K-FLEX Clad Jacketing. Jacketing Systems for Mechanical Insulation

Similar documents
Storage Tanks. Product performance for insulation of large storage tanks

Storage Tanks Product performance for insulation of large storage tanks

Ammonia. Product performance for insulation of ammonia piping

Chilled Water. Product performance for insulation of chilled water piping

PERMATHERM PIPE INSULATION PRODUCTS

GUIDE SPECIFICATION: MECHANICAL SYSTEMS

PERMATHERM, INC. SPECIFICATION FOR CHILLED WATER PIPE INSULATION

PERMATHERM, INC. SPECIFICATION FOR COLD/CRYO PIPE INSULATION

PERMATHERM, INC. SPECIFICATION FOR COLD/CRYO PIPE INSULATION

GUIDE SPECIFICATION: DUCT LINER

SECTION HVAC INSULATION

Air and Vapor Barrier 3015

TAPE SOLUTIONS FOR HVAC SHURTAPE.COM TAPE

PITTWRAP B100 JACKETING Product Datasheet

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

PITTWRAP CF JACKETING Product Datasheet

INSTALLATION GUIDELINES FOR CHILL WATER PIPE INSULATION

PITTWRAP CW PLUS JACKETING Product Datasheet

Ultra High Bond Tapes...

ArmAcell solutions for systems refrigeration, Air- conditioning & VeNtilAtioN

FLEXIBLE MECHANICAL PROTECTION

PRODUCT SELECTION GUIDE

EFFISUS EASYREPAIR MEMBRANE

PITTWRAP HS (HEAT SEAL) JACKETING Product Datasheet

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

K-FLEX DUCT LINER GRAY

LEED POINT ELIGIBLE, AIRTIGHT GREEN POINT CONTRIBUTORS SHURTAPE.COM TAPE

1 of 17. PO Box Bellevue Rd, Newark, DE V F

REFERENCE ARMA-CHEK SILVER

REFERENCE ARMA-CHEK SILVER

a d v a n c e d e l a s t o m e r i c t h e r m a l a n d a c o u s t i c i n s u l a t i o n m a t e r i a l s

K-FLEX USA MECHANICAL INSULATION CONTENTS: SPECIFICATION GUIDE PRODUCT SELECTION GUIDE LEED CONTRIBUTION GUIDE

PRODUCT CATALOGUE PROFLEXR. Thermal Insulation. CFC free HCFC free Zero Ozone Depletion Potential (ODP) Taking care of energy and Environment

Pressure Sensitive Tapes for Industrial Insulation and General Purpose

Tube Insulation. Fiber Free

INSTALLATION GUIDELINES FOR COLD/CRYOGENIC PIPE INSULATION

K-FLEX. K-FLEX Tapes. for HVAC and industrial application

Mechanical Insulation for Refrigeration Systems

B C M T e c h n i c a l, L L C A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I P h o n e : T o l

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING

A. Submit product data sheets and literature verifying physical properties of materials.

TEKTON Flashings and TEKTON Construction Tape

FlexClad Duct and Pipe Sealing System

Extreme Sealing Tape

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

SECTION INSULATED METAL ROOF PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology

B. Refer to Section : Air Distribution for lined ductwork requirements.

AIC Tech Energy Efficiency - Road Map to a Sustainable Future

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

DMS-6300, Waterproofing

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS

Silicone Material Selection Guide

Extreme Sealing Tape 4412N

SMARTCARE DAMP PROOF TECHNICAL PARAMETERS

LT/ArmaFlex. Industrial INSULATION FOR THE OIL AND GAS INDUSTRY. High density industrial grade FEF installation

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for LIQUEFIED NATURAL GAS (LNG) CRYOGENIC REFRIGERATION CHILLED WATER

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

SUPAFLEX SUPAFLEX DESCRIPTION TUBING:

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

WATERPROOFING. MiraPLY -V with SeamLOCK Technology SCIENCE. SERVICE. SOLUTIONS. Standards. Description. Typical Properties.

Friendly Feel Duct Wrap with KwikStretch Markings. Knauf Data Sheet AH-DS

220 E. General Robinson St. Pittsburgh, PA fax

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

Technical Bulletin July, 2013

VHB 9460PC Adhesive Transfer Tape

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

Imagine a product which. waterproof your surface, saves. paint cost, protect the structure. from ageing and remain on the. surface forever...

Student Services & Classroom Addition

A. Submit product data sheets and literature verifying physical properties of materials.

Redi-Klad 1000 Pipe Insulation

Pressure Sensitive Adhesives for HVAC/R, Mechanical and Metal Building Insulation. Tapes, Fasteners & Sealants Product Catalog

Tapes, Fasteners & Sealants. Product Information Guide. The right solutions. The right products.

SECTION FLUID-APPLIED WATERPROOFING

TOPCOAT System Specifications Corrugated Transite Panels

Firestone UltraPly TPO The light colored roofing choice

THE PRE-COVERED ARMAFLEX INSULATION DESIGNED FOR FAST INSTALLATION, DURABILITY AND EASY CLEANING

Perm-A-Barrier NPS (Non Permeable Sheet)

EPDM ROOF RESTORATION

GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE

Pressure Sensitive Tapes. for Insulation and General Purpose. Innovative Insulation Specialties. Abatement. Industrial. Packaging

Product Guide Specification

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

K-FLEX K-FONIK INDUSTRIAL

INSTALLATION GUIDELINE FOR TRYMER INSULATION

HVAC INSULATION. A. General Requirements for Flexible Elastomeric Insulation: 3. Use pre-molded roll on pipe sizes 3.5" and below.

A. Submit product data sheets and literature verifying fire ratings and physical properties of materials.

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION 8130 XR-3-PW FABRIC BAFFLE WALL SPECIFICATION

4411N 4411G 4412N 4412G

Division 15 INSULATION Section 15100

J&L Building Materials, Inc. Commercial Roofing

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

PROJ. NO SECTION HVAC DUCT INSULATION

RECOMMENDED DESIGN SPECIFICATION

Limited Time. Job-Ready. Value Priced.

Applications (Rubber/Rubber) (Acrylic/Acrylic)

SECTION PLUMBING INSULATION

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC INSULATION

Transcription:

K-FLEX Clad Jacketing Jacketing Systems for Mechanical Insulation

ABOUT K-FLEX USA Youngsville, NC Headquarters K-FLEX USA IS A LEADING MANUFACTURER of closed cell fleible elastomeric foam insulation products for mechanical piping, air handling units and vessels. Designed for ease of installation and reliable performance, K-FLEX products provide ecellent thermal and acoustical performance, including inherent resistance to moisture intrusion. K-FLEX USA prides itself on being responsive to the market, providing dependable service to customers throughout North America, bringing an innovative approach to product offerings, and having products that are 3rd party tested and certified. In April 2012, K-FLEX USA was awarded with ISO 9001:2008 certification by FM Approvals. The independent certification demonstrates the company s commitment to quality. K-FLEX products have proven performance in the Plumbing, HVAC/R, Commercial/ Industrial, Marine, Oil & Gas, Acoustic and OEM Markets. As a member of the IK Insulation Group, K-Fle USA delivers state-of-the-art levels of technical knowledge and customer support to the global mechanical insulation market. COMPANY HISTORY 1965 Rubate was formed. 1989 L Isolante K-FLEX was formed. 2001 Nomaco Insulation and L Isolante K-FLEX join to form Nomaco K-FLEX (NKF). 2004 NKF acquires RBX s mechanical insulation business. 1975 Halstead was formed and INSUL-TUBE became a wellknown product brand. 1999 Rubate acquires Halstead to form RBX Industries. 2002 NKF enters into a Sales and Marketing Agreement with RBX Industries. 2008 Jan. 10, 2008 L Isolante K-FLEX redeems Nomaco shares in NKF and goes to market as K-FLEX USA. K-FLEX USA BENEFITS Designed for lasting performance Easy-to-Use Products Responsive to market Industry & Product epertise 3rd Party Certified Products Broad Product Range Systems Approach Factory-applied PSA & Cladding to Insulation Full line of accessories (tapes, adhesives, etc) GLOBAL PRESENCE L ISOLANTE K-FLEX: 11 production facilities worldwide Commercial distribution in 43 countries Headquartered in Italy 2

K-FLEX CLAD JACKETING PRODUCTS K-FLEX Clad Jacketing products are unique to the insulation market, offering many advantages over traditional coating or jacketing systems. The product is manufactured under controlled conditions using automated equipment to eacting tolerances. The product line offers several products, each offering features and benefits for specific applications. All Clad Jacketing products offer features such as: fleible, dent resistant, easy to fabricate and install, low cost and long lasting performance. The K-FLEX Clad Jacketing line is an etension of, and complement to, K-FLEX s fleible closed cell foam elastomeric insulation products. K-FLEX Clad Jacketing is available factory-applied to K-FLEX insulation (tube, sheet or roll form) or sold separately with or without PSA (adhesive). Matching accessory sealing / edge tapes, contact adhesives and plastic fastening rivets complete the product line. K-FLEX Clad Jacketing is available in 3 grades: Clad AL 3-ply (PVC/aluminum foil/mylar film) 12 mils Color silver 48 wide 75 long roll (with or without PSA) Clad WT 3-ply (PVC/aluminum foil/mylar film) 12 mils Color white 48 wide 75 long roll (with or without PSA) Clad IN PATENT PENDING Single-ply Polymeric (CPE) 45 mils Color gray or black (pictured to right) 39 wide 75 long roll K-FLEX Clad Jacketing products are designed to offer an alternative to traditional PVC or Metal (Aluminum or Stainless Steel) jacketing. They offer the following advantages over traditional jacketing: Easy to install fabricates with a knife / glued seams (reference K-FLEX Installation Manual for detailed instructions) Can be applied to interior and eterior ductwork (rectangular/round), pipes (straight runs, bends, intersections), and vessels Fleible Dent resistant Low perm moisture resistant Moisture tight seams UV resistant Cost effective Can be factory-applied to insulation (tubes or sheets) K-FLEX ADHESIVES and TAPES K-FLEX Clad Jacketing products can be purchased in rolls with (AL/WT only) or without a PSA adhesive. For applications where the jacketing is going to be attached 100% to the surface / substrate that it is covering, it is recommended that the product be purchased with a factory-applied PSA. The factory-applied PSA is an aggressive acrylic adhesive with an easy to release, tear-resistant poly release liner. For applications where the jacketing is purchased without PSA (only the longitudinal seam is sealed), K-FLEX offers several solvent-based contact adhesives for securing the seam. In addition, plastic rivets are available for use with K-Fle Clad AL or WT. Matching Clad tapes for sealing butt joints, longitudinal seams and edge covering are available for use with K-Fle Clad AL or WT. The aggressive butyl adhesive supplied on the tape offers ecellent bond strength and low temperature fleibility. K-Fle Clad IN strips (without PSA) are available for use as butt strips or edge covering - using contact adhesive to secure. 3

K-FLEX CLAD AL JACKETING K-FLEX Clad AL Jacketing is ideal for outdoor (roof top) applications as a replacement for aluminum jacketing. It is suitable for covering insulation products used in plumbing (hot/cold water), HVAC (air conditioning / chilled water / ducts) and refrigeration applications. Manufacturing plants such as food processing, pharmaceutical facilities, film processing, or electronics where piping or tanks are located outdoors and require insulation and jacketing would be ecellent choices for Clad AL Jacketing. The cladding provides weather and abuse resistance, as well as protection from UV rays. The smooth shiny surface is easy to clean, dust free, resistant to acids, alkali, salts, oil, fats, and aliphatic hydrocarbons and is highly impermeable to gases and moisture (0.001 Perm when tested according to ASTM E 96). Clad AL Jacketing does not dent like traditional metal jackets, has ecellent appearance and is easy to maintain and repair if necessary. Clad AL Jacketing has a high emissivity (.80) that makes it ideal for jacketing over insulation on low temperature lines. Clad AL Jacketing combines the advantages of aluminum jacketing (UV, moisture and abuse resistance) with those of PVC jacketing (dent resistance, easier installation, and moisture tight seams: 0.003 perms when tested to ASTM E96). ATTRIBUTES K-FLEX CLAD AL TEST METHODS Thickness 0.012 Reaction to Fire 25/450 ASTM E 84 Water Vapor Permeance 0.001 perms ASTM E 96 Weather, UV Resistance Ecellent ASTM G 53 Corrosion Risk Provides protection for corrosion under insulation (CUI) Salt Spray Resistance Ecellent BS 903 F12 Wear Resistance Ecellent BS 903 A2 Ozone Resistance Ecellent BS 903 A43, ASTM D1171 Chemical Resistance Ecellent Acids, Alcohols, Alkalies, Oils Puncture ø 3.0 mm 100 N pren 14 477 Emissivity 0.80 ASTM C 1371 Tensile Strength 90 lbs per ft ASTM D 828 Burst Strength 203 psi ASTM D 774 Dimensional Stability (length change) -1% ASTM D 1204 Color Silver 4

K-FLEX CLAD WT JACKETING K-FLEX Clad WT Jacketing is ideal for outdoor (roof-top) and indoor applications (25/50 rated for fire and smoke when tested to ASTM E 84) including supermarkets, food processing plants, pharmaceutical facilities, fi lm processing centers, electronics facilities and other clean room applications. When applied to K-Fle closed cell elastomeric insulation, the Clad WT Insulation System is NSF approved for use in food prep or washdown areas. It is suitable for covering insulation products used in plumbing (hot/cold water), HVAC (air conditioning / chilled water / ducts) and refrigeration applications. The cladding provides weather and abuse resistance, as well as protection from UV rays. The smooth white surface is easy to clean, dust free, resistant to acids, alkali, salts, oil, fats, and aliphatic hydrocarbons and is highly impermeable to gases and moisture (0.001 Perm when tested according to ASTM E 96). Clad WT Jacketing does not dent like traditional metal jackets, has ecellent appearance and is easy to maintain and repair if necessary. With a gauge of.012, it has ecellent puncture resistance. Clad WT Jacketing has a high emissivity (.80) that makes it ideal for jacketing over insulation on low temperature lines. The white jacketing offers the toughness and aesthetics of PVC with etremely low permeance, UV resistance and moisture tight seams: 0.003 perms when tested to ASTM E96. ATTRIBUTES K-FLEX CLAD WT TEST METHODS Thickness 0.012 Reaction to Fire 25/50 ASTM E 84 Water Vapor Permeance 0.001 perms ASTM E 96 Weather, UV Resistance Ecellent ASTM G 53 Corrosion Risk Provides protection for corrosion under insulation (CUI) Salt Spray Resistance Ecellent BS 903 F12 Wear Resistance Ecellent BS 903 A2 Ozone Resistance Ecellent BS 903 A43, ASTM D1171 Chemical Resistance Ecellent Acids, Alcohols, Alkalies, Oils Puncture ø 3.0 mm 100 N pren 14 477 Emissivity 0.80 ASTM C 1371 Tensile Strength 90 lbs per ft ASTM D 828 Burst Strength 231 psi ASTM D 774 Dimensional Stability (length change) -1% ASTM D 1204 Color White 5

K-FLEX CLAD IN JACKETING K-FLEX Clad IN Jacketing is ideal for outdoor / industrial / marine applications eposed to wide temperature cycling, including industrial plants, operating mills (pulp / paper), off shore platforms, FPSOs, LNG terminals, storage tanks and shipping vessels. K-FLEX Clad IN Jacketing is a patent pending, fl eible non-metallic, polymeric (CPE) protective jacketing suitable as a covering for all insulation types. It is wellsuited for etreme temperature cycling PATENT PENDING applications due to the ability of the polymeric covering to epand and contract with rapid temperature swings. It provides ecellent resistance against UV, high humidity, salt spray, weather, acids, oils, chemicals, impact, mechanical abuse and moisture vapor intrusion. Clad IN Jacketing has a high water vapor diffusion resistance (0.08 Perm when tested according to ASTM E 96) and practically eliminates the problem of under insulation corrosion. It is easy to install and combines ecellent performance with easy maintenance. The cladding is fleible enough to protect against damage from foot traffic (does not dent like traditional metal jackets) and maintains moisture proof seams. The 0.045 gauge offers ecellent puncture resistance. The seams can be sealed with solvent-based contact adhesive. Clad IN Jacketing is available in gray or black - each of which has a high emissivity (.90) that is ideal for insulation over low temperature lines. ATTRIBUTES K-FLEX CLAD IN TEST METHODS Material Type Chlorinated Polyethylene (CPE) Color Gray or Black Thickness.045 (1.2 mm) Water Vapor Permeance 0.08 perms ASTM E 96 Specific Weight 1.8 +/- 0.1 g/cc Hardness >=80 sha ISO 7619, ASTM D 2240 Tensile Strength >=6.9 MPa ISO 37 (Typical value 7.5 MPa) Elastic Modulus >=60 MPa ISO 37 (Typical value 70 MPa) Modulus 10% >1.5 MPa ISO 37 Elongation to Break >100% ISO 37 (Typical values: elongation @ 70%, elongation to break 300%) Peel Adhesion >50 Kpa ISO 2411 Shear Strength >20 N/25mm ISO 34-1 Ozone Resistance Etremely Good ASTM D 1171 (72hr 50ppm 20%, no oidation) UV Resistance Etremely Good ASTM G 7-97 (2 years of eposure in New River, AZ: no pitting, no cracking, no blistering) Salt Spray Resistance Etremely Good ISO 3768, ASTM B 117-73 (480 hrs: no color shade, no scaling, no blistering) Aging Resistance Etremely Good ISO 4982 (after 360 hr, 72 MJ, elongation to break and modulus conform to specification) Oil Resistance Etremely Good ISO 1817 (after 72 hr immersion in oil IRM 903, elongation to break and modulus conform to specification) Chemical Resistance (Acids, Alcohols, etc) Etremely Good Impact Resistance Etremely Good EN12691; 1Kg, 20mm, 600mm High Surface Temperature Limit (continuous) 175 F (80 C) temperature of ambient air & insulation surface Cold Temperature Fleibility (for installation) -4 F (-20 C) ISO 812:2006 Emissivity 0.90 Corrosion Risk (CUI) Protects against corrosion under insulation Combustibility Pass BS 476 pt 6 / BS 476 pt 7 / NF 92501 Fire Requirements for Building Construction 15/250 (Class A) ASTM E 84 Fire Requirements for Shipbuilding Pass IMO 61/67 part 2&5 Approvals and Supervisions CE marine approval Type approvals CSI ABS / DNV / Lloyds Register / Norsok Standard R-004 ed 3 (par. 5.9 non-metallic jacket) 6

COMPARISON: JACKETING OPTIONS ATTRIBUTES K-FLEX CLAD (AL/WT/IN) COATINGS PVC METAL FLEXIBLE MULTI-PLY Fleible UV Resistant Mechanical Abuse Protection Dent Resistant No Caulking of Seams Water Resistant Moisture Vapor Resistance Limited Maintenance Required Easy Removal / Repair Jacket Thickness (inches).012 (WT/AL),.045 (IN).002.016.016 varies Mold Resistant Easy-to-Clean High Emissivity (>0.80) for best condensation control Available in white & aluminum (color) Total System Approach Glued Seams Available with Matching Fittings Available with Matching Tape for Seams & Edges COMPARISON: JACKETING FACTORY-APPLIED TO INSULATION ATTRIBUTES K-FLEX CLAD (AL/WT/IN) COATINGS PVC METAL FLEXIBLE MULTI-PLY Factory-Applied: 1-piece construction Adhered 100% to Insulation Overlap Seam Factory-applied (tubes) Factory-applied (sheets) GREENGUARD (low VOC) (AL, WT) NSF Approved (WT) Uniform Appearance (no ripples/air bubbles/ streaks) Faster Installation (1-step) 7

ISO 9001 Certified www.kfl eusa.com tel. 800-765-6475 100 Nomaco Drive Youngsville, NC 27596 KFAP-0007-0815