EFFECT OF COAL BOTTOM ASH AS SAND REPLACEMENT ON THE PROPERTIES OF CONCRETE WITH DIFFERENT W/C RATIO

Similar documents
EFFECT ON CONCRETE PROPERTIES BY REPLACEMENT OF SAND AS THERMAL POWER PLANT POND ASH

A STUDY ON MECHANICAL PROPERTIES OF CEMENT CONCRETE BY PARTIAL REPLACEMENT OF FINE AGGREGATES WITH BOTTOM ASH

Strength properties of concrete with partial replacement of sand by bottom ash

CHAPTER 6 POLYPROPYLENE FIBRE REINFORCED GEOPOLYMER CONCRETE COMPOSITES

STRENGTH PERFORMANCE OF CONCRETE USING BOTTOM ASH AS FINE AGGREGATE

Study and Analysis of High Performance Concrete and Estimation of Concrete Strength

CHAPTER 4 GEOPOLYMER CONCRETE COMPOSITES

Research Article Studies on Strength and Behaviors of Concrete by using Pond Ash as Fine Aggregate

STRENGTH CHARACTERISTICS OF CONCRETE WITH WASHED BOTTOM ASH PARTIALLY REPLACED FOR FINE AGGREGATE

Effect of Calcium Nitrate on the Pozzolanic Properties of High Early Strength Concrete

An Investigation of Steel Fiber Reinforced Concrete with Fly Ash

BRIEF REVIEW ON BOTTOM ASH AS A PARTIAL REPLACEMENT OF FINE AGGREGATE IN ADDITION WITH PPF

EXPERIMENTAL INVESTIGATION ON PARTIAL REPLACEMENT OF FINE AGGREGATE WITH SABBATH (CUDDAPAH STONE) STONE

Study on Strength and Durability of Recycled Aggregate Using Glass Powder

Department of Built and Natural Environment, Caledonian Collage of Engineering, Sultanate of Oman. * Corresponding author:

EFFECT ON MECHANICAL PROPERTIES OF CONCRETE USING NYLON FIBERS

The effect of coal bottom ash (CBA) on mechanical and durability characteristics of concrete

Experimental Study on Rice Husk Ash in Concrete by Partial Replacement

STUDY ON MECHANICAL PROPERTIES OF CONCRETE USING SILICA FUME AND QUARTZ SAND AS REPLACEMENTS

Strength Characteristics of Concrete Mix by Replacing Fine Aggregates with Industrial Sand

STUDY ON CONCRETE REPLACED WITH CRUSHED CONCRETE FINE AGGREGATE

Behaviour of Self Compacting Concrete by Partial Replacement of Fine Aggregate with Coal Bottom Ash

World Journal of Engineering Research and Technology WJERT

Experimental Study on Partial Replacement of cement by Fly Ash with Glass Fiber Reinforcement

Pennoni Associates, Inc.

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October ISSN

EXPERIMENTAL INVESTIGATION ON MECHANICAL PROPERTIES OF POLYPROPYLENE FIBRE INCORPORATED CONCRETE WITH SILICA FUME

Fully Replacement of Natural Sand With hydro Sluiced Bottom Ash in High Performance Concrete with Nanosilica

High Strength Concrete With Pond-Ash as Partially Replaced by Fine Aggregate and Fine Fly-Ash, Alccofine as Cement

SUITABILITY OF SINTERED FLY ASH LIGHTWEIGHT AGGREGATE IN STRUCTURAL CONCRETE

Fundamentals of Concrete

An Experimental Investigation on Performance of Self Compacting Concrete with Partial Replacement of Cement by using Silica Fume and Rice Husk Ash

USE OF JHAMA BRICK DUST AS AN ALTERNATIVE MATERIAL FOR FINE AGGREGATE IN CONCRETE

Effect of cement and fine aggregate replacement with Alccofine and Bottom ash on mechanical properties of concrete

PROPERTIES AND EFFECTS OF COPPER SLAG IN CONCRETE

EFFECT OF RE-VIBRATION ON COMPRESSIVE STRENGTH OF CONCRETE

Mechanical properties of high strength mortar for repair works

An Experimental Study on Partial Replacement of Cement by Ggbs and Natural Sand by Quarry Sand in Concrete

[Huda, 4(3), March, 2017] ISSN: IMPACT FACTOR

Experimental Studies on the Effect of Ceramic fine aggregate on the Strength properties of Concrete

Application and properties of Fiber Reinforced Concrete

A STUDY ON PROPERTIES AND EFFECTS OF COPPER SLAG IN CONCRETE

An Experimental Investigation on Fresh and Hardened Properties of Self Compacting Concrete with Various Fineness Modulus of Robo Sand

High-Strength Structural Concrete with Recycled Aggregates

Comparative Study on the Strength and Durability Properties of M 50 Grade Self Compacting Concrete with Micro Concrete

Impact of Fly Ash and Silpozz as Alternative Cementitious Material in Crusher Dust Concrete [1]

Experimental Investigation on Strength and Durability Properties of RC Concrete Slabs

South Asian Journal of Engineering and Technology Vol.3, No.7 (2017)

EXPERIMENTAL INVESTIGATION OF PARTIAL REPLACEMENT OF FINE AGGREGATE BY QUARRY DUST IN CONCRETE WITH STEEL POWDER

The Influence of Metakaolin on the Modulus of Elasticity of Concrete

A STUDY ON THE ENHANCEMENT OF DURABILITY PERFORMANCE OF FACED SLAB CONCRETE IN CFRD

Effect of Palm Oil Fuel Ash (POFA) on Strength Properties of Concrete

STRENGTH PARAMETERS OF CONCRETE CONTAINING RECYCLED AGGREGATE

Use of Super Absorbing Polymers (SAP) for Internal Curing of Conventional Concrete with Low W/C Ratio

Study of High Performance Concrete with Silica Fume and Glass Fibre

The durability of normal strength concrete: an experimental study

EXPERIMENTAL INVESTIGATION OF WASTE FOUNDRY SAND ON STRENGTH PROPERTIES OF PLAIN CONCRETE AND COMPARISON WITH BINARY BLENDED CONCRETE

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 1, No 3, 2010

ISSN (PRINT): , (ONLINE): , VOLUME-5, ISSUE-5,

Experimental Investigation on Natural Fiber Concrete with Palm Oil Tree Fiber

Questions with Solution

EXPERIMENTAL STUDY OF POLYPROPYLENE FIBRE INCOPORATED CONCRETE

An Experimental Study on Flexural behaviour of Reinforced Concrete Beam by Partial Replacement of Fine aggregate with Coal based Brick- Kiln-Ash

Physical Properties of Steel Fiber Reinforced Cement Composites Made with Fly Ash

D. Maharaj & A. Mwasha University of the West Indies, Trinidad. Abstract

Experimental Study on Concrete by Partial Replacement of Fine Aggregate with Fly Ash and Egg Shell Powder

EXPERIMENTAL INVESTIGATION ON STRENGTH AND DURABILITY CHARACTERISTICS OF HIGH PERFORMANCE CONCRETE USING GGBS AND MSAND

To Study the Flexural, Tensile and Compressive Strength of Reinforced Concrete by Adding Glass & Steel Fibers in Different Proportions

STUDY ON MECHANICAL PROPERTIES OF HIGH STRENGTH CONCRETE USING COCONUT SHELL AS COARSE AGGREGATE

Study on Effect of Steel Dust on Strength Characteristics of Concrete

Technology, Vijayawada, India 2 Assistant professor, Department of Civil engineering College, Vikas Group of Institutions, Vijayawada, India

Investigations on Some Properties of no-fines Concrete

Properties of Fly Ash Based Coconut Fiber Composite

STRENGTH AND BEHAVIOUR OF GEOPOLYMER CONCRETE BEAMS

CHAPTER 5 FRESH AND HARDENED PROPERTIES OF CONCRETE WITH MANUFACTURED SAND

The Effect of Local Available Materials on the Properties of Concrete

Comparative Study Between Externally Cured Concrete And Internally Cured Concrete

Evaluation of Performance of Hybrid Fibre Reinforced Concrete (HFRC) for M25 Grade

Laboratory Analysis of Fly Ash Mix Cement Concrete for Rigid Pavement.

AN EXPERIMENTAL STUDY ON GLASS FIBRE REINFORCED CONCRETE

Effect of Steam Curing on the Strength of Concrete by Using Mineral Admixtures

Puducherry , India. Puducherry , India.

EFFECT OF PARTIAL REPLACEMENT OF CEMENT BY SILICA FUMES ON MECHANICAL PROPERTIES OF CONCRETE

Effects of Fly Ash and Super Plasticiser on Cement Content in M30 Grade Concrete

Wiss, Janney, Elstner Associates, Inc.

A H M 531 C The Civil Engineering Center

CONCRETE USING RECYCLED AGGREGATES

Research Article The Effect of Accelerators and Mix Constituents on the High Early Strength Concrete Properties

Study On Properties Of High Strength Silica Fume Concrete Withpolypropylene Fibre

EXPERIMENTAL INVESTIGATIONS ON DURABILITY CHARACTERISTICS OF CONCRETE DEVELOPED BY USING BRICK POWDER (BP) AND QUARRY DUST (QD)

EXPERIMENTAL STUDY ON CONCRETE BY USING FLY ASH TO ENHANCE ITS DURABILITY PROPERTIES

International Journal of Engineering Science Invention Research & Development; Vol. I Issue XI May e-issn:

STRENGTH AND DURABILITY PROPERTIES OF HIGH PERFORMANCE CONCRETE INCORPORATING SILICA FUME

STRENGTH AND WORKABILITY OF HYBRID FIBER REINFORCED SELF COMPACTING CONCRETE

PREPARATION OF CONCRETE USING GOLD MINE WASTE

Experimental Study on Mechanical Properties of Basalt Fibre Reinforced Concrete

Experimental Investigation on Properties of Concrete by Partial Replacement of Cement with Banana Leaves Ash

Experiments on Partial Replacement of Coconut Shell as Coarse Aggregate in Concrete

Strength and durability of high performance engineered cementitious composites

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Transcription:

EFFECT OF COAL BOTTOM ASH AS SAND REPLACEMENT ON THE PROPERTIES OF CONCRETE WITH DIFFERENT W/C RATIO M.P.KADAM 1, DR.Y.D. PATIL 2 1 Department of civil engineering, NDMVP S KBTCOE, Gangapur road, Nashik-42213, India 2 Department of Applied Mechanics, S V National Institue of Technology, Ichchhanath, Surat-3957, India Email: kadammadhav@yahoo.co.in, chipatil@yahoo.com Abstract The effects of coal bottom ash as fine aggregates in place of sand was used and compressive strength, split tensile strength, flexural strength, Modulus of Elasticity, Density and water permeability are studied. The natural sand was replaced with coal bottom ash by %, 1%, 2%, 3%, 4%, 5%, 6%, 7%, 8%, 9%, and 1% by weight, as water absorption of bottom ash was more so that quantity of water was increased to achieve 1 mm slump. The results shows that the compressive strength, split tensile strength and flexural strength decreased as the percentage of replacement coal bottom ash increased as compared to controlled concrete. In this work slump was kept constant 1 ± 1 mm. To achieve the required slump water quantity was increased as percentage replacement increased. It was observed that up to 3% replacement the results of compressive, flexural, split and water permeability test are approximately same as that of the controlled concrete. Keywords-Coal Bottom Ash; split tensile strength; Flexural strength; Permeability; Modulus of elasticity. I. INTRODUCTION Mix design M-35 grade of concrete was used to study the different harden properties of concrete. Coal bottom ash was taken from Eklahare thermal power plant Nashik city in Maharashtra. Bottom ash has coarse particle size, higher water absorption and usually no pozzolanic effect. Therefore, it is dumped in land fill sites or discharged in pond in mass quantity and is easily available with free of cost. A previous in literature survey has indicated that, thermal power plant bottom ash would be a potential fine aggregate in concrete. The thermal power plants are the main source of power generation in India. These thermal power plants have been generating about two thirds of the power demands of the country. There are about forty major thermal power plants in India. World at present produces around approximately 1528 Million Tons of coal fly ash when India at present produces around 12 Million Tons of Ash per annum [15]. The beneficial use of fly ash in concrete is the preferable option for safe and economical utilization of millions tons of fly ash. There is a critical need to find new methods for using fly ash for its highest and best use. The major obstacle in use of bottom ash in a concrete is that the chemical properties of coal bottom ash are different from place to place and are depends upon the origin of the raw material. It was found that water absorption of bottom ash which is received from Eklahare thermal power plant Nashik was around 1 % greater than natural sand that indicates that the porosity of fly ash is high. Malohtra (1996) reported that at least 7 % of total fly ash is generally suitable for use as a cement replacement in concrete. On Indian scenario it is observed that at very few places good quality of sand may be available in plenty. All metro and mega cities in India are facing acute shortages of good quality of sand. At some places sand available is coarser than Zone I sand and hence not suitable for construction work. In contrast to the sand, bottom ash is available in huge quantity due to more and more thermal power plants in India. II. LITERATURE REVIEW Andrade L.B and Rocha (29) et al reported that the porosity of bottom ash is high so that the w/c ratio of the concrete cannot be taken as exact. Chai Jaturapitakkul and Raungrut Cheerarot (23) reported that bottom ash has a high potential to develop to be a good pozzolanic material. Rafat Siddique (23) carried out a detailed investigation about mechanical properties of concrete mixtures in which fine aggregates was partially replaced with class F fly ash by weight. Trakool Aramraks (26) reported that bottom ash required water content approximately 25 to 5% more than normal concrete to obtain suitable workability and bottom ash concrete was better than permeability of normal concrete. Aggarwal P. and Aggarwal Y. (27) et al reported that the workability of concrete decreased with the increase in bottom ash due to the increase in water demand. H.K. kim and H.K. Lee (211) detailed experimental investigation carried out to evaluate the effect of fine and coarse bottom ash on the flow characteristics and density of concrete mixture and found that both of fine and coarse bottom ash aggregates had more influence on flexural strength than compressive strength. Ratchayut Kasemchaisir and Somnuk Tangtermsirikul (28) reported that durability, chloride ion permeability, 45

carbonation depth and shrinkage in drying with 1% bottom ash where lager than those of the controlled concrete. Mohd Syahrul Hisyam bin Mohd Sani and Fadhluhartini bt Muftah (21) et al reported that Sive analysis conducted on washed bottom ash is more suitable for mortar rather than concreting sand. the limit given by IS: 383-197 except that 6 microns. TABLE I. PHYSICAL PROPERTIES III. MATERIALS AND METHOD Cement-UltraTech 53 grades Ordinary Portland cement was used for this study. This cement is the most widely used one in the construction industry in India. Course and fine aggregates of 1 mm and 2 mm size was used for this study which taken from Masrul-Nashik, Maharashtra and natural sand of river bed was used confirming to grading Zone I of table 4 of IS 383 were procured from Tapi river Nandurbar Maharashtra. Coal bottom ash was obtained from Eklahare thermal power plant Nashik city in Maharashtra. Drinking water was used to improve the workability of fresh concrete. Number of trials was taken to decide the doses of extra water in concrete. To achieve the required 1 mm slump up to 3% replacement of bottom ash no extra water was required but remaining replacement extra was required. Cumulative percentage passing 12 1 8 6 4 2 1 4.75 2.36 1.18.6.3.15.75PAN IS Sieve Size in mm sand bottom ash lower limit upper limit Figure 2. Particle size distribution for sand and bottom ash in Zone- I IV. MATERIALS AND METHOD Figure 1. Particle size distribution after sive analysis of bottom ash A. A Physical properties The physical properties of course fine aggregates and bottom ash was determined. The fineness modulus of bottom ash, sand, 1 mm and 2 mm coarse aggregates was found to be 2.7, 3.75,.6.76 and 7.64 respectively. The specific gravity of bottom ash, sand, 1 mm and 2 mm coarse aggregates was found to be 1.93, 2.62, 2.75 and 2.67 respectively. It was observed that the specific gravity of bottom ash is less as compared to natural sand. It was also found that water absorption is very high as compared with sand and coarse aggregates. Table I show the fineness modulus, Specific gravity and Water absorption of Course aggregates, sand and Bottom ash respectively. Fig.2 shows the grain size distributions of natural sand and bottom ash. Generally the bottom ash was well graded. A majority of the sizes occurred in a range between 4.75 mm to.6 mm very small portion was in between.3 mm to.75 mm. The grain size of natural sand and bottom ash was within The mix proportion chosen for this study shown in table II and III concrete mixture with different proportions of coal bottom ash ranging from % (for control mix) to 1 to 1 % replacement for sand were considered. The M-35 grade mix design was selected for w/c ratio.45. In this study slump was kept 1 ± 1 mm. For this work total 165 cubes specimen, 132 cylindrical specimens and 132 beam specimens were casted and tested for compressive strength, split tensile strength, flexural strength and water permeability. For this work total 429 test specimen were casted and tested. Table I shows the mix proportions and mix ratio. Table II shows the material consumed with different proportions of coal bottom ash with cement in one kg/ m 3. B. A Preparation of test specimens For mixing the concrete a half bag mixture was used. First coarse aggregates of 2 mm, 1 mm were placed in the mixture then sand and cement were mixed together in dry state then water was added and mixed until the homogeneous mixture were obtained. Each batch is mixed around 4 to 5 minutes and then the mixture was placed in a metallic try and immediately the slump was checked before the concrete was placed in different mould. For this work drinking water was used for throughout curing process 46

TABLE II. MIX PROPORTIONS (KG / M 3 ) AND MIX RATIO TABLE III. CONCRETE MIXTURES WITH DIFFERENT PROPORTIONS OF COAL BOTTOM ASH WITH CEMENT IN KG/M 3 Figure 3. Curing tank with specimen V. TEST RESULTS AND DISCUSSIONS C. B Cube Cube of size 15 mm 15 mm 15 mm were used. The cube were cleaned thoroughly a waste cloth and then properly oil was applied along its faces. Concrete was then filled in mould in three layers, while filling the mould concrete was compacted using tamping road of 6 mm having a cross sectional area of 25 mm 2 then the mould are kept on the vibrating table for proper compaction and then the mould are kept on plane and level surface in the laboratory for 24 hours and then cubes are removed from the mould and kept for curing. For this study 132 specimens was casted and tested for 7, 28, 56, and 112 days D. C Cylindrical Cylindrical mould of diameter 15 mm and height 3 mm were used. The oil was applied along the inner surface of the mould for easy removal of cylinder from the mould. Concrete was poured throughout its length and compacted well by tamping road as well as vibrating table. For this report 132 cylindrical specimen are casted and tested. E. D Beam Beam mould of size 1 mm 1 mm 5 mm was used. The oil was applied along the inner surface of the mould for easy removal of beam from mould. Concrete was poured throughout its length and compacted well by tamping road as well as vibrating table. F. E Curing After casting of all cubes, cylindrical and beam specimen are kept for curing in curing tank. The drinking water was used for throughout curing process. While curing process at every week the water was removed and fresh drinking water added up to 112 days G. A Effect of coal bottom ash on compressive strength Compressive strength of concrete mixed made with and without coal bottom ash of cubes size 15 mm 15 mm 15 mm was determined at 7, 28, 56, and 112 days. The test results are given in figure 4 the maximum load at failure reading was taken and the average compressive strength is calculated using the following relation. Here to 1 % of coal bottom ash was replaced with sand and optimum percentage of replacement was obtained at 3 % replacement of bottom ash with sand. For controlled concrete the compressive strength was found to be 27.71, 41.62, and 5.53 and 53.81 N/mm 2 for 7, 28, 56 and 112 days respectively. It was observed that for 1 % and 2 % sand replacement the compressive strength was increased from 4.6 %, 3.5,.1.99,.65and and 3.99 %, 2.4,.61%,.2 % for 7, 28, 56 and 112 days respectively as compared with controlled concrete. The compressive strength was decreased from 3% to 1 % replacement 2.7 % to 22.3%, 4.97 % to 33.66 %, 1.23 % to 38.99, and.78 % to 36.83 % for 7, 28, 56 and 112 days respectively as compared with controlled concrete. The bottom ash concrete gains strength at a slower rate in the initial period and acquires strength at faster rate after 28 days due to pozzolanic action of bottom ash. At early age bottom ash reacts with calcium hydroxide liberated during hydration of cement and does not contribute significantly to the densification of concrete matrix at early ages. It was observed that crack pattern in the cube specimen were formed randomly and cracks are propagated through bottom ash particle were as in controlled concrete the cracks are propagated through coarse aggregates. 47

Figure 4. Compressive strength coal bottom concrete ash with age H. B Effect of coal bottom ash on split tensile strength The specimen of size 15 mm in diameter and length of 3 mm was casted and tested under the digital CTM of capacity 3 ton. The specimen was kept under CTM at the center with play wood of thickness 5 mm at top and bottom and load was applied with pace rate 1.3 KN/seconds and ultimate loading was noted. Split tensile strength was shown in fig.5. The spilt tensile strength was calculated according to IS - 5816-197 and IS 516 1959 code by the relation Where = split tensile strength in N/mm 2, P = Maximum load at failure, L = span, D = Diameter of specimen. The split tensile strength for controlled concrete was found 3.1, 4.34, 5.22 and 5.42 for 7, 28, 56 and 112 days. It was observed that for 1 % to 2 % sand replacement the spilt tensile strength was increased from 14.29 2.29,.1.73,. % for 1 % replacement at 7, 28, 56 and 112 days respectively with controlled concrete. The split tensile strength for 2 % replacement was increased by 8.97 %, and 1.67 % at 7, 28 days and decrease for 56 and 112 days compared with controlled concrete It was found that the split tensile strength decreased from 3 % to 1 % replacement by 1.67 to 4.57 %,.46 to 39.86 %,.76 to 46.55 % and 3.51 to 45.2 % for 7, 28, 56 and 112 days with respect to controlled concrete. Figure 5 shows the split tensile strength at different ages. Splitting tensile strength of concrete decreases with the increased in bottom ash as fine aggregates in place of natural sand. At the time casting it was observed that segregation of particle was fond. After testing the cylindrical specimen bottom ash particle was fond at the top without coarser aggregates having thickness ten to thirty mm. Figure 5. Split tensile strength of coal bottom ash concrete with age I. C Effect of coal bottom ash on flexural strength The beam specimen of size 1 mm 1 mm 5 mm was tested for single point load at the midpoint under the UTM of capacity 1 ton. The flexural strength is calculated as per IS 456 2 and IS 516 1959 by using the relation Where σ b = Modulus of rupture in N/mm 2, P = Maximum load, L = span, b = width of specimen, d = depth of specimen. The flexural strength was increased for 1 %, 2% and 3 % replacement as compared to controlled concrete. For 1 % replacement it was increased by 13.4, 5.45, 5.45 and 4.91 at 7, 28, 56, and 112 days respectively. For 2 % replacement it was increased by 11.18, 3.57, 4.46 and 4.41 at 7, 28, 56, and 112 days respectively For 3 % replacement it was increased by 8.39, 2.19, 2.72 and 2.69 at 7, 28, 56, and 112 days respectively as compared to controlled concrete. The split tensile strength was decreased from 4 % to 1 % replacement from 7.45 to 23.61,.82 to 17.53, 1.73 to 18.56 and 1.72 to 15.2 at 7, 28, 56 and 112 days respectively with compared,to controlled concrete. The bottom ash concrete gains flexural strength with the age that is comparable but less than that of the controlled concrete. It is believed to be due to the poor interlocking between the aggregates, as bottom ash particles are spherical in nature. Figure 6 shows the variation in flexural strength for different replacement with respect to controlled concrete for 7 days, 28 days, 56 days and 112 days respectively. Figure 6 shows flexural strength of concrete. Figure6. Effect of coal bottom ash on flexural strength of concrete with age D Effect of coal bottom ash on density of concrete The densities of hardened concrete specimens with different percentage replacement of natural sand by bottom ash with respect to controlled concrete was shown in figure 5.4. The density of hardened concrete was linearly decreased as the replacement ratio of bottom ash was increased. The density of reference concrete was 2419.85, 2474.67, 2433.19 and 2465.78 kg/m 3 for 7, 28, 56 and 112 days. The density of 1 % replacement was increased by.4 % for 7 days, then it is gradually decreased from 2.31% to 13.53%, 1.32% to 16.32, 2.67% to 14.89 and 1.46% to 18.37% for cube specimen when natural sand was replaced from 1 % to 1 % b y bottom ash at 7, 28, 56, and 112 days. 48

Density of concrete 25 2 15 1 5 7 days 28 days 56 days 112 days cc 1 2 3 4 5 6 7 8 9 1 Percentage replacement Figure 7. Density of coal bottom ash concrete with age J. E Effect of coal bottom ash on modulus of elasticity at 28 days The moduluous of Elasticity of cube specimen is calculated according to IS: 456-2 by the formula where f ck is 28 days cube compressive strength. It was found that the modulus of elasticity decreased in accordance with an increase of replacement of natural sand by bottom ash. The moduluous of Elasticity of reference concrete was.322 1 3 N/mm 2. The moduluous of elasticity for 1 and 2 % replacement is increased by 1.5 % and 1.24 % with respect to controlled concrete then the modulus of elasticity was decreased from 2.75 % to 18.63% as compared to controlled concrete. The figure 8 shows the variation in moduluous of Elasticity for 28 days cube for 28, days. Modulus of Elasticity at 28 days in 1 5.35.3.25.2.15.1.5 Modulus of Elasticity at CC 1 2 3 4 5 6 7 8 9 1 Percentage Replacement Figure 8. Effect of coal bottom ash on modulus of elasticity at 28 days K. D Effect of coal bottom ash on Permeability at 28 days Concrete cubes of size 15 mm 15 mm 15 mm were cast with and without coal bottom ash then the cube is cured for 28 days. The cubes were tested for water permeability. The apparatus consist of compressor with pressure of 5 bars. The cubes were kept in permeability apparatus for 72 hours for water pressure of 5 bars. The cubes are removed from the set-up and all cubes are kept in CTM with the help of splitting device to divide in to two equal parts. After splitting the cubes water penetration were measured immediately. The test results were shown in Figure 9 controlled concrete as well as for different replacement. This test was conducted according to Germen code DIN-148. It was found that the permeability up to 2 % replacement was decreased and after that the permeability was increased from 2.27% to 93.18% from 3 % to 1 % replacement. According to this code maximum permeability allowed is 25 mm. Permeability at 28 days 5 4 3 2 1 Permeability at 28 days CC 1 2 3 4 5 6 7 8 9 1 Percentage Replacement Figure 9. Effect of coal bottom ash on modulus of elasticity at 28 days V. CON CLUSIONS In this report experimental results are presented to evaluate the feasibility of utilizing of bottom ash as fine aggregates in concrete with compressive strength of 35 Mpa for slump as 1 mm ± 1 mm. With different water cement ratio for different percentage replacement with age of concrete and following conclusion. The compressive strength for 7, 28, 56 and 112 days was increased up to 2% replacement and after that compressive strengths were decreased from 3% to 1% replacement. The split tensile strength was increased at 7, 28, 56 and 112 days for 1% to 3% replacement and after that it was decreased for remaining replacement. The flexural strength was increased for 1 %, 3 % replacement and after that it was decreased. The densities of hardened concrete linearly decreased as the replacement ratio of bottom ash was increased from 1% to 1% as compared to controlled concrete. It was found that the Modulus of Elasticity decreased in Figure 1 Permeability test appratus cube specimen at 28 days 49

accordance with an increase in replacement of natural sand by bottom ash. The moduluous of elasticity of reference concrete was 32.2 1 3 N/mm 2. The moduluous of elasticity for 1 % replacement was increased by 1.55 % to 1.24% for 1% and 2 % replacement respectively. It is found that the permeability up to 3 % replacement, decreased and after that permeability was increased from 6 % to 1 % replacement. REFERENCES [1] Andrade L.B., J.C. Rocha, M. Cheriaf, (29), Influence of coal bottom ash as fine aggregate on fresh properties of concrete, Construction and Building Materials, Vol. 23, pp.69-614. [2] Aggarwal P., Aggarwal Y, Gupt S.M.,(27), Effect of bottom ash as replacement of fine aggregates in concrete, Asian journal of civil engineering (building and housing), Vol. 8, no. 1 Pages 49-62. [3] Chai Jaturapitakkul and Raungrut Cheerarot, (23), Development of Bottom Ash as Pozzolanic material, journal of materials in civil engineering, Vol.15, pp.48-53 [4] H.K.Kim, H.K. Lee, (211), Use of power plant bottom ash as fine and coarse aggregates in high- strength concrete, Construction and Building Materials, Vol.25, pp.1115-1122. [5] MalhotraV.M. and Painter K.E., (1996), Early-age strength properties, and freezing and thawing resistance of concrete were incorporating high volume of ASTM class F Fly ash, the international journal of cement composites and lightweight concrete, Vol.11 No.1 pp.38-46. [6] Mohd Syahrul Hisyam bin Mohd Sani, Fadhluhartini bt Muftah, Zulkifli Muda, (21), The Properties of Special Concrete Using Bottom Ash (WBA) as Partial Sand Replacement, International Journal of Sustainable Construction Engineering & Technology, Vol.2, pp.65-76. [7] Rafat Siddique, (23), Effect of fine aggregate replacement with Class F fly ash on the abrasion resistance of concrete, Cement and Concrete Research, Vol.33, pp.1877 1881. [8] Ratchayut Kasemchaisir and Somnuk Tangtermsirikul, (28), Properties of Self-Compacting concrete in Corporating Bottom Ash as a Partial Replacement of Fine Aggregate, Science Asia, Vol.34 pp. 87-95. [9] Trakool ARAMRAKS 26, Experimental Study of Concrete Mix with Bottom Ash as Fine Aggregate in Thailand SEAMEO-INNOTEC 5