Property Address: Sample.Prehandover.report

Home Inclusions $410, HOME & LAND PACKAGE MARCOOLA Land Content $ MARCOOLA. 4 Bedroom 2 Bathroom Multiple living zones Alfresco

160.F1 PROPERTY INSPECTION REPORT 6 Vitoria St, Sebastopol, 3356 INSPECTION DETAILS Registered Practitioners Signature:

Powder Coated Merino. Colorbond Dune. Concrete Tiles- Concrete Tiles Slate Grey Finish. Colorbond Paperbark. Concrete Tiles- Concrete Tile -

LOT 25 Blueleaf Place. Brookfield $511,879 SUMMARY

DESIGNER INCLUSIONS DISPLAY CENTRE LOCATIONS SOUTH WEST NORTH WEST HEAD QUARTERS HOOTHOMES.COM.AU. Hillcroft Estate 28 Dowie Street CLAYMORE NSW 2559

SCHEDULE OF INCLUSIONS

STANDARD SPECIFICATIONS. Page 1

RENDERS ARE INDICATION ONLY. Land. Home size 26sq. 28 Ajay Way, Kurunjang LEGACY 26 $545,500 ACTUAL HOUSE IMAGE PRESENTED BY

HOME & LAND $946,000 LOT 155 THE HILLS ESTATE BOX HILL BRONTE 182

Executive Inclusions PRELIMINARIES:

STANDARD VISUAL PRE-PURCHASE BUILDING AND PEST INSPECTION REPORT

LOT 1331 BRENTWOOD FOREST HOUSE AND LAND PACKAGE PRICE $474,977

W i s d o m S m a r t C o l l e c t i o n. Aristotle series

DRMB BUILDING GROUP SPEC INCLUSIONS JOB ADDRESS NO 4 Deborah Court Mt Waverley vic

BUILDING INSPECTION. Mar 16, 2015 PROPERTY ADDRESS Killymoon Drive Hope Island, QLD 4212, Australia. 1 of 44

Whether you re buying or investing, a Buy-Wise Building & Pest Inspection will tell you of everything you need to know about your new property.

DUO Contemporary- Ash 1

KEVIN BURNS BUILDING INSPECTIONS REGISTERED BUILDER PRE-PURCHASE VISUAL STRUCTURAL INSPECTION REPORT No. 822

NOBLE S WAY with Schedule of Finishes

Classic Living INCLUSIONS

INSPECTOR GROUP PTY LTD

The Express Range. It s your home. The Express 12

Inspection details. Subfloor. Subfloor. Before You Buy property inspection

Metriton Standard Inclusions

KOOKABURRA HOMES TWO STOREY HOMES. Standard Inclusions. kookaburrahomes.com.au

Home Inclusions or Domainehomes.com.au

Standard Inclusions for

W i s d o m S m a r t C o l l e c t i o n. Inspiration series

proposed dwelling fjm homes lot 7 wrinklers drive scamander tasmania 7215 concept design jennifer binns Building Areas

the evolution 2015 series

KOOKABURRA HOMES STANDARD INCLUSIONS TRANSPORTABLE HOMES. MURRAY BRIDGE STANDARD INCLUSIONS + PRICE LIST 1

2018 AUSTERE NSW TURN-KEY INCLUSION SPECIFICATIONS (PER DWELLING WHERE APPLICABLE):

KOOKABURRA HOMES BRICK HOMES. Standard Inclusions. kookaburrahomes.com.au

W i s d o m H o m e s C o l l e c t i o n. Ambassador series

PRE-PURCHASE STANDARD BUILDING REPORT

Visual Property Inspection Report Complies with Australian Standard AS

ORION ORION INCLUSIONS BROCHURE B RAYBROOK. House type shown: Infinity I, dark colour scheme

THE BEST INCLUSIONS ALTI 202

Trade Licensing Guide Victoria. Use this guide to verify which licensed trade you need for your home improvement job

BUILDING REPORT. 123 Anywhere Street Suburb City. Prepared for: Client NON INVASIVE

Town of Falmouth FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage COSTS FOR SUBSTANTIAL IMPROVEMENTS / REPAIR OF SUBSTANTIAL DAMAGE:

Bathrooms. Custom cabinetry INCLUDED

City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage

W i s d o m S m a r t C o l l e c t i o n. Newton series

Inspection Report. 1 of 8

MAIN & AUX/ASSOCIATED UNIT - Specification

PRACTICAL COMPLETION REPORT

KOOKABURRA HOMES TRANSPORTABLE HOMES. Standard Inclusions. kookaburrahomes.com.au

City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage

$535,536 FIXED PRICE HOUSE & LAND PACKAGE. 14.0m FIRST HOME BUYER $525,536* Kiama 226

owner builders construction guide copyright - pdh estimating - june 2004

This report is produced without prejudice.

Home Inclusions or Domainehomes.com.au

Trade Licensing Guide Queensland. Use this guide to verify which licensed trade you need for your home improvement job

KOOKABURRA HOMES STANDARD INCLUSIONS CLASSIC HOMES

Checklist for Tradies

UPPER POINT COOK. Upper Point Cook Point Cook, Victoria

access INCLUSIONS With our Access range of inclusions, you can move in and just enjoy living.

KEVIN BURNS HOMES PRACTICAL COMPLETION REPORT VISUAL BUILDING INSPECTION REPORT

This report is produced without prejudice.

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

MEKI 125. Details. 3 Bedrooms. 2.5 Bathrooms. Single Carport. 2 Living Areas. Min. Block Size: 8.5m x 28m. Ground Floor: 90.87m 2 9.

Call us now on or visit us on The Total Package

kitchen excellence $450 With the Largest Stone Kitchen Island bench available in Perth only Fully Ducted Reverse Cycle Air Conditioning

Your Guide To Our Quality Range Of Exterior And Interior Finishes. Living Inclusions

S pecifications and I nclusions

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

Pink Inspection Services B&R A Division of B&R Constructions Pty. Ltd. ABN

WESTBUILT INCLUSIONS. Standard Inclusions

Inclusions FRAMING GARAGE FIXED SITE COSTS & CONNECTIONS EXTERNAL. 90mm pine wall frames with stabilised pine roof trusses

Affordable Luxury LITCHFIELD. Elevation included. Quality ISO 9001

The Pattison. At a Glance m Study m. 17.

The Banksia. At a Glance m Study m. 18.

Po Box Chartwell 3248 Hamilton Free Ph

Hosies Homes Standard Inclusions:

SS: Standard. The fundamental inclusions for your dream home

Name: Address: Phone: Mobile: Project Address: Lot No. and DP No: Project Type: New Dwelling

Deluxe Inclusions for

QUALITY INCLUSIONS. Quality inclusions from your experienced local builder!

The Integrity 19 by Wisdom Homes On Lot 4318 Hoy Street GEORGES FAIR (or similar 375m block).

PARK VISTA LOT 70 SOUTHWOOD CRT MANGO HILL HOUSE AREAS. LIVING m 2 GARAGE m 2 ALFRESCO m 2 PORCH m 2. TOTAL

2/10 Liuzzi St Pialba Hervey Bay Qld

Call us now on or visit us on The Builders Range Package

Verve Inclusions. 3 Corporate Avenue Rowville VIC T 1800 SIENNA E

ALTI 202. Details. 4 Bedrooms. 2 Bathrooms + Powder. Double Lock-Up Garage. 2 Living Areas. Min. Block Size: 12.5m x 28m

Lot 135, 11 Varsity Crescent, Varsity Park Total Package Price: $445,000

Building Dilapidations International

Inspect Direct Pty Ltd

Inspect Direct Pty Ltd

Our standard inclusions.

PARK FRONTING TOWNHOMES

INCLUSIONS & SCHEDULE OF FINISHES

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

Transcription:

INSPECT DIRECT Ph: 1300 133363 THIS REPORT IS VALID FOR (6) MONTHS FROM THE DATE OF MOST RECENT INSPECTION. REPORT ON DOMESTIC BUILDING WORK UNDER SECTION 137B OF THE BUILDING ACT 1993 (OWNER-BUILDER CONSTRUCTION) Site Address: Sample Report Victoria 3000 Date of report: 24/03/16 Date of inspection: 24/03/16 Weather conditions at time of inspection Fine Cloudy Wet Windy Other (please specify)... Name of prescribed building practitioner: Salvatore Mamone B.Arch (Architect & Registered Building Inspector) Address: 144 Centenary Drive Mill Park Victoria Post Code: 3082 Registration No. Architect:15347 RBP: IN-L 41272 Signature: Salvatore Mamone Report Legend: No Visible Fault M Minor Fault Maintenance Issue X Serious Defect that may potentially adversely affect the structural integrity of the building. XX Serious Major Structural Defect C Incomplete N Not accessible ----------- Not Relevant P Partial Access U Untested Description of the building and materials used in construction: Floor Structure: Stumps / Piers: - Concrete Slab - ---------------------- Footings: - Concrete Floor Coverings: - Tiles. - Carpet Wall Structure: - Timber Frame - Timber Frame Brick Veneer Roof Structure: - Timber Frame External Wall Cladding: - Rendered Brick - Face Brick Internal Wall Lining: - Plaster Internal Ceiling Lining: - Plaster Roof Cladding: - Concrete Tiles Window Frames: - Aluminium Number of storeys: - Single Services connected to the owner built works and their condition: Electrical: Air-Conditioning: Owner Builder defects Report Page 1

Ph: 1300 133363 Gas: Water: Sewerage: Stormwater: Septic:---------- Rain Tank: - PVC: BAL level if known: - Not Known Description of Works: INSPECT DIRECT - Ducted Refrigerate Heating: - Gas Ducted Hot Water System: - Instant Gas Intercom:------------- Alarm System: Ducted Vacuum: Smoke Detectors: New House or Alterations & Additions as instructed by the Owner Builder: 1.0 Single Storey brick veneer house with attached brick garage. 2.0 Metal framed veranda attached to the south side of the house. Property Owner/s Name/s: Name/s: Inspect Direct Name/s:-------------- Address: Sample Address: Victoria 3000 Contact Phone Number/s: 0413 954 947 Site details House location on Street: - West Side Site falls / graded to: - Relatively Flat Vegetation: - Light Site Drainage: - M1 Condition of concrete paths / Paving: - M1 Attached & Detached Structures from the owner built works: Garage / Carport: - Brick Garage Pergola: - -------------------- Veranda: - Colorbond Metal Framed Veranda attached to the south side of the house. - Colorbond roof sheets. - Acrylic clear roof sheets - Colorbond Gutter: C1 - PVC down pipe Front Porch: - Rendered brick. - Tiled Floor Alfresco: - ------------------------ Timber Deck: - -------------------------- Owner Builder defects Report Page 2

Ph: 1300 133363 Bungalow / Studio: - -------------------- Garden Shed: ----------------------------- Pool / Spa: - ----------------------- Pool / Spa Equipment: - ----------------------- Pool / Spa Fence: - ----------------- Retaining Walls: - ------------------- INSPECT DIRECT External Construction: Footings: - Concrete: N If Masonry Damp Proof Course & Mortar Condition: - N (Concealed by rendered along base of rendered walls) Wall Structure: - Brick Veneer: Wall finish: - Render: - Brick: Sub floor Ventilation (Where Applicable): - ---------------- Weep Holes Base of walls (Where Applicable): - M2 Weep Holes above window & door openings in walls (Where Applicable): - Eaves: - --------------- Doors: - Windows: - Aluminium Sill Gaps Ground floor windows: - Sill Gaps upper level windows: - --------------- Roof Cladding: - Concrete Tiles: Fascia Gutters: - Colorbond: Box Gutters: - Zincalume: Flashing & Capping: - Colorbond.: - Zincalume: Flashing to attached structures: - Colorbond: Down Pipes: - Colorbond.: - PVC: Roof pitch: - Aprox: 24 Degrees Owner Builder defects Report Page 3

INSPECT DIRECT Ph: 1300 133363 Miscellaneous: Kitchen Equipment: Hot Water System: Range hood: Cold Water Pressure: Stove / Cooktop: Hot Water Pressure: Oven: Water Hammer: Sink: Fire Place: Dishwasher: Ducted Vacuum: Taps: Entry Hall / Corridor: Cupboard / Cloak: -------- Fly Screen: Weather seals Entry Door & Frame: Living Room: Fly Screen: Joinery / Cupboards: ------- Weather seals External Door & Frame: --------- Dining room: Fly Screen: ------- Joinery / Cupboards: Weather seals External Door & Frame: Family room: Windows: ------- Fly Screen: ------- Joinery / Cupboards: -------- Weather seals External Door & Frame: -------- Kitchen: Joinery / Cupboards: Study: Flyscreen: Splash back: Owner Builder defects Report Page 4

INSPECT DIRECT Ph: 1300 133363 Fly Screen: Joinery / Cupboards: ----------- Weather seals External Door & Frame: ------- Bedroom No.1: Fly Screen: Wardrobe & Inserts: Weather seals External Door & Frame: -------- Bedroom No.2: Fly Screen: Wardrobe & Inserts: Weather seals External Door & Frame: --------- Bedroom No.3: Fly Screen: Wardrobe & Inserts: Weather seals External Door & Frame: --------- Bedroom No.4: Fly Screen: Wardrobe & Inserts: Weather seals External Door & Frame: -------- Toilet / Powder Room: Heating: ------ Cooling: -------- Window: Flyscreen: Vanity: Splash back: Exhaust Fan: Basin WC (Seat & Pan & Cistern): Taps: Mirror: Bathroom No.1: Owner Builder defects Report Page 5

Ph: 1300 133363 Window: Joinery: Exhaust Fan: Shower: WC (Seat & Pan & Cistern): Mirror: INSPECT DIRECT Flyscreen: Splash back: Vanity: Bath: Taps: Basin: Bathroom No.2 - Ensuite: Window: Flyscreen: Joinery: Splash back: Exhaust Fan: Vanity: Shower: Bath: ------- WC (Seat & Pan & Cistern): Taps: Mirror: Basin: Laundry: Heating: ----------- Cooling: ------------ Window: Flyscreen: Joinery: Splash back: Exhaust Fan: ---------- Laundry Trough / Trough cabinet: Washing Machine Taps: Taps: Broom Closet: Weather seals external Door & Frame: Garage No.1: Wall Structure: Roof Structure: Door Remote Controller: Walls / Ceiling: Windows: ------------ Roof Cladding: Joinery:----------- Side / Rear Access Door/s: Roller / Panel Lift Door/s: Brick Piers: Veranda #1: Electrical Power & Lights: --------- Base Wall / Plinth Boards: --------- Ceiling / Roof Structure: Metal Posts: Doors: --------- Windows:-------- Decorative Moulds:-------- Gutters: C1 Roof Coverings: Down Pipes: Flashings / Cappings: Owner Builder defects Report Page 6

INSPECT DIRECT Ph: 1300 133363 REPORT ON DOMESTIC BUILDING WORK UNDER SECTION 137B OF THE BUILDING ACT 1993 (OWNER-BUILDER CONSTRUCTION): Please refer to the fault / maintenance number adjacent the item for identification. The fault / maintenance number will have a letter in front of it such as an M refer to the fault / maintenance identification legend to identify the letter placed in front of each fault / maintenance number. Use of the fault / maintenance numbers is achieved by corresponding the numbering with the individually numbered faults / maintenance item identified within the back section of this report. Notes: 1.0 Timbers that are exposed to the weather may be prone to premature degradation vigilant monitoring required. 2.0 Timbers that are close to or in the ground may be prone to premature degradation vigilant monitoring required. 3.0 Paths & gardens surrounding the property to be monitored for water retention during & following rain periods. 4.0 Gutters & roof surface to be maintained cleaned to prevent build up of debris & potential gutter / down pipe / stormwater system blockage 5.0 Site drainage to be monitored water retained along the base of walls of the building or close to the base of the walls of the building may become problematic. 6.0 Extent of veranda & Veranda proximity to boundary to be checked with building permit drawings / Documents. 7.0 Ensure that insulation is kept away from down lights in accordance with manufacturers installation instructions. List of defects in the building/s:* M1: - Concrete path along the north side of the house has subsided slightly along the base of the walls of the house resulting in the concrete path being relatively flat in parts Monitor during & following rain periods for water retention. M2: - Weep holes located at the base of the walls of the building are noted to be at paving & garden bed level. Owner Builder defects Report Page 7

Ph: 1300 133363 INSPECT DIRECT Sub Floor: Stumps / Piers: ------------ Services: ----------- Framing: ------------ Accessibility:----------- Floor: -------------- Sub floor Walls: ------------- Sub floor Ground: -------------- Moisture: ----------- Roof Space: Structure: Roof Cladding: Roof Services: Roof Ventilation: - Not Ventilated Sarking: Areas of the building/s inaccessible at the time of inspection: Insulation: Accessibility: P - Parts of roof space not accessible. Testing may not have been exhaustive Down Lights: - Monitor 1.0 Parts of roof space not accessible. Testing may not have been exhaustive. 2.0 Furniture within rooms obstructing vision in parts. Testing may not have been exhaustive. 3.0 Items stored within wardrobes obstructing vision in parts. Testing may not have been exhaustive. 4.0 Items stored within garage obstructing vision in parts. Testing may not have been exhaustive. Documents Sited / Viewed at time of inspection: 1. Architectural Drawings, plans, & Specifications: - Viewed at the time of the inspection. 2. Engineering Drawings, Plans, & Specifications: - Viewed at the time of the inspection. 3. Building Permit: - Viewed at the time of the inspection. 4. Certificate of occupancy / final inspection certificate: - Viewed at the time of the inspection. Incomplete Works: C1: - Rear section of veranda does not have a gutter. Second Hand Material: No - Second Hand Material not used during construction of this building: Owner Builder defects Report Page 8

Ph: 1300 133363 INSPECT DIRECT Description of Second Hand Material Used: General Term & Conditions: This report is provided, pursuant to the following Acts and their subordinate legislation as they apply in their respective states: The Building Act 1993 (VIC) The Home Building Act 1989 (NSW) The Home Building Contracts Act 1991 (WA) Selling a house built or renovated by an owner builder Before entering into a contract to sell a house which has been built or renovated by a person other than a registered building practitioner, where the works have been completed for less than 6 years (7yrs NSW) prior to the date of sale, the owner builder must: 1. Obtain this Inspection Report. It must be provided to the intended purchaser by the owner builder. The Inspection Report must not be older than six (6) months old at the date of the contract. 2. Send to an approved insurer: a completed Application for Owner Builder s Indemnity Insurance, a copy of this Inspection Report, the appropriate fee confirm the fee with the insurer. If all items are in order, the insurer will send you the necessary certificate or schedule of insurance. 3. Provide evidence of the insurance to the intended purchaser. 4. Ensure your contract contains the warranties listed in the shaded section below. After the contract has been signed, the owner builder must send a copy of the contract to the insurer. If a contract of sale has been entered into in contravention of the legislation, the contract is not void by reason only of the contravention but is voidable at the option of the purchaser at any time before the completion of the contract. The insurance is applicable to structural works done by the owner builder which have been completed for less than 6 years (7yrs NSW) prior to the date of sale. The insurance ceases for structural works when that 6 year (7yrs NSW) period expires. *The insurance ceases in 2 years for nonstructural works. The insurance only covers defects caused by the owner builder and does not cover any defects identified in the report. Please note that where the owner builder has renovated or extended the home, the insurance only relates to those works. The balance of the house is not covered by this insurance at all. Defects identified in this Report are those caused by bad workmanship or movement of foundations. This report does not necessarily refer to routine maintenance items (e.g. hair-line plaster cracks or jamming doors and windows) which are caused by normal shrinkage providing the workmanship was not defective. Serious defects are defects which seriously affect the structural integrity of the property or require the substantial replacement of plumbing or electrical services. In the case of cracking, serious defects denote severe cracking as defined by Category 4 Appendix A Australian Standard AS 2870.1 1988. Unless otherwise stated: no soil or other material has been excavated or removed, no plants or trees have been removed no samples have been taken or tested, no fixtures, fittings, cladding or lining materials have been removed, building services have not been tested, no items of furniture or chattels have been moved, the roof has not been water tested, no enquiries of Drainage, Sewerage or Water Authorities have been made, no plans, specifications or other contract documents have been sighted for the purpose of inspecting the dwelling house and providing this report, no special investigation of insect attack (e.g. borer, termite, etc.) has been made and any reference to this has been based on casual inspection. This report is incomplete unless the required local government building approval and inspection summary details are attached. Warranties for the purposes of houses sold by owner builders The following warranties must be part of every contract of sale of property by an owner builder where insurance applies*. a) The vendor warrants that all domestic building work carried out in relation to the construction by or on behalf of the vendor of the home was carried out in a proper and workmanlike manner; and * Not applicable in some states Owner Builder defects Report Page 9

INSPECT DIRECT Ph: 1300 133363 b) The vendor warrants that all materials used in the domestic building work were good and suitable for the purpose for which they were used and that, unless otherwise stated in the contract, those materials were new; and The vendor warrants that the domestic building work was carried out in accordance with all laws and legal requirements, including, without limiting the generality of the warranty, the Building Act and the regulations. Inspect Direct Pty Ltd Terms & Conditions: The Report has been prepared by the registered inspector (named within), with reasonable care, subject however as follows; 1) This Report is not a Guarantee but is provided in accordance with the relevant State Act. 2) The Report is based on the condition of the property and the prevailing structural, soil and weather conditions at the time of the inspection. 3) Except where specifically stated otherwise, the Report is based on a visual inspection of such parts of the premises as the Report states the inspector has been able to have reasonable access to without the removal of any furniture, fittings be they fixed or other wise cladding, or lining materials, plants or soil. The Report will not disclose latent defects or defects which may be apparent in weather conditions which differ from those at the time of the inspection. 4) The Report will not disclose defects which have not yet arisen. Changes in usage can cause defects and any abuse of the premises is likely to do so. 5) The Report may not cover defects of a minor nature, such as hair-line plaster cracks, jamming doors, windows or catches and similar minor faults. * Reports listing defects in the building/s to include, but are not restricted to, conditions of the following building elements: Site drainage Footings Subfloor Frame External walls Internal walls and ceilings Floor and wall tiling External roof Internal roof conditions Built-in fittings/joinery Doors/windows Fireplaces/solid fuel heaters Plumbing and drainage Fixed appliances Flyscreens Driveways, paving, retaining walls, fencing, garages, carports, workshops, swimming pools or spas where constructed as part of the major domestic building contract. Certificates attached to this report: A copy of any building permits issued, any occupancy permits or certificates of final inspection issued (as applicable), must be attached to this report. Building Permit Attached: Yes / No Occupancy Permit attached: Yes / No Final Inspection Certificate attached: Yes / No Electrical or Plumbing Certificates: Yes / No Copy of reduced Drawings: Yes / No Owner Builder defects Report Page 10