ENKASONIC FLOOR UNDERLAYMENT 9110

Similar documents
Floor Insulation Underlayment Section Sound Control Matting

PLYWOOD FLOATING FLOOR

1. The subfloor must be structurally sound and able to withstand live and dead loads with a deflection limitation of L/360.

Acoustic Treatment

Product Guide Specification Pliteq GenieMat FF06, GenieMat FF10, GenieMat FF17, GenieMat FF25, GenieMat FF50, GenieMat FF75

DIVISION 9 - SECTION ECOSilence Recycled Rubber Sound Underlayment US Patent No. RE 41,945

QT 4003 (3mm), QT 4005 (5mm) & QT 4010 (10mm)

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

BENJAMIN OBDYKE INCORPORATED

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

SPECIFICATION GUIDELINE

SECTION GYPSUM BOARD ASSEMBLIES

SECTION INSULATED CONCRETE FORMS - RASTRA 1.01 SUMMARY

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

SPECIFICATION GUIDELINE

SECTION WOOD STRIP FLOORING

FIRM-FILL SCM-400 can be installed under a FIRM-FILL Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system.

ACOUSTICAL WALL TREATMENT SECTION 09840

FLOORING TREATMENT

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

BENTONITE WATERPROOFING

SECTION Fiber Reinforced Stucco 1

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

SECTION GYPSUM BOARD

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

SECTION SELF-ADHERING SHEET FLASHING

DIVISION 9 - SECTION QTscu Recycled Rubber Sound Underlayment US Patent No. RE 41,945

RESILIENT SOUND ISOLATION CLIPS

Sept 30, 2004 Page 1

PAVING SLABS ON AGGREGATE BED FOR ROOF PLAZA DECKS

Product Guide Specification Pliteq GenieMat RST-02, RST-05, RST-10, RST-12, RST-15

UNDERLAYMENT INSTALLATION INSTRUCTIONS

SECTION TILING

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

The original. insulation.

When demanding consistent quality, specify FIRM-FILL SCM-250 to assist in achieving highly improved IIC sound performance in multifamily

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

SECTION STRUCTURAL INSULATED PANELS

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

DIVISION 9 - SECTION QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945

SECTION CERAMIC TILE. B. Ceramic tile wall finishes including standard and custom designs.

SECTION RESILIENT SHEET FLOORING

Soundmaster & Modernfold TECHNICAL DATA

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SOUND & VIBRATION CONTROL FOR BUILDINGS. ISO-SEP 25HD High Dimple Rubber Isolation Mat Specification

A. Description of Work: Work of this section includes self leveling underlayment for interior finish flooring but is not limited to, the following:

CONCRETE TILE PAVERS

HAWORTH PORCELAIN FLOORING SYSTEM CSI Specifications 03/29/2017. A. Concrete work and concrete floor sealer is specified in Section

Armstrong Flooring Installation Accessories

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

SECTION RESILIENT ATHLETIC SURFACING. B. Related Sections: Section(s) related to this section include:

Mats Inc. Installation Instructions for Extreme Traffic Wall-to-Wall Carpet Matting 9800

SOUND REDUCER INSTALLATION MANUAL. Manufactured in the U.S.A. by: Ecore. Revised 08/28/2017 Supersedes all previous versions Check website for updates

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

Powerdek Fleck. SECTION Resilient Athletic Flooring

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control

Architectural precast Concrete EARTH FRIENDLY BLOCK

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

Polycrete Big Block Standard Specification

SECTION DETECTABLE GUIDE TACTILES

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

INSTALLATION GUIDE 5 EASY STEPS TO PLACE & QUIET. Primary Acoustics ) ) ) ) ) \ \ \ \ \

SPECIFICATION SECTION : FIRE RATED GLASS PYRAN Platinum min. Fire Rated Ceramic Glass

UPOFLOOR Quartz Tile Architectural Guide Specification CSI/CSC Section Format [3-part] CSI Page Format

TILE TILE

SRP-AirOutshield UV Issued:

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS


SECTION WALL AND DOOR PROTECTION

SECTION ACCORDION FOLDING PARTITIONS

SECTION Arisfor WallGuard

Ceiling Tiles C200B - Specification

SECTION FIBER REINFORCED CEMENTITIOUS PANEL CLADDING

SECTION SOUND-ABSORPTIVE PANELS

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

SECTION / STC 52 METAL SOUND CONTROL DOORS

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

MASTER GUIDE SPECIFICATION

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

Expansion Joint Covers (079513)

L. W. Mountain, Inc. Floating Glue Installation Instructions *For use with engineered floors only*

ThermalShell Modular Insulated Pre-Cast Panels

Expansion Joint Covers

MFMA Guide Specification for Sleeper and Sleeper with Plywood Floor Systems

Architectural Roof Products Guide Specifications

SECTION GYPSUM BOARD SYSTEM

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

EverGuard Plaza Deck Roofing For Above-Grade Plaza Deck Applications

Transcription:

ENKASONIC FLOOR UNDERLAYMENT 9110 GS1197 Section 13080 SECTION 09618 SOUND CONTROL MATTING Part I General 1.1 Summary A. Section includes a sound control material for achieving an STC and IIC rating in excess of 50 to meet building code requirements in commercial and multi-family residential applications. B. This work shall consist of furnishing and installation of sound control system, including matting, isolation barrier, Sound Sealant acoustical caulk and related work in accordance with these standard specifications and at locations identified on drawings or designated by architect or acoustical consultant. This work shall include all necessary materials, labor, supervision and equipment for installation of a complete sound control system for flooring. C. Related Sections: 1. Cast in place concrete: Refer to Division 3 2. Insulation: Refer to Division 7 3. Joint treatments Refer to Division 7 4. Gypsum wall board Refer to Division 13 5. Flooring Refer to Division 9 6. Mechanical/electrical Refer to Division 15/16 7. Other appropriate project-specific specifications sections 1.2 References A. General: Refer to Division 1 References Section 1.3 System Description A. Performance Requirements: Provide sound control flooring system, which has been manufactured and installed to achieve STC, and IIC performance levels that exceed code requirements of not less than 50 for both ratings. 1.4 Submittals A. General: Prepare, review, approve and submit specified submittals in accordance with Conditions of the Contract and Division 1 Submittals Sections. Product data, shop drawings, samples and similar submittals are defined in Conditions of the Contract.

B. Product Data: Submit manufacturer s product data with independent testing of actual floor assembly and laboratory results of sound control system. Provide report of tested STC level and IIC level. C. Shop Drawings: Submit shop drawings showing layout, profiles and product components, including accessories for sound control system and termination of system. D. Samples: Submit verification samples for sound control matting and isolation material. E. Quality Assurance/Control Submittals: 1. Test Reports Certification: Submit certified test reports from an acceptable independent testing laboratory indicating compliance with applicable results of performance characteristics and physical properties. 2. Certificates (Qualification Data): Submit product certificates signed by manufacturer certifying materials comply with specified performance characteristics and physical requirements, showing full time quality control. Single-source manufacturer supplies sound Control system. F. Close out Submittals: 1. Warranty: Submit warranty documents specified herein. 2. Project Record Documents: Submit project record documents for installed materials in accordance with Division 1 Project Close Out (Project Record Documents) Section. 1.5 Quality Assurance A. Qualifications: 1. Installer Qualifications: Installer experienced (as determined by contractor) to perform work of this section, who has specialized in the installation of work similar to that required for this project, who can comply with manufacturer s warranty requirements, and who is an approved applicator as determined by sound control system manufacturer. 2. Manufacturers Qualifications: Manufacturer capable of providing job service during construction, approving an acceptable installer, recommending appropriate application methods and conducting a final inspection of the sound control system. 1.6 Delivery, Storage, and Handling A. Ordering: Comply with manufacturer s ordering instructions and lead-time requirements to avoid construction delays. B. Packing, Shipping, Handling and Unloading: Deliver materials in manufacturer s original, unopened, undamaged containers with identification labels intact.

C. Storage and Protection: Store materials protected from exposure to harmful weather conditions and at temperature conditions recommended by manufacturer. 1.7 Project Conditions/ Site Conditions A. Project Conditions: Refer to Conditions of the Contract for control and responsibility of project site including means, methods and techniques of construction by the contractor. Part II Products 2.0 Manufacturers A. Acceptable Distributor: Acoustical Solutions, Inc. 2420 Grenoble Road, Richmond, VA 23228 Phone: 800-782-5742 Fax: 804-346-8808 Email: info@acousticalsolutions.com B. Warranted Sound Control System: Enkasonic 9110 and Enkasonic Perimeter Isolation material. Provide system components from a single source supplier in accordance with manufacturer s warranty requirements. C. Standard Product Data Properties for Enkasonic Sound Control Matting Durability: After 10 years Enkasonic retains 97% of original thickness After 10 years - as pliable as a new roll After 10 years - performance is equal to newly manufactured rolls Thickness: 0.4 (10mm) Weight: 22.9 oz./yd 2 (776 g/m 2 ) 58.0 lbs./roll (26.3 kg/roll) Can be handled by one installer.

Physical Properties USA (Metric) Core Material Thickness inches (mm) 0.4 (10.2) Total weight oz/yd 2 (g/m 2 ) 22.4 (759.4) Core weight oz/yd 2 (g/m 2 ) 18.9 (640.7) Fabric weight oz/yd 2 (g/m 2 ) 3.5 (118.7) Performance Charachteristics Fire Rating Smoke Density Flame Spread Fuel Contribution * Will not promote flame spread. TECHNICAL DATA Enkasonic 9110 Nylon 6 NFPA Class A* 15 25 0 STANDARDS Tile Council of America Inc. RF900-89 New York City Dept. of Buildings MEA 144-89-M Ceramic Tile Institute CTI-R-4-113-79 ICBO Report 4778 Deflection Deflection characteristics of the most pliable of the CTI approved Enkasonic SR Floor Systems; DEFLECTION* Pressure (psf) Inches (mm) Pressure (psf) Inches (mm) 100 0.028 (0.711) 500 0.087 (2.210) 200 0.046 (1.168) 1000 0.131 (3.327) 300 0.061 (1.549) 2000 0.189 (4.801) 400 0.075 (1.905) 4000 0.256 (6.502) * Deflection characteristics of the most pliable of the CTI approved Enkasonic SR Floor Systems: Case #5 Enkasonic with WonderBoard Case #5-Enkasonic with Wonder-Board.

USA (Metric) 9110-101-0002 Core width inches (cm) *39.0 (99.1) Length feet (meters) 111.0 (33.8) Area yd 2 (m 2 ) 40.0 (33.5) Roll diameter inches (cm) 27.0 (68.6) Gross roll weight lbs (kg) 58.0 (26.3) * Plus 3" overlap STANDARD PACKAGING INFORMATION Other Accessories Sound Sealant Acoustical Caulk: A permanently resilient, non-shrinking latex-based sealant as distributed by Acoustical Solutions, Inc. Adhesive: Franklin #711, Franklin #1011, or W. W. Henry #116 adhesive for bonding layers of plywood overlay together or equal. Duct Tape or Cellophane Tape: 2" (5 cm) wide to bond the 39" (1 m) wide strips of Enkasonic together. Welded, Galvanized Wire Mesh: 2 x2 x 16/16 gauge, ½" (13 mm) self-furred. Enkasonic Perimeter Isolation Material: See data sheet. Enkasonic 7918R Reinforcement Material: See data sheet. 2.1 Related Materials A. Concrete: Refer to Division 3 B. Insulation: Refer to Division 7 C. Sealant: Refer to Division 7 D. 2.2 Source Quality Control A. Single Source Responsibility: Obtain all sound proofing materials from single source for required warranty. Part III Execution 3.1 Surface Condition A. Sub floor shall be structurally sound. Deflection shall not exceed 1/360 of the span, including live and dead loads.

B. Sub floor shall be dry and free of debris. 3.2 Installation A. Perimeter Isolation Strip: 1. Install Enkasonic Perimeter ISO at the perimeter of the entire sub floor (including door frames), and around any protrusions through the installation. This procedure isolates the Enkasonic floor system from the walls in order to create an acoustical break, which will minimize the transmission of sound laterally from the "floating floor" to the walls. Also, the perimeter isolation material provides space for possible expansion of the finished flooring. 2. Adhere the foam perimeter isolation strip to the wall with construction adhesive applied as close as possible to the top of the foam strip. B. Enkasonic Sound Control Matting: 1. Lay the Enkasonic directly over the sub floor (or waterproofing membrane, if applicable) with the black mesh down, white fabric side up. Push the Enkasonic up tightly to the isolation barrier previously installed around the perimeter of the floor. 2. If hardwood flooring and plywood floating slab are to be used, place a layer of roofing felt on the sub floor prior to the Enkasonic. 3. If the waterproofing membrane is mopped-on, put a layer of roofing felt over the membrane before installation of the Enkasonic. 4. Butt adjoining edges of the black Enkasonic mesh together. Then tape [Duct Tape or 2" (5 cm) wide Cellophane Tape] the 3" (7.5 cm) wide longitudinal fabric overlap snug to the adjoining Enkasonic strip. The taping procedure seals the overlap seams and keeps any residual material from getting into the Enkasonic mesh. Tape seam at intersection of Perimeter Isolation and Enkasonic. 5. Enkasonic is free-floating. Do not attach it to the sub floor with nails, screws, staples, glue or any type of attachment. Specifier Note: It is necessary to install an overlay over the Enkasonic to receive and support the finished flooring. The overlay varies with the type of finish flooring. The overlays are: 1¼" (3.2 cm) mortar bed, 7/16" (11 mm) WonderBoard, ½" (4 cm) lightweight Concrete [1800 PSI (12.4 MPa)], 1½" (4 cm) Gypsum [2000 PSI minimum (13.8 MPa)], or two layers of minimum ½ plywood. Specific installation details are described in our installation bulletins. C. Finish Flooring:

1. After the finished flooring is installed, trim the perimeter isolation barrier to ¼ (6.5 cm) below the finished flooring. Fill the groove with a bead of acoustical sound sealant caulk. Do not allow hard grout to come in contact with the wall. If the floor is carpet or vinyl, trim the perimeter isolation barrier flush with the surface before the finished flooring is installed. Shim the molding to 1/16 to 1/32 (1.6 to 0.8 mm) above the finished flooring preventing a transmission path for sound between the finished floor and wall. 2. If a flat base is adhered to the wall, space it 1/8" (3.2 mm) up from the tile surface, and run a bead of acoustical sealant into the void. 3. If a cove base is used, fill the joint between the last course of floor tile and the base with acoustical sealant. END OF SECTION