Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

Similar documents
BULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS DAVIS, CALIFORNIA

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

WeatherSmart Air Barrier Installation Guide

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

Exterior Stucco and Siding Installation

Fundamentals of Door Installation START

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

The better way to build TM. Installation Manual NAILBASE PANELS

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Product and System Specifications DuPont Flashing Systems

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Stone and Masonry Veneer

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

DuPont. Tyvek Sheathing Membrane Installation Guidelines. Version 2. Canadian Version

Siding and Soffit Installation Guidelines

R-Matte Plus-3: Insulation for the Building Envelope

GA APPLICATION OF GYPSUM SHEATHING

Structalath Twin Trac 316 System Section Corporate P.O. Box 397 Fortson Georgia FAX Technical

Gold Bond BRAND Gypsum Sheathing

GAF EnergyGuard Polyiso Wall Sheathing

application instructions

GYPSUM BOARD AND PLASTER

DuPont Tyvek Wall Underlay Install Guide

SECTION NON-STRUCTURAL METAL FRAMING

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

Zinc Alloy Bead Accessories for Stucco and Plaster Installations ALABAMA METAL INDUSTRIES CORPORATION

Sept 30, 2004 Page 1

HPW Protocol Reference Manual

SRP-AirOutshield UV Issued:

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Inspection Fundamentals: Stucco & EIFS

2019 IAQA Annual Meeting

Multi-Institutional Academic Health Science & Research Center Evansville, IN

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Application Instructions

Stucco Detailing for Buildings With Unique Geometry

Installation Guidelines

3. Aesthetic Groove. 5. Window Head (Flush) 6. Window Head (Recessed) 7. Window Jamb Detail (Flush) 8. Window Jamb Detail (Recessed)

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

Residential Building Inspections

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

Acrocrete Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

WATERGATE COMMUNITY ASSOCIATION 8 Captain Drive Emeryville, California Office: / Fax: WINDOW REPLACEMENT GUIDELINES

SPECIFICATION GUIDELINE

Galvanized Steel Bead Accessories for Stucco and Plaster Installations ALABAMA METAL INDUSTRIES CORPORATION. Contract Number:

CONCRETE MASONRY VENEERS TEK 3-6C

KARRIER PANEL - BRICK

Finestone Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

SECTION THERMAL INSULATION

SECTION GYPSUM BOARD PART 1 - GENERAL

Ultra Wall System. CAD Detail Sets

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

Acrocrete Platinum CI Stucco Ultra Typical details for a premium impact and puncture resistant rain screen design cement plaster stucco system

Guide Specification for the OSI QUAD Window and Door Flashing System

Thin Architectural Splitface Block Veneer Specification Guide

Siding and Soffit Installation Guidelines

SECTION NON-STRUCTURAL METAL FRAMING

R E S I D E N T I A L B U I L D E R S R E F E R E N C E G U I D E

Henri Fennell, CSI/CDT ABX 2015

RevealShield SA Penetrations

City of Long Beach Department of Development Services Building and Safety Bureau. Design Limitation for Wood Shear Walls

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

ORDINANCE NO BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF BOULDER, COLORADO: CHAPTER 98 - Baled Straw Structures SECTION PURPOSE

SECTION GYPSUM BOARD

SPECIFICATION GUIDELINE

Building Division Informational Handout

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

Technical Bulletin. CTIOA Technical Committee

WELCOME. Recommended Window Installation. 1 credit Minnesota Department of Labor and Industry

Architectural Wall Products Guide Specifications

JC Code & Construction Consultants, Inc. Advanced Training: The FBC & ASTM C 1063

SECTION GYPSUM BOARD

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

SURESILL WATER MANAGEMENT GUIDE

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN

A. Section includes fluid applied, vapor permeable membrane air barriers.

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

WEIGHT PER PIECE (LBS.)

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

Building Construction and Water Intrusion

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Overview Revised 11/17/2016

Magnum Board Section Digicon Information Inc. Page 1

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

Perm-A-Barrier VPS (Vapor Permeable Sheet)

SECTION Fiber Reinforced Stucco 1

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: ULTRAKOTE PRODUCTS, LLC

A. Meet at Project site <insert number> days before starting installation.

Section Metal Lath and Accessories

Transcription:

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board In multi-family residential construction, involving fire-rated assemblies stress relief in the firerated assemblies is important, but often overlooked. The 2015 Gypsum Association Fire Resistance Design Manual (the 21 st Edition or GA-600-2015) addresses perimeter relief and control joints in fire rated gypsum panel assemblies in Section II on page 18. It is specifically noted that these control and strain relief designs do not affect the fire rating of any rated assembly. Since the 2009 version or the 20 th edition of the Gypsum Association Fire Resistance Design Manual is a Standard Reference in the 2016 CBC (Chapter 35), this Standard Reference has the same standing as the Code for the 2016 Code Cycle. The 2015 FRDM is not adopted in the 2016 CBC, but why not use the design recommendations in the most current version of this Standard Reference? A number of Strain Relief designs are listed in the 2015 Gypsum Association Fire Resistance Design Manual on pages 279 to 301 and include walls, ceilings, shafts, and head wall conditions. Control joints in the gypsum panel products shall be specified by the architect or designer where any of the following conditions exist: 1. A control joint shall be installed where a partition, wall, or ceiling traverses a construction joint (expansion, seismic, or building control element) in the base building structure. 2. Control joints shall be installed where a wall or partition runs in an interrupted straight plane exceeding 30 linear feet (9m). 3. Control joints in direct applied interior ceilings and suspended ceilings without perimeter relief, shall be installed so that the linear dimensions between control joints do not exceed 30 ft. (9m). 4. Control joints in suspended ceilings with perimeter relief shall be installed so that the linear dimensions between control joints do not exceed 50 ft. (14m). 5. Control joints in exterior ceilings and soffits shall be installed so that linear dimensions between control joints do not exceed 30 ft. (9m). 6. A control joint or intermediate blocking shall be installed where ceiling framing changes direction. 7. Control joints shall be installed where specified by the architect or designer as a design accent or architectural feature. R. Edwards Code Training 1 P age

Distinguishing between Stucco Control and Expansion Joints Sam McInnis and Richard T. Edwards March 2014 Summary: The adoption of the 2010 California Building Code is a reference code with Standard References, having the same enforcement provisions as the Codes themselves. This change highlighted the controversial subject of stucco control vs. expansion joints via ASTM Standard ASTM C-1063-06. (It is very important to note the actual specific year of this Standard Reference. Newer versions have different language than what was adopted and is part of both the 2010 and 2013 CBC). Since 2010, experience has demonstrated that designers and those who implement stucco cladding do not clearly understand the difference. Field project supervisors and tradesmen in particular, often use the terms interchangeably. Stucco control joints provide relief for movement within the stucco cladding (think thermal expansion within the stucco) and act to control stucco cracking, or rather, control the location of stucco cracking. Stucco expansion joints deal with the movement of the entire stucco cladding assembly, which in most instances, involves movement of the underlying substrate (think differential movement of exterior wall building materials wood, steel and stucco). Note that the lath wire must break across both control and expansion joints and be fastened 7 O.C. into solid blocking on both sides of the assembly. However, the expansion or control joint assembly itself may be wire tied to the lath wire. See the diagrams below from ASTM E2266-11 for clarity. Additional photos are provided for clarity. Stucco control joints are normally introduced to limit plaster cracking. Control joints in stucco can be used to separate different textures, different colors or different materials. Plaster is so thin that it must be divided into sections to reduce cracking due to volume changes. Depending on the type of movement expected, the control joint must also be able to move in different directions. Control joints can be specified to move in only one direction, two directions by using some combinations of materials, or by prefabricating those joint at the jobsite. Stucco control joint assemblies (the actual metal assembly) are commonly available as one or two piece joints. R. Edwards Code Training 2 P age

Stucco Control Joints: The stucco control joint is a solid metal assembly that can be found in various types of shapes. The most commonly used and typical patterns of a V or M have a stucco stop/key on each side of the shape. Each side has a securing flange of expanded metal lath wire, or solid GSM stock. The control joint itself may be wire tied or fastened in place on both sides of the control joint. (See attached diagrams). This type of joint functions as a break in the cement plaster, to give the wall plane relief and somewhere to crack. This would be similar in function to a sidewalk v- cut on the surface after so many feet to act as crack relief. These one solid piece joints are classified as control joints. This joint normally deals with the contraction of the mortar mix, and minor expansion and contraction. Shaped as a V or M, these assemblies are normally fabricated with expanded flanges to increase bonding characteristic. The M type provides movement control but also gives the appearance of a narrow reveal. The V type joint is normally used when the area is larger than 144 square feet. Vertical joints should be attached to a stud where necessary. A one piece joint is limited in the amount of movement it can handle and it can only move in one plane. J control joints are normally manufactured with expanded flanges so that the crack is less likely to occur or be exposed. The design of J joints provides locking of the stucco to the edge of the joints and reduces stucco separation at the edge of the joint. The plaster must force stucco under the upside down J shape in order for this bead to perform optimally. They are usually manufactured with tape over the groove so it can be cleaned faster and easier. Stucco Expansion Joints: The typical stucco expansion joint is a prefabricated two piece metal joint that has a stucco stop at each end and a counter flashing slip piece attached to one side for movement. Each metal stop has a nailing flange for securing the joint (see attached figures below). This type of joint functions as a permanent break in cement plaster to give two separate substrates the ability to expand and contract normally, with no adverse effect on the stucco cladding (i.e. raised concrete floor deck-to- wood interfaces above the horizontal sill plate). This would be similar in function to a podium deck concrete slab where a slip-joint provides permanent relief for the movement of adjoining slabs. Stucco expansion joints should be clearly identified and located, as well as differentiated from stucco control joints. A two-piece expansion joint is typically one that can slide in different planes. A flexible selfadhered membrane, as described above, is used to prevent water intrusion that is often an artifact at these assemblies. Expansion joints can also be field-fabricated by using back-to-back casing beads mounted over a flexible membrane flashing. This assembly is described as a control joint in ASTM C-1063-12 (thus not part of the current Code). The authors differ in their opinion with ASTM C-1063-12 in relation to a field assembled control joint. The ASTM language of two casing beads installed back-to-back over a flexible membrane is, in our opinion, describing an expansion joint, and not a control joint. The benefit of using this method is that it is cost effective and water tight when the butt or mitered joint are filled with backer rod and caulking (also as described above). A two-piece joint will manage some larger movements in the range from 1/4 inch to just under 1/2 inch. R. Edwards Code Training 3 P age

Stucco Control or Expansion Joint Waterproofing: Both types of assemblies increase the risk of water intrusion, especially at the intersections in the control and expansion joint assemblies themselves. To specify, detail and diagrams of these assemblies is recommended in all project plans. Sealing all butt joints and mitered seams, for both control and expansion joints, (per ASTM C-926, another Standard Reference) with a backer rod and the appropriate sealant is recommended as a minimum. A self-adhered membrane flashing (SAF) backing is recommended behind the building paper to further reinforce the entire assembly. Proper horizontal lapping of the building paper and SAF is critical for horizontal control or expansion joints. Further guidance can be found in ASTM C-1063-06 and ASTM E2266-11. Note that ASTM C1063-06 requires that the wire lath for the stucco breaks at control joints, and that each side of the wire lath at control or expansion joint assembly must be fastened into solid blocking 7 O. C. There are significant framing implications in this requirement. Further waterproofing guidance can be found in the ASTM publication Standard Guide for Design and Construction of Low-Rise Frame Building Wall Systems to Resist Water Intrusion (ASTM Designation E 2266-11). Note that this publication is not a CA Reference Standard. Control Joint Spacing: The use and spacing of stucco control joints will depend on several factors: type of materials, type of surface and the orientation of the building. Stucco can be applied over concrete and masonry surfaces and will only require joints where there is a change in material or over concrete joints. If stucco is applied using metal lath, joint spacing is usually implemented by following Portland Cement Plaster/Stucco Manual (EB049) which in turn is based on ASTM C1063, Standard Specification for the Installation of Lathing and Furring to Receive Interior and Exterior Portland-Cement Based Plaster requirements. The Northwest Wall & Ceiling Bureau Portland Cement Plaster: Stucco is also another design source often quoted, but this document is not a CA Reference Standard. Generally, joint spacing should meet these general criteria: Joint spacing should not be greater than 18 feet in any direction. No panel should exceed 144 sq. ft. on vertical applications. No panel should exceed 100sq. ft. over curved or angular sections. No length-to-width ratio should exceed 2 ½ to 1 in any given panel. Control joints should be installed at all horizontal floor lines. It is not recommended to install vertical control joints over windows and doors. R. Edwards Code Training 4 P age

The authors would like to convey that providing a weep water exit point at each horizontal control joint has proven to be a better method that is not clarified in ASTM C-1063-06. To accomplish this, the weather resistive barrier (WRB) below the control joint is lapped behind the entire horizontal joint assembly. Self-adhered flashing (SAF) is also lapped behind the entire assembly to help self-seal around the numerous penetrations. The building paper above the horizontal control joint is the lapped onto the upper edge of the control joint flange so weep water exits at the control joint. The first photo below illustrates how this is typically accomplished. Finally, the authors are compelled to offer their opinion about wire-tied control or expansion joints from their combined experience inspecting tens of thousands of structures over 20 some years. Wire tied joints often move during installation, especially with gun applied stucco. This movement results in less than straight final assemblies. Wire tied joints made sense when wire lath was continuous across control or expansion joints, but with the requirement that lath wire must break at all such joints, wire tied control or expansion joints seem out dated, and arguably do not perform was well as tightly fastened assemblies. R. Edwards Code Training 5 P age

Figure 1. An example of a weeping horizontal control joint showing the upper WRB lapped over the control joint flange to shed water from the wall area above. Photo by Sam McInnis. R. Edwards Code Training 6 P age

Stucco Control Joints diagrams and example photos: Page 29, ASTM E2266-11 Reprinted, with permission, from E2266-11 Standard Guide for Design and Construction of Low- Rise Frame Building Wall Systems to Resist Water Intrusion, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428. A copy of the complete standard may be obtained from ASTM International, www.astm.org. R. Edwards Code Training 7 P age

Page 31, ASTM E2266-11 Reprinted, with permission, from E2266-11 Standard Guide for Design and Construction of Low- Rise Frame Building Wall Systems to Resist Water Intrusion, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428. A copy of the complete standard may be obtained from ASTM International, www.astm.org. R. Edwards Code Training 8 P age

Figure 2. A typical horizontal control joint with the lath wire properly fastened at both sides and the control joint assembly fastened (not wire tied) in place. Note that the self-adhered flashing that underlies the entire assembly. Photo by Sam McInnis. R. Edwards Code Training 9 P age

Figure 3. A vertical control joint. Photo by Sam McInnis. R. Edwards Code Training 10 P age

Stucco Expansion Joint Diagrams: Page 35, ASTM E2266-11 Reprinted, with permission, from E2266-11 Standard Guide for Design and Construction of Low- Rise Frame Building Wall Systems to Resist Water Intrusion, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428. A copy of the complete standard may be obtained from ASTM International, www.astm.org. R. Edwards Code Training 11 P age

Page 34, ASTM E2266-11 Reprinted, with permission, from E2266-11 Standard Guide for Design and Construction of Low- Rise Frame Building Wall Systems to Resist Water Intrusion, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428. A copy of the complete standard may be obtained from ASTM International, www.astm.org. R. Edwards Code Training 12 P age

Page 37, ASTM E2266-11 Reprinted, with permission, from E2266-11 Standard Guide for Design and Construction of Low- Rise Frame Building Wall Systems to Resist Water Intrusion, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428. A copy of the complete standard may be obtained from ASTM International, www.astm.org. R. Edwards Code Training 13 P age

Page 38, ASTM E2266-11 Reprinted, with permission, from E2266-11 Standard Guide for Design and Construction of Low- Rise Frame Building Wall Systems to Resist Water Intrusion, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428. A copy of the complete standard may be obtained from ASTM International, www.astm.org. R. Edwards Code Training 14 P age

Page 39, ASTM E2266-11 Reprinted, with permission, from E2266-11 Standard Guide for Design and Construction of Low- Rise Frame Building Wall Systems to Resist Water Intrusion, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428. A copy of the complete standard may be obtained from ASTM International R. Edwards Code Training 15 P age