An Experimental Investigation on BioMedical Waste Concrete

Similar documents
Biomedical Waste Ash in Concrete: An Experimental Investigation

Study On Properties Of High Strength Silica Fume Concrete Withpolypropylene Fibre

COST EFFECTIVE COMPOSITE CONCRETE USING LIME SLUDGE, FLY ASH AND QUARRY SAND

AN EXPERIMENTAL INVESTIGATION ON CONCRETE BY PARTIAL REPLACEMENT OF COPPER SLAG WITH FINE AGGREGATE AND CERAMIC WASTE WITH COARSE AGGREGATE

Replacement of Fine Aggregate in Concrete with Municipal Solid Waste Bottom Ash from Incinerator

Study of High Performance Concrete with Silica Fume and Glass Fibre

High Strength Concrete With Pond-Ash as Partially Replaced by Fine Aggregate and Fine Fly-Ash, Alccofine as Cement

Effect of Copper Slag and Basalt Fibers on Various Properties of Concrete

CONCRETE USING RECYCLED AGGREGATES

A STUDY ON HYBRID FIBRE REINFORCED SELF COMPACTING CONCRETE

The durability of normal strength concrete: an experimental study

A STUDY ON MECHANICAL PROPERTIES OFCONCRETE WITH CONCRETE GRADE VARIATION IN TENSION AND COMPRESSION ZONES

World Journal of Engineering Research and Technology WJERT

Experimental Study on Glass Fibre Reinforced Steel Slag Concrete with Fly Ash

STRENGTH AND RHEOLOGICAL PROPERTIES OF FIBER REINFORCED SELF COMPACTING CONCRETE WITH ALCCOFINE

A Study on Strength of Concrete by Partial Replacement of Cement with Metakaolin and Fine Aggregate with Stone Dust

Properties of Fly Ash Based Coconut Fiber Composite

STRENGTH CHARACTERISTICS OF CONCRETE WITH WASHED BOTTOM ASH PARTIALLY REPLACED FOR FINE AGGREGATE

Experimental Investigation On Concrete With Partial Replacement Of Blast Furnace Slag And Ceramics Tiles As Coarse Aggregate.

Studies on properties of concrete with fluorescent waste glass powder

STUDY ON AXIAL STRESS-STRAIN RELATION AND POISSON S RATIO EFFECT ON COCONUT SHELL CONCRETE

Experimental Investigation of Recycled Plastic Aggregate in Concrete

Durability Studies of Sugarcane Bagasse Ash Concrete

Impact of Fly Ash and Silpozz as Alternative Cementitious Material in Crusher Dust Concrete [1]

CHAPTER 6 POLYPROPYLENE FIBRE REINFORCED GEOPOLYMER CONCRETE COMPOSITES

STRENGTH PARAMETERS OF CONCRETE CONTAINING RECYCLED AGGREGATE

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 1, No 3, 2010

A H M 531 C The Civil Engineering Center

Comparative Study on the Strength and Durability Properties of M 50 Grade Self Compacting Concrete with Micro Concrete

STUDY ON MECHANICAL PROPERTIES OF CONCRETE USING SILICA FUME AND QUARTZ SAND AS REPLACEMENTS

To Study the Flexural, Tensile and Compressive Strength of Reinforced Concrete by Adding Glass & Steel Fibers in Different Proportions

South Asian Journal of Engineering and Technology Vol.3, No.7 (2017)

JOURNAL OF INTERNATIONAL ACADEMIC RESEARCH FOR MULTIDISCIPLINARY Impact Factor 1.393, ISSN: , Volume 2, Issue 2, March 2014

Experimental Study on Partial Replacement of Cement by Hyposludge in Concrete

AN EXPERIMENTAL STUDY ON GLASS FIBRE REINFORCED CONCRETE

18. Durability studies carried out in the present investigation in. ordinary grade and standard concrete, through acid attack test

EFFECT OF THE LIME CONTENT IN MARBLE POWDER FOR PRODUCING HIGH STRENGTH CONCRETE

Effect of Plastic and Fibers in No-Fine Concrete on Mechanical and Durability Properties

Study On Recycled Waste Glass Fine Aggregate Concrete

A STUDIES ON BEHAVIOUR OF GEOPOLYMER CONCRETE

Experimental Investigation on Natural Fiber Concrete with Palm Oil Tree Fiber

A STUDY ON CRUSHED SAND AS AN ALTERNATIVE FOR NATURAL SAND IN HIGH PERFORMANCE CONCRETE

DREDGED OFFSHORE SAND AS A REPLACEMENT FOR FINE AGGREGATE IN CONCRETE

STUDY ON CONCRETE REPLACED WITH CRUSHED CONCRETE FINE AGGREGATE

USE OF JHAMA BRICK DUST AS AN ALTERNATIVE MATERIAL FOR FINE AGGREGATE IN CONCRETE

Study of Properties of Self Compacting Concrete with Micro Steel Fibers and Alccofine

EFFECT ON MECHANICAL PROPERTIES OF CONCRETE USING NYLON FIBERS

Strength properties of concrete with partial replacement of sand by bottom ash

January - March JCPS Volume 10 Issue 1

AN EXPERIMENTAL STUDY ON PROPERTIES OF THE CONCRETE FOR REPLACEMENT OF SAND BY STONE WASTE FOR DIFFERENT TYPES OF CEMENT WITH CHEMICAL ADMIXTURE

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.5, pp ,

Experimental Investigation on Strength Parameters for Composite Concrete by Using Waste Glass Powder, Flyash Aggregate and M-Sand

Performance of Concrete by replacing Coarse Aggregate and Fine Aggregate with Blast Furnace Slag and Crusher Dust

An Experimental Study on Partial Replacement of Cement by Ggbs and Natural Sand by Quarry Sand in Concrete

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October ISSN

ISSN: [Sasikala* et al., 6(4): April, 2017] Impact Factor: 4.116

Puducherry , India. Puducherry , India.

EXPERIMENTAL INVESTIGATION ON PARTIAL REPLACEMENT OF FINE AGGREGATE WITH SABBATH (CUDDAPAH STONE) STONE

CHAPTER 4 METHODOLOGY

Flexural Behaviour of Reinforced Concrete Beams Replacing GGBS as Cement and Slag Sand as Fine Aggregate

Study on the Utilization of Paper Mill Sludge as Partial Cement Replacement in Concrete

STUDIES ON THE EFFECTS OF SEAWATER ON COMPRESSIVE STRENGTH OF CONCRETE CUBE

Research Article The Effect of Accelerators and Mix Constituents on the High Early Strength Concrete Properties

Partial Replacement of Coarse Aggregate by Waste Ceramic Tile in Concrete

Studies on the Mechanical Properties of Glass Fiber Reinforced Concrete with Using Recycled Aggregate

Mechanical properties of high strength mortar for repair works

STUDY ON STRENGTH PROPERTIES OF FIBRE REINFORCED CONCRETE BY PARTIAL REPLACEMENT OF SAND BY COPPER SLAG

The Influence of Metakaolin on the Modulus of Elasticity of Concrete

STUDY OF STEEL SCRAP REINFORCED CONCRETE WITH PARTIAL REPLACEMENT OF CEMENT WITH BAGASSE ASH

Effect of Copper Slag on Steel Fiber Reinforced Concrete and Conventional Concrete

Investigation of Natural Hybrid Fibre Reinforced Beams with Nano Concrete under Cyclic Loading

EXPERIMENTAL INVESTIGATION ON STRENGTH AND DURABILITY CHARACTERISTICS OF HIGH PERFORMANCE CONCRETE USING GGBS AND MSAND

THE EFFECT OF GGBS ON THE STRENGTH AND CHLORIDE PENETRATION OF CONCRETE

BEHAVIOUR OF M 25 GRADE CONVENTIONAL CONCRETE AND FLY ASH BLENDED CONCRETE IN ACIDIC ENVIRONMENT

ISSN (PRINT): , (ONLINE): , VOLUME-5, ISSUE-5,

V. Naga Kalyani 1 1 PG Student, K. Hari Krishna 2 2. A. Naga Sai 3 3.

Performance of High Strength High Performance Steel Fiber Reinforced Concrete for use in Seismic Resistant Structures

Experimental Study on Rice Husk Ash in Concrete by Partial Replacement

Triangular Polyestor Fibers as Secondary Reinforcement in Concrete for Flexure / Split Tensile Strength

Experimental Study of Flexure and Impact on Ferrocement Slabs

EFFECT OF SUPER ABSORBANT POLYMER IN CONCRETE

DURABILITY STUDIES ON POLYETHYLENE TEREPHTHALATE (PET) FIBRE REINFORCED CONCRETE

International Journal of Engineering and Techniques - Volume 4 Issue 3, May June 2018

A Study on Strength Properties of Hybrid Fiber Reinforced Self Compacting Concrete

Strength Properties of Concrete Using Crumb Rubber with Partial Replacement of Fine Aggregate

An Experimental Study on the Behaviour of Concrete by Partial Replacement of Cement with GGBS K Sravani Roopa 1 EV Raghava Rao 2

Mechanical Properties of Glass Fiber Reinforced Concrete

Experimental Study on Partial Replacement of cement by Fly Ash with Glass Fiber Reinforcement

CHAPTER 4 GEOPOLYMER CONCRETE COMPOSITES

JAZAN UNIVERSITY. CIVIL ENGINEERING DEPARTMENT Equipments and Devices of the Concrete Laboratory

Technology, Vijayawada, India 2 Assistant professor, Department of Civil engineering College, Vikas Group of Institutions, Vijayawada, India

Investigation on Durability Properties of Concrete Using Manufactured Sand and Admixtures

EXPERIMENTAL INVESTIGATION ON THE PROPERTIES OF CONCRETE WITH PARTIAL REPLACEMENT OF SAND BY SCALE.

Experimental Studies on the Effect of Ceramic fine aggregate on the Strength properties of Concrete

Performance of Concrete with Granite Slab Waste as Coarse Aggregate at Elevated Temperatures

STRENGTH AND DURABILITY PROPERTIES OF HIGH PERFORMANCE CONCRETE INCORPORATING SILICA FUME

Study on Mechanical properties of Geo Polymer Concrete Using M-Sand and Glass Fibers

Experimental Study on Concrete by Partial Replacement of Fine Aggregate with Stone Dust and Cement by Glass Powder for M-30 Grades of Concrete

Use of crushed rock powder as replacement of fine aggregate in mortar and concrete

Effect of silica fume on the resistance to chloride ion penetration in high performance concrete

Transcription:

SSRG Journal of Civil Engineering- (ICRTCETM-217) - Special Issue - April 217 Conference in Civil Engineering, Technology and Management (ICRTCETM-217) An Experimental Investigation on BioMedical Waste K.Malavan R.Manju PG Student, M.E.Structural Engineering, Kumaraguru College of Technology, Coimbatore, Tamil Nadu, India Email: malavan.911993@rediffmail.com Assistant Professor, Department of Civil Engg., Kumaraguru College of Technology, Coimbatore, Tamil Nadu, India Email: manjustructure@gmail.com Abstract Bio-medical waste disposal is one of the major problem in India. These wastes are generated from hospitals, Medical research Centre and other medical sources are causing a real problem for living nature and human world. Some studies disclosed the range of utilization of Bio-medical waste as a partial replacement to sand in concrete. This paper reports the result of an experimental program carried out to study the effects of use of biomedical waste in concrete as partial replacement of sand. Keywords Bio-Medical Waste, Compressive strength, Split tensile strength, Density, Flexural strength of beam. I. INTRODUCTION Bio-medical waste is the waste liquids, solids, sharps and laboratory waste that are potentially infectious and dangerous. It is a waste from biological sources or is used in the diagnosis, prevention or treatment of disease. Common producers of BMW include health clinics, hospitals, medical research laboratories, physicians, dentists and veterinarians and home health care. According to ministry of Environment and Forest about 4,5,72 kg/day biomedical waste generated in India out of which around 72% is disposed off, more than 28% is left unattended[1]. Most common process of disposal of biomedical waste is incineration in specifically made for it. The ash produced in these incinerators are dispose as landfills. For the landfills large land area is required. This land requirements can be reduced by partial replacement of sand in concrete. On other hand the protection of environment by reducing the consumption of natural river sand. In India, at present there are 17 common BMW treatment facilities in which 14 incinerators plants are present [1]. Velocity and durability studies such as Rapid chloride penetration test, Permeability test. A. Cement Ordinary Portland cement were used satisfying all the requirements as per IS 12269:1993, was used in making the concrete. The physical properties of cement were specific gravity - 3.15, Specific area 319 m2/kg. B. Fine Aggregate Sand i.e., fine aggregate obtained locally from nearest river passing through 4.75 IS sieve having fineness modulus - 2.6 & confirming to zone-iii as per IS: 383-197.Its specific gravity was 2.58 respectively. C. Coarse Aggregate Blue metal i.e., Coarse aggregate obtained locally. 2 mm Nominal size Graded aggregate having fineness modulus 3.92 & confirming to IS:383197 specification. The physical properties of CA were specific gravity 2.78, Water absorption.9%. D. Bio-Medical Waste Biomedical waste ash which was used throughout this experiment was collected from Palladam, Coimbatore incinerator plant, which was grey in colour and lighter in weight and coarser than cement. II. MATERIALS AND METHODS For casting of concrete generally used raw materials are Cement, Fine aggregate (River sand), Coarse aggregate and Water were used. Experimental investigation was carried on Bio-Medical Waste to investigate the effect on properties of concrete on the partial replacement of fine aggregate in concrete on Compressive strength, Split tensile strength, Flexural strength, Density, Young s modulus, Ultrasonic Pulse FIG 1: BIO-MEDICAL WASTE ASH Sense Research - 8352 Group 2261 369

SSRG Journal of Civil Engineering(ICRTCETM-217) - Special Issue(ICRTCETM-217) - April 217 Conference in Civil Engineering, Technology and Management E. The concrete mix design was done in accordance with IS 1262: 29. The cement content used in the mix design was taken as 45 kg/cu.m which satisfies minimum requirement of 34 kg/cu.m in order to avoid the balling affect. III. RESULT AND DISCUSSION The result of experimental investigation carried out to determine Density, Compressive strength, Split tensile strength, Flexural strength, are discussed here in after. A. Density The density of concrete is a measurement of concrete's solidity. The process of mixing and addition of material in concrete can be modified to form a lower or higher density of concrete end product. It is clearly evident from Fig 1 that the density of concrete decreased with increase in replacement level which may be due to Bio-Medical Waste being lighter than sand. FIGURE 1: DENSITY OF CONCRETE B. Compressive Strength Compressive strength is the Max. Compressive stress under a gradually applied load a given solid material can sustain without fracture. Compressive strength is calculated by dividing the maximum load by the cross sectional area of a specimen in a compression test. The test results are tabulated in Table I. It is clearly observed that the Compressive strength of concrete made by using BMW with replacement of sand by weight at 7 days and 28 days are decreased with increase in the replacement level as shown in Figure 2 TABLE I COMPRESSIVE STRENGTH OF CONCRETE Replacement level of sand Compressive Compressive Designation with biostrength @ 7 strength @ of medical days 28 days waste (%) 29.65 45.3 BMW 1 1 27.78 37.11 BMW 2 2 25.17 34.92 BMW 3 3 19.14 31.1 BMW 4 4 15.17 25.64 Sense Research Group - 8352 2 37227

SSRG Journal of Civil Engineering(ICRTCETM-217) - Special Issue(ICRTCETM-217) - April 217 Conference in Civil Engineering, Technology and Management FIGURE 2: COMPRESSIVE STRENGTH OF CONCRETE C. Split tensile strength Splitting tension test is the test carried out by placing a cylindrical specimen horizontally between the loading surface of a compression testing machine and the load is applied gradually till the failure of the cylinder, along the vertical diameter. The test results are tabulated in Table II. From this experiment, it is clearly observed that the Split tensile strength of concrete made by using BMW with replacement of sand by weight at 7 days and 28 days are decreased with increase in the replacement level as shown in Figure 3. TABLE II SPLIT TENSILE STRENGTH OF CONCRETE Designation of Replacement level of sand with biomedical waste (%) Split tensile strength @ 7 days Split tensile strength @ 28 days 2.19 4.35 BMW 1 1 1.69 3.61 BMW 2 2 1.49 3.23 BMW 3 3 1.35 2.51 BMW 4 4 1.14 1.96 FIGURE 3: SPLIT TENSILE STRENGTH OF CONCRETE - 8352Group Sense Research 3 228371

Conference Journal in Civil Engineering, Technology- and Management (ICRTCETM-217) SSRG of Civil Engineering(ICRTCETM-217) Special Issue - April 217 TABLE III FLEXURAL STRENGTH OF CONCRETE D. Flexural strength Flexural strength test is carried out on the prism specimen of size 15 x 1 x 1mm. Prism is placed horizontally and two point loading is applied to it as per IS 516 1959. From this experiment, it is evident that the flexural strength of concrete made by using BMW with replacement of sand by weight at 7 days and 28 days are decreased with replacement level as shown in Figure 4 and Table III. Replacement level of sand with bio-medical waste (%) Flexural strength @ 28 days 4.13 BMW 1 1 4.9 BMW 2 2 3.81 BMW 3 3 3.28 BMW 4 4 3.18 FIGURE 4: FLEXURAL STRENGTH OF CONCRETE E. Ultrasonic Pulse Velocity The Ultrasonic Pulse Velocity test results of all the mixes are given in Table IV. The maximum velocity of 3.7 km/s was observed for the control mix. According to IS 13311 (Part 2) : 1992, concrete are categorised as excellence, good, medium and doubtful for 4.5km/s and higher, 3.5 4.5 km/s, 3 3.5 km/s, and less than 3 km/s respectively. It was concluded from the result that due to the addition of BMW, velocity get decreased. This was due to the presence of voids when compared to the control mix. TABLE IV ULTRASONIC PULSE VELOCITY TEST Pulse Velocity (km/sec) quality 3.7 Good BMW 1 3.51 Good BMW 2 3.34 Medium BMW 3 3.24 Medium BMW 4 3.14 Medium Sense- 8352 Research Group 229 4 372

SSRG Journal of Civil Engineering- (ICRTCETM-217) - Special Issue - April 217 Conference in Civil Engineering, Technology and Management (ICRTCETM-217) F. Young s modulus The young s modulus test was conducted on cylindrical specimen as per IS 2854: 199. results of all the mixes are given in Table IV. The maximum velocity of 3.7 km/s was observed for the control mix TABLE VII PERMEABILITY TEST ON CONCRETE From this experiment, it is evident that the young s modulus of concrete made by using BMW with replacement of sand at 28 days are decreased with replacement level as shown in Table V and also compared with the theoretical value (5 fck). TABLE V YOUNG S MODULUS OF CONCRETE Modulus of Elasticity Ec concrete Experimental value Theoretical Value (5 fck) 32666.67 33652.64 BMW 1 28667.67 3458.99 BMW 2 27647.6 29546.57 BMW 3 25181.82 27883.69 BMW 4 23766.67 25317.98 Depth of penetration (mm) 51 BMW 1 74 BMW 2 12 BMW 3 138 BMW 4 189 I. Flexural behaviour of BMW beam The beam of size 15mm x 15mm x 18mm were casted for control mix and optimized BMW mix (1% replacement). After 28 days of curing, the beams were tested as simply supported two point loading beam. Deflection was noted under the load point and also in the center of the beam. The results are tabulated in Table VIII. TABLE VII DEFLECTION AT L/2 AND L/3 DISTANCE Deflection at L/2 distance G. Rapid Chloride Penetration Test The Rapid Chloride Penetration Test (RCPT) was conducted on cylindrical specimen of size 1mm diameter and 5 mm height. NaCl and NaOH solution on left and right hand side of the test cell respectively, 6 volt potential was applied for 6 hours. From this experiment, it is evident that the chloride permeability on concrete is very low for control mix and upto 3% replacement and for 4% replacement the value was Low. It shows the concrete was least permeable. The test results are tabulated in Table VI. TABLE VI RAPID CHLORIDE PENETRATION TEST Deflection at L/3 distance Load BMW 1% BMW 1% 1.13.11.7.11 2.26.24.15.24 3.38.4.24.43 4.47.59.32.6 5.58.77.43.77 6.79.91.64.9 7.93 1.13.75 1.1 8 1.18 1.47.99 1.4 9 1.4 1.76 1.2 1.64 1 1.65 2.5 1.43 1.9 11 1.88 2.38 1.66 2.19 Charge passed (Coulombs) Chloride permeability 12 2.13 2.6 1.88 2.38 511 13 2.4 2.87 22.9 2.62 BMW 1 475 14 2.71 3.13 2.42 2.85 BMW 2 583 15 2.94 3.48 2.61 3.15 BMW 3 758 16 3.12 3.75 2.79 3.38 BMW 4 1838 Low 17 3.4 4.1 3.1 3.62 H. Permeability Test The Water Permeability was conducted on cube specimen of size 15mm. Water is applied at a constant pressure of 1kg/sq.cm as per IS 385: 1965. 18 3.64 4.25 3.2 3.85 19 3.93 4.61 3.49 4.11 2 4.17 4.94 3.74 4.46 From this experiment, it shows the depth of penetration value get increased as compare to control mix.it is evident that the voids get increased as the replacement level get increased. The results are shown in Table VII. 21 4.51 5.46 4.1 4.9 22 4.84 5.91 4.3 5.24 23 5.3 6.45 4.7 5.76 24 6.5 7.34 5.23 6.56 25 7.5 8.45 5.73 7.35 Sense Research - 8352Group 23 5 373

Conference in Civil Engineering, Technology and Management SSRG Journal of Civil Engineering(ICRTCETM-217) - Special Issue(ICRTCETM-217) - April 217 FIGURE 5: LOAD DEFLECTION CURVE AT L/2 DISTANCE FIGURE 6: LOAD DEFLECTION CURVE AT L/3 DISTANCE The Ultimate load carrying capacity of control mix and BMW 1% concrete beams were 294 & 299 respectively. IV. CONCLUSION On the basis of the results obtained during the experimental investigation, following conclusions are drawn (i) It is observed that density of concrete decreased marginally with the increase in the replacement level of BMW. (ii) Compressive strength, Split tensile strength, Flexural strength of concrete made using BMW is lesser than that of conventional concrete. (iii) It is observed that UPV test for control mix and 1% replacement concrete is termed as good quality concrete. (iv) RCPT result show that the chloride penetration is very low upto 3% replacement level. (v) The permeability of concrete get increased marginally with increase in replacement level. (vi) After comparing all the experimental test results, 1% replacement level is taken as the optimized percentage. Sense Research - 8352 Group 231 374 6

SSRG Civil in Engineering(ICRTCETM-217) - Special Issue - April 217 Conference onjournal Recent of Civil Engineering, Technology and Management (ICRTCETM-217) (vii) It is evident that load-deflection curve of control mix is similar to that of the optimized percentage. (viii) The ultimate load carrying capacity of control beam is much more similar to that of the optimized percentage. REFERENCES [1] Al-Rawas AA, Hago AW, Taha R and Al-Kharousi K, Use of incinerator ash as a replacement for cement and sand in cement mortars. Volume 4, Issue 9, s 1261 1266, 25. [2] Altin S, Altin A, Elevli B and Cerit O, Determination of hospital waste composition and disposal methods: a case study. Polish Journal of Environmental Studies Vol. 12, No., 251-255,23. [3] Azni I and Katayon S, Characteristics of slag produced from incinerated hospital waste. Volume 93, Issue 2, s 21 28, 22. [4] Azni I, Katayon S, Ratnasamy M and Johari MMNM, Stabilization and utilization of hospital waste as road and asphalt aggregate. Volume 7, Issue 1, pp 33-37, 25. [5] Clozel-Leloup B, Bodenan F and Piantone P (1999). Bottom ash from municipal solid waste incineration: mineralogy and distribution of metals, in: Mehu J, Keck G, Navarro A (ed) STAB & ENV 99. [6] Cobo M, Galvez A, Conesa JA and de Correa, Characterization of fly ash from a hazardous waste incinerator in Medellin, Colombia, Volume 168, Issues 2 3, s 1223 1232, 29. [7] Filipponi P, Polettini A, Pomi R and Sirini P, Physical and mechanical properties of cement based products containing incineration bottom ash., Volume 23, Issue 2, s 145 156,23. [8] Genazzini C, Giaccio G, Ronco A and Zerbino R, Cement-based materials as containment systems for ash from hospital waste incineration., Volume 25, Issue 6, s 649 654, 25. [9] Gidarakos E, Petrantonaki M, Anastasiadou K and Schramm KW, Characterization and hazard evaluation of bottom ash produced from incinerated hospital waste. Volume 172, Issues 2 3, s 935 942, 29. [1] IS 12269:1993, Specification for 53 grade Ordinary Portland cement, Bureau of Indian Specifications, New Delhi, India. [11] IS 383-197, Specifications for Coarse and Fine aggregates from natural sources for concrete. Sense Research - 8352 Group 232 375 7