LSA 47.2 Low Voltage Alternators - 4 pole

Similar documents
LSA 51.2 Low Voltage Alternators - 4 pole

Low Voltage Alternators - 4 pole LSA 46.2

Low Voltage Alternators - 4 pole LSA 46.3

LSA 42.3 Low Voltage Alternators - 4 pole

LSA 53.2 Low Voltage Alternator - 4 pole

3867 en / a

3867 en / f. Alternators. LSA Pole Electrical and mechanical data

Low Voltage alternators - 4 pole LSA 42.3

3820 en / c

Alternators single phase dedicated - 4 Pole LSA 43.2 / LSA 44.2

3363 en / e

LSA Rating Table Low Voltage Alternators - 4 pole

ALTERNATOR. LSA 36 - single-phase to 11.5 kva

3456 en / c. 1 to 20 MW Land and offshore applications

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form)

Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw)

Interconnection Application

Environmental Product Declaration FLSES. 3-phase induction motors with cast iron frame

Environmental Product Declaration PLSES. 3-phase induction ODP motors

Generation Application Part B: Technical Form

Product Environnemental Profile LSES. 3-phase induction motors with aluminium frame

Connection of generation plant to distribution networks. Guidance on completing the application form

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

The company 2 Our vision 3 Our mission 3 Marelli Motori Group of companies 4 Core markets 6 Our commitment to quality 8

Generator set data sheet. 410 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Zero cross function. DIN track mounting *2. Screw mounting

Generator set data sheet. 80 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Cannon Trident Connector System

GARKANE ENERGY COOPERATIVE SMALL GENERATOR QUALIFIED FACILITY INTERCONNECTION APPLICATION

Dated: April 16, 2002

180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3

EC medium pressure axial fans.

Marine motors. 10/2 Orientation 10/2 Overview 10/3 Benefits 10/3 Application 10/3 Technical specifications 10/5 More information

Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

EC medium pressure axial fans. The efficient system solution.

135 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3

MATERIAL AND EQUIPMENT STANDARD FOR ROTATING ELECTRICAL MACHINES DIRECT CURRENT MOTORS ORIGINAL EDITION MAY 1993

3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A T-XAVs 1 on white

Emissions level: EPA NSPS Stationary Emergency Tier 2

Axial Fans - Basic principles. Expertise, performance, innovation

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops.

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

1400 Prime 1125 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

Standby rating. Turbocharged and low temperature after-cooled

1540 Prime 1250 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P125-72

Power Quality Improvement in Distribution System Using Distribution Static Compensator

MAY-16 REV B2

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted)

Participation in the sale of Energy Efficient Appliances

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

Type Type 2000 Transducers. I/P & E/P Transducers

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P W

Unit Coolers SKB. 4 kw 30,5 kw.

SPECIFICATION FOR APPROVAL

MODEL 16ASX T/S - SPECIFICATION

DRUM MOTOR 138LS 138.5Ø 0.10kW kW, with steel helical gearbox

Bulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators

PHOTOVOLTAIC SOLAR ENERGY MONOCRYSTALLINE MODULES - SI-ESF-M-M W

1 29SEP03 ALL General update with miscellaneous changes in entire document.

SECTION A. NEC Compliance: Comply with NEC as applicable to installation and construction of electrical power/distribution transformers.

Equipment Specifications Low Voltage. Active Harmonic Filter

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm

DRUM MOTOR 216LS 216.0Ø 0.11kW kW, with steel helical gearbox

Rosemount 3154N Nuclear Qualified Pressure Transmitter

SBX 1000 In Situ Oxygen Transmitter

Applications. Capacitance Tolerance The last three digits represent significant figures. The first digit specifies the total number of digits.

15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 24VAC VAC. 1 Single-phase. SRH VAC Zero cross turn-on

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

Applications R46 K I P0 M

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

Simple operation and a built-in bypass function make the CSX series a pleasure to use with many benefits in a tidy package.

Documentation. Transient voltage suppressor - AX2090- TS Version: Date:

INTER PLANT STANDARD STEEL INDUSTRY

Wilo MC Self Priming, Horizontal Multi-Stage, High Pressure Pumps. Engineering Specification

Qualification Test Report VAL-U-LOK* Connectors

SUGGESTED SPECIFICATIONS Pump Frames through 64132

15 15A 20 20A 30 30A 40 40A 60 60A. Load voltage(rated) VAC VAC VDC 24VAC VAC

NUCLEAR POWER CORPORATION OF INDIA LTD TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 REV NO : 0 DATA SHEET A

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

Product Specification JUL 14 Rev. A1

- Zone 1, 2, 21, 22 - Mechanical strength - Reliability over time - Instant, bright illumination

Product information. UP-DO Pump Series Normal priming, centrifugal pumps with a double mechanical seal material: stainless steel 1.

INSULATION MONITORING RELAIS

Bulkhead Feed-throughs

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

Low and Medium Voltage Motor Repair

SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT

Introduction. Ultra Reliable

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

Transcription:

LSA 47.2 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Electrical and mechanical data

LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Specially adapted to applications The LSA 47.2 alternator is designed to be suitable for typical generator applications, such as: backup, prime power, cogeneration, marine applications, rental, telecommunications, etc. Compliant with international standards The LSA 47.2 alternator conforms to the main international standards and regulations: - IEC 634, NEMA MG 1.32-33, ISO 828-3, CSA C22.2 n -14, UL 1446 (UL 4 on request), marine regulations, etc. It can be integrated into a CE marked generator. The LSA 47.2 is designed, manufactured and marketed in an ISO 91 and ISO 141 environment. Top of the range electrical performance Class H insulation Standard 12-wire re-connectable winding, 2/3 pitch, type no. 6 (the LSA 47.2 L9 is available in two versions: 6-wire and 12-wire) Voltage range Hz: 22 V - 24 V and 38 V - 41 V (44 V) Voltage range 6 Hz: 28 V - 24 V and 38 V - 48 V High efficiency and motor starting capacity Other voltages are possible with optional adapted windings: - Hz : 44 V (no. 7), V (no. 9), 6 V (no. 23), 69 V (no. 2) - 6 Hz : 38 V and 416 V (no. 8), 6 V (no. 9) R 791 interference suppression conforming to standard EN 6-6-3, EN 6-6-2, EN 11 group 1 class B standard for European zone (CE marking) Excitation and regulation system suited to the application Volage regulator Excitation system SHUNT AREP PMG Current transformer for paralleling Mains paralleling Regulation options 3-phase sensing 3-phase sensing for mains paralleling unbalanced Remote voltage potentiometer R2 Std - - - - - - R4 Option Std Std C.T. R726 R731 R734 DC Option Option Option C.T. included included included : possible mounting Protection system suited to the environment The LSA 47.2 is IP 23 Standard winding protection for clean environments with relative humidity %, including indoor marine environments Options : Filters on air inlet : derating % Filters on air inlet and air outlet (IP 44) : derating % Winding protections for harsh environments and relative humidity greater than % Space heaters Thermal protection for windings and shields Reinforced mechanical structure using finite element modelling Compact and rigid assembly to better withstand generator vibrations Steel frame Cast iron flanges and shields Twin-bearing and single-bearing versions designed to be suitable for engines on the market Half-key balancing Sealed for life ball bearings, regreasable bearings (optional) Standard direction of rotation : clockwise when looking at the drive end view (for anti-clockwise, derate the machine by %) Accessible terminal box proportioned for optional equipment Easy access to the voltage regulator and to the connections Possible inclusion of accessories for paralleling, protection and measurement 9-way terminal block for voltage reconnection 2 Electric Power Generation

LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz General characteristics Insulation class H Excitation system SHUNT (12 wire) AREP or PMG Winding pitch 2/3 (N 6 or N 6S) AVR type R 2 R 4 Number of wires 12 (N 6) / 6 (N 6S) Voltage regulation (*) ±. % ±. % Protection IP 23 Short-circuit current - 3% (3 IN) : s Altitude m Total Harmonic distortion THD (**) no load < 1.% - on load < 2% Overspeed 22 min -1 Waveform: NEMA = TIF (**) < Air flow.9 m 3 /s (Hz) / 1.1 (6Hz) (*) Steady state (**) Total harmonic distortion between phases, no-load or on-load (non-distorting) Ratings Hz - 1 R.P.M. kva / kw - P.F. =.8 Duty/T C Continuous duty/4 C Continuous duty/4 C Stand-by/4 C Stand-by/27 C Class/T K H/12 K F/ K H/1 K H/163 K Phase 3 ph. 3 ph. 3 ph. 3 ph. Y 38V 4V 41V 38V 4V 41V 38V 4V 41V 38V 4V 41V 22V 23V 24V 22V 23V 24V 22V 23V 24V 22V 23V 24V Y Y 2V 2V 2V 2V 12 wires version LSA 47.2 VS2 kva 36 33 4 42 kw 2 264 324 336 LSA 47.2 S4 kva 4 37 43 4 kw 328 2 344 36 LSA 47.2 S kva 4 4 471 kw 364 324 377 4 LSA 47.2 M7 kva 46 7 kw 4 372 44 46 LSA 47.2 M8 kva 7 6 kw 44 4 46 48 LSA 47.2 L9 kva 6 3 63 66 kw 48 428 4 28 6 wires version Y 38V 4V 41V 38V 4V 41V 38V 4V 41V 38V 4V 41V 22V 23V 24V 22V 23V 24V 22V 23V 24V 22V 23V 24V LSA 47.9 L9* kva 6 3 63 66 kw 48 428 4 28 Ratings 6 Hz - 18 R.P.M. kva / kw - P.F. =.8 Duty/T C Continuous duty/4 C Continuous duty/4 C Stand-by/4 C Stand-by/27 C Class/T K H/12 K F/ K H/1 K H/163 K Phase 3 ph. 3 ph. 3 ph. 3 ph. Y 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 22V 24V 22V 24V 22V 24V 22V 24V Y Y 28V 22V 24V 28V 22V 24V 28V 22V 24V 28V 22V 24V 12 wires version LSA 47.2 VS2 kva 424 44 46 46 3 4 4 4 41 483 11 469 18 3 kw 339 363 36 36 31 328 328 328 361 386 4 49 37 4 414 424 LSA 47.2 S4 kva 4 48 12 3 442 442 46 47 13 33 3 81 kw 36 384 4 4 317 34 34 372 38 4 426 44 4 424 44 46 LSA 47.2 S kva 47 31 7 441 473 4 18 3 43 66 27 62 8 62 kw 38 48 42 46 33 378 3 414 42 434 43 474 422 4 468 LSA 47.2 M7 kva 62 6 62 62 23 66 81 9 6 61 669 68 62 668 69 7 kw 4 488 418 43 46 472 48 21 3 4 34 2 6 LSA 47.2 M8 kva 62 6 63 69 23 66 87 632 6 61 672 729 62 671 7 7 kw 4 488 4 2 418 43 47 6 48 21 38 83 37 64 6 LSA 47.2 L9 kva 62 661 68 7 6 69 634 67 643 77 734 78 667 728 763 82 kw 482 29 48 6 44 487 7 4 14 66 87 624 34 82 6 66 6 wires version Y 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 22V 24V 22V 24V 22V 24V 22V 24V LSA 47.2 L9* kva 62 661 68 7 6 69 634 67 643 77 734 78 667 728 763 82 kw 482 29 48 6 44 487 7 4 14 66 87 624 34 82 6 66 * AREP excitation only Electric Power Generation 3

LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Efficiencies 4 V - Hz (P.F.: 1) (P.F.:.8) LSA 47.2 VS 2 %.4..3.1.8.8.3 P.F. :.8.6 91.7 91 1 2 2 3 3 4 4 kva.1.4 LSA 47.2 S4.9.9.8..1.4. P.F. :.8.8 1 2 2 3 3 4 4 kva.2.8.8.9..8 LSA 47.2 M7.2.1..3 P.F. :.8 1 2 2 3 3 4 4 kva LSA 47.2 M8.1.3.1.9.2.6.4.1 P.F. :.8 2 3 4 6 kva.6.8 LSA 47.2 S.8.7.6..4.8 P.F. :.8 1 2 2 3 3 4 4 kva Reactances (%). Time constants (ms) - Class H / 4 V. Kcc Short-circuit ratio.38.37.33.41.32.37.38 Xd Direct-axis synchro. reactance unsaturated 336 322 37 37 36 33 32 Xq Quadrature-axis synchro. reactance unsaturated 21 1 214 184 216 198 1 T do No-load transient time constant 1738 18 18 1 18 1997 1997 X d Direct-axis transient reactance saturated 19.3 17.3 19.2 1.9 18.3 16. 16.2 T d Short-circuit transient time constant X d Direct-axis subtransient reactance saturated 13. 12.1 13. 11.1 12.9 11.4 11.6 T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated 18.4 16.3 18 14.7 17 1 1.2 Xo Zero sequence reactance unsaturated.9.9.9.7.6.9.2 X2 Negative sequence reactance saturated 16 14.2 1.8 13 1 13.2 13.4 Ta Armature time constant 1 1 1 1 1 1 1 Other class H/4 V data io (A) No-load excitation current 1.9.9 1.9.9.9 ic (A) On-load excitation current 3.8 3. 3.8 3.6 3.7 3.7 3.7 uc (V) On-load excitation voltage 39 3 38 36 37 36 36 ms Response time ( U = 2% transient) kva Start ( U = 2% cont. or % trans.) SHUNT 722 8 8 73 119 128 128 kva Start ( U = 2% cont. or % trans.) AREP 8 3 3 11 12 14 14 % Transient U (on-load 4/4) SHUNT - P.F.:.8 LAG 16.8 1. 16.7 14.6 16.2 1 14.8 % Transient U (on-load 4/4) AREP - P.F.:.8 LAG 13.7 12.7 13.6 11.9 13.2 12.2 12.1 W No-load losses 44 69 69 64 612 678 688 W Heat dissipation 278 247 2378 234 262 2749 2672.2 LSA 47.2 L9 (12 w) LSA 47.2 L9 (6 w)..1..4.3.2.2.1,1,1.7.4..3 P.F. :.8 2 3 4 6 7 kva VS2 (12w) S4 (12w) S (12w) M7 (12w) M8 (12w) L9 (12w) L9 (6w) 4 Electric Power Generation

LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Transient voltage variation 4V - Hz Load application (SHUNT excitation) 2 % 2 VS 2 S 4 S Load application (AREP or PMG excitation) 2 % 2 VS 2 S 4 S 1 1 2 3 4 6 7 8 kva 2 3 4 6 7 8 kva kva at.8 power factor kva at.8 power factor Load rejection (SHUNT excitation) VS 2 S 4 S Load rejection (AREP or PMG excitation) VS 2 S 4 S 3% 3% 2 2 Voltage rise 2 1 Voltage rise 2 1 2 3 4 6 7 8 kva 2 3 4 6 7 8 kva kva at.8 power factor kva at.8 power factor Motor starting (SHUNT excitation) 3% VS 2 S 4 S Motor starting (AREP or PMG excitation) 3% VS 2 S 4 S 3 3 2 2 2 1 2 1 2 4 6 8 12 kva 2 4 6 8 12 14 kva kva Locked rotor kva Locked rotor 1) For a starting P.F. other than.6, the starting kva must be multiplied by K = Sine P.F. /.8 2) For voltages other than 4V (Y), 23V (D) at Hz, then kva must be multiplied by (4/U) 2 or (23/U) 2. Electric Power Generation

LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Efficiencies 48 V - 6 Hz (P.F.: 1) (P.F.:.8) % 91 9 % 91 9 LSA 47.2 VS 2.3.2.1.4.4.7.3.1 P.F. :.8 91.1 9.4 2 3 4 kva LSA 47.2 S4.7.6.6.9.1 P.F. :.8.3.9.8 91.7 91.1 2 3 4 6 kva.3 91.7 LSA 47.2 M7.9..2.7.4.3 P.F. :.8 91 2 3 4 6 7 kva LSA 47.2 M8.1.9.6.7.8.2.6.4.2 P.F. :.8 2 3 4 6 7 8 kva LSA 47.2 S %.7.7.6.1.9.1.3 P.F. :.8.7.4 91.7 91 2 3 4 6 7 kva Reactances (%). Time constants (ms) - Class H / 48 V VS2 (12w) S4 (12w) S (12w) M7 (12w) M8 (12w) L9 (12w) L9 (6w) Kcc Short-circuit ratio.36.36.32.4.31.3.36 Xd Direct-axis synchro. reactance unsaturated 349 33 373 319 376 344 338 Xq Quadrature-axis synchro. reactance unsaturated 29 21 223 191 22 26 23 T do No-load transient time constant 1738 18 18 1 18 1997 1997 X d Direct-axis transient reactance saturated 2.1 18 2.1 16. 19.2 17.2 16.9 T d Short-circuit transient time constant X d Direct-axis subtransient reactance saturated 14.1 12.6 14 11.6 13.4 11.8 12.1 T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated 19.1 16.9 18.8 1.3 17.8 1.6 1.8 Xo Zero sequence reactance unsaturated.1.4.1.1.9.9.4 X2 Negative sequence reactance saturated 16.6 14.8 16. 13. 1.6 13.7 14 Ta Armature time constant 1 1 1 1 1 1 1 Other class H/48 V data io (A) No-load excitation current 1.9.9 1.9.9.9 ic (A) On-load excitation current 3.9 3. 3.9 3.7 3.8 3.7 3.7 uc (V) On-load excitation voltage 4 3 39 37 38 37 37 ms Response time ( U = 2% transient) kva Start ( U = 2% cont. or % trans.) SHUNT 89 1136 1136 1318 1433 1 14 kva Start ( U = 2% cont. or % trans.) AREP 9 1271 1271 1473 166 1733 1737 % Transient U (on-load 4/4) SHUNT - P.F.:.8 LAG 17.3 16 17.3 1 16.7 1. 1.3 % Transient U (on-load 4/4) AREP - P.F.:.8 LAG 14.1 13 14.1 12.2 13.6 12.6 12.4 W No-load losses 84 89 89 8 3 44 8 W Heat dissipation 26 26 24 2863 3219 3387 33.2.7.8.7.1.2. LSA 47.2 L9 (12 w) LSA 47.2 L9 (6 w).6.2.2.1.1.7.6.9.6.4 P.F. :.8 2 3 4 6 7 8 kva 6 Electric Power Generation

LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Transient voltage variation 48V - 6 Hz Load application (SHUNT excitation) 2 % 2 1 VS 2 S 4 S Load application (AREP or PMG excitation) 2 % 2 1 VS 2 S 4 S 2 4 6 8 kva 2 4 6 8 kva kva at.8 power factor kva at.8 power factor Load rejection (SHUNT excitation) Load rejection (AREP or PMG excitation) 3% VS 2 S 4 S 3% VS 2 S 4 S 2 2 Voltage rise 2 1 Voltage rise 2 1 2 4 6 8 kva 2 4 6 8 kva kva at.8 power factor kva at.8 power factor Motor starting (SHUNT excitation) Motor starting (AREP or PMG excitation) 3% VS 2 S 4 S 3% VS 2 S 4 S 3 2 3 2 2 1 2 1 2 4 6 8 12 14 kva 2 6 14 18 kva Locked rotor Locked rotor 1) For a starting P.F. other than.6, the starting kva must be multiplied by K = Sine P.F. /.8 2) For voltages other than 48V (Y), 277V (D), 24V (YY) at 6 Hz, then kva must be multiplied by (48/U) 2 or (277/U) 2 or (24/U) 2. Electric Power Generation 7

LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz 3-phase short-circuit curves at no load and rated speed (star connection Y) LSA 47.2 VS2 AREP or PMG Current (A) Symmetrical Asymmetrical SHUNT 1 time (ms) LSA 47.2 S4 AREP or PMG Current (A) Symmetrical Asymmetrical SHUNT 1 time (ms) LSA 47.2 S AREP or PMG Current (A) Symmetrical Asymmetrical SHUNT 1 time (ms) Influence due to connection Curves shown are for star (Y) connection. For other connections, use the following multiplication factors: - Series delta : current value x 1.732 - Parallel star : current value x 2 8 Electric Power Generation

LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz 3-phase short-circuit curves at no load and rated speed (star connection Y) LSA 47.2 M7 AREP or PMG Current (A) SHUNT Symmetrical Asymmetrical 1 time (ms) LSA 47.2 M8 AREP or PMG Current (A) Symmetrical Asymmetrical SHUNT 1 time (ms) LSA 47.2 L9 (6w / 12 w) AREP or PMG Current (A) SHUNT Symmetrical Asymmetrical 1 time (ms) Influence due to short-circuit Curves are based on a three-phase short-circuit. For other types of short-circuit, use the following multiplication factors. 3-phase 2-phase L/L 1-phase L/N Instantaneous (max.) 1.87 1.3 Continuous 1 1. 2.2 Maximum duration (AREP/PMG) sec. sec. 2 sec. Electric Power Generation 9

LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Single bearing dimensions L Y DIA, X Eq.Sp holes on U P.C.D. A.V.R. AH 14, 33 CF Xg LB 6 49 17 74 ß PMG option Cable 12 Ø P -,127 Ø N -, -, Ø BX Ø 616 89,3 Ø 23 2 x Ø13 Ø 26 12-1 62 3 867 AIR OUTLET 6 6 18 228 244 3 68 28 13 9 AIR INLET Access to rectifiers 6 7 S DIA, XBG Eq. Sp. holes on M P.C.D. Dimensions (mm) and weight Coupling Type L without PMG LB Xg Weight (kg) Flex plate 11 1/2 14 18 LSA 47.2 VS2 41 9 437 976 Flange S.A.E 1 X X LSA 47.2 S4 11 6 471 1113 Flange S.A.E 1/2 X LSA 47.2 S 11 6 471 1113 Flange S.A.E X X LSA 47.2 M7 121 116 11 124 LSA 47.2 M8 121 116 2 1289 LSA 47.2 L9 1221 1176 4 1372 Flange (mm) Flex plate (mm) S.A.E. P N M XBG S β CF S.A.E. BX U X Y AH 1 713 11.17 3.22 12 12 1 1 11 1/2 32.42 333.38 8 11 39.6 1/2 713 84.2 619.12 12 14 1 22 14 466.72 438.1 8 14 2.4 713 647.7 679.4 16 14 11 1 42 18 71. 42. 6 17 1.7 Torsional analysis data Xr Ø 7 Ø 6 Lr Ø 11 Ø 12 Ø 11 Ø 1 Ø 7 Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm 2 ): (4J = MD 2 ) Flex plate S.A.E. 11 1/2 Flex plate S.A.E. 14 Flex plate S.A.E. 18 Type Xr Lr M J Xr Lr M J Xr Lr M J LSA 47.2 VS2 432. 29 387.99 418.3 29 387 6.12 48. 29 387 6.38 LSA 47.2 S4 47 89 442 6.9 46 89 442 7.3 446 89 442 7.29 LSA 47.2 S 47 89 442 6.9 46 89 442 7.3 446 89 442 7.29 LSA 47.2 M7 1189 4 7.61 4 1189 4 7.74 486 1189 4 8 LSA 47.2 M8 21 1189 14 8.1 7 1189 14 8.14 497 1189 14 8.4 LSA 47.2 L9 42 129 47 8.2 28 129 47 8.6 18 129 47 8.91 NOTE : Dimensions are for information only and may be subject to modifications. Contractual 2D drawings can be downloaded from the Leroy- Somer site, 3D drawing files are available upon request. Electric Power Generation

LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Two bearing dimensions L AVR access 13 Xg LB 6 49 74 1 1 hole M2x42 3 17 PMG option Cable 12 Ø 713 Ø 2 -,127 Ø 11,17 Ø 8 m6 Ø 616 472 89,3 Ø 23 2 x Ø13 9 14 22 12-1 3 867 AIR OUTLET 68 AIR INLET 62 6 6 2 13 1 13 13 9 28 Diode access 7 M DIA, 12 ep. sp. hole on 3,22 PCD Dimensions (mm) and weight Type L without PMG LSA 47.2 VS2 111 21 47 9 LSA 47.2 S4 1211 81 491 1126 LSA 47.2 S 1211 81 491 1126 LSA 47.2 M7 1311 1181 31 123 LSA 47.2 M8 1311 1181 31 132 LSA 47.2 L9 1331 121 6 13 LB Xg Weight (kg) Torsional analysis data Xr 13 Ø 8 Ø 9 Ø 6 Lr Ø 11 Ø 12 Ø 11 Ø 1 Ø 7 Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm 2 ): (4J = MD 2 ) Type Xr Lr M J LSA 47.2 VS2 3.4 1139 368..79 LSA 47.2 S4 433.2 1199 424 6.7 LSA 47.2 S 433.2 1199 424 6.7 LSA 47.2 M7 473 1299 476.2 7.41 LSA 47.2 M8 483. 1299 4.9 7.81 LSA 47.2 L9 4. 1319 28 8.32 NOTE : Dimensions are for information only and may be subject to modifications. Contractual 2D drawings can be downloaded from the Leroy- Somer site, 3D drawing files are available upon request. Electric Power Generation 11

www.leroy-somer.com/epg Linkedin.com/company/Leroy-Somer Twitter.com/Leroy_Somer_en Facebook.com/LeroySomer.Nidec.en YouTube.com/LeroySomerOfficiel Nidec 217. The information contained in this brochure is for guidance only and does not form part of any contract. The accuracy cannot be guaranteed as Nidec have an ongoing process of development and reserve the right to change the specification of their products without notice. Moteurs Leroy-Somer SAS. Siège : Bd Marcellin Leroy, CS 1, 1691 Angoulême Cedex 9, France. Capital social : 6 8 12, RCS Angoulême 338 67 28. 3782 en - 217. / j