase and a vapor phase within a column with a boiler, a partial condenser, and a top decanter. A feed and at least a vapor distillate and a liquid bottom product are required. Side streams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage; nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Two-phase distillation with partial condenser and decanter Rigorous two-phase distillation (L-V) with total condenser Makes it possible to represent a multi-stage liquid-vapor separation process where takes place a counter-current mass transfer between a liquid phase and a vapor phase within a column with a boiler and a total condenser. A feed and at least a liquid distillate and a liquid bottom product are required. Side streams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage, nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Two-phase distillation with total condenser Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 6 / 6

Rigorous two-phase distillation (L-V) with total condenser and decanter Makes it possible to represent a multi-stage liquid-vapor separation process where takes place a counter-current mass transfer between a liquid phase and a vapor phase within a column with a boiler, a total condenser and a top decanter. A feed and at least a liquid distillate and a liquid bottom product are required. Side streams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage, nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Two-phase distillation with total condenser and decanter Column sizing The COLUMN SIZING unit block is used to carry out or to check the sizing of a column, without having carried out preliminary rigorous calculation. No fluid phase equilibrium or enthalpy calculation is carried out inside this unit operation, input streams being considered equal to outlet streams. Nevertheless, transport properties (density, viscosity and area tension...) can either be calculated from the input streams characteristics or provided by the user. These properties being known, the column sizing unit operation enables to check existing columns hydraulic operation or to size a column according to various criteria. Column sizing Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 7 / 7

Distillation "short-cut" Makes it possible to design a simple distillation column with one feed and two products, the distillate and the bottom product. When the separation fractions of two key components at the distillate and at the bottom product are specified, the unit operation provides: the reflux ratio, the number of theoretical stages, the position of the feed stage, the distillate and bottom product compositions, the reboiler heat duty, the heat to be removed at the condenser. This unit operation can be used for the approximate design of a distillation column. The standard methods used in this unit operation are: Fenske, Underwood, Gilliland and Kirkbride. Distillation «short-cut» Divided wall column shortcut Makes it possible to a size a distillation column with a separation wall, with a feed and three products: the distillate, the waste, and the intermediate sidestream. Specifying the recovery rate of the three key-compounds for each outlet stream and some operating constraints allows the unit operation to calculate a sizing by theoretical stages, and initializations for the intermediate streams required for a rigorous calculation. The pre-sizing method adapted is based on the combination of several shortcuts for these classical pre-sizing methods: Fenske, Underwood, Gilliland and Kirkbride. Divided wall column short-cut Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 8 / 8

Stripper with total condenser Makes it possible to represent a multi-stage liquid-vapor separation process where takes place a counter-current mass transfer between a liquid phase and a vapor phase within a column having a total condenser but without boiler. A column bottom vapor feed and at least a liquid distillate and a column bottom liquid sidestream are required. Sidestreams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage, nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Stripper with total condenser Stripper with total condenser and decanter Makes it possible to represent a multi-stage liquid-vapor separation process where takes place a counter-current mass transfer between a liquid phase and a vapor phase within a column having a total condenser and a decanter but without boiler. A column bottom vapor feed and at least a liquid distillate and a column bottom liquid sidestream are required. Sidestreams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage, nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Stripper with total condenser and decanter Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 9 / 9

Stripper with partial condenser Makes it possible to represent a multi-stage liquid-vapor separation process where takes place a counter-current mass transfer between a liquid phase and a vapor phase within a column having a partial condenser but without boiler. A column bottom vapor feed and at least a vapor distillate and a column bottom liquid sidestream are required. Sidestreams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage; nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Stripper with partial condenser Stripper with partial condenser and decanter Makes it possible to represent a multi-stage liquid-vapor separation process where takes place a counter-current mass transfer between a liquid phase and a vapor phase within a column having a partial condenser and a decanter but without boiler. A column bottom vapor feed and at least a vapor distillate and a column bottom liquid sidestream are required. Sidestreams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage, nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Stripper with partial condenser and decanter Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 10 / 10

Rigorous three-phase distillation (L-L-V) with partial condenser, without decanter Makes it possible to represent a multi-stage liquid-liquid-vapor separation process where takes place a counter-current mass transfer between one or two liquid phases and a vapor phase within a column with a boiler and a partial condenser, but without top decanter. Each stage of the column can be three-phase and phase stability tests are carried out in order to determine the locations of the two liquid phases coexistence. The distinction between heavy phase and light phase is carried out automatically by the program, by comparing the densities. A feed, a vapor distillate and a liquid bottom product are required. Heavy or light sidestreams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage, nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Three-phase distillation L-L-V Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 11 / 11

Rigorous three-phase distillation (L-L-V) with partial condenser and decanter Makes it possible to represent a multi-stage liquid-liquid-vapor separation process where takes place a counter-current mass transfer between one or two liquid phases and a vapor phase within a column with a boiler, a partial condenser, and a top decanter. Each stage of the column can be three-phase and phase stability tests are carried out in order to determine the locations of the two liquid phases coexistence. The distinction between heavy phase and light phase is carried out automatically by the program, by comparing the densities. A feed, a vapor distillate and a liquid bottom product are required. Heavy or light sidestreams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage, nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Three-phase distillation L-L-V with Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 12 / 12

Rigorous three-phase distillation (L-L-V) with total condenser, without decanter Makes it possible to represent a multi-stage liquid-liquid-vapor separation process where takes place a counter-current mass transfer between one or two liquid phases and a vapor phase within a column with a boiler and a total condenser, but without top decanter. Each stage of the column can be threephase and phase stability tests are carried out in order to determine the locations of the two liquid phases coexistence. The distinction between heavy phase and light phase is carried out automatically by the program, by comparing the densities. A feed, a liquid distillate and a liquid bottom product are required. Heavy or light sidestreams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage, nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Three-phase distillation L-L-V with total condenser Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 13 / 13

Rigorous three-phase distillation (L-L-V) with total condenser and decanter Makes it possible to represent a multi-stage liquid-liquid-vapor separation process where takes place a counter-current mass transfer between one or two liquid phases and a vapor phase within a column with a boiler, a total condenser and a top decanter. Each stage of the column can be three-phase and phase stability tests are carried out in order to determine the locations of the two liquid phases coexistence. The distinction between heavy phase and light phase is carried out automatically by the program, by comparing the densities. A feed, a liquid distillate and a liquid bottom product are required. Heavy or light sidestreams and/or intermediate liquid or vapor feeds as well as exchanged heat duties can be specified at each stage. The mathematical model is based on the concept of theoretical stage, nevertheless it is possible to introduce Murphree efficiencies. The column sizing or rating can be carried out for all kind of column internals as well as many types of plates (see column sizing). It is also possible to specify that the whole column, or part of it, corresponds to a zone in which occur chemical reactions. Three-phase distillation with total condenser and decanter Liquid-liquid extraction Makes it possible to represent a multi-stage liquid-liquid extraction process where takes place a counter-current mass transfer between two liquid phases. Two feed streams including solvent, an extract sidestream and a raffinate sidestream are required. A feed, an extract sidestream and a raffinate sidestream can also be specified at each stage. The mathematical model is based on the concept of theoretical stage. For liquid-liquid equilibrium calculations, splitting ratios between the raffinate and extract phases can be calculated by the selected thermodynamic model or provided by the user. Liquid-liquid extraction column Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 14 / 14

Liquid-liquid extraction with reflux Makes it possible to represent a multi-stage liquid-liquid extraction process where takes place a counter-current mass transfer between two liquid phases. In this case the first stage is replaced by a stage known as reflux stage. Its role is to represent a separation process that enables to regenerate solvent, from the extract resulting from the extraction process itself. Two feed streams including solvent, an extract sidestream, a raffinate sidestream and a recovered solvent stream are required. A feed, an extract sidestream and a raffinate sidestream can also be specified at each stage. The mathematical model is based on the concept of theoretical stage. For liquid-liquid equilibrium calculations, splitting ratios between the raffinate and extract phases can be calculated by the selected thermodynamic model or provided by the user. Liquid-liquid extraction column with reflux Decanter Used to represent a liquid-liquid separation supposed to be at constant temperature and pressure thermodynamic equilibrium. If a demixing is detected, at the outlet a stream corresponds to the "light" liquid and another one to the "heavy" liquid. It is possible to specify liquid-liquid splitting ratios, independently from the selected thermodynamic model. Decanter Generalized three-phase flash (liquid-liquid-vapor) Used to model a flash separation for which two liquid phases and a vapor phase are at thermodynamic equilibrium. Several kind of flashes are available such as constant temperature and pressure flash (isothermal), constant heat duty and pressure flash (adiabatic) or constant pressure and vapor fraction flash. This unit operation has three outlet streams corresponding to the vapor stream, the "light" liquid stream and the "heavy" liquid stream. Generalized three-phase flash (liquid-liquid-vapor) Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 15 / 15

Generalized two-phase flash (liquid-vapor) Used to represent a flash operation for which it is supposed that thermodynamic equilibrium is reached. This module simulates all kind of flashes such as constant temperature and pressure flash, constant pressure and heat duty flash, constant vapor fraction and temperature or pressure flash, constant pressure and entropy flash. Liquid-vapor separator Two phases flash with one outlet stream Reactive two-phase flash A flash operation that includes chemical reactions. The liquid phase is homogeneous (no liquid phase splitting) and the physical state on output is 2-phases (i.e. vapor-liquid). Thermodynamic equilibrium is assumed. Reactive two-phase flash Simple heat exchanger Calculates the physical state (temperature and vapor fraction) of a stream when a heat duty is supplied. It allows to simply simulate a heat exchanger to heat or cool a stream. Simple heat exchanger Cooler/Heater Allows adjusting a stream temperature without worrying about the exchanger geometry. This module makes it possible to simulate a heat exchanger and to calculate the heat duty required to reach a specified temperature. Cooler / heater Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 16 / 16

Heat exchanger Calculates the heat exchange between two streams in a counter-current or co-current heat exchanger. For a given specification, the unit operation determines the output streams characteristics and calculates the exchanged heat duty (if it is not given). Moreover, from the knowledge of the global heat transfer coefficients, the unit operation enables to calculate a heat exchange area with or without taking into account possible phase changes. For heat exchangers with several tubes side and/or shell side passes, efficiency compared to pure counter-current is calculated. Generalized heat exchanger Shell and tube heat exchanger Kettle reboiler Plate and frame heat exchanger Double pipe heat exchanger This unit operation is used to determine the heat duty exchanged and the outlet temperatures (tube side and annular space side) of a heat exchanger of double-tube type knowing its geometry and the inlet stream characteristics. The correlations used to determine the pressure drops and the heat transfer coefficients on the two sides (tube and annular space) can be chosen by the user in the list proposed in this module. The flow inside the double-pipe heat exchanger can be counter-current or cocurrent with the availability of condensation or evaporation on the two sides. Double-pipe heat exchanger Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 17 / 17

Multi-fluid heat exchanger Brazed plate fin heat exchanger Calculates the heat exchange between a main stream and several secondary streams. As the streams remain unchanged on the mass level, only an energy balance is carried out. From the knowledge of the input and outlet temperatures of secondary streams, the thermal characteristics of the main outlet stream and the heat duties are calculated. This module calculates the thermal performances and the pressure drops of a unit operation, or a battery of unit operations in parallel, of given geometry in which can circulate up to 10 fluids in co-current or counter current flow. For a given specification, the module determines the output streams characteristics, calculates the quantities of exchanged heat and the temperature and enthalpy internal profiles, assuming a wall temperature constant. The brazed plate-fin heat exchanger (BPFHE) technology is relatively complex and this module allows a detailed description of the geometry of the BPFHE as well as the flow topology. Multi-fluid heat exchanger Brazed plate fin heat exchanger MHX exchanger Allows calculation of mass and enthalpy balances on a multi-streams heat exchanger or on a heat exchangers network. Heat energy integration could be evaluated from cold and hot composite curves.two modes are available : 1. Checking of an existing heat exchanger 2. Heat exchanger calculation. Several options are available to meet different specifications on streams, pinch, duty, heat exchange coefficient MHX exchanger Continuous stirred tank reactor Makes it possible to represent the operation of a perfectly stirred reactor with continuous feed and side stream. The mixture inside the reactor can be monophasic or two-phase. It is possible to take into account controlled and/or complex and/or equilibrium chemical reactions. For the calculation of the temperature within the reactor, various possibilities are proposed: adiabatic, isothermal... Phase changes are taken into account. Continuous stirred tank reactor Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 18 / 18

Equilibrium reactor The EQUILIBRIUM REACTOR unit operation is used to represent a chemical equilibrium in gas phase, with a specified system pressure, and with the choice of the temperature (isothermal reactor) or of the heat duty (for example adiabatic reactor).the equilibrium is calculated either by using the method of the equilibrium constants or by minimizing Gibbs free energy of the system. With the equilibrium constants method, the user can define approach temperatures to the equilibrium by giving for each reaction temperature deviations compared to the system temperature. The equilibrium constants are then calculated at the corresponding approach temperatures and not at the system temperature. Equilibrium reactor Simple chemical reactor Used to represent a reactor that can be adiabatic, isothermal, at imposed outlet temperature or with heat duty supplied, in which several reactions are taken into account with a set of conversion rates or a set of selectivities. Simple reactor Reaction tank Plug flow reactor Solid oxide fuel cell (SOFC) Allows representing the operation in steady state of a tubular flow reactor in which the hydrodynamics corresponds to an "ideal plug" type flow. This unit operation makes it possible to take into account equilibrium chemical reactions or reactions with controlled or complex kinetics. Moreover, for the temperature profile inside the reactor calculation, various options are possible; in particular, it is possible to describe an external jacket in which circulates a co-current or counter-current service fluid. Calculates mass and heat balance on a pile of electrochemical cells. This module is used to represent the behavior of the core of a Solid Oxide Fuel Cell without internal reforming of methane. Plug flow reactor Solid oxide fuel cell Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 19 / 19

Combustion Allows the simulation of chemical exothermal redox reactions, referred to as combustion reactions, which produce heat. The combustion requires two reagents: the combustive that brings the oxygen (O2), essential for the reaction, and the fuel that brings the material being burnt. The combustion unit operation can deal with gaseous fuels, as well as with solid or liquid fuels. Combustion Methanization reactor Allows the simulation of the anaerobic digestion of biodegradable compounds. This microbial biological process occurs in wet conditions in the absence of oxygen. The aim is to transform a complex organic waste (treated mixture) into a biogas (mainly composed of methane and carbon dioxide) and into a digestate (composed of organic and inorganic substance non degradable under the conditions of the process). The volatile matter applies to the organic part of the treated mixture, i.e. the compounds likely to produce biogas. The treated mixture is made up of all the compounds entering the unit operation. Methanization reactor Pump Used to simulate a pump. The pump exhaust pressure can either be provided or calculated from the knowledge of the electric power it consumes. Two representation models of its operation are available: volumetric pump or isentropic pump. Isentropic or volumetric efficiency as well as mechanical efficiency can be provided. Centrifugal pump Linear pump Generalized pump Compressor Used to simulate a mono or multistage compressor with or without intermediate cooling. Isentropic or mechanical efficiency can be provided. At the level of possible intermediate exchangers, the user can specify the cooling temperatures. Compressor Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 20 / 20

Generalized compressor Used to simulate a mono or multistage isentropic or polytropic compressor, with or without intermediate cooling. It has all the functionalities of the simple compressor unit operation but this unit operation makes it possible to use the manufacturer's curves as data of simulation. Generalized compressor Rotary compressor Reciprocating compressor Expander Pressure drop calculations Used to simulate a mono-stage expander with possibility of condensation. Calculation is performed from the outlet pressure or the temperature of dew point (or bubble point) pressure corresponding to the dew point (or bubble point) pressure expected on exit (this pressure will then be calculated by the module). Enables to calculate pressure drops sustained by a fluid during different transports (isothermal, adiabatic or including thermal exchanges) in a pipe with linear segments (tubular pipe) and/or fittings (valve, elbow...) and/or swages (enlarger or reducer).. The unit operation also carries out the calculation of possible phase changes and gives their location. Expander Pipe segment Vapor ejector A VAPOR EJECTOR is a device fed with two fluids, a primary fluid and a secondary fluid. It allows the compression of the secondary fluid with an enthalpy decrease of the primary fluid. Vapor ejector Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 21 / 21

Expansion valve Used to represent an adiabatic expansion of a mixture, making the assumption that the thermodynamic equilibrium is reached. Several feeds can be connected to the unit operation. In this case, these feeds are adiabatically mixed with the lowest pressure of the feeds pressures. In any case, the unit operation only has one outlet, allowing the liquid and vapor phases not to be split at the unit operation outlet (only one outlet stream). Expansion valve Orifice plate Mixer Used to represent an adiabatic expansion operation of a mixture making the assumption that the thermodynamic equilibrium is reached. The main function of an orifice plate is to measure a fluid flowrate. This type of unit operation is the simplest and the cheapest to reduce pressure. Like every de-pressurizing unit operation, this one is inserted into a pipe in order to limit a fluid flow and to create a pressure drop. The main application is to measure the flowrate of the fluid according to the Bernoulli theorem. Used to mix several streams to obtain a single outlet stream Orifice plate Mixer Static mixer Other mixer Stream splitter Divides the stream resulting from the feeds adiabatic mixing into several streams of the same composition, temperature and pressure. Stream splitter Three way valve Component splitter Makes it possible to separate the components of one stream between several streams. The recovery ratio of each component in the first outlet stream is fixed and also in intermediate sidestream. The rest of the feed is put in the last stream (bottom product). This unit operation can be used to simulate the calculation of a separation process in a simple and not time consuming way. Component splitter Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 22 / 22

Belt filter Makes it possible to simulate a belt filter to perform liquid-solid separation. Calculation is performed from knowledge of cake moisture, solid fraction in the filtrates and solid separation fractions of the components in the mixture. The filter is fed by a suspension and eventually by wash water for belt and/or for vacuum chambers. A solid phase and a filtrate are recovered as outlet streams. Belt filter Filter press Makes it possible to simulate a filter press to perform liquid-solid separation. Calculation is performed from knowledge of cake moisture and solid fraction in the mother liquors leaving the filter. The filter is fed by a suspension. A solid phase and a filtrate are recovered as outlet streams. Plate frame filter Clarifying filter Makes it possible to simulate a clarifying filter to perform liquid-solid separation. Calculation is performed from knowledge of solid fraction in the sludge and in the overflow settler. The filter is fed by a suspension. A clarified effluent and sludge are recovered as outlet streams. Clarifier Hydrocyclone Makes it possible to simulate an hydrocyclone to perform liquid-solid separation. Calculation is performed from knowledge of solid fraction in the solids discharge and in the liquid discharge. A calculation for each component is also possible from knowledge of splitting ratios for n-1 components. A top discharge clarified stream and a bottom rich solid discharge streams are recovered as outlet streams. Hydrocyclone Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 23 / 23

Tank (solid-liquid separation) Calculates the liquid and/or vapor outlet streams from the mixture of the inlet streams, as well as the residence time in the tank from the supplied tank volume, using only the liquid phase. No reaction is taken into account. The tank is assumed adiabatic. Liquid-solid crystallizer Allows to model any equipment for separation of a solid phase and a liquid phase making the assumption that the thermodynamic equilibrium is reached. Moreover, it is possible to define some parameters that can take into account the deviation from the thermodynamic equilibrium. This unit operation can be used to calculate only the saturation level of the studied solution. Tank Liquid-solid crystallizer Evaporator-crystallizer Used to model any equipment for separation of a solid phase, a liquid phase and a vapor phase, making the assumption that the thermodynamic equilibrium is reached. Moreover, it is possible to define some parameters that can take into account the deviation from the thermodynamic equilibrium. This unit operation can be used to calculate only the saturation level of the studied solution. Evaporator-crystallizer Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 24 / 24

Heat pump Objectives: Simulation of the transfer of heat from one medium considered as a transmitter (supplier medium) to a medium considered as a receptor of calories. Depending on the direction of the transfer, the heat pump can operate as a radiator (heat cycle) or as a refrigerator (refrigeration cycle). Main purpose: - Cool the hot utility Refrigerating unit operation (RU) - Heat the cold utility Heat pump unit operation (HP) Includes the following equipment: - A condenser - An expander or a turbine - An evaporator - A compressor Generalized heat pump The GENERALIZED HEAT PUMP unit operation is a unit for the simulation of heat transfer from one medium considered as a "transmitter" (supplier medium) to a medium considered as a "receptor" of calories. Depending on the direction of the transfer, the heat pump can operate as a "radiator" (heat cycle) or as a "refrigerator" (refrigeration cycle). The Generalized heat pump unit operation benefits compared to the Single heat pump unit operation are the following ones: reduction of the compressor discharge temperatures; very low evaporation temperatures; increased efficiency of the thermodynamic efficiency of the machine. The main purpose of the Generalized heat pump unit operation may be: either to cool the hot utility-> Refrigerating unit operation (RU) or to heat the cold utility -> Heat pump unit operation (HP) In ProSimPlus, the Generalized Heat Pump unit operation includes the following equipment: A condenser (countercurrent heat exchanger); Two expanders; An evaporator (countercurrent heat exchanger); Two compressors; An intermediate exchanger. Heat pump C E Generalized heat pump Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 25 / 25

Organic rankine cycle The Organic Rankine Cycle unit operation allows the simulation of a thermodynamic cycle with a dual heat source in order to produce power with a turbine. Using an organic fluid allows to use the heat sources at low and mean temperature and to improve the expander efficiency. The mechanical work produced by the turbine is used to produce power with an alternator. This unit operation incorporates the following elements: A condenser (countercurrent exchanger); A pump; An evaporator (countercurrent exchanger); A turbine. It is possible to improve the efficiency by adding a heat recovery exchanger between the outlet fluid of the turbine and the outlet fluid of the pump. A part of the power of the turbine outlet stream is no longer sent to the condenser but recovered to pre-heat the pump outlet fluid and to decrease the heat consumption to the evaporator. Organic rankine cycle Fuel engine The Fuel Engine unit operation is a complete combustion unit of a fuel, generally gaseous, by a combustive stream. The first aim of this unit operation is to produce electricity using a shaft and an alternator. The unit operation includes the following equipment: A combustion chamber with a mechanical shaft and an alternator: the power released by the fuel consumed is partially turned into mechanical power through a mechanical shaft. This mechanical power is converted into electricity in an alternator. A cooling heat exchanger of the engine, called Low Temperature exchanger (LT). This exchanger is compulsory for the smooth running of the engine, as it allows to cool the mechanical parts of the engine. The cooling fluid circulates in closed loop between the engine and the exchanger. Heat exchangers on fumes, called High Temperature exchangers (HT). The combustion power that is not completely transformed into electrical power and that is not released by the cooling fluid produces high temperature fumes. It then becomes possible to recover this power using HT exchangers. In the Fuel engine unit operation, you can define up to two HT exchangers. Fuel engine Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 26 / 26

Fuel turbine The general purpose of the Fuel turbine unit operation is to simulate a thermodynamic rotating machine. It aims at producing mechanical energy by a shaft rotating directly from the kinetic energy of the gases produced by a combustion. The combustion gases expansion creates a mechanical work by means of a turbine. The mechanical work is used for the electricity production through an alternator. The specificity of the Fuel turbine is that the turbine and the compressor are on the same rotation axis; there is only one alternator efficiency. The Fuel turbine unit operation includes: A compressor. A combustion chamber. A turbine. Fuel turbine Boiler The BOILER unit operation is a complete combustion unit of a gaseous or liquid fuel by a combustive. The aim of this module is to produce hot fumes to produce a utility fluid (generally vapor from liquid water). Boiler Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 27 / 27

ENERGY EFFICIENCY Unit operation Short description Module on the flowsheet Pinch analysis The pinch unit operation is used to carry out energy integration calculations with the pinch method in ProSimPlus. Such energy integration allows to determine the minimum process utilities consumption required. From the enthalpy curves of each stream, the hot and cold composite curves are graphed. According to the pinch acceptable for the whole process (minimum temperature difference between the hot streams and the cold streams), the minimum needs in utilities (hot and cold) are also calculated. The pinch unit operation is aware of all unit operations where a heating or a cooling occurs (boiler and column condenser, heat exchangers, flash, reactors...). Pinch analysis Exergy balance The exergy balances unit operation is used to carry out exergy calculations on all or part of the process. The outlet streams from the process may be considered "waste" if they are not recovered directly (for instance byproducts of reaction). The exergy balances may be carried out on all or part of the process, or a balance for each unit operation can be performed in addition to a global balance. In order to carry out balances on the process where the composition changes, it is possible to select the calculation of the chemical exergy in addition to the physical exergy. Depending on your process, the exergy balance module calculates physical exergy, thermal exergy, mechanical exergy, chemical exergy (if required), working exergy, heat exergy, exergy losses (physical, chemical, heat), maximum quantity of recoverable mechanical exergy, maximum quantity of recoverable thermal exergy, intrinsic efficiency, simple efficiency (or system yield), and irreversibilities (relative and intrinsic). Exergy balance Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 28 / 28

ECONOMIC EVALUATION Unit operation Short description Module on the flowsheet Economic evaluation (COST) The Economic evaluation module is used to estimate the gains and the costs associated to a process and provides the initial and secondary investment costs, operating gains and costs, maintenance costs, economic indicators, schedule, and economic indicators profiles. This functionality takes the form of a unit operation placed on the flowsheet, that may also be connected to information streams. You can use two methods included in ProSimPlus that are based on the Manual of Process Economic Evaluation*: the Functional Module Method or the Pré-Estime Method. Or enter your own correlations for each unit operation. * A. CHAUVEL, G. FOURNIER, C. RAIMBAULT «Manual of Process Economic Evaluation New, revised and expanded edition» Editions TECHNIP (2003) Economic evaluation (COST) Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 29 / 29

OPTIMIZATION AND DESIGN SPECIFICATIONS Unit operation Short description Module on the flowsheet Constraints and recycles The SPECIFICATION block unit applies an operating constraint or an objective to reach in terms of purity, flowrate, temperature... at a given place of the process by acting on an operating parameter of a unit operation located at another place of the same process. The SPECIFICATION block unit, INFORMATION STREAM HANDLER block unit, and the MEASUREMENT block unit can be used to handle constraints and recycles. Specification Information stream handler The INFORMATION STREAM HANDLER block unit makes it possible to modify the value of one (or of several) information stream using a by basic operations. The basic equation that makes this transformation possible is: Output Information Stream = A*(Input Information Stream) P + B - C where A, B, C and P can be constants or information. The exponent P can be integer or real, positive or negative. The SPECIFICATION block unit, INFORMATION STREAM HANDLER block unit, and the MEASUREMENT block unit can be used to handle constraints and recycles. Information stream handler Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 30 / 30

Measurement The MEASUREMENT block unit makes it possible to extract the value of a variable (temperature, pressure, total flowrate, and partial flowrate or composition) from a stream and to compare this value with a set point. This block unit is connected to a material input stream and a material outlet stream and must be associated to an outlet information stream. It is usually used in connection with a SPECIFICATION block unit but can also be used with a WINDOWS SCRIPT unit. The SPECIFICATION block unit, INFORMATION STREAM HANDLER block unit, and the MEASUREMENT block unit can be used to handle constraints and recycles. Measurement ph meter The ph meter is used to calculate : The ph of an outlet stream (from the activity instead of the concentration) All the characteristics of the solubility of the salts It is necessary to use an appropriate thermodynamic model (i.e. all the electrolytic models except the Engels model). ph meter Solid solubility measurement The solid solubility measurement is used to calculate the solid solubility of an outlet stream. Solid solubility measurement Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 31 / 31

Optimization The OPTIMIZATION block unit is used to solve problems of minimization in continuous variables with or without constraints. The objective of this block unit is to minimize a criterion function described, whatever its form may be, by action on the operating parameters selected, while respecting possible constraints. The expressions characterizing the criterion and the constraints can possibly take nonlinear forms. Optimization Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 32 / 32

UTILITIES AND TOOLS Unit operation Short description Module on the flowsheet HCurves The HCURVES tool makes it possible to calculate enthalpy curves. The HCURVES calculations are carried out after convergence of the simulation file. For modules in which HCURVES calculations are planned (heat exchangers, flashes and columns), the calculation range of the HCURVES is perfectly defined and corresponds to input and output conditions of the module. Two calculation modes are proposed: Temperature and pressure increments fixed (succession of flash calculations at given pressure and temperature), Heat duty and pressure increments fixed (succession of flash calculations at given enthalpy and pressure). Four calculation modes can be specified in the HCURVES modules positioned on the streams: Temperature and pressure increments fixed (succession of flash calculations at given pressure and temperature) Heat duty and pressure increments fixed (succession of flash calculations at given enthalpy and pressure) Calculation of a bubble curve Bubble temperature or Bubble pressure Calculation of a dew curve Dew temperature or Dew pressure HCurves Calculator switch The CALCULATOR SWITCH unit operation allows changing the thermodynamic calculator of a material stream when it enters another unit operation with a different thermodynamic model. This change is required, notably when the two calculators do not use the same enthalpy basis, the same enthalpy calculation path or the same thermodynamic approach. By default, the outlet conditions are taken equal to the inlet conditions, and the physical state as well as the enthalpy are recalculated. However, it is also possible to specify to keep the inlet physical state; in this particular case the temperature and the enthalpy are being recalculated. The enthalpy deviation due to this calculator change is printed in the simulation report (as absolute and relative deviations). Calculator switch Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 33 / 33

USER DEFINED UNIT OPERATIONS Unit operation Short description Module on the flowsheet Windows scripts The WINDOWS SCRIPT module makes it possible to create quickly and simply new calculations modules (unit operation or other type of modules) in the ProSimPlus simulation environment. These modules, once created, can be used exactly in the same way as those which are provided with ProSimPlus. Their use is completely transparent and does not need any additional handling. Each Windows Script module is described (programmed) directly in the ProSimPlus graphical environment using a simple but powerful language. This language, Microsoft VBScript, is a simplified version of Microsoft Visual Basic. It allows writing the source code of a module in a few minutes. A specific help is available directly from the unit operation s main window Script module CAPE-OPEN unit operation Use CAPE-OPEN compliant unit operations from third party process simulators. CAPE-OPEN defines a set of standardized interfaces for the use of a unit operation in a steady state process simulator adopting a sequential resolution. The CAPE-OPEN unit operation allows the use of this type of unit operation in ProSimPlus. More information about CAPE-OPEN is available at http://www.colan.org/ CAPE-OPEN User defined unit operation (UTI) Every ProSimPlus user can create their own modules in addition to those available in the standard ProSimPlus library. Several integrated development environments can be used, including Visual Fortran (preferred and recommended), C or C++, Visual Basic or other languages. These modules, once programmed by the user, can be used exactly in the same way as those which are provided with ProSimPlus. User defined unit operation UTI Copyright 2016 ProSim, Labège, France ProSimPlus Library - version 3.5.11 Page: 34 / 34