HIGH MAST CAMERA POLE ASSEMBLY GENERAL

Similar documents
SECTION PIER 94 HIGH MAST LIGHTING. A. Replace existing high mast lighting poles M and N located at Pier 94.

SPECIAL SPECIFICATION 1924 Neighborhood Friendly High Mast Illumination System

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

JAMISON SOUND DOOR SPECIFICATIONS VERTICAL SLIDING SOUND REDUCTION DOOR - STC 53 POWERED OPERATION

SECTION FLAGPOLES

SECTION ALUMINUM GATES

WALL MOUNTED ARTICULATING JIB CRANE

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE

Item 442 Metal for Structures

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION CHAIN LINK FENCES AND GATES (PARK)

05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES

CEILING MOUNTED ARTICULATING JIB CRANE

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

FF200, FOUR-FOLD DOORS CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS.

CITY OF FARGO SPECIFICATIONS SIGNING

This guide can be used to prepare a specification for incorporating wall bracket jib cranes into a competitively bid construction project.

Attachment A-Flagpole(s) Specifications

A. Product Data shall be provided for each type of product indicated.

SECTION ALUMINUM HANDRAIL SYSTEMS

F-SERIES: FF XT SPECIFICATIONS Exterior Swinging Four-Fold Door Systems

CITY OF FARGO SPECIFICATIONS SIGNING

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF SECTIONAL STEEL HIGH MAST LIGHTING POLES

Aluminum Perforated Rolling Door

F-SERIES: F SPECIFICATIONS Four-Fold Door Systems

L-SERIES: LTH3900 SPECIFICATIONS Stainless Steel Hollow Metal Sliding Fire Door System

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

SECTION CHAIN LINK FENCES

Special Specification 6292 Radar Vehicle Detection System for Signalized Intersection Control

SECTION CHAIN LINK FENCING

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR LOW-TENSION CABLE BARRIER. OPR:CT 1 of 5 APPR:JAR:DBP: FHWA:APPR:

N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System

SECTION MOTOR CONTROL CENTER

WALL CANTILEVER WORK STATION JIB CRANE

POLE: ANCHOR BASE, ALUMINUM, TAPERED TUBULAR SHAFT

SECTION 1043 FENCE MATERIAL

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR SPUN CONCRETE POLE AND DRILLED SHAFT FOUNDATION

SECTION MECHANICAL SPECIFICATION GRIT COLLECTION EQUIPMENT

OPTIONS ARE LISTED IN RED, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS.

SECTION METAL ATHLETIC LOCKERS

SECTION ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED

SECTION TIMBER FLOATS

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

ITEM 442 METAL FOR STRUCTURES

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

ITEM 555 CHAIN LINK FENCING

SECTION 716 SIGN MATERIALS SCOPE

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

SECTION METAL EQUIPMENT LOCKERS

Rapid Axial Load Testing of Drilled Shafts

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

SECTION ORNAMENTAL ALUMINUM FENCING

SPECIFICATION: STAINLESS STEEL GATES

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION 552 HELICAL ANCHORS AND HELICAL PILES

2000-SG STAINLESS STEEL SLIDE GATES

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION

MATERIAL SPECIFICATION FOR STEEL POLES, BASE MOUNTED

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION CHAIN LINK FENCING

Bi-Directional Static Load Testing of Drilled Shafts

Bi-Directional Static Load Testing of Drilled Shafts

SECTION SECTIONAL OVERHEAD DOORS

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

OVERSHOT GATE TECHNICAL DATA SHEET

NOTE TO SPECIFYING ARCHITECT REGARDING SECTION CONTOUR CURTAIN AND MOTOR

SPECIFICATIONS - DETAILED PROVISIONS Section Progressing Cavity Pump C O N T E N T S

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION METAL ATHLETIC LOCKERS

CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS DOCUMENT 00085B ADDENDUM ADDENDUM NO. 1

SECTION SOLID PHENOLIC PLASTIC TOILET PARTITIONS

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

AUTOMATIC VERTICALLY RETRACTABLE Skyfold Mirage ACOUSTIC INTERIOR GLASS WALL Section Page 1 October 2017

MATERIAL SPECIFICATION FOR LUMINAIRE RAISING AND LOWERING EQUIPMENT

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

Colorado River Aqueduct Pumping Plants 230 kv Disconnect Switches Replacement

SECTION SECTIONAL OVERHEAD DOORS

American Metal Specialties, Inc.

LTH3700, HOLLOW METAL SLIDING FIRE DOOR

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

SECTION SLUICE GATES

SECTION FLAGPOLES. 1.1 SUMMARY A. Section Includes: 1. Fixed high dimensional, ground set, uniform conical taper, seamless tube flag pole.

ROAD CLOSURE GATE PLAN ESTIMATED QUANTITIES CONCRETE FOOTINGS FOR S. D. DEPT. OF TRANSPORTATION DECEMBER 1996 ELEVATION CABLE TIE DOWN FOOTING

STREET LIGHTING GENERAL INFORMATION

SECTION ALUMINUM GEODESIC DOME. This section includes materials, fabrication and erection of the aluminum geodesic dome.

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

SUGGESTED SPECIFICATIONS Pump Frames through 64132

RAOUL WALLENBERG HIGH SCHOOL SECURITY COILING GRILLE SFUSD PROJECT NO SAN FRANCISCO UNIFIED SCHOOL DISTRICT SECTION 08330

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CHAIN LINK FENCES AND GATES

special needs surface trajectory costs. High Efficiency 3. 4.

ANTI RAM SECURITY CHAIN LINK FENCE - 4, MPH SECTION

Transcription:

10-3.24 HIGH MAST CAMERA POLE ASSEMBLY GENERAL The Contractor must furnish and install the following equipment for high mast camera pole assembly as described herein and as shown on the plans: 1. Camera lowering device 2. One high mast pole 3. Composite videocable assembly 4. Pole foundation The high mast camera pole must have a minimum design wind velocity rating of 100 mph x 1.3 gust factor. Steel and concrete minimum dimensions must not be less than shown on the plans. Composite video cable must conform to the specifications described elsewhere in these special provisions. MATERIALS Pole structures must be constructed from galvanized steel. Materials used for construction of structural supports and foundations must be new and conform to material requirements in the Standard Specifications and Standard Plans, unless otherwise stated in these special provisions. Corrosion resistance must be provided with the following methods: 1. Avoidance of contact between stainless steel and carbon steel, between different types of stainless steel (including welding material), and between aluminum and ferrous materials. 2. Utilizing continuous welding to eliminate crevices that retain moisture. 3. Minimizing welding of stainless steel. 4. Use of adequate sections and suitable materials to limit stress related corrosion. POLE TThe pole design must be submitted to the Engineer for review and approval prior to fabrication. Metal parts of steel poles and hardware must conform to the details shown on drawings shown in these special provisions. The high mast camera pole must conform to the requirements in Section 86-2.04, "Standards, Steel Pedestals and Posts," of the Special Specifications, and these special provisions. The pole must include the shaft, access hole, access hole cover, support plate, anchor base and camera-lowering device. The shaft must consist of sections of a round or multisided (16 sides) tapered steel tube with a uniform taper of 0.14-inch per foot. Segment of the multisided poles must be convex and must have minimum bend radius of 4 inches. Steel used in fabricating the pole must be weldable quality steel. No field welding must be performed in the assembly of the pole. The pole must have a reinforced access hole to allow adequate clearance for maintaining and servicing the lowering device. Access hole reinforcement must provide a bending strength equal to that of a

pole without opening. Other hardware inside the pole must accommodate the lowering device. The access door must be hinged to the pole, open horizontally 180 degrees. When the access door is in the open position, it must not interfere with access to the interior of the pole. Unless otherwise shown on the plans, the pole must be installed with the access door towards the controller cabinet. The pole must be erected plumb. The vertical axis of the erected pole must be within 3 inches of the theoretical vertical axis when measured without the action of sunlight or wind. The pole must conform to the requirements of the latest edition and the interim revisions of the AASHTO "Standard Specifications for the Structural supports for Highway Signs, Luminaries and Traffic Signals." The maximum allowable wind deflection must not exceed 7.2 inches under full load conditions, with a maximum wind velocity of 30 mph. An embossed aluminum plate must be attached with rivets to the outside of each pole approximately 2 inches above the access door. The nameplate must indicate the name of the pole manufacturer, the height of the pole and the State's contract number. Plastic laminated data sheets must be secured on the inside of the access door, and must include names, addresses and telephone numbers on the manufacturers of the pole, camera lowering device, and the design parameters, including wind velocity, weight, projected area and coefficient of drag for the camera lowering device with the camera unit installed. CAMERA LOWERING DEVICE The camera lowering device must consist of a head frame, a camera ring, and an internal power drive winch. The maximum projected area of the total assembly at the top of the pole, exclusive of the camera unit, must not exceed 5 square feet. The maximum weight of the head frame, camera ring and cover must not exceed 750 lbs. The head frame must be hot rolled steel conforming to ASTM Designation: A 36, and attached to the pole by means of slip fitter and secured by a minimum of 4 stainless steel set screws conforming to ASTM Designation: F 880, Type 304. The head frame must be fitted with at least 6 hoisting cable sheaves, of either galvanized or stainless steel, or aluminum, with a minimum of 5-inch pitch diameter. The head frame must be fitted with composite video cable assembly sheaves or rollers configured to provide a minimum-bending radius as specified by the composite video cable manufacturer. The hoisting cable sheaves and composite video cable sheaves or rollers must be fitted with suitable keepers to keep the cables in their tracks during pole erection and operation. The sheaves must be supported by stainless steel shafts and must be fitted with oil-impregnated sintered bronze bushings or roller bearings. At least 3 hoisting cables must be supplied. The cables must be 3/16 inch, minimum, in diameter, 7 x 19 strands, stainless steel aircraft cable, manufactured in accordance with Military Specification: MIL-8320B. The head frame must be provided with a cover designed for that device and securely attached with stainless steel machine screws meeting ASTM Designation: F 593, Type 304 requirements and self-locking nuts meeting the general chemical requirements of

ASTM Designation: F 594, Type 304, or a stainless steel clamp band. The shape of the lowering device and the cover must be generally symmetrical about a vertical axis. The camera ring must be fabricated to 6 inches x 2 inches x No. 7 gauge spun steel. The camera ring must be provided with the appropriate number of 3 inches nominal steel tubes to accommodate the integrated camera unit and the counterweights. The mounting arms must be fastened to the ring with stainless steel that can be readily removed in case of a rearrangement of the integrated camera unit. Roller-contact, spring loaded, centering arms must be provided to center the camera ring while ascending and descending the full length of the designed travel on the pole. The arm system must be capable of keeping the ring concentric with pole in the winds up to 30 mph. The rollers for the centering arms must be of a water resistant, non-marking material. All axle shafts for arms and rollers must be of stainless steel conforming to ASTM Designation: A 276, Type 304. The arms system must not allow the pole to be inadvertently wedged between the rollers and the camera ring. Ultimate support of the camera ring must not be lost by an individual or total spring failure. Provisions must be made for leveling the camera ring while in lowered position. The Contractor must level and balance the camera support ring upon installation and again before completion of the contract. The transition assembly must be fabricated from A36 steel. The camera ring must be supported by three stainless steel 7 x 19 strands, 1/4-inch minimum diameter aircraft cable manufactured per MIL-8320B. Each cable must be fitted with a stainless steel fitting which enables it to develop the full strength of the cable. The fitting must attach to the transition assembly within the pole shaft without the use of springs. A ball bearing swivel, of sufficient size to sustain the loading on the cable, with a safety factor of four to allow the attitude of the aircraft cable to be relieved as the camera ring is raised and lowered. The lift cable must pass up through the pole shaft, over the stainless steel head frame sheaves, to the camera ring, where they are led through guides and a compression ring and terminated with a collar-type strand vice device. The compression springs, while supporting the camera ring, are not relied upon for support of the ring in case of spring failure. The safety mechanism must be located in the base of the pole and consist of multipoint safety chain and hook assemblies to maintain the tension on the transition assembly, allowing the winch assembly to be disengaged. Chains must be secured to a plate welded to the inside of the pole shaft. The safety mechanism must be self-contained within the pole and independent of the anchor bolt and pole foundation. Top latch units are not be acceptable. Head frame, camera ring, steel tubes, chains, hooks, poles and hardwares must be hotdipped galvanized after fabrication in accordance with the provisions in Section 75-1.05, "Galvanizing," of the Standard Specifications. The internal mechanism must be capable of raising or lowering the camera ring at an approximate speed of 11 feet/min. The winch must be furnished with 1/4-inch minimum diameter, 7 x 19 strand stainless steel aircraft cable, conforming to Military Specification: MIL-8320B, of sufficient length to maintain at least four wraps around the drum with the camera ring unit fully lowered position. The free end of the winch cable must be finished with a stainless steel compression sleeve sufficient to develop 95 percent of the rated load capacity of the assembly through a ball bearing swivel of sufficient size to sustain the

loading of the cable factor of four. The transition design must be such to prevent twisting of the support cables to assure smooth winding of the cables on the winch and to prevent binding on the inside of the tower shaft. Winch cable must wind uniformly. The internal power drive winch unit must include: 1. A heavy duty, totally enclosed, fan cooled, reversible universal type motor, rated at 115 V(ac) 746 W, minimum, for continuous duty, and provided with overcurrent protection. 2. An adjustable torque limiter with ball or roller bearings on all rotating shafts. 3. A remote control reversing switch (labeled "UP" and "DOWN") with minimum 20 feet cord. 4. Worm-gear driven winch. 5. Mounting frame. 6. Other equipment as necessary. All internal power drive winch unit components, including transformer, must be removable through the access hole for repair or replacement. FOUNDATION The foundation must conform to the requirements for cast-in-drilled-hole concrete pile foundations in Section 86-2.03, "Foundation," of the Standard Specifications and these special provisions. SUBMITTALS Submittals for the high mast camera pole assembly must conform to the requirements in Section 86-1.03, "Equipment List and Drawings," of the Standard Specifications and these special provisions. Submittals must be delivered to the Engineer prior to the erection of the high mast camera pole assembly. The Contractor must submit descriptive data, design working drawings, erection working drawings, calculations, and a list of materials used for the high mast camera pole assembly. The material list must be complete as to the name of manufacturer, catalog number, size, capacity, finish, pertinent ratings, and identification symbols used on the plans or in the special provisions for each unit. Each submittal must consist of 5 copies. Plans and detailed drawings must not be larger than 22" x 34". Each separate item submitted must bear the descriptive title and the State's contract number. INSPECTION AND TESTING All equipment furnished by the Contractor must be subject to monitoring and testing to determine conformance with all applicable requirements and to ensure proper operation of the camera lowering device prior to final acceptance of the project. Documentation as required demonstrating performance and operation in conformance to these special provisions must be furnished by the Contractor as part of this project. All equipment required for conducting tests must be supplied and retained by the Contractor. No separate payment will be made for the monitoring, testing, test equipment, and documentation of test results, but must be included in the amount bid for other pay items.

The State reserves the right to examine and test any or all materials furnished by the Contractor (using the test equipment supplied by the Contractor) for this project to determine if they meet these special provisions and the Standard Specifications. If any material used in the construction of this project is defective or otherwise unsuitable, or the workmanship does not conform to the accepted standards, the Contractor must replace such defective parts and material at no cost to the State. The Contractor may offer rejected equipment again for consideration provided all non-compliance has been corrected and protested by the Contractor. The camera-lowering device must be submitted for inspection and testing. Inspection and testing must be performed at the site and approved by the Engineer. Notification must be given to the Engineer at least 10 days prior to demonstration. The times and dates of the tests must be approved by the Engineer. The Contractor must conduct all tests in the presence of the Engineer. Testing must only take place on weekdays as specified elsewhere in the special provisions. Prior to acceptance of the contract, a trained manufacturer's representative must perform the operational testing of the high mast camera pole assembly. The testing must consist of a minimum of 3 complete cycles of raising and lowering the camera ring (complete with the integrated camera unit connected to composite video cable) the full length of its travel, as designed, within one working day. Notification must be given to the Engineer at least 10 days prior to testing. DOCUMENTATION AND TRAINING After the high mast camera pole assembly is in operation, the Contractor must provide an instructional digital video in Audio Video Interleave (AVI) format on a minimum 8 GB USB version 2.0 Flash Drive or a Secure Digital (SD) card, complete written instructions, and a demonstration to State Maintenance personnel on the maintenance of the high mast camera pole assembly, including leveling of the camera ring and the procedures for the safe raising and lowering of the camera ring. Spare parts, parts lists, and the operating, maintenance and service instructions, packaged with or accompanying the equipment installed on the project, must be delivered to the Engineer prior to acceptance of the project. Full compensation for high mast camera pole assembly is included in the contract lump sum price paid for closed circuit televisions camera system (location 1) and no additional compensation will be allowed therefor.