DR 6000 UV-VIS SPECTROPHOTOMETER

Similar documents
DR 1900 PORTABLE SPECTROPHOTOMETER

Diving into a new dimension: Quality meets efficiency

Laboratory & Field Instruments: Sample Cells. Sample Cells. See Inside!

DR/800. Series Colorimeters. High-Value, High-Capability Instruments for Water Quality Analysis

2019 Microbac Laboratories Inc. Ohio Valley Division

HI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified

DR /2400 and DREL /2400 Spectrophotometer + Portable Laboratories. Get moving with the DR/ 2400 spectrophotometer: Made-to-measure in situ analysis

Thermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries

ENSURE WATER QUALITY FOR PEOPLE AROUND THE WORLD HACH HACH SOUTHEAST ASIA. Contact Us. Contact Number: (65) Address:

Why Hach Reagents? Alphabetical Listing of Reagents

CALIFORNIA STATE ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing

DR/800 Series Colorimeters Multi-parameter analysis in the palm of your hand!

Chemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

Laboratory Turnaround Times and Prices

Laboratory & Field Instruments: Spectrophotometers & Colorimeters

LABORATORY TURNAROUND TIMES AND CHARGES

As a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to:

Final Report WP-225. WatR Pollution Study. Open Date: 10/18/13. Close Date: 12/02/13. Report Issued Date: 12/04/13

West Virginia Department of Environmental Protection hereby certifies Microbac - Ohio Valley Division

9100 UV-Vis Spectrophotometer

NEW. Multiparameter Photometers. with Advanced Optics and ph Meter

HI801 iris Spectrophotometer

T100 T100+ Testing items: Portable spectrophotometer. COD Cr. (low concentration) (high concentration) Ammonia Chromium VI Cyanide COD

STATE OF CONNECTICUT

Phosphorus, Reactive (Orthophosphate)

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

Precise & Affordable. Reliable water analysis. Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure

ANALYTES available for testing

Final Report DMR-QA 36. NPDES Permit: IL DMR-QA Study. Open Date: 03/18/16. Close Date: 07/01/16. Report Issued Date: 07/29/16

As a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to:

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

Abu Dhabi Trade Effluent Standards & Regulations Summary

December 6, 2018 FID:

RESOLUTION NO. RS Modification of Water and Sewer Rates Department of Water Quality (FY 2018) RECITALS

AUTOMATED WATER ANALYSIS

QUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;

STATE ENVIRONMENTAL LABORATORY SERVICES DIVISION

SPECIFICATION NO.1197S Addendum No.4 Attachment D. Appendix L- Ground Water Quality Data and Revised Construction Groundwater Discharge Plan

Appendix U. Mapping of Water Quality Concentration Contours across the Province

In the fall of 2008, Barr and PolyMet identified four sources of historical Colby Lake water quality data. Those sources are listed below:

Appendix C1: Batch Kinetics Tests

DR/4000 PROCEDURE OXYGEN SCAVENGERS. 4. Fill a second sample cell (the blank) with 25 ml of deionized water.

CALA Directory of Laboratories

Micro Methods Laboratory Quality Assurance Manual

Advancements in Field Testing Equipment

Just Prove it. Spectroquant Prove

um"ts: m1 1grams per rt1er (mg./l)

Nitrogen, Simplified TKN (s-tkn ) DOC

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE

HACH CHEMISTRIES, REAGENTS AND STANDARDS

French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road

NEILSON RESEARCH CORPORATION

Just Prove it. Spectroquant Prove

Surface Water Samples: Containers, Preservation and Hold Times Table

Appendix C: Water Quality Data

A. Water sampling and analysis

Portable photometer for field and laboratory use

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed

Parameter monitored Standard methodology used Detection limit

CALIFORNIA STATE ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing

To meet our acceptance criteria, we may require you to pre-treat your wastewater before it is discharged to sewer.

Environment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand

DelAgua Safe Water. Reagent Identification Chart for Lovibond Tintometer photometers

Environment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra

Chemical Oxygen Demand

SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS

TITLE: SABS PROFICIENCY TESTING SCHEME, RSA

Instrument Adapters Light shield DR 6000, DR 5000 DR 3900 LZV849 DR 3800, DR 2800 LZV646 DR or (A)

Ground Water & UST Samples: Containers, Preservation and Hold Times Table

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

CALA Directory of Laboratories

CLEAN WATER Clean Water PT Scheme Schedule Clean Water PT Scheme Schedule. Schedule subject to change see ERA s website at

ENVIRONMENTAL LABORATORY LICENSE. ACZ Laboratories, Inc. AZ0102

Environmental Management System

CALA Directory of Laboratories

SCOPE OF ACCREDITATION

C 99 & C 200 Series Multiparameter Bench Photometers

DROGHEDA LANDFILL SITE COLLON ROAD, MELL, DROGHEDA

Parameter Method Price per Test Parameter Method Price per Test. Oil and Grease Soxhlet

Parameter Method Price per Test Parameter Method Price per Test

CERTIFICATE OF ANALYSIS

Outline. Control Fundamentals Control Opportunities

UV/Vis Spectrophotometry. Time for New Demands SPECORD PLUS

FORM 26R CHEMICAL ANALYSIS OF RESIDUAL WASTE ANNUAL REPORT BY THE GENERATOR INSTRUCTIONS GENERAL INFORMATION

Groundwater Monitoring on a Budget. June Mooney, Water Quality Specialist, Greater Augusta Utility District

Dimethylphenol Method Method LR (0.23 to mg/l NO 3 N or 1.00 to mg/l NO 3 ) TNTplus 835

Water Analysiss. Solutions for photometry

Acceptance standards and charging rates for

Oxygen Demand, Chemical

Phosphorus, Reactive (Orthophosphate)

Oxygen Demand, Chemical

Simplified Procedures for Water Examinations

City of Ottawa Drinking Water Quality Test Results SUMMARY TABLE

Ground Water Quality Report. Inorganic Ground Water Quality Time Series

Ground Water Quality Report. Inorganic Ground Water Quality Time Series

W12A Landfill Groundwater, Leachate, Water Well, Landfill Gas and Surface Water Quality Monitoring Program

State of Utah. Department of Health Environmental Laboratory Certification Program. Certification is hereby granted to

Microbac Laboratories, Inc. AZ0723

Transcription:

DR 6000 UV-VIS SPECTROPHOTOMETER Applications Beverage Drinking Water Industrial Water Pharmaceutical Power Wastewater The industry s most advanced lab spectrophotometer. With UV and Visible Spectrum capabilities, over 250 pre-programmed methods including the most common testing methods used, guided procedures, and integrated quality assurance software, the DR 6000 ensures you are ready to handle your comprehensive water testing needs. Your Water Testing Needs, All in One Spectrophotometer The DR 6000 has the most pre-programmed testing methods, including high-speed wavelength scanning across the UV and Visible Spectrum. Accessories for High Volume and High Accuracy Testing Needs A carousel sample changer allows up to seven sequential measurements. The Sipper Module, an instrument-controlled sample delivery system, increases precision by constant optical characteristics. Advanced Quality Assurance at Your Fingertips The DR 6000 comes with integrated QA software for scheduling, documenting and interpreting all of your needed quality measurements. Guided Procedures and Elimination of False Readings The DR 6000, when used with TNTplus reagent vials, provides the accurate results you need by guiding you stepby-step through your testing procedures. With TNTplus, the instrument averages 10 readings and eliminates outliers, making scratched, flawed or dirty glassware a non-issue. Automatically Avoids Errors RFID* technology automatically updates the program calibration factors when you place a TNTplus reagent box near the DR 6000. The instrument identifies chemistry expiration dates via a barcode on the vials, and detects chemistry coefficient factors to avoid errors that can occur in lot-to-lot variations in the chemistry. *RFID technology currently available only in US, Anguilla, American Samoa, Australia, Bolivia, Canada, Cayman Islands, Columbia, Dominican Republic, El Salvador, Federated States of Micronesia, Guam, Guatemala, Marshall Islands, New Zealand, Northern Mariana Islands, Palau, Panama, Puerto Rico, and US Virgin Islands.

2 DR 6000 UV-Vis Spectrophotometer Specifications* Operating Mode Source Lamp Wavelength Range Wavelength Accuracy Wavelength Reproducibility Wavelength Resolution Wavelength Selection Spectral Bandwidth Scanning Speed Photometric Measuring Range Photometric Accuracy Photometric Linearity Stray Light Transmittance (%), absorbance and concentration (wavelength, time) Tungsten (visible range), deuterium (UV range) 190-1100 nm ± 1 nm < 0.1 nm nm 0.1 nm Automatic, based on method selection 2 nm 900 nm/min (in 1 nm steps) ± 3 Abs 5 mabs at 0.0-0.5 Abs <1% at 0.5-2.0 Abs at 546 nm 0.005-2 Abs 0.01 at > 2 Abs with neutral glass at 546 nm KI-solution at 220 nm < 3.3 Abs/ < 0.05% Display Data Logger Preprogrammed Methods TFT 7 inch WVGA color touch 5000 data points (result, date, time, sample-id, user-id) > 250 User Programs 200 Sample Cell Compatibility Dimensions (H x W x D) Weight Operating Conditions Storage Conditions Enclosure Rating Rectangular: 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 16 mm, 1 inch Optional 100 mm rectangular cell with additional adapter 8.5 in x 19.7 in x 18.1 in (215 mm x 500 mm x 460 mm) 24.25 lbs. (11 kg) 10 at 40 C, max. 80% relative humidity (non-condensing) -25 to 60 C max. 80% relative humidity (non-condensing) IP20 with closed lid Interfaces USB type A (2), USB type B, Ethernet, RFID module Warranty 1 year *Subject to change without notice. Principle of Operation Hach's TNTplus chemistries and spectrophotometers are made to work seamlessly with each other. Many of the tests are EPA compliant. Over 35 tests available including these popular EPA Approved Parameters: - Ammonia - COD - Chlorine - Chromium - Iron - Nitrate - Nitrite - Nitrogen - Phosphorus - Sulfate

DR 6000 UV-Vis Spectrophotometer 3 Available Tests The following table lists available tests and overall ranges for the Hach DR 6000 Benchtop Spectrophotometer. The ranges may represent more than one available test for the instrument. Consult your Hach representative, Customer Service, the Hach Master Catalog, or the Hach web site at www.hach.com for complete details of all available tests for this instrument. TNTplus Parameter Range Test Alachlor 0.1 to 0.5 ppb, threshold Alkalinity, Total 25 to 400 mg/l Aluminum 0.002 to 0.800 mg/l Ammonia, Nitrogen 0.015 to 50.0 mg/l Arsenic 0.020 to 0.200 mg/l Atrazine 0.5 to 3.0 ppb, threshold Barium 2 to 100 mg/l Benzotriazole 1.0 to 16.0 mg/l Boron 0.2 to 14.0 mg/l Bromine 0.05 to 4.50 mg/l Cadmium.7 µg/l to 0.30 mg/l Carbohydrazide 5 to 600 µg/l Chloramine, Mono 0.04 to 10.0 mg/l Chloride 0.1 to 25.0 mg/l Chlorine Dioxide 0.01 to 1000 mg/l Chlorine, Free 0.02 to 10.0 mg/l Chlorine, Total 2 µg/l to 10.0 mg/l Chromium, Hexavalent 0.010 to 1.00 mg/l Chromium, Total 0.01 to 0.70 mg/l Cobalt 0.01 to 2.00 mg/l Color 3 to 500 units COD (Chemical Oxygen Demand) 0.7 to 15,000 mg/l Copper 1 µg/l to 8.0 mg/l Cyanide 0.002 to 0.240 mg/l Cyanuric Acd 5 to 50 mg/l DEHA (Diethylhydroxylamine) 3 to 450 µg/l Dissolved Oxygen 6 µg/l to 40 mg/l Erythorbic Acid (Isoascorbic acid) 13 to 1500 µg/l Fluoride 0.02 to 2.00 mg/l Formaldehyde 3 to 500 µg/l Hardness, Total 4 µg/l to 4.00 mg/l (Calcium and Magnesium as CaCO 3 ) Hydrazine 4 to 600 µg/l Hydroquinone 9 to 1000 µg/l Iodine 0.07 to 7.00 mg/l Iron, Ferrous 0.02 to 3.00 mg/l Iron, Total 0.009 to 6.0 mg/l TNTplus Parameter Range Test Lead 3 µg/l to 2.0 mg/l Manganese 0.006 to 20.0 mg/l Mercury 0.1 to 2.5 µg/l Methylethylketoxime (MEKO) 15 to 1000 µg/l Molybdenum, Molybdate 0.02 to 40.0 mg/l Nickel 0.006 to 6.0 mg/l Nitrate, Nitrogen 0.01 to 35 mg/l Nitrite, Nitrogen 0.002 to 250 mg/l Nitrogen, Simplified Total Kjeldahl 0 to 16 mg/l Nitrogen, Total 0.5 to 150 mg/l Nitrogen, Total Inorganic Nitrogen, Total Kjeldahl Ozone PCB (Polychlorinated Biphenyls) Phenols Phosphonates Phosphorus, Acid Hydrolyzable 0.2 to 25.0 mg/l 1 to 150 mg/l 0.01 to 1.50 mg/l 1 to 50 ppm, threshold 0.002 to 0.200 mg/l 0.02 to 125.0 mg/l 0.06 to 100.0 mg/l Phosphorus, Reactive (Orthophosphate) 19 µg/l to 100.0 mg/l Phosphorus, Total 0.06 to 100.0 mg/l Potassium Quaternary Ammonium Compounds Selenium Silica Silver 0.1 to 7.0 mg/l 0.2 to 5.0 mg/l 0.01 to 1.00 mg/l 3 µg/l to 100 mg/l 0.005 to 0.700 mg/l Sulfate 2 to 900 mg/l Sulfide Surfactants, Anionic Suspended Solids Tannin and Lignin TOC (Total Organic Carbon) Tolyltriazole Toxicity TTHM (Trihalomethanes, Total) TPH (Total Petroleum Hydrocarbons) 5 to 800 µg/l 0.002 to 0.275 mg/l 5 to 750 mg/l 0.1 to 9.0 mg/l 0.3 to 700 mg/l 1.0 to 20.0 mg/l 0 to 100% Inhibition 10 to 600 µg/l 2 to 200 ppm, threshold Volatile Acids 27 to 2800 mg/l Zinc 0.01 to 3.00 mg/l

4 DR 6000 UV-Vis Spectrophotometer Ordering Information DR 6000 UV VIS Spectrophotometer includes a multi adapter for round and rectangular vials, basic user manual, CD with manual and procedure manual in PDF format. Power cords for US and EU. RFID version available only in a limited number of countries, including US, Australia, Bolivia, Canada, Guatemala, and New Zealand. For complete information, visit hach.com or contact your sales representative. LPV441.99.00012 LPV441.99.00002 DR 6000 UV VIS Spectrophotometer with RFID Technology DR 6000 UV VIS Spectrophotometer without RFID Accessories LQV157.99.20002 LQV156.99.10002 LZV902.99.00002 LZV902.99.00012 LZV943 LZV942 LZV941 SIP 10, sipper set for Pour-Thru methods, 1 inch vial LOC 100: Kit for Radio Frequency ID (RFID) based sample tracking Carousel Holder 7x1 cm Carousel Holder 5x1 inch Application Software Enzymatic Food Analysis Application Software Brewery Analysis Application Software Drinking Water Analysis Service Options Comprehensive warranty upgrade includes: All parts, labor, and shipping costs from the factory for depot repairs. 1 calibration per year on-site, factory recommended maintenance (including required parts), unlimited technical support calls. Also includes a loaner* while waiting for your factory repair. Please see service terms and conditions for additional details on our service plans, and to ensure you have an opportunity to review our environmental and safety requirements. *Based on availability WRTUPGDR6000 WarrantyPlus DR 6000 Spectrophotometer 1 Visit Comprehensive warranty upgrade includes: All parts, labor, and shipping costs from the factory for depot repairs. 1 calibration per year on-site, factory recommended maintenance (including required parts), unlimited technical support calls. Also includes a loaner* while waiting for your factory repair. Payments for services will be automatically deducted quarterly via credit card. This Evergreen service plan continues indefinitely until either the customer or Hach provides a 90 day written notice to terminate. Upon receiving Buyer s written notice of termination, the effective date will be 90 days after the following quarterly billing period. Prices may be adjusted with a 30 day written notice. Please see service terms and conditions for additional details on our service plans, and to ensure you have an opportunity to review our environmental and safety requirements. *Based on availability WRTUPGEVERDR6000 WarrantyPlus DR 6000 Spectrophotometer 1 Visit - Automatic Quarterly Payment Plan (Evergreen)

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.