International Water Standards

Similar documents
INTERNATIONAL STANDARDS ON FLUID PREPARATION FOR CONVECTIVE THERAPIES. Richard A. Ward, Ph.D.

AQUAboss PURITY FOR LIFE

AQUAsystem PURITY FOR LIFE

Dialysis water purification

Water treatment in dialysis technology

Water treatment system and water quality Standard, Configuration and Practical Considerations

Appendix: Water purification methods

Dialysis water purification

photo: Ameriwater.com Dialysis Water Treatment Equipment Monitoring December 2017 Developed by the BCPRA Hemodialysis Committee

Phoenix OneDS. Water treatment for dialysis

The Hygienic Chain. How to optimize dialysis fluid purity

PURIFIED WATER DESIGN

Manual 042 Water Quality Standard

Protegra CS RO Series. Meeting All Your Pure Water Demands. Water Technologies

Water Production for Pharmaceutical Manufacturing: Looking Beyond Compliance at the Entire Manufacturing Process

Ensuring reliable, consistent production in pharmaceutical water systems

USP Perspective on Pharmaceutical Waters. Antonio Hernandez-Cardoso, M.Sc. Senior Scientific Liaison September 7, 2017

ISO INTERNATIONAL STANDARD. Water for haemodialysis and related therapies. Eau pour hémodialyse et thérapies apparentées

Water Based Critical Utilities. RO, WFI, and Steam

Medical pure water treatment system. Chongqing Molecular Water System Co., Ltd

[ DWA Media Supply Systems ] Functional solutions with exclusive design DWA

Water for Dialysis Part 1: Components

WATER PREPARATION FOR DIALYSIS

Water for Instrument Processing

AQUINITY 2 & ASTACUS 2 INNOVATIVE ULTRA PURE WATER SYSTEMS

Compounding Pharmacies and Water

LABORATORY & DEIONIZED WATER SYSTEMS DESIGN AND CONSTRUCTION STANDARD

Evolution of AAMI/ANSI Standards: Harmonizing with ISO. V. Taaffe 2018

Purite Water Purification Systems

Regulation. Code of Federal Regulations in the United States. Chapter 1 Title 21 CFR is the title for pharmaceuticals.

rios Water Purification system The standard for laboratory-grade water

ISO INTERNATIONAL STANDARD. Water treatment equipment for haemodialysis applications and related therapies

CMS, FDA and AAMI Requirements for Bicarbonate Systems Made Simple. Compiled January 2012 by AmeriWater Incorporated

European Hygienic Engineering & Design Group

DIALYSIS WATER TREATMENT DIALYSIS PROCESS WATER SOLUTIONS THE PREMIER PROVIDER OF WATER TREATMENT SOLUTIONS TO THE DIALYSIS INDUSTRY

5.B Generation of pharmaceutical water Author: Michael Gronwald Co-Author: Dr. Ralph Gomez / Up06

GUIDE TO INSPECTIONS OF HIGH PURITY WATER SYSTEMS

VALIDATION AND QUALIFICATION OF WATER PURIFICATION, STORAGE, AND DISTRIBUTION SYSTEMS

SMF WATER SYSTEMS. (PIC/S July.2004) By Anand Kuptamatee Thai FDA Conference September 19-21, 2005

Water treatment equipment for haemodialysis applications and related therapies

Pharmatec GmbH Units for the Production, Storage and Distribution of High-purity Media. Lorem ipsum dolor sit 3

PRODUCTION OF PW/HPW/WFI AND USP/EP REQUIREMENTS. Erez Eilam F&U Area Lead Novartis Singapore Bio production Operations

IMEC. March PW & HPW Generation

CENTRALIZED SYSTEMS CENTRA. Packaged central laboratory water systems. The Laboratory Water Specialists

ISO INTERNATIONAL STANDARD. Quality of dialysis fluid for haemodialysis and related therapies

water purification system

Purified Water Systems

CENTRALIZED SYSTEMS CENTRA. Packaged central laboratory water systems. The Laboratory Water Specialists

Water supplied by Marafiq does not meet the process requirements.

[Previous Chapter] [Table of Contents] [Next Chapter]

adrona Crystal E series Crystal E Ultrapure Crystal E HPLC Crystal E Bio Crystal E Pure Water purification systems

Draft agreed by Quality Working Party 7 June Adopted by CHMP for release for consultation 28 June 2018

Systems. Barnstead MIX AND MATCH...WITH BARNSTEAD YOU HAVE A CHOICE

PROVINCIAL STANDARDS & GUIDELINES

OVIVO PHARMACEUTICAL SOLUTIONS SOLUTIONS FOR PURIFIED WATER, HIGHLY PURIFIED WATER AND WATER FOR INJECTION.

REVERSE OSMOSIS WATER TREATMENT

PURELAB CHORUS SYSTEMS

Condition: Water & Dialysate Quality. Glenda Payne, RN, MS, CNN

Annex 2. WHO good manufacturing practices: water for pharmaceutical use 1

OSMOTRON PRO. Professional Process Management for Your Production

WFI New Ph Eur Selecting the best production option. Gordon Farquharson, July 2016

Ultrapure Dialysate Present & Future Impact on Biomed Techs

Submission of comments on ' Q&A on production of WFI by non-distillation methods - RO and biofilms and control strategies' (EMA/INS/489331/2016)

MULTITRON VAPOTRON COMBITRON

Overview. Commercial High-Purity Water Systems and Applications. Quality Water Is Our Business

Elix Gulfstream Clinical Water Purification System

Integrated Process Engineers & Constructors, Inc.

PURELAB Chorus 2 Innovation and Flexibility

U-Version. Incoming City Water

Fully Comprehensive Premium Range

Water Solutions for the Pharmaceutical Industry

WHO GOOD MANUFACTURING PRACTICES: WATER FOR PHARMACEUTICAL USE PROPOSAL FOR REVISION DRAFT FOR COMMENTS

GAMP 4/5 Prospective / retrospective Qualification of water treatment plants) P. Dony

General. What is ADVOS and what is ADVOS multi? ADVOS is an abbreviation for Advanced Organ Support.

More than 10 years in Ultrapure Water System Manufacture, we are going with you in your high water quality demand better understanding in service

Laboratory Water Three water qualities One clear solution

Technical Challenges and Solutions to Pharmaceutical Water System Testing during Validation and Operation

PRIMARY GRADE WATER L A B W A T E R. PURELAB TM Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists

Flow Measurement with FLOWave flowmeters in clean utility applications. Presentation National GMP & Validation Forum

Validation. An Easy to Understand Guide Validating Purified Water Systems

Guidance for the Content of Premarket Notifications for Hemodialysis> Delivery Systems

NovAseptic Connectors. The Right Connection for Your Systems

Cold WFI in Best Quality. generate, store and distribute wfi. bwt-pharma.com

REVERSE OSMOSIS SYSTEM USER'S MANUAL. Excellent Product, Excellent Water! My PurePro X6

Clinical Practice Standards and Procedures for Dialysis Water Quality: 3: Chemical Analyses of Dialysis Water

AQUINITY 2 & ASTACUS 2 INNOVATIVE ULTRA PURE WATER SYSTEMS

Preparation of Reagent Water

Producing ultra-pure water. electro-deionization

Water purification solutions

Steam Sterilizer. SA Series. for hospitals, CSSD and medical centers

Purified Water Systems

Christ Water treatment plant K-401 Code No.: EIN

GMP WORKSHOP. WATER for Pharmaceutical Use

Audit of procedures for monitoring the quality of water used in the preparation of dialysis fluid in adult haemodialysis units in Scotland 2015

PURE-PRO REVERSE OSMOSIS SYSTEM

Mar Cor Purification. Carbon Block Filtration System. Operation & Maintenance Manual

BIOFILM THE NOW. An Ounce of Prevention is Worth a Pound of Cure

Presented by Dr. Richard Ward A Webber Training Teleclass, March 11, 2004

GROUP. Water Purification Solutions for Healthcare Providers

HaemoDialysis: New Technology. Peter G Kerr Monash Medical Centre and Monash University Clayton, Vic, Australia

Transcription:

International Water Standards How they effect the design of a water treatment Dr. Stephan Krietemeyer Lauer Membran Wassertechnik GmbH Industriegebiet Speichermatt D 79599 Wittlingen 1 //KR

International Water Standards What are the applicable standards in Canada and Europe? In what way are they different? What equipment is needed to comply with the standards? 2 //KR

Specific standards for water and water treatment for HD and related therapies Canada Europe Z364.2.2-03 ERA/EDTA 26722: 2009 CD 23500* Design Z364.2.2-03 ERA/EDTA EDTNA CD 23500* *CD status 10/09 Operation Z364.2.2-03 Ph. Europe ERA/EDTA EDTNA National 13959: 2009 Product quality 3 //KR

Regulatory Background Canada (MDR) RO Systems: Medical Device Class 3 (MD Licence required) Heat Disinfection: MD Class 2 (MD Licence required) European Union (MDD) Medical Device Class IIb (MD Licence required) MD Class IIa (MD Licence required) 4 //KR

Specific Standards Canada European Union Q.- System ISO 13485 Q.- System ISO 13485 CSA Z364.2.2-03 Water Treatment Equipment and Water Quality European Pharmacopoeia and National standards CAN/ CSA C22.2 No. 601.1 EN 60601-1-2 2 (2006) for EMC CAN / CSA C22.2 No.61010-1 Safety Requirements for Electrical Equipment EN 61010-1 1 (2001) Safety Requirements for Electrical Equipment 5 //KR

Microbiological parameters Ph. Europ. (2009) ERA/EDTA (2002) ISO 13959 (2009) CSA Z364.2.2 (2003) HD: CFU/ml < 100 <100 (25) <100 (50) <100 (50) UP: CFU/ml < 0.1 (HP water) < 0.1 HD: IU/ml < 0.25 <0.25 (0.125) UP: IU/ml < 0.03 (HP water) < 0.03 < 0.25 (0.125) <2.0 (1.0) HD: Hemodialysis; UP: Ultrapure water/ highly purified water 6 //KR

Water Treatment Modules Pre treatment UF Steam Ring Main Heater 90 C C RO RO 1 RO 2 Conductivities < 2µs/cm 2 (1TDS) require permeate- staged RO systems. Heat disinfection of the ring main became a standard for automated sanitization. Heat disinfection of the RO was a further development Depending on local preferences UF is a common process step. Ring main DI with steam has already been realized in various installations. 7 //KR

Water for hemodialysis Basic configuration: 1. Pre-treatment (carbon, softener, particle filter) Pre treatment RO 1 Ring Mian 2. Single staged RO 3. Ring main The basic configuration of a water treatment and distribution system provides water for hemodialysis. 8 //KR

Permeate staged RO systems Double membrane barrier 2 x 100% redundancy Avoids bacterial growth of standby RO Second RO w/o water losses Direct feeding 9 //KR

Endotoxin Permeate staged RO Total number of samples 200 180 160 140 120 100 80 60 77,03% 87,63% 92,23% 96,47% 97,88% Frequency Total % 98,23% 100,00% 90,00% 80,00% 70,00% 60,00% 50,00% 40,00% 30,00% Average: 0,027 IU / ml Standard deviation: 0,045 IU / ml # samples: 283 40 20 0 10,60% 0,005 0,020 0,051 0,096 0,157 0,202 0,233 greater 0,233 Endotoxin classes [IU/ml] 20,00% 10,00% 0,00% 10 //KR

General design requirements All inner surfaces must be smooth and w/o grooves to prevent bacterial growth (Stainless steel, PVDF). All water contact materials must not change their physical properties or chemical characteristics during DI. No leach out. High velocity and low temperature during operation to prevent bacterial growth. 14 //KR

Design requirements for UP water Direct feed Storage tanks should be avoided Polisher (Second RO, EDI). High shear stress, small diameters, high flow rates. Avoid dead space and lateral arms ERA / EDTA (2002) 15 //KR

Pipe disconnection to avoid retrograde contamination Air gap To avoid a retrograde contamination of the dialysis machines from the drain an air gap is strongly recommended 16 //KR

Hidden dead spaces Throughout the installation ball valves must be avoided. Due to their design these valves cannot be dead space free. 17 //KR

Hidden dead spaces The design of a compression fitting includes dead spaces. 18 //KR

Sterile clamps and fittings Sterile clamps and fittings minimize bacterial growth in the ring main. 19 //KR

Professional sampling methods Easy access to the sampling ports. Sampling ports are integrated in the sanitization process 20 //KR

Dead leg free ring mains Permeate circulates through the ring main to the point of use. High velocity / shear forces (0.5 1 m/s) Ring main shall not affect permeate quality in any way. Material and design must follow the same design guidelines as they are valid for the RO. 21 //KR

Water distribution system Materials of the distribution system that contact the purified water shall not interact chemically or physically so as to affect the purity or quality of the product water adversely. 22 //KR

Water distribution system Most common materials for distribution systems in Europe are : PVC ( inexpensive, embrittles,, not heat resistant) Stainless steel ( complex installation, dead space free, heat resistant up to 120 C, Standard in pharmaceutical industry) PEX ( Easy to install, heat resistant 90 C; compression fittings with dead spaces) PVDF ( complex installation, dead space free, heat resistant up to 90 C, Standard in semi conductor industry) 23 //KR

Secondary loops Tubing between ring main and HD machines must be integrated in routine disinfection. Secondary ring mains eliminate dead legs between the main loop and the HD machine. 24 //KR

25 //KR

26 //KR

Endotoxin measurement ring main return 200 180 92% 95% 97% 99% 100,00% 90,00% Average: 0,032 IU / ml Total number of samples 160 140 120 100 80 60 69% 80% 84% Frequency Total % 80,00% 70,00% 60,00% 50,00% 40,00% 30,00% Standard deviation 0,047 IU / ml # samples 283 40 20,00% 20 10,00% 0 0,015 0,046 0,061 0,106 0,152 0,197 0,213 greater 0,213 Endotoxin classes [IU/ml] 0,00% 27 //KR

Prevention of biofilm Thomas Griebe (1998) Mercator Universität Duisburg Thomas Griebe (1998) Mercator Universität Duisburg Automated heat disinfections of the RO and ring main minimize growth of biofilms. 28 //KR

Heating process diagram RO Standby Heating 15 30 min. 90 C C max. PHD 1 1 min. 3d 70-90 C Heat DI RO Emergency Cooling Inline 1 1 min. 3d 70-90 C Active cooling PHD 2 1 min. 3d 70-90 C Inline 2 1 min. 3d 70-90 C Cooling 15 30 min. <37 C Passive cooling 4 C C / h 29 //KR

30 //KR

Temperature profile of RO heating cycle 31 //KR

Flown-through inline heater 32 //KR

Permanent Hot Disinfection (PHD) 80 C 35 C 10 C Monday Tuesday Wedneday Thursday Friday Saturday Sunday 33 //KR

Permanent Hot Disinfection (PHD) 80 C 35 C 10 C Monday Tuesday Wedneday Thursday Friday Saturday Sunday 34 //KR

Sterile Filtration UF Ring Main Heater 90 C C RO Pre treatment RO 1 RO 2 35 //KR

Sterile Filtration Pharmaceutical grade sterile filtration. Loop integrated. Heat and steam resistant Pharmaceutical grade sampling valve. Sterile clamps. 36 //KR

10 min @121 C C? Steam UF Ring Main Heater 90 C C RO Pre treatment RO 1 RO 2 37 //KR

10 min @121 C! Only DSF / stainless steel ring mains are qualified for steam sterilization (121 C; 10 min). Ring main installations must comply with EC Directive 97/23/EC (Pressure( Equipment Directive (PED) or other applicable national standards. 38 //KR

Steam sterilization of ring main Upon installation stainless steel ring mains can be equipped with additional steam traps and drain fittings. Installation must comply with pharmaceutical GMP standards for steam sterilization. 39 //KR

Temperature profile sterilization 40 //KR

Water room 41 //KR

Summary Whilst it is not possible to predict what the standard for dialysis-quality water will be in the future, it is likely that the maximum allowed levels of bacteria and endotoxin will be reduced. First international standards reference UP water quality. 42 //KR

Summary Regulatory Requirements for Medical Devices in Canada and Europe are similar. Different water treatment modules can be combined individually to match recent and future quality requirements for water for hemodialysis or ultrapure water. 43 //KR

44 //KR

CSA Z364.2.2 Water treatment equipment and water quality requirements for hemodialysis acute, chronic, and home-based hemodialysis; water for preparing dialyzing fluid and concentrate for hemodialysis; all water intended for contact with the dialyzing fluid pathway; the baseline quality of the feed water and any other input water; water treatment and monitoring equipment; water distribution systems; and product water used for flushing blood pathways before sterilization (but not afterwards). 45 //KR

European Pharmacopoeia 01/2009:1167 Monograph is given for information. Analytical methods described and the limits proposed are intended to be used for validating the procedure for obtaining the water. 46 //KR

ERA/EDTA: Sect.IV Dialysis fluid purity Nephrol. Dial. Transplant: : 2002 17 [Suppl.7] 45-62 IV.1 Water treatment system IV.2 Technical design of water treatment system IV.3 Monitoring and maintenance IV.4 Haemodialysis proportioning machine IV.5 Electrolytic concentrates IV.6 Dialysis fluid purity: Implications in the haemocompatibility network system 47 //KR

EDTNA/ERCA Guidelines Section 3 (Technical( Technical) ) Sept. 2001 Guidelines apply to the control and monitoring of: Water used for preparation of dialysis fluid in all settings, including patients homes and acute care units Water used for in-house production of liquid concentrates Water used for reprocessing dialysers Water used for preparation of ultrapure dialysis fluid by equipment fitted with additional point-of ofuse filtration 48 //KR

ISO 26722: 2009 Water treatment equipment for haemodialysis and related therapies ISO 26722:2009 is addressed to the manufacturer and/or provider of water treatment systems and/or devices used for the express purpose of providing water for haemodialysis or related therapies. 49 //KR

ISO 26722: 2009 Water treatment equipment for haemodialysis and related therapies All devices, piping and fittings between the point at which potable water is delivered to the water treatment system and the point of use of the dialysis water. Examples of devices are water purification devices, online water quality monitors (such as conductivity monitors), and piping systems for the distribution of dialysis water. 50 //KR

ISO 13959: 2009 Water for haemodialyis and related therapies Specifies minimum requirements for water to be used in the preparation of concentrates, dialysis fluids for haemodialysis, haemodiafiltration and haemofiltration and for the reprocessing of haemodialysers. Does not address the operation of water treatment equipment nor the final mixing of treated water with concentrates to produce the dialysis fluids used in such therapies. That operation is the sole responsibility of dialysis professionals. Does not apply to dialysis fluid regenerating systems. 51 //KR

ISO 23500 family of standards ISO 23500: Guidance for the preparation and quality management of fluids for hemodialysis and related therapies ISO 11663: 2009 Quality of dialysis fluid for haemo- dialysis and related therapies ISO 13958: 2009 Concentrates for haemo- dialysis and related therapies ISO 13959: 2009 Water for haemodialysis and related thearapies ISO 26722: 2009 Water treatment equipment for haemodialyis applications and related therapies 52 //KR

CD / ISO 23500 Guidelines for the user / operator. Covers design, installation, operation and validation of water treatment for hemodialysis and related therapies 53 //KR

ISO 23500 Microbiological parameters for dialysis fluids Microbiological parameters for ultrapure dialysis fluids and substitution solutions (ISO 11663) Validation of system performance Strategies for microbiological control Critical aspects of system design 54 //KR