Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

Similar documents
Scales: (Inches) Nominal Length Type and Location. Percentage on tube or Direct Reading on external metal scale with blank tube

LIQUID METER TYPE FMO

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

SITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview

Float Flow Meters series NF

Flow Meters with Float constructive series AF and BF for liquids and gases with remote flow indication

TOPAS PMG / PMH Hydraulic sensor Hot water

Magnetic float switch For vertical installation Model FLS for nuclear power plants

Flow measurement of Liquids and Gases

FLOMID FX Electromagnetic Flowmeter

U6 SERIE PRINCIPLE TECHNICAL FEATURES. Measuring range: 1 to 1600 m 3 /h [Water at 20 C] 180 to Nm 3 /h [normo m 3 /h of air] MATERIALS

Model 140MX Flowmeter Functional Overview

PRODUCT INFORMATION. Model 140MX Flowmeter Functional Overview. PI 14-1 Rev: 1 March 2002

VARIABLE AREA FLOWMETER EASYFLOW.

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

CH88 In Situ Flue Gas Oxygen Transmitter

10A4500 / 10A4600 VA Master TM Indicating Flowrator

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

TOPAS PMG Hydraulic sensor hot water

Process Inline Filter, Change-Over

Gilflo ILVA Flowmeter with Mass Flow Transmitter and Compact Stem DN250 and DN300

DIVA flowmeter. for saturated steam flow measurement

ZDM. Positive Displacement Flowmeter

Tuffy II Liquid Level Controls with Electric Switches

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

ELS LEVEL SWITCH ELS. ELS B10p, ELS B10x, ELS B101x ELS K01, ELS K02, ELS K03 ELS P01, ELS P03, ELS P04

SCS-AMM15 : ADMIX SHOTCRETE MEASUREMENT SYSTEM

Turbine Meter. P e

STANDARD TECHNICAL SPECIFICATION FOR ROTAMETER VOLUME - IIB. SPECIFICATION No: PE-SS I010

Liquid level switch BW 17

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

Oval Wheel Meter Innovations from 1932 until today. Description. Measuring Ranges. Technical Data. OR ,03-1 l/min G¼. OR ,2-7 l/min G¼

TUFFY T3. Side Mounting Level Controls. Worldwide level and flow solutions FEATURES MODELS APPLICATIONS AGENCY APPROVALS

Flanged Water Meters (non-continuous flow)

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

VLM10 In-line Vortex Mass Flow Meter

Averaging PITOT Tube 5RD series

Capacitive switches for underlay applications. And your panel becomes active!

Averaging PITOT Tube 5RD series

SERIES OVAL GEAR FLOWMETER MOGF

Electromagnetic flowmeters. dg: NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12

Coriolis Mass Flow Meter

Flowmeters. Positive Displacement meter. Coriolis mass flowmeter. Turbine flowmeter. Ultrasonic flowmeter

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Variable Area Flowmeters Model 28

Dorot Irrigation Meter

Diaphragm pressure gauge

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

TURBINE METER SERIES FMT-S

BM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS

P430 Series. Glass Tube Variable Area Flow Meter. Product Features and Options: Contact Information:

ALTOFLUX IFS 4000/4005

Models A6100 & A6200 Purgemaster SNAP-IN Small Flowmeter. Long-term reliable performance flowmeters with low cost-of-ownership

Tuffy II Liquid Level Controls with Electric Switches

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

KRAL Volumeter - OMG Series Universal Flowmeters

Gas Measured: Oxygen Methane Carbon Dioxide Carbon Monoxide

FLUIDISTOR GAS FLOWMETER GD 100 (EX)

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Model B. Thermostatic Control Valves. Typical applications

Gilflo flowmeters. for steam, liquids and gases

Standard Bourdon tube pressure gauges EN 837-1

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

KRAL Volumeter - OMG Series Universal Flowmeters

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

Contrans P Transmitter. Integral Orifice Assembly / EN. Measuring section for the measurement of small flow quantities

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

OPTIMASS 7400 Technical Datasheet

R-100 Series GLASS TUBE FLOWMETER SIMPLE, BUT RELIABLE BEST COST PERFORMANCE GENERAL FEATURES MODEL CODE

Using the PPM2 Portable Trace Moisture Transmitter

Continuous Flow Monitoring. In-situ, low maintenance devices for continuous measurement of hot gas flow

Product Features: An excellent solution for measurement of flowrate for water, air and nitrogen.

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

QUALITY INDUSTRIAL FLOWMETERS

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting

Gilflo ILVA flowmeters for steam, liquids and gases

KRAL Volumeter - OME Series Economy Flowmeters

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

602VFM MULTIVARIABLE VORTEX MASS FLOWMETER

Flow Rate Transmitters/ Flow Switches

Accessories for Sample Gas Probe GAS 222

602VFM MULTIVARIABLE VORTEX MASS FLOWMETER

OM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Eletta Flow Monitor for use in explosive atmospheres

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Thermostatic Control Valve

Sho-Rate TM Models 1250 & 1255

Glycerine filled Bourdon tube pressure gauges EN 837-1

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Standpipe Meters and Hydrant Flushing Unit STM-E, STM-N, STM-T, STW The mobile tapping points for taking water from hydrants

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

TEK-B AR 3120B. Smart Gauge Pressure Transmitter. PRESSURE. Technology Solutions

Consumption meter type SF-586a for compressed air and gases

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flowrates

Transcription:

process measurement solutions 3 Rotameter Series 3 glass tube variable area flowmeter Data sheet 70 A range of quality glass tube V.A. flowmeters for general purpose & industrial applications Robust construction Cost effective design Flanged or threaded connection Customised scales Alarm outputs Interchangeable tube or float without re-calibration Glass tube for long life Accurate Lightweight design for pipework support Choice of wetted materials Philosophy The Rotameter series 3 is a new addition to the VA meter range from The Solartron Mobrey Group. Comprising medium to large glass tubes, it is suitable for monitoring both liquid (0.00 to 3 l/min) and gas flows (0. to 00 l/min). The borosilicate glass tube coupled with the choice of other wetted parts, ensures that the 3 is compatible with most fluids. The 3's rugged chassis offers excellent protection of the tube and the availability of both flanged and threaded connections gives ease of mounting. The lightweight construction enables simple in-line pipework mounting, without the need for additional w or bracket support, owing use in both light and heavy industrial areas. Principle of operation Rotameters are utilised for the flowrate measurement of most liquids and gases with direct readout of flowrate. A special "float" is fitted within a tapered glass tube. With the flow verticy upward through the meter, the float settles at a position where its mass is balanced by the upward forces of the flow through the annulus between the tube and float. The greater the flow the higher the float rises to increase the annulus and balance. The top edge of the float is read against the scale, giving an instantaneous reading of the flow rate. Various methods of alarm output are available for signing low or high flow conditions.

Specification Accuracy: scale length: Scale units: Temp. max: max.: +/-.0 % of full scale reading 300 mm nominal customer specified 0 0 C -nitrile seals 0 C -viton seals 60 0 C -PVC seals 00 0 C on request see table below Construction:- Tube: borosilicate glass Chassis: polyester painted aluminium, optional epoxy paint Float: stainless steel 3L - code I or IA aluminium - code D or DA PVC - code P or PA Seals: Nitrile (0 0 C) standard Viton ( 0 C) & PVC (60 0 C) Float stop: Stainless steel 3L, optional PVC Maximum pressure and viscosity ceiling Tube size ( see table below for flowranges) 7 7 Max. operating pressure (Bar) liquid 7 6 gas 3 3 3. gas with polycarbonate screens 7 3. 3 Option Z7 required Viscosity max (centipoise).. 7.. 3. Float material Floats are available in three different materials as shown above, float codes with a suffix A have an encapsulated magnet within Flow Ranges, Sizing and Drop The table below shows the nominal flow ranges available for each tube and float combination.the flow range details shown are water at 0 0 C for liquids and Air at 0 C and 3.abs the float, to opperate an optional reed switch alarm. This option is available on tube sizes to ( atm) for gases. Customised scales are available in any flow units, for most liquids or gases. For sizing assistance please consult the sales office. Flow Range and Drop Tube size Flow rate code St Stl float I or IA Liquids PVC float P or PA Flow rate code Gases Duralium float D St Stl float I or IA Duralium float, DA,,,,3 7 x 7 x x x x x 7 x 7 7 a x M M M3 M M M6 M7 M M M M M M3 M M M M7 M M M0 M M 0.- l/h -.7-7 3-30 - 6-60 -0-0-00 30-300 -0 70-700 0.- m 3 /h 0.-. 0.- 0.3-3.3 0.6-6 0.- -.- -0 6 7 3 0 0 60 7 7 0.6-6 l/h - -0.- 3.- - -0-0 -0 0-00 -0 70-700 0.- m 3 /h 0.-. 0.-. 0.-. 0.6-6 0.- - - 3.- 3. 0 0 0 MG MG MG3 MG MG MG6 MG7 MG MG MG MG MG MG3 MG MG MG MG7 MG MG MG0 MG MG - 0-00 -0-0 60-600 0.- m 3 /h 0.-. 0.- 0.3-3 0.- 0.- -.- 3-30 - 6-60 -0-0 - 0-00 -.. 3 3. 0-00 l/h 30-300 -0 0.- m 3 /h 0.-. 0.- 0.3-3 0.- 0.6-6 -.6- -0 3-30.- -0 m 3 /h 6-60 -0-0 - 0-00 -.. 6.. 7 30 3 0 0 For higher or lower flow ranges consult the sales office. Float s I, IA, D, DA, are guided when used in tube sizes 7 &. The flow range of each tube/float combination given above is the nominal range available. Please check with the sales office for the maximum and minimum scale values for your application.

Application The Series 3 is a general purpose unit for most industrial and laboratory applications. It is idey suited for medium to low pressure gas or liquid flows where clear, accurate flowrate indication is required with or without flowrate alarms. The 3 is classified as simple apparatus* therefore can be used in hazardous and non-hazardous areas. With the chemicy inert borosilicate glass tube and choice of other wetted materials, the 3 can be used on air or water in addition to a wide range of chemical flows. The Series 3 is part of a large range of Rotameters available from the Solartron Mobrey Group, including :- metal tube meters for high pressures or electrical output of flowrate ( to 0 ma) and other glass tube meters for applications such as :- very low flows, high accuracy test rig use, low cost purge meters, quick release tubes and units designed for behind panel mounting. For details of the complete range of Rotameters (Variable Area flowmeters) available from the Solartron Mobrey Group ask for sales brochure no. IP330. * When used with or without alarm S. 3 Features Lowest cost instation. Unique PVC connection glues directly on to PVC pipework saving instation time and the cost of additional fittings. Choice of connections, screwed or flanged, in a wide choice of materials to ensure site compatibility. Customised flow scales Scale plates are customised to suit specific site requirements for fluid, reference temperature and pressure and flowrate units. Quality borosilicate glass tube - the inherent inert nature of glass eliminates the problems associated with plastic tubes, giving a long trouble free life. 60 Years of experience - proven design - for reliability. The Solartron Mobrey Group has been designing and manufacturing Rotameters for over 60 years and the simplicity of the principle speaks for itself. The 3 has Removable scales - owing different scales to be used for changes of fluid, up to scales can be affixed to a single unit to measure various fluids at different conditions. Should the fluid change at a later date, The Solartron Mobrey Group can produce new scales on production of the meter's serial number. With a 300mm scale length the 3 is easy to read. Carefully designed taper rates maximise float stability, ensuring that the reading resolution is optimised. Flowrate Alarms are available for signing both high and low flows and can be used in safe as well as hazardous areas, providing a very reliable and visual flowrate measurement and alarm. Most series 3 scales are produced using empirical data; this combined with the high tolerances used in manufacture ows tubes, floats or scales to be replaced in the field with no loss of accuracy and without replacement of three parts as a matched set. Rugged and yet lightweight design. Eliminates strain on the tube and provides excellent protection, while being light enough to be supported merely by the pipework. Avoiding the extra cost of w or bracket fixings. For behind panel (bezel) or w mounting ask about our Series 000.

Alarm options A range of flowrate alarms are available for use with the 3, most are latching ie. the relay status indicates whether the flow is above or below the switch point. Meters can be supplied with, or more sensors for high, low and intermediate switching. Sensor s S & S3 can be used with a power supply/ amplifying relay (S & S), whereas the S reed switch is an integral sensor and switch. Type S reed switch S photoelectric sensor S3 inductive sensor S power supply relay for S S amplifying relay for S3 Output Fluid s Float s Tube sizes Hazardous area use Temp -fluid -ambient Protection Switch rating Max voltage Max current Max power Power supply Power consumption Max. no. of sensors per tube Min. distance between sensors Specification sheet SPDT latching (Bi-stable) IA, DA, PA with magnet to Yes - with barrier* - to + 0 C - to + 0 C IP VAC/VDC A* 60VA / 30W resistive not required 6 0mm 0 V or I pulse or via S translucent No - to + 0 C - to + 0 C IP VDC** 0 ma** to VDC +% (via S) 0.6W max 3 0mm 33 current switching <3 or > ma or via S latching St Steel or PVC & 7 with S - to +70 0 C - to +70 0 C IP67 to VDC max ripple % 0.W nominal 6 0mm 67 SPDT translucent No - to + 0 C VAC 3A /0V+/-% /60Hz (via S) VA max SPDT latching (Bi-stable) as S3 as S3 [EEx ia/ib] IIB/IIC - to +60 0 C IP30 mm rail mount VAC A 0VA 0V -% +% -Hz (VAC or VDC optional) 3. VA nominal 6 Refer to specification sheets for further information. * Simple apparatus, maximum current 0.A for hazardous area use. ** S can be used without S, for current or voltage logic output. Sensor Mounting S S S3 Reed switch Code Photoelectric sensor Code Inductive sensor Code

Ordering information 3 Series 3 Rotameter Code End connections - state size e.g. ½" C C C C C C6 C7 C CX BSP.P cast iron BSP.P stainless steel. 3L BSP.P PVC PVC glued connection ( to PVC pipe - ISO 77 ) NP NFE03 3L stainless steel collar and loose epoxy painted carbon steel flange ANSI 3L stainless steel collar and loose epoxy painted carbon steel flange ISO 0 PN PVC flange Special construction Code Flow range and float (see flowrate chart) M-I to M-I Liquid stainless steel float M7-IA to M-IA Liquid stainless steel float + magnet (for alarm S) M-P to M-P Liquid PVC float M7-PA to M-PA Liquid PVC float + magnet (for alarm S) MG-D to MG-D Gas aluminium float MG-DA to MGDA Gas aluminium float plus magnet (for alarm S) MG-I to MG-I Gas stainless steel float MG7-IA to MG-IA Gas stainless steel float + magnet (for alarm S) M.. -x to MG.. -x For special flow rates consult sales Code Flow alarms S0 S S S3 S S Sx Not required Reed switch alarm (with float IA,DA or PA) Photoelectric alarm (without relay) Inductive alarm, stainless steel and PVC floats M to M6 Power supply relay for S Amplifying relay for S3 Special contact Code Z0 Z Z3 Z Z6 Z7 Z Z Z Z Options None Viton seals (Nitrile as standard) PVC seals (Nitrile as standard) PVC float stops (3L st st as standard) polycarbonate screen (Front only) polycarbonate screens (if no alarms fitted) nd scale plate, for different fluid/conditions Epoxy paint (Polyester as standard) Degreasing (for oxygen service) Customised scale (not as table opposite) 3 ½" C MG - IA S Z to m 3 /h - air 0 0 C 3 abs Example ordering code Please specify: Flow range, fluid details, density of fluid, viscosity, working temperature, working pressure.

Dimensions, Connections & Weight Tube size Connection Type L Dimensions (mm) H Ø P B J P N T E Weight kg Product data sheet 70 to & 7 & ½" BSP.P C,C & C PVC ISO 77 Ø0mm, C DN NP st st C6 ½" ANSI st st C7 PVC NP DN C " BSP.P C,C & C PVC ISO 77 Ø3mm, C DN NP st st C6 " ANSI st st C7 PVC NP DN C ½" BSP.P C,C & C PVC ISO 77 Ømm, C DN0 NP st st C6 ½" ANSI st st C7 PVC NP DN0 C " BSP.P C,C & C PVC ISO 77 Ø63mm, C DN NP st st C6 " ANSI st st C7 PVC NP DN C Parts. Painted aluminium chassis.. Connection - depending on model. 3. Painted aluminium end plate.. Flat seal (nitrile, viton or PVC).. Stainless steel disc. 6. Tube seal (nitrile, viton or PVC). 7. Float stop (stainless steel or PVC).. Stainless steel retaining screw.. Borosilicate glass measuring tube..painted aluminium graduated scale..float (stainless steel, aluminium or PVC). Instation and maintenance For satisfactory operation the following points should be considered : Inst the flowmeter verticy with the flow upward, keep it clean and avoid water-hammer. 6 6 76 0 6 60 60 60 30 30 30 30 30 3 3 3 3 3 3 3 3 3 3 33 33 33 33 33 6 3 66 7 7 3. 73 73 Dimensional drawings. 0 60.3 7...6 7...3.3.. 3. 7. 7. 6. 3 3 Spare parts The following spares are available, please quote the serial number in cases: - Glass tube - Float stops - Float - Scale plate - Seal kit Flanged connection Screwed connection KDG Instruments Crompton Way Crawley West Sussex England SL UE Tel: 0 Fax: 0 30 e-mail: sales@solartron.com www.solartronmobrey.com a Roxboro Group Company Head office: Solartron Mobrey Ltd, Edinburgh Avenue, Slough, England SL UE Tel: + 73 76600Fax: + 73 3 Bestobell Mobrey GmbH Deutschland tel: 0/ 0-0 Mobrey sp z o o Polska tel: 0 7 Mobrey AB Sverige tel: 0-7 0 00 Mobrey SA France tel: 0.3.30..30 Mobrey SA-NV Belgium tel: 0/ 37 Solartron Mobrey Ltd China tel: 0 63 Solartron Mobrey USA tel: () 3 0 abcdef The right is reserved to amend details given in this publication without notice 70 Nov 00