SECTION LIGHTING

Similar documents
B. Prismatic acrylic diffusers for fluorescent fixtures shall be A12 pattern and at least 1/8 thick. Do not use styrene lenses.

Lighting. Sections Included In This Section: 1.1 General 1.2 Exterior Lighting 1.3 Interior Lighting 1.4 Exit Lighting 1.

SECTION EXTERIOR ATHLETIC LIGHTING

SPECIAL SPECIFICATION 8710 Decorative Pole Lighting Assembly

Optics Mounting Lamping Finish Voltage Options. T6 Metal Halide* H039T6 1 39wT6 H070T6 2 70wT6. H w H070 70w H w

SPECIAL SPECIFICATION 1276 Pedestrain Overpass Lighting

SECTION LUMINAIRES AND ACCESSORIES

1.05 Quality Assurance A. Manufacturers Qualifications: Page 1 of 5 Rev

Project: Type: Qty: Optics. Series. Reflector Mounting Lamping Finish Voltage Options BLC - S BLC-L 21 1 /4" 36 1 /4" 3 1 /2" O.D.

A. Section Cast-in-Place Concrete: Materials and installation requirements for concrete bases for poles.

R Scale: 3/32 = 1-0. Scale: 3/32 = 1-0

Solano Community College District Lighting Standards

EOS 3.0 RECESSED PERIMETER

SECTION LIGHTING. A. Section Basic Electrical Materials and Methods

Monument and Exterior Sign Submittal Requirements

This document is provided as a reference for the design team and should not be used directly as written project specifications.

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES OFFSET TYPE

Commercial Rebate Lighting Program Application/Confirmation

FX1 and FX2 LEDGINE LED Flood Light. Learn more about Philips Luminaires at philips.com/luminaires.

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES, CUTOFF TYPE

CITY OF GOODLETTSVILLE PARKS AND RECREATION DEPARTMENT

City of Dallas Dan Koss, PE, LC 8/23/2016

Cover and above: LED Solution replacing an existing HPS product by another manufacturer

BOLLARDS LANDSCAPE & PATHWAY LIGHTING GARDCO LIGHTING

15-06 Morlot Avenue, Fair Lawn, NJ USA Tel: (201) Fax: (201)

50 Watt Low Profile LED Canopy Light V AC - Motion Sensor - IP65 Rated

Light levels should be appropriate for the task and per the following guide in Part 1 - General.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

HUNTINGTON STATION POWER FLOOR PLAN

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

light FULL BLEED APPLICATION SHOT RENDERING

DIVISION 1100 TRAFFIC

DMS HIGH MAST LIGHT FIXTURES

SECTION EXTERIOR LIGHTING

SERIES VAP EXAMPLE: VAPRC2CL26TTTBKMV WATT CAT# APPLICATIONS FEATURES & BENEFITS SPECIFICATIONS ORDERING DATA

5-1 Street Lights Required Street Lights on Private Roadways Developer s Responsibility...5-1

SECTION SPORTS FIELD LIGHTING

INTERIOR & EXTERIOR LIGHTING DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 LUMINAIRES

4809 W. Hwy 290 Sunset Valley, TX 78735

I-BEAM LED The Top Choice For Your Bottom Line.

SECTION DIRECTORIES

50 Watt Low Bay LED Light Fixture - Outdoor Rated - IP67-4,333 Lumens

Lighting. Document Information. Approval. Document History. Document Name Roche Energy Efficiency Standard: Lighting. Document Owner Thomas Wolf, LSE

CONTENTS. B. System Design and Performance Requirements

MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE

SECTION EXTERIOR LIGHTING

SECTION ORNAMENTAL ALUMINUM RAILING

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features

90 Watt Traditional LED Wall Pack - Replaces 400 Watt Metal Halide Fixtures - IP65

Light levels should be appropriate for the task and per the following guide in Part 1 - General.

Light is straightforward SYLVANIA LED Luminaires

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION

Height Finish Pole Options. Series Optics Mounting Lamping Finish Voltage. Metal Halide HPS. H w H070 70w H w H w

B. Verify that electrical installation may be made in complete accordance with all pertinent codes and regulations and the original design.

COVER UP MULTIFACETED DISTRIBUTION

SECTION DECORATIVE METAL FENCES AND GATES

STREET LIGHTING GENERAL INFORMATION

DIVISION 26 ELECTRICAL EXTERIOR LIGHTING

50 Watt LED Wall Pack Light - 500W Quartz Halogen Equivalent - (4) 12.5W High Output LEDs

DISCONTINUED CFL. Specifications. Compact Floodlights revision 11/13/14 kl_cfl_spec.pdf. Fixture Options: Approvals: Job: Fixture Catalog number:

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

3 WALL ASYMMETRIC W W W. L U M E N W E R X. C O M

architectural lighting

Facette Wall luminaires for discharge lamps or incandescent lamps

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

Special Specification 6244 LED High Mast Illumination Assemblies

MATERIAL SPECIFICATION FOR HIGH PRESSURE SODIUM LUMINAIRES FOR HIGHWAY LIGHTING

HEALTHCARE & SCHOOL LIGHTING

POWERFUL PERFORMANCE. High performance Nichia 80+ CRI LEDs provide an optimal light source for tailored lighting design GYPSUM BOARD 8.

PRODUCT SPECIFICATION

Operable / Fixed Skylight Milgard Aluminum Window

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

VIA 3 LED RECESSED WALL WASH V. 2 W W W. L U M E N W E R X. C O M

PROYECTOR KOKOH UNE EN IK10 IP66

GARDEN CITY STNANDARD REVISIONS FOR ISPWC DIVISION 1102 STREETLIGHTS

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

CONTENTS. B. System Design and Performance Requirements

LIGHTPLANE 2 SPECIFICATIONS. QuickShip. LP2 Suspended, Wall, Surface LED. alwusa.com/lp2. Eligible. Find additional images and information at

new equipment & construction

LED Recessed Lighting. Diamond Series LED Retrofit Platinum Series LED Housings and Trims LED Step Lighting. I l l u m i n a t i n g t h e f u t u r e

SHALO 3 LED RECESSED W W W. L U M E N W E R X. C O M

5 year. 25W led Flood light. led info. 100,000+ hours. lflled TEST FORWARD CURRENT (ma) # OF LEDLinX MODULES

Special Specification 6156 LED High Mast Illumination Assemblies

SUPERPLANETM SPECIFICATIONS. QuickShip. SP4R Recessed ControlRoll TM. Optics LED. alwusa.com/sp4r. Eligible. Find additional images and information at

FULL BLEED APPLICATION SHOT RENDERING

SECTION SOLID PHENOLIC PLASTIC TOILET PARTITIONS

Quick Facts LED AREA FIXTURES. Modern bollard produces 360 spread without glare. Aluminum construction. RGBW capable with ZDClink systems.

Elegance & Bollards. 830 Series LED

2010 CA Higher Education Sustainability Conference

Outstanding Performance. Exceptional Value.

ARP 035: UPDATE AND GENERATING COST COMPARISONS

LED lighting solutions based on Light Engines technology. Hervé Barcelo October 2011

Trex Commercial Products page Metal Railing

LIGHTPLANE 3.5RWL LP3.5RWL RECESSED, WET LOCATION

Embry-Riddle Aeronautical University Signage Specifications 03/25/2008

CONSTRUCTION STANDARDS SECTION CS 15 STREET LIGHTING

SECTION PASS WINDOWS. 1.1 SUMMARY A. Section Includes: 1. Factory finished sliding glass, counter mounted pass windows.

SECTION SECTIONAL OVERHEAD DOORS

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

LIGHTPLANE 2 UP + UNDER

Transcription:

PART 1 - GENERAL 1.1. RELATED SECTIONS: 1.2. SCOPE OF SECTION: This section contains the requirements for equipment and installation related to exterior, interior, and special lighting applications. 1.3 GENERAL: A. It is the responsibility of each project to provide all security and parking lot lighting necessitated by that project. B. New exterior lighting installations should be in character with the architecture or its surroundings. Attention should be given to established historic districts or buildings. Exterior lighting in particular must utilize fixtures that provide superior glare control according to IES (full cutoff type optics). C. Avoid specifying incandescent lighting, especially in hard-to-reach locations. D. For energy conservation, extended architectural lighting should be avoided. 1.4 EXTERIOR LIGHTING: A. LAMP TYPE: On the Main Campus, exterior lighting shall be metal halide. On the Health Sciences Campus, the exterior lighting shall be high pressure sodium. B. FIXTURES: The following indicates the fixture type, by application: 1. Pole Mounted Fixtures, Close to Buildings: a. Fixture shall have square shape, sharp cutoff type, with flat, tempered glass lens in a hinged aluminum frame. b. Mounting height shall be 12' to 18' in the vicinity of trees; otherwise, mount at 27' to 31'. c. On Main Campus, fixtures shall have a dark bronze anodized finish. On Health Sciences Campus, fixtures shall have a natural anodized brushed finish. d. Housing material shall be.188" extruded aluminum with all welds and fasteners concealed. All exposed hardware shall be of stainless steel construction. Page: 1 of 6

e. Optical system is to be 90 degrees field rotatable, of homogenous sheet aluminum, electrochemically brightened and sealed. f. On Main Campus, round tapered pole shall be aluminum dark bronze anodized finish. On Health Sciences Campus, round tapered pole shall be aluminum natural anodized brushed finish. Consult project manager if more than 2 fixtures to be mounted on pole. g. Acceptable Manufacturers: Gardco, Kim, or Sterner. 2. Wall Mounted Fixtures, Buildings and Walls: a. Housing material shall be die cast or extruded aluminum with all welds and fasteners concealed. All exposed hardware shall be of stainless steel construction. b. Acceptable Manufacturers for Health Sciences Campus: Lumark; Main Campus: McPhilben or Kim. 3. Pole Mounted Fixtures, Streets and Parking: a. Fixture shall have square shape, sharp cutoff type, with flat, tempered glass lens in a hinged aluminum frame. b. On Main Campus, fixtures shall have a dark bronze anodized finish. On Health Sciences Campus, fixtures shall have a natural anodized brushed finish. c. Housing material shall be.188" extruded aluminum with all welds and fasteners concealed. All exposed hardware shall be of stainless steel construction. d. Optical system is to be 90 degrees field rotatable, of homogenous sheet aluminum, electrochemically brightened and sealed. e. On Main Campus, round tapered pole shall be aluminum dark bronze anodized finish, 40 nominal length. On Health Sciences Campus, round tapered pole shall be aluminum natural anodized brushed finish, 40 nominal length. Consult project manager if more than 2 fixtures to be mounted on pole. Poles shall be rated for 100 mph wind with 1.3 gust factor (minimum). f. Acceptable Manufacturers: Gardco, Kim, or Sterner. C. FIXTURE MOUNTING ON POLES: Page: 2 of 6

Fixtures shall be fastened with stainless steel hardware through factory drilled holes. Field cut holes are not allowed. D. FIXTURE MOUNTING ON WALLS: Fixtures shall be vandal resistant and securely mounted. Plastic anchors are not allowed. E. LIGHT LEVEL: Minimum maintained light level shall be 2.0 footcandles in parking lots and streets. High security areas may require as much as 5.0 footcandles minimum maintained light level. F. GROUNDING: Pole bases shall have reinforcing steel bonded together and connected to an equipment grounding conductor at the pole on a grounding lug inside the handhole. Bond ground to the branch circuit equipment grounding conductor and to a minimum of ¾ x 10 copper plated, steel ground rod at the bottom of each pole. G. CONTROL FOR MAIN CAMPUS: 1. Unless otherwise noted or specified by Project Manager, all exterior lighting shall be controlled by an Astronomic type time clock with battery back up. Time clock channel(s) shall provide the 120 volt control power to energize electrically held, multi-pole, lighting contactors of various voltages. 2. Exterior lighting circuits shall be segregated and fed by different lighting contactors so as to zone the lighting to prevent complete blackout in the event of coil failure or contactor failure. 3. Time clock shall be two (2) channel type for controlling up to two different lighting circuits that operate at different hours. 4. Power to time clock shall originate from a dedicated 120 volt source. 5. Time clocks that control emergency lighting circuits shall also be powered from an emergency power source. 6. Approved Time Clock: Tork DZS-200A or equal by Paragon. 7. Building and parking lot lights should be separately controlled. Page: 3 of 6

H. CONTROL FOR HEALTH SCIENCES CAMPUS: 1. Security lighting which will stay on all night should have photo-cell control; parking lot, architectural, and other lighting, which may not need to be on all night should have combination photo-cell and timer control. Time control shall be provided by the building EMCS if present. Photo cell control should operate section of lighting from one photo cell. 2. Exterior lighting circuits shall be segregated and fed by different lighting contactors so as to zone the lighting to prevent complete blackout in the event of coil failure or contactor failure. 3. Building and parking lot lights should be separately controlled. 1.4 INTERIOR LIGHTING: A. FIXTURES: 1. Fixtures shall be identical to fixtures currently in use when practical. Consult with Project Manager when making selection. 2. Each fluorescent fixture shall be equipped with one or two ballast. Fixtures may not be tandem wired. B. LAMPS: 1. Fluorescent lamps shall be Low Mercury Green Tip T8 fluorescent lamps with 4100 K color temperature, minimum Color Rendering Index (CRI) of 85. 2. Fluorescent lamps shall have rated life of 20,000 hours with rapid start ballast and 15,000 hours with instant start ballast. Instant start ballast shall be used only where lighting remains on continuously such as egress lighting. 3. Acceptable Manufacturers: Lamps shall be equal to Phillips TL80. C. BALLASTS: 1. Ballasts shall be electronic, high frequency (at least 20 khz), designed specifically for use with T8 lamps. 2. Ballasts shall be third party listed (Class P) with a Class A sound rating. 3. Ballasts shall produce less than 10 percent Total Harmonic Distortion (THD) in the input current waveform and shall operate at a power factor of at least 90 percent. Page: 4 of 6

4. ONLY one or two lamp ballasts are acceptable. 5. Qualifying manufacturers shall have been manufacturing electronic fluorescent ballasts for a minimum of five years with a satisfactory performance record. Ballasts shall be warranted by the manufacturer for a minimum of five years. 6. Acceptable Manufacturers: Advance, MagneTek, Osram, Motorola, or approved equal. 7. PCB Ballast Disposal: Unless existing ballasts are labeled to indicate no PCB's, it shall be assumed they contain PCB's; and they shall be legally disposed of at the contractor's expense. 8. Dimming Ballasts shall be architectural grade, equal or better than the Lutron FDB series. D. CONTROLS: 1. Consideration should be given to the full range of lighting control options including occupancy sensors, dual level control, separate switching of daylight zones, dimming controls, and EMCS control. 2. Occupancy sensors, such as dual technology, are required on all classrooms, computer labs, teaching labs, and auditoriums. 3. Consider low voltage lighting controls. Low voltage controls may provide reduced installation costs and improved flexibility for future changes in switching configurations and control methods. E. EMERGENCY EGRESS LIGHTING: 1. EGRESS LIGHTING shall be provided as required by code for a minimum of ninety minutes after a power failure. The following methods may be used, with preference in the order listed. a. Connection of selected fixtures to emergency generator circuits (if available). b. Wall or ceiling mounted battery back-up fixtures with low voltage incandescent spot or flood lights. 2. EXIT SIGNS: a. GENERAL: In buildings without emergency generators, provide exit signs with battery back-up and charger. Page: 5 of 6

b. TYPE: Exit signs shall be completely solid state with Light Emitting Diodes (LEDs) as light source and minimum 5-year warranty on fixture, batteries, and lights. Sign facing shall provide full uniform illumination. Main Campus exit signs shall be all white die-cast aluminum housing with white face, red letters. Health Sciences Campus exit signs shall be black aluminum housing with brushed aluminum face with green letters. c. ACCEPTABLE MANUFACTURERS: Lithonia, Emergilite, or Exide or equal. END OF SECTION Page: 6 of 6