Purification of Brackish Water using Hybrid CDI-EDI Technology. by Robert Atlas, Aqua EWP, LLC. San Antonio, TX

Similar documents
Purification of Brackish Water using Hybrid CDI-EDI Technology

Concentration mg/l TDS mg/l 10, ,000 Recovery 75% Waste TDS mg/l 44,000 COD mg/l 3,500 0 BOD NTU 1,250 0 Power Used kwh/m3 2.

cost of ownership total cost ownership per year $764 $1,322 cost of ownership per m3 $0.87 $1.51 EWP is 42% less than RO

State-of-the-art Electrochemical Technologies for Industrial Water Treatment in the Kingdom of Saudi Arabia

Ion exchange membranes for water purification

NEXTGEN WATER TREATMENT SYSTEMS

Membrane Desalination Technology

PRESENTATION OF DESALINATION VIA REVERSE OSMOSIS

Copyright 2015 Saltworks Technologies Inc.

NOVEL WATER TREATMENT SYSTEMS

Water supplied by Marafiq does not meet the process requirements.

Lenntech. Tel Fax

Water Reuse/Recycle. Can this be Performed Economically in Today s Mills

Texas Desal 2017 NEXED EDR Technology Demonstration 22nd September Evoqua Water Technologies LLC

Overview. Commercial High-Purity Water Systems and Applications. Quality Water Is Our Business

Advanced water purifier system operation manual and setup guide

The Use of Electrical Energy in Brackish Water Desalination

RV AND TOWING EQUIPMENT

Producing ultra-pure water. electro-deionization

Water Treatment System

Nizar Kammourie. General Manager SAWACO Water Desalination. 5-7 November 2013 Abu Dhabi-UAE

How to Choose a Water Softener. Brought to you by

Use of Spiral Wound UF in RO Pretreatment

OsmoBC Integrated Membrane Systems

Engineering & Equipment Division

Nizar Kammourie. General Manager SAWACO Water Desalination November 2013 Abu Dhabi-UAE

ULTRA PURE SYSTEMS 75,150,200 GPD RODI INSTALLATION AND OPERATION MANUAL

5.B Generation of pharmaceutical water Author: Michael Gronwald Co-Author: Dr. Ralph Gomez / Up06

Summary of Pilot Plant Results and Preliminary Recommendations

Sonoran CryoDesal LLC Freeze Desalination: non-membrane desalination technology for difficult water / wastewater streams.

The Use of Electro-Coagulation Technology to Treat Hydrofracturing Flowback Water and Other Oil and Gas Field Wastewaters

Selective Removal Of Sodium And Chloride? Mono-Valent Selective Ion Exchange Membrane For Desalination And Reuse Enhancement.

OriginClear Water Treatment with Innovative Desalination Techniques High TDS Water Treatment for Oil & Gas Markets in Oman

Know What You re Monitoring! Since not all of us are water chemists, here is a brief understanding of what your different tools measure

VOLTEA S CAPDI TECHNOLOGY PRODUCT & SYSTEMS CATALOG

FS-8000 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product FS Date of purchase. Address

Closed-Circuit Desalination

Carden. CARDEN WATER SYSTEMS, LLC 3440 E. Broadway Phoenix, Arizona Water Systems. Industry Applications

A Water Solutions Company

REVERSE OSMOSIS WATER TREATMENT

selection of EDR desalting technology rather than MF/RO for the City of San Diego water reclamation project

IWC ZLD: New Silica Based Inhibitor Chemistry Permits Cost Effective Water Conservation for HVAC and Industrial Cooling Towers

Fresh Water Purification for Municipal Systems Global s Unique Modular Platform Systems

AL-KAWTHER INDUSTRIES LTD

Capacitive deionisation for inland brackish groundwater desalination: A case study

1000 GPD Marlin Reverse Osmosis Instruction & Owner s Manual

DESIGN AND OPERATION OF A HYBRID RO SYSTEM USING ENERGY SAVING MEMBRANES AND ENERGY RECOVERY TO TREAT SOUTHERN CALIFORNIA GROUND WATER.

advances in nitrate removal

RO System Design & CSMPRO v6.0 Program

The evolution of high purity water production

RO102 P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address RO102

NACE CORROSION 2008 TEG 096X Symposia - Paper 1421

NEW TECHNOLOGIES & BREAKTHROUGHS TO OLD DEIONIZATION APPLICATIONS

Collection and Treatment of Flowback and Produced Waters from Hydraulic Fracturing. Edwin Pinero Veolia Water North America

Purification of water using vertical multiple effect distillation unit

P URE PRO DRINKING WATER SYSTEM USER'S MANUAL REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

A Brief about Reverse Osmosis & Ultrafiltration!!

Municipalities Tap into Benefits of EDR Wat Treatme

Water Desalination and Its Techniques

Modutech S.r.l. WDS SEAWATER DROPLET SYSTEM FOR FRESH WATER SUPPLY. Ing. Alessandro Cariani

Advanced Water Treatment (DESALINATION) معالجة مياه متقدمة EENV 5330 PART 3. Page 1

FILMTEC Membranes. Tech Manual Excerpts. Principle of Reverse Osmosis. Figure 1: Overview of Osmosis / Reverse Osmosis

Q & A on Reverse Osmosis

Large Diameter Seawater Reverse Osmosis Elements A Year s Operation in Chile

Membrane Technology: From Manufacture to. May Production

Figure 1. Electrodialysis Stack Saltworks Technologies

WATER RECYCLING SOLUTIONS

Commercial Reverse Osmosis System

Ultrapure Hexavalent Chromium Treatment for Residential Supply

TREATING BRACKISH WATER IN SANDOVAL COUNTY FEBRUARY 19, 2010

Point of Use Reverse Osmosis and Electrodeionization: An Alternate to Service Deionization Jeff Tate, Agape Water Solutions, Inc.

About Spectra Watermakers Company Overview

NOTES P: 888-H2O-LOGIC ( ) F:

Water Quality and Filtration. Amphibian Ark

LANXESS Technical Training & Seminar. Reverse Osmosis & Ion Exchange Resin Applications

IONPURE CONTINUOUS ELECTRODEIONIZATION (CEDI)

Continuous Water Recycling For Reusable Plastic Containers

Solutions Industry pioneers in spiral membrane technology

Congratulations! Dear Customer,

S800-Direct Flow USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

Influent preheating (note that the heat will be recovered before discharge);

PREPARED BY KEN PANDYA AWTS, INC TRIPLE CROWN LN PLANO, TX OFFICE: APRIL 11, 2012

Sustainability in commercial laundering processes. Module 1 Usage of water. Chapter 3b. Water softening

Solving Water Problems

EC106M USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product EC106M. Date of purchase. Address

Bucking the Industry Trend. Simple Change to Water System Saves New Jersey Manufacturer $23,000 Annually

Water purification. Powered by solar energy. Contact. Address. Purification system designed by WMD Cedel B.V.

ElectroChemTM Advanced EDR

Pilot Study Report. Z-92 Uranium Treatment Process

Page 's to remove dissolved salts from water. Its main use was

Introduction of HR-800(M) Components. Cartridge filters. Installation diagram. Change membrane. Change filters. Operation regulation FAQ

Presented by: Jeff Freitag, The Water Guy Jon Tiegs, General Manager

Water for Instrument Processing

POREX Tubular Membrane Filter (TMF ) Applied in a ZLD System as Critical Solid/Liquid Separation Process

Overview of Desalination Techniques

EC106M-P USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product EC106M-P. Date of purchase. Address

ERS-106UV USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

Webcast August 9, R. Shane Trussell, Ph.D., P.E., BCEE Principal Investigator. Gordon J. Williams, Ph.D., P.E.

Design Parameters Affecting Performance

OPERATION AND MAINTENANCE MANUAL

Transcription:

Purification of Brackish Water using Hybrid CDI-EDI Technology by Robert Atlas, Aqua EWP, LLC. San Antonio, TX Abstract A new class of technology using capacitance based de-ionizer will be presented using all solid state electronics. The mechanism for ion removal during purification and waste water regeneration is very similar to a hybrid combination of Capacitive Deionization (CDI) and Electro deionization (EDI), This new version is called EWP X3 (patent pending). The technology uses a hybrid electrode comprised of activated carbon, nano materials and a semi-permeable coating. These hybrid electrodes still are electrically charged using a DC power supply and have different polarities. The minerals/metals in the water have polarity charges, which are attracted to the opposite polarity of the electrode, thus removing the minerals from the water. Case Studies will be presented on brackish water, brackish waste water and 5 year history on supply water. Each case study will show a water analysis before and after; including a characteristic of preferential removal for the primary pollutants of arsenic, fluoride, nitrates and Chromium to non-detect limits. One case study demonstrates an option to vary the operating conditions to adjust taste. Five years of longevity operating data will also be presented. Bio of Robert Atlas Robert Atlas is President of Aqua EWP based in San Antonio, Texas. Mr. Atlas is one of the primary and most significant developers of new emerging technology called the Electronic Water Purifier and a new battery device for hybrid transportation using the EWP technology platform. He is has a Bachelors in Chemistry from the State University of New York at New Paltz, a Masters in Chemical Engineering from Stevens Institute of Technology and also attended Baldwin Wallace EMBA program. For the last 10 years he has been involved with the purification and recycle of industrial waste water. In this span of time a new class of Capacitive Deionization has been developed sold under the brand name EWP. It pertains to all types of water and waste water purification including the desalination of ocean water for drinking water. Prior to the development of EWP, he worked for a subsidiary of US Filter in the area of water and waste water purification technologies. He also won product of the year award in 2003 from the San Antonio Chamber of commerce and has done more to advance the, manufacture, marketing and practical use of EWP for water purification on the world market than any other person operating in this technology space. In 2003 he commercialized the technology by inventing a semi automated manufacturing process for materials and cells. In 2006 he licensed the consumer products segment to another company. Today he is busy creating an automated process using robotics focused on meeting the growth in commercial systems. Mr. Atlas has one patent approved and another patent application submitted. He has made numerous presentations at conferences and has published over 12 papers associated with EWP technology.

Introduction Water. This is more important than food or fuel. The world's population is increasing while the worlds' water supply is not. There are only two frontiers left to supply water; either to purify the wastewater for recycle in industrial facilities or purify seawater. Neither of these frontiers have been conquered cost effectively with existing technology. For years membranes and ion exchange have been used to lower TDS from water and wastewater, none of which is economical, practical or efficient as TDS levels increase beyond 10,000 PPM. Availability of technology for low power consumption and powerful to purify the primary pollutants is not available in a single technology platform. In many parts of the world safe fresh water is not available to support the population, or that water will be the major economic, environmental, and political issue in the next century yet, this entire field is characterized by mature technology with manufacturers that refuse to embrace a disruptive technology. So the product cycles are measured in decades by the consumer. But a new technology has been developed such as the Electronic Water Purifier (EWP) over the last 10 years that has low operating costs, low rejection waste water, low capital, no chemicals, small footprint and is now from POU to in large commercial sizes. This technology will challenge traditional technologies. EWP X3 is classified in a technology space called Capacitive Deionization (CDI). CDI has been around since 1950. The basic concept for separating compounds that are dissolved in water using electrical means is quite old. The technology started to be refined in a 25 year period from 1980 by approximately 12 inventors. It s just that EWP X3 is now refined with the most installed systems (1,000+) of any of the inventors in consumer, commercial and industrial applications. Myths of CDI 1. CDI is not been around a long time, not been fully developed and thus a risk. Of course this is not true. CDI has been fully developed for at least 5 years because we have longevity data from existing installations. 2. Electricity and water must be dangerous. If current used unit of area is usually measured in milliamps and no electrical charge appears in the water only across the electrodes. 3. It can t soften water and remove the primary pollutants simultaneously. The fact that the technology reduces total dissolved solids fairly linearly means that it removes all the ions in the same way. While it has a slight preferential removal for some components, the mean deviation from average is only +/- 7%. 4. Why is the capital cost so much higher than RO? In fact on a feed flow basis when evaluating for 2,500 ppm feed, EWP is +/- 20% on capital, far less on operating costs, very little maintenance. Capital costs will be similar and operating costs less with greater benefit to the consumer. 5. CDI is not effective for removing primary pollutants

EWP removes more contaminants than any other single technology on the market. 99.5% removal of some primary pollutants Nitrates Ammonia Perchlorate Arsenic Fluoride Chrome Iron (less than 10 ppm feed) Organic Acids (e.g. Humic and Tannic Acid) 6. CDI can t be cost effective for large systems The flows can increase in multiples of 5 gpm with development of a modular cell pack and power supply 5 GPM System Picture of 5 gpm cell pack power supplies

Benefits All solid state electronics, no parts to wear out or maintain High recovery of 80+% No chemicals, no membranes or media to replace Cost effective on capital. Low operating costs Small footprint (half the size of RO) Removes the primary pollutants better than any other single technology Small POU. POE sixes to large commercial systems Very simple to maintain How does EWP X3 Work? Various Dissolved salts and Silica in water are the major components of TDS (total dissolved solids). These dissolved salts need to be removed on many applications, or they will form deposits. Ultimately this will affect equipment performance, safety and taste of the water. (Figure 1) Figure 1 Figure 2 Figure 3 The Electronic Water Purifier makes patented technology available to generate highly purified quality water by removing these dissolved salts electronically. Electrodes used are made from activated carbon that has a coating and a conductive material. When these electrodes are layered using a DC power supply, the individual electrodes are charged with different polarities. The dissolved salts in the water have polarity charges and are attracted to the opposite polarity of the electrode, thus removing the dissolved salts from the water. These dissolved salts are adsorbed though a process we call electrochemical diffusion through the coating and onto the activated carbon electrode surface creating the pure water. (Figure 2) When sufficient dissolved salts are deposited on the electrodes, the electrodes are regenerated initially by shorting the electrodes to ground. The contaminants fall off the electrode in the same chemical form as was removed. After the regeneration, the waste at 2 times the original concentration is discharged through a valve. The waste is discharged to a drain. (Figure 3) Upon completion of this cycle, the polarities are reversed for normal operation.

General Operating Characteristics of Capacitive De-ionization 1. The faster the flow, the less average purification 2. The electrodes are one pass and made from activated carbon and are not made from any aerogel material which has to use serpentine flow because of its inefficiency to purify and regenerate 3. If flow is increased by 50% the decrease in average purification will be 10%. This might be an acceptable trade-off. 4. If the feed salinity increases above where you start, the percent purification (or the outlet TDS will increase from where you started. Figure 4 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% Small Cell Metrics revised 2007 % Purify vs. Feed Salinity 0% 0 5 10 15 20 25 concentration ms 5. For every 1,250 ppm in feed salinity, another cell in series is needed to maintain high levels of purification One can see from Figure 4 that at 1,000 ppm the purification is 80% (200 ppm) and at 2,500 ppm the purification 65% (875 ppm) To achieve a purification of less than 500 ppm there are 2 choices: either 1) the flow has to decrease to achieve a higher purification This means the capital investment is higher because the total daily flow output will be less; or 2) the alternative is to maintain constant flow by adding another cell in series--perhaps flow at a higher flow speed. Figure 5 shows the effect of adding cells in series to maintain the rated flow per cell. Figure 5: Adding Cells in Series to maintain purification

Percent Purification 100% 95% % Purification 90% 85% 80% 75% 70% 0 1000 2000 3000 4000 5000 6000 Feed Water TDS (ppm) 6. The power consumed is small. Figure 6: Power Consumption 1.4 1.2 1 0.8 0.6 0.4 0.2 Small Cell Metrics revised 2007 Power Consumer kwh per 1000 gallons of feed water 0 0 5 10 15 20 25 concentration ms 7. Any contaminant that will absorb into activated carbon will absorb in the electrode such as petroleum hydrocarbons, alcohol etc... And will take away surface area for ion exchange. The exception is organic substances that completely dissociate in water 8. Freezing should not damage the electrode. 9. recovery can be set to 80% to 85% by throttling a manual valve after the waste water discharge valve. This is possible because the purification flow rates are extraordinarily high and the waste flow per gram of carbon can be less. This will decrease the volume of waste water discharge and will also increase the concentration during the initial purification stage which will decrease the amount of purification slightly. The recovery can be set high because of the high flows used during purification. Figure 7 shows the relationship in flow per gram of carbon in the electrode.

Figure 7: Comparison of various materials and flow rate Type of Material Flow Rate Aerogel 2 to 4 CDI 4 to 8 EWP X3 15 to 20 (ml/min/gram of carbon) 10. For mineral deposits left on any of the cell surfaces, a mild acid such as citric acid can be used to restore performance to the original factory standards. Process Description The new class of EWP is called X3 because the technology has evolved to use 1) a capacitive deionization principal to remove dissolved ions from water, but also emulates EDI where 2) a semi-permeable membrane and electrode are use. The device consists of multiple layers including chargeable coated electrodes or layers that work in response to an applied DC potential above 1 VDC nominally. Each electrode on the device contains a conductive surface sandwiched between layers of activated carbon. A non-conductive spacer material separates the plates from each other. These electrodes are alternately connected to the two sides of a DC power supply via appropriate connecting leads. The device works on the principles of capacitive deionization to purify water, with the application of a low voltage DC potential to attract and discharge ions on the electrode surface. The high surface area carbon electrode layers attract and hold ions from a solution on its surface, flowing through the device. The positive ions are attracted to the negatively charged plate (anode), and the negative ions are attracted to the positively charged plate (cathode). Eventually, all the charged sites are filled and the device must then be regenerated by discharging the irons from the electrode surfaces. shorting of the electrodes and reversing the polarity of the applied DC potential. Once a substantial amount of the new displaced ions are flushed into the waste stream, after a length of time, the unit begins to charge once again by attracting ions from the feed solution under the influence of the reverse potential. This action then begins a reversible service cycle. What makes this device different that any CDI or EDI on the market today is 3 different flow mechanisms. The electrode and semi-permeable coating are not in contact with each other and it doesn t use chemicals to regenerate like EDI. The flow can be along the spacer, diffusion between the semi permeable coating and electrode and between the semi permeable coating and electrode. This results in shorter regeneration times (more purified water daily), faster flush with a greater concentration of contaminants in the waste water and 25% less power consumption.

Figure 8: Cell Construction Diagram Flow Out - 1 VDC + Flow In Conductor Spacer Electrode Example 1: Waste Water Example in Coal Bed Methane During the field test we demonstrated that the water could be purified to the acceptable discharge Standards. A TDS of 270 ppm can be achieved from a starting feed water TDS 2,500 with 85% recovery and with blending an SAR of 1 can be achieved. Over a 10-year span the total cost of capital and operations will be $.05 per barrel of water processed. A test was run at flows of 5 gpm with two 5 gpm systems in series. Solids were filtered using a 30 micron filter. We achieved the following results: Figure 9: Results of CBM test Feed Conductivity 2,500 ppm Estimated Feed SAR 24 Purified Effluent 270 ppm SAR (Sodium Absorption Ratio) 3 Waste Water (reject) conductivity 5,750 ppm % Purification average 90% Recovery 85% Power Consumption 4.0 kwhr/1000 gal 30 GPM

Example 2: Cycle Testing for Supply Fresh Water Much testing has been done on San Antonio City Water for over 5 years Figure 10: 5 year Test on POU device 55 System long term testing EWP in water cooler application -- San Antonio City Water (525 us) 50 conductivity us 45 40 35 updated with new power supply and EPROM board design 30 0 500 1000 1500 2000 days in service The only maintenance is a citric acid cleaning twice annually. Example 3: Arsenic Test May 2006 A unit was installed at a house in New Hampshire on well water. This family had been following our technology for years and was purchasing 2 gallons of bottled water because they had Arsenic and Nitrates in their well water. Finally a Water Genie was installed under their kitchen sink. They did their own installation. This test was run on a 20 gram cell that flowed at 300 ml/min (<50 GPD). The results show a high removal of Arsenic, Nitrates and Fluoride. The flow was adjusted to leave enough minerals in the purified water to give an acceptable taste. Figure 11: Arsenic and Fluoride Testing on POU Device Before After reduction mg/l mg/l TDS 260 63 76% ph 7.75 6.8 13% Turbidity 0.5 0.5 Anion Chloride 7.44 3.7 50% Fluoride <.1 Non detect 100% Nitrate (as N) 3.44 Non detect 100% Nitrate/Nitrite (as N) 3.44 Non detect 100% Metal Analysis Copper <0.010 Non detect 100%

Iron <0.010 Non detect 100% Manganese <0.010 Non detect 100% Sodium 3.39 1.84 46% Hardness 181 44.4 76% Calcium 42.5 9.13 79% Magnesium 18.2 5.24 71% Arsenic 0.039 Non detect 100% The customer says I believe the basic technology in the EWP unit is sound. The results of sending my well water through the unit are what I was looking for when I first contacted you about purchasing a unit..i have been able nearly duplicate the quality of water we used to buy from Poland Springs, a well know spring water provider here in New England. The unit removed the potentially dangerous arsenic and nitrates in the water, and left some of the calcium which helps the water to taste good. I feel like we are making our own 'spring water' right here in our home! With the flow setting we are using now, we can make all the drinking water we need for a day in less than an hour. The reason I was interested in buying this unit in particular, rather than a water softener which uses salts, or a reverse osmosis system, is that the EWP unit has significantly lower operating costs, as far as I can tell. The Reverse Osmosis systems require you to replace expensive filters at least yearly or perhaps more often. The water softener systems require you to buy salt and keep the brine tank properly filled. In addition, more and more states are putting limitations on how you have to deal with the salts from water softeners, especially when you have a septic system, as I do. The EWP unit puts back in the waste water only things it took out of the supply water, plus a little citric acid cleaning every now and again for preventative maintenance cleaning, Example 4: Perchlorate Testing Figure 12: The test results are as follows on POU RO vs. POU EWP RO EWP Permeate (Purified water) Flow 110 ml/min 250 ml/min Reject (waste water) flow 920 ml/min 129 ml/min % Waste of Total flow 89% 66% TDS of feed water 340 mg/l 340 mg/l TDS of purified water (Permeate) 102 Mg/l 22 Mg/l % Purification 77% 94% Sodium Perchlorate in feed water 1.0 Mg/l 1.0 Mg/l Sodium Perchlorate in Purified water 1.0 Mg/l and Mg/l (Permeate) % Sodium Perchlorate removed 0% 100% The sample water was spiked with Sodium Perchlorate at 1 mg/l then tested. 100 liters sample was created for testing. The perchlorate level was measured using an external analytical testing source. TDS was measured using an electronic conductivity meter. The EWP outperformed RO on Removal of sodium perchlorate, purified water quality and the amount of wastewater.

Example 5: 6,000 PPM Brackish Water A four stage system was built to purify 6,000 ppm brackish water to less than 750 ppm for household use. Figure 13: Results of Brackish Water Test Feed TDS 6,000 ppm Effluent 750 Ppm Recovery 70% Power 18 kwh/1000 gal This system uses 4 cells in series. Purifies In series and flushes in series Cartridge filter with internal SV0 ball valve Process Flow Diagram for series flow (purify and waste) SV1 effluent UV (optional) Tank Tank feed SV2 waste pump variable speed pump M Electrode waste Tank Electrode Sabrex, Inc. P & I D Electronic Water Purifier EWP 2 stage 8/2005 R.Atlas Summary The EWP X3 has developed into a range of consumer products for POU and POE as well as large commercial systems starting at 5 gpm and can be expanded to much larger flows. The technology has proven to be cost effective, low maintenance while removing a broad range of contaminants. It is starting to challenge the use membranes and media in many applications all over the globe. 11