NuRoof Retrofit Systems. Technical/Installation Information

Similar documents
PBR & PBU Panels. Technical/Installation Information

The Experts in Retrofit Design. Retrofit Solutions. Retro-R SSR NuRoof NuWall

PBR & PBU PANELS. Technical/Installation Information

Superior Structural Standing Seam Roof Systems

5V Crimp DESIGN/INSTALLATION INFORMATION

PBR & PBU PANELS. Technical/Installation Information

NuRoof Retrofit Systems. Technical/Installation Information

Superior Structural Standing Seam Roof Systems

Residential Pricing Guide

LokSeam. Design/Installation Information

TYPICAL ROOF CONDITION LAYOUT

LokSeam. Design/Installation Information. This booklet includes: Trims and Accessories Design and Installation Information

* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.

Retro-R DESIGN/INSTALLATION INFORMATION

TRIAD CORRUGATED METAL, INC.

IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL.

SECTION PRE-ENGINEERED METAL BUILDING

R PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide.

Trusted Tested Tough Kalaeloa Blvd, Kapolei, Hawaii Phone (808) Fax (808) Neighbor Islands (800)

Richmond, VA 800/ Rome, NY 800/ Salt Lake City, UT 800/ San Antonio, TX 800/ COMMERCIAL / INDUSTRIAL PRICING

WESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide.

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900

TABLE OF CONTENTS PRODUCT CATALOGUE fax OVERVIEW PBR 7.2 LONGSPAN ECONORIB

Table of Contents. 3. Standing Seam Panels

EVERSEAM 20 APPLICATION GUIDE

a division of NCI Standing Seam Roof Systems

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

5V CRIMP. Technical/Installation Information

Western States 7/8 Corrugated

PROLOK EAVE PROLOK ROOFING PANEL ROOFING NAIL

238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM #

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS

CONTINUOUS VENTILATORS

Preformed Metal Roof And Wall Systems

Prior to ordering and installing materials, all dimensions should be verified by field measurements.

SECTION PLATE CONNECTED WOOD TRUSSES

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5

Central Seam Plus. Central-Loc

MBCI Weathertightness WARRANTIES

BattenLok HS. Technical/Installation Information

SHURLOC 150 STANDARD DETAILS

TECHNICAL ERECTION MANUAL SUPER SEAM II

Covering Design Regions

TRIAD CORRUGATED METAL, INC.

Light-Metal Roof Edge, Raised

STEEL DECK INSTITUTE Industry Standard Terms & Definitions

Industry Standard Terms & Definitions Of The Steel Deck Institute

SECTION PRE - ENGINEERED METAL BUILDING MATERIALS

TECHNICAL ERECTION MANUAL SUPER SEAM PLUS

VP ROOF SYSTEMS SSR ROOF SYSTEM. WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS

Warranties

UltraLok Roof System Product Application Guide INDEX

Pro Lok Roof System Product Application Guide INDEX

Designer Series. Technical/Installation Information

Agricultural Pricing Guide

PRE-ENGINEERED METAL BUILDING SYSTEM

RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE

Metal Roofing. The Devil is in the Details SSRLU3B. I LU/HSW Hour

SECTION NON-STRUCTURAL METAL FRAMING

Corru-Fit Design Guide

SL-16. Design/Installation Information

Guardian. Standing Seam Roof System. Manual THIS MANUAL REPLACES ALL PREVIOUS MANUALS EFFECTIVE JANUARY 1, 2006 / JC & JEN

1 1/2" SSR. FABRAL The pursuit of excellence since 1967

Architectural Roof and Wall Products Guide Specifications

Technical Information

S BI COM P ON E NT CA T ALOG

Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Tile

Architectural Roof and Wall Products Guide Specifications

DESCRIPTION: Alucom, LLC NW 115 th Avenue Miami, FL Terrabella Classic Terrabella Verona Terrabella Shake

IMAGE II. Panel Information. Detail Conditions. Flashing Profiles. Accessory Profiles. Testing Information. Design/Installation Considerations PIM-1

KS SERIES - VERTICAL INSTALLATION

w w w. s a q u l i t y m e ta l s. c o m

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

Central Snap. Condition Details C SNAPDETAILS

2120 SW Poma Drive; Palm City, Florida Phone Fax

SSL-175. Specifications

CLIP-LOC. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations

Black s Metals Installation Guide

2120 SW Poma Drive; Palm City, Florida Phone Fax

AIA PRESENTATION. Retrofit Roof Systems NURF-1 (1 credit hour)

SECTION PRE-ENGINEERED METAL BUILDING SYSTEM (FOR OFFICE AREA)

Architectural Roof Products Guide Specifications

RS24-10 Single-Section Skylight System

ABSeam Panel Overview and Installation Instructions

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM

FABRAL The pursuit of excellence since 1967

The better way to build TM. Installation Manual NAILBASE PANELS

DL-200. Specifications

Dugout Covers Specifications

Professional Engineering Services. The Brand of Choice

Chapter 53: Endwall Overhang(s) Only - Enclosed

ML200 Panel Technical Data Guide

SECTION STEEL DECKING

Guardian-Lok. Standing Seam Roof System THIS MANUAL APPLIES TO GUARDIAN-LOK SYSTEMS. GUARDIAN-LOK REQUIRES PANEL SIDELAPS TO BE MECHANICALLY SEAMED.

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information

July Minimum Fastening Requirements (Fully Adhered)... 5

METAL ROOFING With more panel options in metal roofing, ABC has you covered.

CUSTOM STEEL BUILDINGS

Transcription:

Retrofit Systems Technical/Installation Information

INTRODUCTION If your roof is causing problems due to leaks, high maintenance costs and low energy efficiency, the MBCI NuRoof Retrofit System is the remedy. With the NuRoof Retrofit System, you can install a slopped roof which will eliminate leaks and minimize maintenance costs. Energy efficiency may also be increased substantially with additional insulation. The NuRoof Retrofit System allows design flexibility with a choice of roof slopes, hips, valleys, gable endwalls, vertical and trapezoidal standing seam panels, as well as the traditional PBR Panel. These panels are available in a wide range of colors and gauges. So, whether you are retrofitting an old warehouse, manufacturing plant or an office building, the MBCI NuRoof Retrofit System is the answer. ARCHITECT/OWNER RESPONSIBILITY The architect/owner using the MBCI NuRoof Retrofit System must recognize that the existing structural roof system most likely was designed based on the roof load being applied uniformly by means of a metal deck or similar substrate. The NuRoof Retrofit System will replace the uniform load with a series of concentrated loads onto the existing roof system which may not be feasible in all applications. Also, as a result of the addition of the retrofit roof, additional weight will be added to the existing roof that must be checked. MBCI highly recommends that a structural engineer conduct an investigation of the entire structure being proposed for a retrofit system to determine the adequacy of the existing roof structure to withstand additional loading. Their investigation should include the condition of the existing structural, existing dead loads, can existing loads be removed, (i.e. rock ballast) and what additional dead loads will the structure accept and at what spacing? RIDGE OF ROOF MEMBERS PARALLEL TO ROOF SLOPE Installation Sequence Begins on Page NR-9 MEMBERS PERPENDICULAR TO ROOF SLOPE Installation Sequence Begins on Page NR-15 SLOPE SLOPE SLOPE SLOPE RIDGE OF ROOF NOTE: 1. Some buildings may have structural members in both directions. In this case, each method may be used where required. 2. Hipped NuRoof Systems may require both methods.

TABLE OF CONTENTS PRODUCT INFORMATION Architect/Engineer Information... NR-5 - NR-6 Design Data Sheet... NR-7 Section Properties... NR-8 DESIGN INFORMATION Retrofit Framing over Structural Members Parallel to the Roof Slope Base Channel Attachment.... NR-9 Column Attachment... NR-10 X Bracing Attachment.................................................................. NR-11 Longitudinal Transverse (Recommended every 40 minimum) Purlin Attachment... NR-12 Strut Attachment (Every braced column line)... NR-13 Panel Attachment... NR-14 Retrofit Framing over Structural Members Perpendicular to the Roof Slope Base Zee Attachment... NR-15 Column Attachment... NR-16 X Bracing Attachment.................................................................. NR-17 Longitudinal Transverse (Recommended every 40 minimum) Purlin Attachment... NR-18 Strut Attachment (Every braced column line)... NR-19 Panel Attachment... NR-20 Gable Endwall Isometric/Cross-section... NR-21 Hip Roof Isometric Showing Combination of Base Zee/Base Shoe Utilization and Columns... NR-22 Hip Framing (B-T-B Channels)... NR-22 Valley Isometric Showing Combination of Base Zee/Base Shoe Utilization and Columns... NR-23 Valley Framing (B-T-B Channels)... NR-23 Peak Framing Isometric/Cross-section... NR-24 DETAILS Base Channel/Column Connection (Flange).... NR-25 Base Zee/Column Connection (Flange)... NR-25 Base Zee/Column Connection (Web)... NR-26 Base Zee Lap... NR-26 High Strength Base Zee/Column Connection (Flange/Web).... NR-27 Purlin to Column Connection (Flange)... NR-28 Purlin to Column w/purlin Clip (Flange)... NR-28 Purlin Lap to Column Connection (Flange)... NR-28 Purlin to Column Connection (Web)... NR-29 Purlin to Column w/purlin Clip (Web)... NR-29 Purlin Lap to Column Connection (Web).... NR-29 Angle Bracing... NR-30 - NR-35 Longitudinal Transverse SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-3

TABLE OF CONTENTS DETAILS (CONTINUED) Eave... NR-36 Overhang (w/parapet Wall) Eave (w/fascia Wall) Eave (w/angles) Edge/Corner Zone (For Use In High Wind Conditions).... NR-37 Architect/Engineer Information (Optional Method)... NR-38 NuRoof Optional Methods Isometric - Grid System... NR-39 Grid System Details.............................................................. NR-40 Isometric - SSR System Over Existing PBR Panel - Vented... NR-41 Eave Detail - Vented... NR-42 Clip Attachment Detail - Vented... NR-42 Rake Detail - Vented... NR-43 Rake w/termination Detail - Vented.... NR-44 Ridge Detail - Vented... NR-45 EndLap Detail - Vented.... NR-46 Isometric - SSR System Over Existing PBR Panel - Insulated... NR-47 Eave Detail - Insulated... NR-48 Clip Attachment Detail - Insulated... NR-48 Rake Detail - Insulated.... NR-49 Rake w/termination Detail - Insulated... NR-50 Ridge Detail - Insulated... NR-51 EndLap Detail - Insulated... NR-52 Copyright NCI Group, Inc. 2017 All Rights Reserved Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In a continuing effort to refine and improve products, MBCI reserves the right to discontinue products at any time or change specifications and/or designs without notice and without incurring obligation. To insure you have the latest information available, please inquire or visit our Web Site at www.mbci.com. Application details are for illustration purposes only and may not be appropriate for all environmental conditions, building designs, or panel profiles. Projects should be engineered to conform to applicable building codes, regulations, and accepted industry practices. Insulation is not shown in these details for clarity. If there is a conflict between this manual and the erection drawings, the erection drawings will take precedence. NR-4 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

PRODUCT INFORMATION ARCHITECT/ENGINEER INFORMATION 1. The recommended slope range of the retrofit roof is 1/4:12-4:12. For slopes greater than 4:12 please contact MBCI. 2. The maximum recommended height of the retrofit system above the existing roof is 10 feet. This is not due to the capacity of the framing, but to the altered shape of the building and its ability to withstand the new wind loads as well as erection limitations. 3. The NuRoof Retrofit System will add approximately 2 to 4 PSF to the weight of the existing roof. 4. Load transfer may result in concentrated loads occurring on the existing roof. A professional structural engineer must investigate the existing roof to be sure that no undesirable effects are created on the existing roof by the NuRoof Retrofit System. 5. Lateral wind forces will be developed at gabled endwalls created by the retrofit roof. These wind forces will be transmitted into the existing roof by the X bracing parallel to the retrofit purlins. MBCI cannot be responsible for the adequacy of the existing building to resist the additional wind forces which develop at these gabled endwalls. 6. The uniform retrofit roof loads will be concentrated through the retrofit columns. These concentrated loads are then transmitted to the existing roof deck above the existing roof structural members. The adequacy of the existing metal deck corrugations to resist web crippling must be investigated during the design phase. It is not recommended to install this system over the existing insulation board due to possible creep over the life of the system (consult the manufacturer of the existing insulation board for allow able static compressive loads). If the existing roof has moisture trapped within the layers from water intrusion, MBCI recommends the removal of the roofing materials (down to the existing deck) at all base channels or roof support zee locations. This will allow trapped moisture to be drawn out by proper ventilation. If the deck is corroded through to the structural framing, consult with your structural engineer for possible deck reinforcement at the column base attachments to maintain the integrity of the metal deck. NOTE: Existing metal decks can provide lateral support (diaphragm action) to the overall structure. Removing the metal deck at the column locations may compromise the integrity of the existing metal deck diaphragm system. Since the NuRoof Retrofit System relies on the existing metal deck to transfer its lateral loads to the existing structural system, the existing metal deck must remain intact. 7. An attic space will be created by the NuRoof Retrofit System. MBCI recommends proper venting of this attic space in accordance with applicable codes, to be determined by a mechanical engineer, allowing any trapped moisture to escape. MBCI also recommends that attic space be reviewed by other building, fire, or insurance related officials for possible sprinkling or extension of existing fire walls to the bottom of the new roof system. Use a mini mum of 3 vinyl faced roll insulation between the retrofit panels and the retrofit purlins to help prevent condensation and roof noise. If the use of retrofit framing in New Construction will result in the instal lation of HVAC equipment and ductwork in the attic space to conflict with the extensive bracing system required by the NuRoof Retrofit System, please consult with MBCI s sales engineering staff during the desig n phase to resolve these issues. 8. The NuRoof framework is equally effective over existing roof decks made of metal, Tongue and Groove wood and concrete decks. However, each existing roof system must be evaluated independently on its ability to accept multiple point loading from the retrofit system. SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-5

PRODUCT INFORMATION ARCHITECT/ENGINEER INFORMATION (Continued) 9. The NuRoof framework will be supplied in unpunched 20-0 lengths. Field cutting of material will be required. 10. For MBCI to properly design the retrofit framing, the following information is required: Retrofit roof live/wind load, collateral load, snow load, seismic zone, existing building size and location, existing structural orientation (parallel or perpendicular to retrofit roof slope) and spacing, type of existing substrate members, governing code, retrofit roof pitch, retrofit roof panel desired, and the use of hipped or gable ends. MBCI is not responsible for the ability of the existing building to accept the loads imposed upon it by the retrofit framework. The MBCI engineering department can conduct an engineering study of the proposed retrofit framing and provide column reactions based on the above information that may be used by your structural engineer to do their study of the existing structure. Following this page is a design data sheet. This sheet can be filled out and sent to MBCI for our Project Service Department to perform estimates, designs, drawings or a combination of all three. CAUTION In certain cases the retrofit roof panel selected may require additional retrofit purlins at the perimeter of the roof to ensure that the panel is capable of resisting the additional wind/snow load in this area. NR-6 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

PRODUCT INFORMATION DESIGN DATA SHEET PROJECT INFORMATION From: Live Load: psf ASTM E1592 Date: Dead Load: psf UL90 Project Name: Collateral Load: psf Factory Mutual Project Location: Snow Load: psf SREF (City, State, County): Wind Speed: mph Building Code: Importance Factor: Deflection Rqmts.: Exposure Category: ROOF GEOMETRY Length: ft Eave Height: ft Width: ft Overhang: ft Slope: :12 Parapet Height: ft (Please provide drawings of existing building - Including structural drawings) ROOF TYPE Built Up Shingle Other - Specify - Modified Bitumen Trocal Single Ply PVC ROOF SUBSTRATE Insulation Type: in. Tectum Thickness: in. Insulation Thickness: in. Concrete Thickness: in. Plywood Thickness: in. Lightweight Wood Thickness: in. Structural Metal Deck Thickness: in. Precast Metal Deck Gauge: Other - Specify MEMBERS Bar Joists: @ " o.c. Wood Trusses: @ " o.c. "Hot Rolled" Steel: @ " o.c. Concrete Beams: @ " o.c. Wood Rafters: @ " o.c. Other - Specify: @ " o.c. Has the existing structure been analyzed by a professional engineer? yes Engineer's name: no Engineer's phone #: NUROOF GEOMETRY Length: ft Ridge Condition: Width: ft Gable Slope: :12 Hip Eave Height: ft Roof Panels: (Profile, Width, Gauge) Overhang: ft Wall Panels: (Profile, Width, Gauge) Eave Condition: Eave Trim Fascia: (Profile, Width, Gauge) Box Gutter Structural Members: Red Oxide Sculptured Gutter Galvanized Snow Gutter (Please provide drawings of new proposed roof plan) NOTES SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-7

PRODUCT INFORMATION SECTION PROPERTIES D 50 X B1 B2 X L AXIS X-X D x B1 x B2 Weight Ix Sx RX Ma (in.) Section Ga. (PLF) (in.4/ft.) (in.3/ft.) (in.) (in.-kips) 4 x 2 x 2 Zee 16 1.793 1.375 0.688 1.615 23.473 4 x 2.125 x 2.375 Zee 16 1.793 1.277 0.561 1.556 19.153 3.5 x 1.5 x 1.5 Zee 16 1.592 0.876 0.500 1.367 17.075 6 x 2.125 x 2.375 Zee 16 2.395 3.948 1.344 2.368 45.866 8 x 2.125 x 2.375 Zee 16 2.796 7.759 1.975 3.072 67.407 D X B X L AXIS X-X D x B Weight Ix Sx RX Ma (in.) Section Ga. (PLF) (in.4/ft.) (in.3/ft.) (in.) (in.-kips) 4 x 2.25 Cee 16 1.994 1.560 0.780 1.631 26.616 4 x 2.5 Cee 16 1.581 1.261 0.630 1.647 21.503 6 x 2.5 Cee 16 2.395 3.971 1.324 2.375 45.180 8 x 2.5 Cee 16 2.796 7.791 1.948 3.078 66.482 CS-1 Cee 18 0.815 0.116 0.138 0.694 4.717 AXIS X-X D x B Weight Ix Sx RX Ma (in.) Section Ga. (PLF) (in.4/ft.) (in.3/ft.) (in.) (in.-kips) HS-1 Hat 16 1.276 0.130 1.673 0.588 57.089 D X B X AXIS X-X D x B Weight Ix Sx RX Ma (in.) Section Ga. (PLF) (in.4/ft.) (in.3/ft.) (in.) (in.-kips) 4.125 x 2 Channel 16 1.592 1.273 0.617 1.649 21.070 6.125 x 2 Channel 16 1.994 3.197 1.044 2.335 35.627 8.125 x 2 Channel 16 2.395 6.293 1.549 2.989 52.870 D X B X AXIS X-X D x B Weight Ix Sx RX Ma (in.) Section Ga. (PLF) (in.4/ft.) (in.3/ft.) (in.) (in.-kips) 2 x 2 Angle 16 0.772 0.093 0.173 0.639 5.906 2.5 x 1.5 Angle 22 0.382 0.077 0.096 0.827 3.272 NOTES: 1. All calculations for the properties of cees and zees are calculated in accordance with the 2001 North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute (A.I.S.I). 2. Ixe is for deflection determination. 3. Sx is for bending. 4. Maxo is allowable bending moment. 5. The allowable bending moment (Ma) assumes that the compressive flange is laterally braced so as to provide the full moment capacity of the section. The Engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer. NR-8 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DESIGN INFORMATION FRAMING OVER MEMBERS PARALLEL TO THE ROOF SLOPE (Base Channel Attachment) BASE CHANNEL FRAMEWORK SPACING DETERMINED BY SPACING SPACING DETAIL 1 FASTENER TO (NOT BY MBCI) A BASE CHANNEL PLAN VIEW BASE CHANNEL ATTACHMENT BASE CHANNEL A DETAIL 1 CROSS SECTION A-A BASE CHANNEL ATTACHMENT FASTENER TO (NOT BY MBCI) SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-9

DESIGN INFORMATION FRAMING OVER MEMBERS PARALLEL TO THE ROOF SLOPE (Column Attachment) BASE CHANNEL SPACING DETERMINED BY SPACING DETAIL 1 SPACING FRAMEWORK FASTENER TO (NOT BY MBCI) A DETAIL 1 A BASE CHANNEL PLAN VIEW ATTACHMENT CROSS SECTION A-A ATTACHMENT BASE CHANNEL FASTENER TO (NOT BY MBCI) NR-10 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DESIGN INFORMATION FRAMING OVER MEMBERS PARALLEL TO THE ROOF SLOPE ( X Bracing Attachment) LONGITUDINAL ANGLE BRACING BASE CHANNEL TRANSVERSE ANGLE BRACING (EVERY 40 MIN.) FRAMEWORK SPACING DETERMINED BY SPACING DETAIL 1 SPACING ANGLE BRACING FIELD NOTCH ANGLE BRACE ANGLE BRACING BASE CHANNEL A ANGLE BRACING ANGLE BRACING BASE CHANNEL A DETAIL 1 FASTENER TO (NOT BY MBCI) CROSS SECTION A-A ANGLE BRACE ATTACHMENT SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-11

DESIGN INFORMATION FRAMING OVER MEMBERS PARALLEL TO THE ROOF SLOPE (Purlin Attachment) NOTE: LAPS MUST OCCUR AT A LOCATION 6 BASE CHANNEL SPACING DETERMINED BY SPACING LONGITUDINAL ANGLE BRACING ANGLE BRACING BASE CHANNEL A DETAIL 1 ANGLE BRACING SPACING ANGLE BRACING FRAMEWORK 4:12 3:12 2:12 1:12 FLANGE CAN BE ROLL FORMED TO A MAXIMUM SLOPE OF 4:12 TRANSVERSE ANGLE BRACING (EVERY 40 MIN.) BASE CHANNEL A DETAIL 1 CROSS SECTION A-A ATTACHMENT FASTENER TO (NOT BY MBCI) NR-12 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DESIGN INFORMATION FRAMING OVER MEMBERS PARALLEL TO THE ROOF SLOPE (Strut Attachment) CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) BASE CHANNEL SPACING DETERMINED BY SPACING ANGLE BRACING LONGITUDINAL ANGLE BRACING CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) BASE CHANNEL A DETAIL 1 ANGLE BRACING ANGLE BRACING SPACING TRANSVERSE ANGLE BRACING (EVERY 40 MIN.) FRAMEWORK CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) BASE CHANNEL A DETAIL 1 CROSS SECTION A-A STRUT ATTACHMENT FASTENER TO (NOT BY MBCI) SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-13

DESIGN INFORMATION FRAMING OVER MEMBERS PARALLEL TO THE ROOF SLOPE (Panel Attachment) ROOF PANEL BASE CHANNEL SPACING DETERMINED BY SPACING ANGLE BRACING ROOF PANEL LONGITUDINAL ANGLE BRACING BASE CHANNEL A DETAIL 1 ROOF CONTINUOUS PANEL CHANNEL SECTION (EVERY BRACED LINE) SPACING ROOF PANEL CLIP ANGLE BRACING ANGLE BRACING FRAMEWORK TRANSVERSE ANGLE BRACING (EVERY 40 MIN.) CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) BASE CHANNEL A DETAIL 1 CROSS SECTION A-A PANEL ATTACHMENT FASTENER TO (NOT BY MBCI) NR-14 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DESIGN INFORMATION FRAMING OVER MEMBERS PERPENDICULAR TO THE ROOF SLOPE (Base Zee Attachment) NOTE: LAPS MUST OCCUR AT A LOCATION 6 SPACING TRANSVERSE ANGLE BRACING (EVERY 40 MIN.) SPACING LONGITUDINAL ANGLE BRACING DETAIL 1 FRAMEWORK SPACING 4:12 3:12 2:12 1:12 FLANGE CAN BE ROLL FORMED TO A MAXIMUM SLOPE OF 4:12 ANGLE BRACING A FASTENER TO (NOT BY MBCI) DETAIL 1 A (4) REQ D. ANGLE BRACING (4) REQ D. FASTENER TO (NOT BY MBCI) CROSS SECTION A-A ATTACHMENT SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-15

DESIGN INFORMATION FRAMING OVER MEMBERS PERPENDICULAR TO THE ROOF SLOPE (Column Attachment) SPACING A SPACING FASTENER TO (NOT BY MBCI) DETAIL 1 A (4) REQ D. DETAIL 1 PLAN VIEW ATTACHMENT FRAMEWORK SPACING (4) REQ D. FASTENER TO (NOT BY MBCI) (4) REQ D. FASTENER TO (NOT BY MBCI) CROSS SECTION A-A ATTACHMENT NR-16 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DESIGN INFORMATION FRAMING OVER MEMBERS PERPENDICULAR TO THE ROOF SLOPE ( X Bracing Attachment) LONGITUDINAL ANGLE BRACING SPACING TRANSVERSE ANGLE BRACING (EVERY 40 MIN.) SPACING DETAIL 1 SPACING FRAMEWORK ANGLE BRACING A FASTENER TO (NOT BY MBCI) A DETAIL 1 ANGLE BRACING (4) REQ D. ANGLE BRACING (FIELD NOTCH) ANGLE BRACING (4) REQ D. FASTENER TO (NOT BY MBCI) CROSS SECTION A-A ANGLE BRACE ATTACHMENT SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-17

DESIGN INFORMATION FRAMING OVER MEMBERS PERPENDICULAR TO THE ROOF SLOPE (Purlin Attachment) NOTE: LAPS MUST OCCUR AT A LOCATION 6 SPACING TRANSVERSE ANGLE BRACING (EVERY 40 MIN.) SPACING LONGITUDINAL ANGLE BRACING DETAIL 1 FRAMEWORK SPACING 4:12 3:12 2:12 1:12 FLANGE CAN BE ROLL FORMED TO A MAXIMUM SLOPE OF 4:12 ANGLE BRACING A FASTENER TO (NOT BY MBCI) DETAIL 1 A (4) REQ D. ANGLE BRACING (4) REQ D. FASTENER TO (NOT BY MBCI) CROSS SECTION A-A ATTACHMENT NR-18 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DESIGN INFORMATION FRAMING OVER MEMBERS PERPENDICULAR TO THE ROOF SLOPE (Strut Attachment) SPACING TRANSVERSE ANGLE BRACING (EVERY 40 MIN.) CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) ANGLE BRACING A SPACING FASTENER TO (NOT BY MBCI) LONGITUDINAL ANGLE BRACING DETAIL 1 A CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) (4) REQ D. DETAIL 1 FRAMEWORK CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) ANGLE BRACING SPACING CROSS SECTION A-A STRUT ATTACHMENT (4) REQ D. FASTENER TO (NOT BY MBCI) SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-19

DESIGN INFORMATION FRAMING OVER MEMBERS PERPENDICULAR TO THE ROOF SLOPE (Panel Attachment) ROOF PANEL TRANSVERSE ANGLE BRACING (EVERY 40 MIN.) CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) ANGLE BRACING SPACING ROOF PANEL LONGITUDINAL ANGLE BRACING (4) REQ D. DETAIL 1 CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) A FRAMEWORK ROOF PANEL ANGLE BRACING (4) REQ D. SPACING CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) FASTENER FASTENER TO (NOT BY MBCI) A DETAIL 1 FASTENER TO (NOT BY MBCI) CROSS SECTION A-A PANEL ATTACHMENT NR-20 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DESIGN INFORMATION FRAMING OVER MEMBERS (Gable Endwall Girt Attachment) A ENDWALL GIRT HAT SECTION RAKE ANGLE ISOMETRIC VIEW OF ENDWALL BASE CHANNEL A PANCAKE HEAD SELF DRILLERS (2 PER CONN.) RAKE ANGLE (2) REQ D. BASE CHANNEL ENDWALL GIRT HAT SECTION CROSS SECTION A-A ENDWALL ATTACHMENT FASTENER TO (NOT BY MBCI) SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-21

DESIGN INFORMATION FRAMING FOR ROOF HIP (Back-to-Back Hip Channel Attachment) LONGITUDINAL ANGLE BRACING TRANSVERSE ANGLE BRACING (EVERY 40 MIN.) 4¹ ₈ x 2 HIP CHANNEL (BACK TO BACK) CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) BASE CHANNEL FRAMEWORK DETAIL 1 4¹ ₈ x 2 HIP CHANNEL (BACK TO BACK) 4¹ ₈ x 2 HIP CHANNEL (BACK TO BACK STITCHED @ 12 O.C.) (2) PANCAKE HEAD SELF DRILLERS 12 O.C. STAGGERED HIP CHANNEL BACK TO BACK (2) PANCAKE HEAD SELF DRILLERS DETAIL 1 NR-22 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DESIGN INFORMATION FRAMING FOR ROOF VALLEY (Back-to-Back Valley Channel Attachment) 4¹ ₈ x 2 VALLEY CHANNEL (BACK TO BACK) LONGITUDINAL ANGLE BRACING TRANSVERSE ANGLE BRACING (EVERY 40 MIN.) DETAIL 1 CONTINUOUS CHANNEL SECTION (EVERY BRACED LINE) FRAMEWORK BASE CHANNEL 4¹ ₈ x 2 VALLEY CHANNEL (BACK TO BACK) 12 O.C. 4¹ ₈ x 2 VALLEY CHANNEL (BACK TO BACK STITCHED @ 12 O.C.) (2) PANCAKE HEAD SELF DRILLERS STAGGERED VALLEY CHANNEL BACK TO BACK (2) PANCAKE HEAD SELF DRILLERS DETAIL 1 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-23

DESIGN INFORMATION FRAMING FOR ROOF RIDGE (Peak Framing Attachment) CONTINUOUS CHANNEL SECTION BASE CHANNEL A RIDGE SUPPORT CHANNEL SECTION A ISOMETRIC VIEW OF ENDWALL CONTINUOUS CHANNEL SECTION RIDGE SUPPORT CHANNEL SECTION BASE CHANNEL CROSS SECTION A-A STRUT ATTACHMENT FASTENER TO (NOT BY MBCI) NR-24 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DETAILS BASE CHANNEL CONNECTION WITH ATTACHMENT (Flange Connection) 4 CEE 4¹ ₈ x 2 CHANNEL x 1-0 (BASE SHOE) 2 x 2 ANGLE (SEE PLAN (2) PER SIDE, (4) TOTAL 4 CEE 4¹ ₈ x 2 CHANNEL x 1-0 (BASE SHOE) 2 x 2 ANGLE (SEE PLAN (2) PER SIDE, (4) TOTAL ROOF SYSTEM BASE SHOE FASTENER (MIN. QTY. 4, NOT BY MBCI) ROOF SYSTEM BASE SHOE FASTENER (MIN. QTY. 4, NOT BY MBCI) 8 MAX. CONNECTION WITH ATTACHMENT (Flange Connection) 4 CEE (4) TOTAL 2 x 2 ANGLE (SEE PLAN 4 CEE 2 x 2 ANGLE (SEE PLAN [FASTENER #1B] (4) TOTAL ROOF SYSTEM FASTENER (MIN. QTY. 2, NOT BY MBCI) FASTENER (MIN. QTY. 2, NOT BY MBCI) ROOF SYSTEM SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-25

DETAILS CONNECTION WITH ATTACHMENT (Web Connection) 4 CEE [FASTENER #1B] (4) TOTAL 2 x 2 ANGLE (SEE PLAN 4 CEE 2 x 2 ANGLE (SEE PLAN [FASTENER #1B] (4) TOTAL ROOF SYSTEM FASTENER (MIN. QTY. 2, NOT BY MBCI) FASTENER (MIN. QTY. 2, NOT BY MBCI) ROOF SYSTEM CONNECTION (Lap Connection) 6 (4) TOTAL (4) TOTAL 3 3 1 1 1 ROOF SYSTEM FASTENER (MIN. QTY. 2, NOT BY MBCI) FASTENER (MIN. QTY. 2, NOT BY MBCI) C L ROOF SYSTEM NR-26 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DETAILS HIGH STRENGTH -CLIP ANGLE CONNECTION WITH ATTACHMENT (Flange Connection) 4 CEE ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (4) TOTAL 2 x 2 ANGLE (SEE PLAN CLIP ANGLE CLIP ANGLE 4 CEE [FASTENER #1B] [FASTENER #1B] (4) TOTAL 2 x 2 ANGLE (SEE PLAN FOR EXACT LOCATION) ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (4) TOTAL ROOF SYSTEM ANGLE CLIP FASTENER (MIN. QTY. 2, NOT BY MBCI) FASTENER (MIN. QTY. 2, NOT BY MBCI) ANGLE CLIP FASTENER (MIN. QTY. 2, NOT BY MBCI) ROOF SYSTEM HIGH STRENGTH -CLIP ANGLE CONNECTION WITH ATTACHMENT (Web Connection) 4 CEE ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (4) TOTAL 2 x 2 ANGLE (SEE PLAN CLIP ANGLE CLIP ANGLE 4 CEE [FASTENER #1B] [FASTENER #1B] (4) TOTAL 2 x 2 ANGLE (SEE PLAN FOR EXACT LOCATION) ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (4) TOTAL ROOF SYSTEM ANGLE CLIP FASTENER (MIN. QTY. 2, NOT BY MBCI) FASTENER (MIN. QTY. 2, NOT BY MBCI) ANGLE CLIP FASTENER (MIN. QTY. 2, NOT BY MBCI) ROOF SYSTEM SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-27

DETAILS TO ATTACHMENT (Flange Connection) ZEE (4) TOTAL (4) TOTAL ZEE CS-1 STRUT ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] 4 CEE CS-1 STRUT 2 x 2 ANGLE (SEE PLAN 4 CEE 2 x 2 ANGLE (SEE PLAN TO ATTACHMENT (Flange Connection With Purlin Clip) 3 x 3 CLIP ANGLE ZEE (4) TOTAL ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (4) TOTAL 3 x 3 CLIP ANGLE ZEE CS-1 STRUT ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] 4 CEE CS-1 STRUT 2 x 2 ANGLE (SEE PLAN 4 CEE 2 x 2 ANGLE (SEE PLAN TO ATTACHMENT (Flange Connection at Purlin Lap) 6 ZEE 3 C L 3 ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (8) TOTAL ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (8) TOTAL ZEE CS-1 STRUT ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] 4 CEE CS-1 STRUT 2 x 2 ANGLE (SEE PLAN ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] 4 CEE 2 x 2 ANGLE (SEE PLAN NR-28 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DETAILS TO ATTACHMENT (Web Connection) ZEE (4) TOTAL ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (4) TOTAL ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] ZEE CS-1 STRUT ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] 4 CEE CS-1 STRUT 2 x 2 ANGLE (SEE PLAN ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] 4 CEE 2 x 2 ANGLE (SEE PLAN FOR EXACT LOCATION) TO ATTACHMENT (Web Connection With Purlin Clip) ZEE 3 x 3 CLIP ANGLE (4) TOTAL ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (4) TOTAL 3 x 3 CLIP ANGLE ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] ZEE CS-1 STRUT ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] 4 CEE CS-1 STRUT 2 x 2 ANGLE (SEE PLAN ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] 4 CEE 2 x 2 ANGLE (SEE PLAN FOR EXACT LOCATION) TO ATTACHMENT (Web Connection at Purlin Lap) ZEE 3 6 CL 3 (8) TOTAL ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (8) TOTAL ¹ ₄ -14 x 1¹ ₄ S.D [FASTENER #1B] ZEE CS-1 STRUT ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] 4 CEE CS-1 STRUT 2 x 2 ANGLE (SEE PLAN ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] 4 CEE 2 x 2 ANGLE (SEE PLAN FOR EXACT LOCATION) SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-29

DETAILS LONGITUDINAL ANGLE BRACING (Parallel to Purlins) (4) PER CONN. ZEE FIELD NOTCH ANGLE AS REQUIRED 2 x 2 ANGLE (SEE PLAN CS-1 STRUT 4 CEE 4¹ ₈ x 2 CHANNEL x 1-0 (BASE SHOE) (2) PER SIDE, (4) TOTAL FIELD NOTCH ANGLE AS REQUIRED ROOF SYSTEM BASE SHOE FASTENER (MIN. QTY. 4, NOT BY MBCI) (4) PER CONN. ZEE 2 x 2 ANGLE (SEE PLAN CS-1 STRUT 4 CEE (4) PER CONN. ROOF SYSTEM FASTENER (MIN. QTY. 2, NOT BY MBCI) NR-30 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DETAILS TRANSVERSE ANGLE BRACING (Perpendicular to Purlins) ZEE (4) PER CONN. ZEE CS-1 STRUT 4 CEE 2 x 2 ANGLE (SEE PLAN (2) PER SIDE, (4) TOTAL 4¹ ₈ x 2 CHANNEL x 1-0 (BASE SHOE) ROOF SYSTEM BASE SHOE FASTENER (MIN. QTY. 4, NOT BY MBCI) ZEE ZEE (4) PER CONN. CS-1 STRUT 4 CEE FIELD NOTCH ANGLE AS REQUIRED 2 x 2 ANGLE (SEE PLAN (4) PER CONN. FIELD NOTCH ANGLE AS REQUIRED ROOF SYSTEM FASTENER (MIN. QTY. 2, NOT BY MBCI) SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-31

DETAILS DOUBLE LONGITUDINAL ANGLE BRACING (Parallel to Purlins With Base Shoe) (4) PER CONN. ZEE FIELD NOTCH ANGLE AS REQUIRED 2 x 2 ANGLE (SEE PLAN CS-1 STRUT 4 CEE FIELD NOTCH ANGLE AS REQUIRED CS-1 STRUT 2 x 2 ANGLE (SEE PLAN FIELD NOTCH ANGLE AS REQUIRED 4¹ ₈ x 2 CHANNEL x 1-0 (BASE SHOE) (2) PER SIDE, (4) TOTAL FIELD NOTCH ANGLE AS REQUIRED ROOF SYSTEM BASE SHOE FASTENER (MIN. QTY. 4, NOT BY MBCI) NR-32 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DETAILS DOUBLE LONGITUDINAL ANGLE BRACING (Parallel to Purlins With Base Zee) (4) PER CONN. ZEE 2 x 2 ANGLE (SEE PLAN CS-1 STRUT 4 CEE CS-1 STRUT 2 x 2 ANGLE (SEE PLAN ROOF SYSTEM FASTENER (MIN. QTY. 2, NOT BY MBCI) (4) PER CONN. SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-33

DETAILS DOUBLE TRANSVERSE ANGLE BRACING (Perpendicular to Purlins With Base Shoe) ZEE (4) PER CONN. ZEE CS-1 STRUT 4 CEE 2 x 2 ANGLE (SEE PLAN CS-1 STRUT 2 x 2 ANGLE (SEE PLAN (2) PER SIDE, (4) TOTAL 4¹ ₈ x 2 CHANNEL x 1-0 (BASE SHOE) ROOF SYSTEM BASE SHOE FASTENER (MIN. QTY. 4, NOT BY MBCI) NR-34 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DETAILS DOUBLE TRANSVERSE ANGLE BRACING (Perpendicular to Purlins With Base Zee) ZEE ZEE (4) PER CONN. CS-1 STRUT 4 CEE FIELD NOTCH ANGLE AS REQUIRED 2 x 2 ANGLE (SEE PLAN FIELD NOTCH ANGLE AS REQUIRED FIELD NOTCH ANGLE AS REQUIRED CS-1 STRUT 2 x 2 ANGLE (SEE PLAN (4) PER CONN. FIELD NOTCH ANGLE AS REQUIRED ROOF SYSTEM FASTENER (MIN. QTY. 2, NOT BY MBCI) SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-35

DETAILS EAVE OVERHANG (With Parapet Wall) ZEE ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (4) PER CONN. CS-1 STRUT ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (4) PER CONN. EAVE STRUT CLIP 4 CEE OUTRIGGER 4 CEE EAVE STRUT HAT SECTION (2) PER SIDE, (4) TOTAL (4) PER CONN. 4¹ ₈ x 2 CHANNEL x 1-0 (BASE SHOE) PARAPET WALL ROOF SYSTEM BASE SHOE FASTENER (MIN. QTY. 4, NOT BY MBCI) EAVE DETAILS EAVE CHANNEL 4 CEE HAT SECTION (4) PER CONN. EAVE ANGLE 4 12 x 1 PANCAKE SELF-DRILLER [FASTENER #12A] @ 12 O.C. EAVE ANGLE ROOF SYSTEM FASTENER (MIN. QTY. 2, NOT BY MBCI) BASE ANGLE FASTENER @ 12 O.C. (NOT BY MBCI) ROOF SYSTEM EAVE WITH FASCIA WALL EAVE WITH ANGLES NR-36 REV 00.00 SUBJECT TO CHANGE SEE WITHOUT www.mbci.com NOTICE FOR SEE CURRENT www.mbci.com INFORMATION CURRENT INFORMATIONSUBJECT TO CHANGE EFFECTIVE WITHOUT DECEMBER NOTICE 18, 2007

DETAILS EDGE/CORNER ZONE (For Use in High Wind Condition) ZEE ZEE ¹ ₄ -14 x 1¹ ₄ S.D. [FASTENER #1B] (4) PER CONN. 4 CEE BRIDGING (2) PER SIDE, (4) TOTAL (4) PER CONN. 4 CEE 4¹ ₈ x 2 CHANNEL x 1-0 (BASE SHOE) ROOF SYSTEM BASE SHOE FASTENER (MIN. QTY. 4, NOT BY MBCI) SUBJECT EFFECTIVE TO DECEMBER CHANGE 18, WITHOUT 2007 NOTICE SEE www.mbci.com SEE FOR CURRENT FOR INFORMATION CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE REV 00.00 NR-37

DESIGN INFORMATION ARCHITECT/ENGINEER INFORMATION (Optional Method) 1. The optional NuRoof Retrofit Systems are designed to go directly over existing sloped roof systems. 2. The optional NuRoof Grid System allows for additional purlins to be installed when the existing purlin spacing does not meet the current code requirements. 3. The optional NuRoof Retrofit System over existing PBR requires the use of the MBCI Ultra-Dek or Double-Lok roof systems. The high clips used with these systems elevate the roof system 1³ ₈ over the existing structure, allowing the panels to pass over a standard 1¹ ₄ PBR panel. If the existing roof system has a rib height of 1¹ ₂ a non-compressible ¹ ₄ shim can be used. 4. Care must be taken when cutting back the eave of the existing roof system to make sure no shavings land on adjacent or stored new roofing materials. Hot shavings landing on new material can cause premature rusting of the material surface. 5. When installing the optional NuRoof Retrofit System over a PBR system the module of the existing roof system must be checked. The MBCI Ultra-Dek /Double-Lok roof systems hold a 24 module and if the existing roof was stretched ahead or shrunk back the clips will eventually foul into an existing major rib. An 18 panel can be installed in lieu of a 24 panel to allow the new roof system to stay on the module created by the existing roof panels. INSTALLATION GUIDELINES 1. Pre-Order a. Prior to ordering panels, all dimensions should be confirmed by field measurements. 2. Jobsite Storage and Handling a. Check the shipment against the shipping list. b. Damaged material must be noted on Bill of Lading. c. Materials should be handled carefully. A spreader bar of appropriate length is recommended for hoisting. 3. Application Checklist a. Check substrate for proper alignment and uniformity. b. Periodic check of panel alignment is crucial to proper panel installation. c. Material should be cut on the ground to minimize cut fillings on new materials. NR-38 REV 00.00 SUBJECT TO CHANGE SEE WITHOUT www.mbci.com NOTICE FOR SEE CURRENT www.mbci.com INFORMATION CURRENT INFORMATIONSUBJECT TO CHANGE EFFECTIVE WITHOUT DECEMBER NOTICE 18, 2007

DETAILS NuRoof GRID SYSTEM (Optional Method) MAIN SPACING EDGE ZONE SPACING EQUAL EQUAL SUPPORT FRAMMING EQUAL EQUAL EQUAL EQUAL EQUAL EQUAL ROOF PANEL HAT SECTION [HS-1] ATTACH TO FRAMING WITH (2) PER CONN. FRAMING HAT SECTION [HS-1] ATTACH TO SECONDARY FRAMING WITH (2) PER CONN. WALL PANEL SUBJECT EFFECTIVE TO DECEMBER CHANGE 18, WITHOUT 2007 NOTICE SEE www.mbci.com SEE FOR CURRENT FOR INFORMATION CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE REV 00.00 NR-39

DETAILS NuRoof GRID SYSTEM (Optional Method Details) HAT SECTION [HS-1] HAT SECTION [HS-1] HAT SECTION [HS-1] HAT SECTION [HS-1] ROOF PANEL ROOF PANEL CONNECTION OF HAT SECTIONS TO (SIDE VIEW) CONNECTION OF HAT SECTIONS TO (FRONT VIEW) 9 4¹ ₂ 4¹ ₂ 2 HAT SECTION [HS-1] 12 x 1 TAPER SHANK S.D. (4 EACH SIDE) CHANNEL SECTION [CS-1] SPLICE DETAIL NOTE: MUST OCCUR OVER A SUPPORT MEMBER. NR-40 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DETAILS SSR SYSTEM OVER PBR PANEL (Vented Method) PBR PANEL 2 STAND OFF SLIDING CLIP [HW-2129] FIELD CUT PANEL AT EAVE (ROOF PANEL CANNOT EXTEND BEYOND HIGH RIB OF WALL PANEL) DOUBLE-LOK PANEL MINOR RIB TAPE SEALER [HW-512] FRAMING 2 x 4 RAKE ANGLE 2 STAND OFF RAKE SUPPORT ANGLE [HW-7764] CORA VENT MATERIAL TRI-BEAD TAPE SEALER [HW-504] RETRO EAVE ANGLE BROKE TO ROOF PITCH (14 GA. GALVANIZED) ATTACH w/¹ ₄-14 x 2 TEK 3 S.D. [FASTENER #115] @ EA. HIGH RIB OF PBR PANEL METAL INSIDE CLOSURE [HW-426] WALL PANEL ¹ ₄-14 x 1 ¹ ₄ LONG-LIFE S.D. W/WASHER [FASTENER #1E] (8 PER PANEL) NOTE: MAJOR RIB OF ROOF PANEL CANNOT EXCEED 1¹ ₄ IN HEIGHT. SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-41

GUTTER STRAP [FL-246] ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] (2 PER STRAP) TRI-BEAD TAPE SEALER @ TOP OF CLOSURE [HW-504] ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] (2 PER STRAP) DETAILS SSR SYSTEM OVER PBR PANEL (Vented Eave Detail) 3 1/2 VENT MATERIAL THICKNESS WALL PANEL THICKNESS ¹ ₄-14 x 1 ¹ ₄ LONG-LIFE S.D. W/WASHER [FASTENER #1E] (8 PER PANEL) 2 LONG TRI-BEAD TAPE SEALER [HW-504] @ PANEL RIBS OVER INSIDE CLOSURE GUTTER STRAP [FL-246] @ 48 O.C. (MAX.) METAL INSIDE CLOSURE [HW-426] RETRO EAVE ANGLE (14 GA. GALVANIZED) BROKE TO ROOF PITCH INSTALLATION NOTE: 1. FIELD CUT PANEL AT EAVE. ( ROOF PANEL CANNOT EXTEND BEYOND HIGH RIB OF WALL PANEL) 2. INSTALL RETRO EAVE ANGLE ALONG CUT END OF PANEL THAT HAS BEEN CUT BACK. ATTACH INTO EACH HIGH RIB OF THE PANEL AND INTO EAVE STRUT BELOW. 3. CLIPS FOR DOUBLE-LOK PANEL MUST BE LAYED OUT TO FALL CENTERED IN BETWEEN THE HIGH RIBS OF THE PANEL. 4. APPLY TRI-BEAD TAPE SEALER CONTINUOUS ALONG RETRO EAVE ANGLE. 5. ATTACH INSIDE METAL CLOSURE WITH ¹ ₄-14 x 1 S.D.S. W/WASHER [FASTENER #1]. 6. APPLY A 10 LONG PIECE OF TRI-BEAD TAPE SEALER UP AND OVER THE INSIDE METAL CLOSURE. 7. APPLY A 2 LONG PIECE OF TRI-BEAD TAPE SEALER IN VERTICAL LEG OF PANEL SEAM. 8. APPLY MINOR RIB TAPE SEAL BETWEEN PANEL AND EAVE TRIM OR GUTTER. 9. ATTACH PANEL WITH ¹ ₄-14 x 1¹ ₄ LONG-LIFE W/WASHER IN THE FLAT PANEL AND ONE EACH SIDE OF THE INSIDE METAL CLOSURE (8) TOTAL [FASTENER #1E]. DOUBLE-LOK PANEL MINOR RIB TAPE SEALER AT ALL MINOR RIBS [HW-512] 2 PREPUNCHED HOLES IN PANEL ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] @ 12 O.C. SCULPTURED GUTTER CORA VENT MATERIAL WALL PANEL PBR PANEL (FIELD CUT PANEL AT EAVE) ¹ ₄-14 x 2 TEK 3 S.D. [FASTENER #115] @ EA. HIGH RIB OF PBR PANEL TRI-BEAD TAPE SEALER [HW-504] ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] (2 PER INSIDE CLOSURE) EAVE STRUT SSR SYSTEM OVER PBR PANEL (Vented Clip Attachment Detail) 2 STAND OFF SLIDING CLIP [HW-2129] DOUBLE-LOK PANEL 2 PBR PANEL ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] (2 PER CLIP) NR-42 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DETAILS SSR SYSTEM OVER PBR PANEL (Vented Rake Detail) BUILDING DIM. 6 TRI-BEAD TAPE SEALER [HW-504] 2 STAND OFF RAKE SUPPORT ANGLE [HW-7664] ¹ ₄-14 x 1 ¹ ₄ LONG-LIFE S.D. W/WASHER [FASTENER #1E] @ 24 O.C. ¹ ₄-14 x 1 ¹ ₄ SHOULDER TEK 2 SELF-DRILLER [FASTENER #5] @ 24 O.C. (CENTER IN SLOT) SCULPTURED RAKE TRIM DOUBLE-LOK PANEL 2 PBR PANEL RAKE SLIDE [FL-115] 2 x 4 RAKE ANGLE ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] (2 @ EA. ) ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] @ 12 O.C. FOAM CLOSURE WALL PANEL SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-43

DETAILS SSR SYSTEM OVER PBR PANEL (Vented Rake Detail W/Termination) ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] @ 12 O.C. RETRO-FIT RAKE TRIM [FL-_] FURRING ZEE [FL-_] 2 STAND OFF RAKE SUPPORT ANGLE [HW-7664] TRI-BEAD TAPE SEALER [HW-504] BUILDING DIM. 6 VARIABLE TERMINATION TRIM [FL-117] TRI-BEAD TAPE SEALER [HW-504] ¹ ₄-14 x 1 ¹ ₄ LONG-LIFE S.D. W/WASHER [FASTENER #1E] @ 24 O.C. ¹ ₄-14 x 1 ¹ ₄ SHOULDER TEK 2 SELF-DRILLER [FASTENER #5] @ 24 O.C. (CENTER IN SLOT) DOUBLE-LOK PANEL 2 RAKE SLIDE [FL-115] PBR PANEL 2 x 4 RAKE ANGLE ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] (2 @ EA. ) ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] @ 12 O.C. FOAM CLOSURE ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] @12 O.C. WALL PANEL NR-44 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DETAILS SSR SYSTEM OVER PBR PANEL (Vented Ridge Detail) ROOF PITCH TRI-BEAD TAPE SEALER [HW-504] 2 STAND OFF SLIDING CLIP [HW-2129] DOUBLE-LOK PANEL 12 1-0 MAX. 2 5 RIDGE FLASHING PERFORATED VENT DRIP [FL-254] DIE-FORMED RIDGE CAP 12 ROOF PITCH ¹ ₄-14 x 1 ¹ ₄ LONG-LIFE S.D. W/WASHER [FASTENER #1E] (3 PER PANEL) ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] @ 6 O.C. ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] @ 24 O.C. DOUBLE-LOK PANEL MODIFIED BACKUP PLATE [HW-7760] 24 PANEL 2 ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] (2 PER CLIP) OUTSIDE CLOSURE [HW-430] 24 PANEL TRI-BEAD TAPE SEALER CONT. ACROSS PANEL [HW-504] ¹ ₄-14 x ⁵ ₈ LONG-LIFE TYPE B W/WASHER [FASTENER #46] (6 PER PANEL LOCATED IN PREPUNCHED HOLES IN PAN OF PANEL) PBR PANEL SUBJECT NR-45 TO CHANGE SUBJECT WITHOUT TO NOTICE CHANGE WITHOUT NOTICE SEE www.mbci.com SEE www.mbci.com FOR CURRENT FOR CURRENT INFORMATION EFFECTIVE REV 00.00 DECEMBER NR-45 18, 2007

DETAILS SSR SYSTEM OVER PBR PANEL (Vented EndLap Detail) ¹ ₄-14 x 1 ¹ ₄ LONG-LIFE S.D. W/WASHER [FASTENER #1E] (2 PER ENDLAP) 3/4 7 8 ¹ ₄-14 x ⁵ ₈ LONG-LIFE TYPE B W/WASHER [FASTENER #46] (6 PER PANEL LOCATED IN PREPUNCHED HOLES IN PAN OF PANEL) 1 5 4 3 2 6 FASTENER SEQUENCE @ ENDLAP 7 4 3 ¹ ₄-14 x ⁵ ₈ LONG-LIFE TYPE B W/WASHER [FASTENER #46] (6 PER PANEL LOCATED IN PREPUNCHED HOLES IN PAN OF PANEL) DOUBLE-LOK PANEL (PREPUNCHED) ROOF PITCH 12 DOUBLE-LOK PANEL (PREPUNCHED) 2 STAND OFF SLIDING CLIP [HW-2129] TRI-BEAD TAPE SEALER CONT. ACROSS PANEL [HW-504] 2 MODIFIED BACKUP PLATE [HW-7760] 24 PANEL PBR PANEL ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] (2 PER CLIP) NR-46 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DETAILS SSR SYSTEM OVER PBR PANEL (Insulated Method) PBR PANEL 2 STAND OFF SLIDING CLIP [HW-2129] FIELD CUT PANEL AT EAVE (ROOF PANEL CANNOT EXTEND BEYOND HIGH RIB OF WALL PANEL) DOUBLE-LOK PANEL FRAMING 2 x 4 RAKE ANGLE 2 STAND OFF RAKE SUPPORT ANGLE [HW-7764] MINOR RIB TAPE SEALER [HW-512] TRI-BEAD TAPE SEALER [HW-504] RETRO EAVE ANGLE BROKE TO ROOF PITCH (14 GA. GALVANIZED) ATTACH w/¹ ₄-14 x 2 TEK 3 S.D. [FASTENER #115] @ EA. HIGH RIB OF PBR PANEL 2 BLANKET INSULATION (OPTIONAL) WALL PANEL ¹ ₄-14 x 1 ¹ ₄ LONG-LIFE S.D. W/WASHER [FASTENER #1E] (8 PER PANEL) METAL INSIDE CLOSURE [HW-426] NOTE: MAJOR RIB OF ROOF PANEL CANNOT EXCEED 1¹ ₄ IN HEIGHT. SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-47

GUTTER STRAP [FL-246] ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] (2 PER STRAP) TRI-BEAD TAPE SEALER @ TOP OF CLOSURE [HW-504] ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] (2 PER STRAP) MINOR RIB TAPE SEALER AT ALL MINOR RIBS [HW-512] DETAILS SSR SYSTEM OVER PBR PANEL (Insulated Eave Detail) 3 1/2 WALL PANEL THICKNESS ¹ ₄-14 x 1 ¹ ₄ LONG-LIFE S.D. W/WASHER [FASTENER #1E] (8 PER PANEL) 2 LONG TRI-BEAD TAPE SEALER [HW-504] @ PANEL RIBS OVER INSIDE CLOSURE GUTTER STRAP [FL-246] @ 48 O.C. (MAX.) METAL INSIDE CLOSURE [HW-426] RETRO EAVE ANGLE (14 GA. GALVANIZED) BROKE TO ROOF PITCH INSTALLATION NOTE: 1. FIELD CUT PANEL AT EAVE. ( ROOF PANEL CANNOT EXTEND BEYOND HIGH RIB OF WALL PANEL) 2. INSTALL RETRO EAVE ANGLE ALONG CUT END OF PANEL THAT HAS BEEN CUT BACK. ATTACH INTO EACH HIGH RIB OF THE PANEL AND INTO EAVE STRUT BELOW. 3. CLIPS FOR DOUBLE-LOK PANEL MUST BE LAYED OUT TO FALL CENTERED IN BETWEEN THE HIGH RIBS OF THE PANEL. 4. APPLY TRI-BEAD TAPE SEALER CONTINUOUS ALONG RETRO EAVE ANGLE. 5. ATTACH INSIDE METAL CLOSURE WITH ¹ ₄-14 x 1 S.D.S. W/WASHER [FASTENER #1]. 6. APPLY A 10 LONG PIECE OF TRI-BEAD TAPE SEALER UP AND OVER THE INSIDE METAL CLOSURE. 7. APPLY A 2 LONG PIECE OF TRI-BEAD TAPE SEALER IN VERTICAL LEG OF PANEL SEAM. 8. APPLY MINOR RIB TAPE SEAL BETWEEN PANEL AND EAVE TRIM OR GUTTER. 9. ATTACH PANEL WITH ¹ ₄-14 x 1¹ ₄ LONG-LIFE W/WASHER IN THE FLAT PANEL AND ONE EACH SIDE OF THE INSIDE METAL CLOSURE (8) TOTAL [FASTENER #1E]. DOUBLE-LOK PANEL 2 BLANKET INSULATION (OPTIONAL) 2 PREPUNCHED HOLES IN PANEL ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] @ 12 O.C. SCULPTURED GUTTER PBR PANEL (FIELD CUT PANEL AT EAVE) ¹ ₄-14 x 2 TEK 3 S.D. [FASTENER #115] @ EA. HIGH RIB OF PBR PANEL TRI-BEAD TAPE SEALER [HW-504] ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] (2 PER INSIDE CLOSURE) WALL PANEL EAVE STRUT SSR SYSTEM OVER PBR PANEL (Insulated Clip Attachment Detail) 2 BLANKET INSULATION (OPTIONAL) 2 STAND OFF SLIDING CLIP [HW-2129] DOUBLE-LOK PANEL 2 PBR PANEL ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] (2 PER CLIP) NR-48 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DETAILS SSR SYSTEM OVER PBR PANEL (Insulated Rake Detail) BUILDING DIM. 6 TRI-BEAD TAPE SEALER [HW-504] 2 STAND OFF RAKE SUPPORT ANGLE [HW-7664] ¹ ₄-14 x 1 ¹ ₄ LONG-LIFE S.D. W/WASHER [FASTENER #1E] @ 24 O.C. ¹ ₄-14 x 1 ¹ ₄ SHOULDER TEK 2 SELF-DRILLER [FASTENER #5] @ 24 O.C. (CENTER IN SLOT) SCULPTURED RAKE TRIM DOUBLE-LOK PANEL 2 RAKE SLIDE [FL-115] ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] @ 12 O.C. FOAM CLOSURE PBR PANEL 2 x 4 RAKE ANGLE ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] (2 @ EA. ) 2 BLANKET INSULATION (OPTIONAL) WALL PANEL SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-49

DETAILS SSR SYSTEM OVER PBR PANEL (Insulated Rake Detail W/Termination) ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] @ 12 O.C. RETRO-FIT RAKE TRIM [FL-_] FURRING ZEE [FL-_] 2 STAND OFF RAKE SUPPORT ANGLE [HW-7664] TRI-BEAD TAPE SEALER [HW-504] BUILDING DIM. 6 VARIABLE TERMINATION TRIM [FL-117] TRI-BEAD TAPE SEALER [HW-504] ¹ ₄-14 x 1 ¹ ₄ LONG-LIFE S.D. W/WASHER [FASTENER #1E] @ 24 O.C. ¹ ₄-14 x 1 ¹ ₄ SHOULDER TEK 2 SELF-DRILLER [FASTENER #5] @ 24 O.C. (CENTER IN SLOT) DOUBLE-LOK PANEL 2 RAKE SLIDE [FL-115] ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] @ 12 O.C. FOAM CLOSURE PBR PANEL 2 x 4 RAKE ANGLE ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] (2 @ EA. ) ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] @12 O.C. 2 BLANKET INSULATION (OPTIONAL) WALL PANEL NR-50 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

DETAILS SSR SYSTEM OVER PBR PANEL (Insulated Ridge Detail) ROOF PITCH TRI-BEAD TAPE SEALER [HW-504] 2 STAND OFF SLIDING CLIP [HW-2129] DOUBLE-LOK PANEL 12 1-0 MAX. 2 5 RIDGE FLASHING DIE-FORMED RIDGE CAP 12 ROOF PITCH ¹ ₄-14 x 1 ¹ ₄ LONG-LIFE S.D. W/WASHER [FASTENER #1E] (3 PER PANEL) ¹ ₄-14 x ⁷ ₈ LONG-LIFE LAPTEK W/WASHER [FASTENER #4] @ 6 O.C. DOUBLE-LOK PANEL 2 ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] (2 PER CLIP) MODIFIED BACKUP PLATE [HW-7760] 24 PANEL OUTSIDE CLOSURE [HW-430] 24 PANEL TRI-BEAD TAPE SEALER CONT. ACROSS PANEL [HW-504] ¹ ₄-14 x ⁵ ₈ LONG-LIFE TYPE B W/WASHER [FASTENER #46] (6 PER PANEL LOCATED IN PREPUNCHED HOLES IN PAN OF PANEL) 2 BLANKET INSULATION (OPTIONAL) PBR PANEL SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-51

DETAILS SSR SYSTEM OVER PBR PANEL (Vented EndLap Detail) ¹ ₄-14 x 1 ¹ ₄ LONG-LIFE S.D. W/WASHER [FASTENER #1E] (2 PER ENDLAP) 3/4 7 8 ¹ ₄-14 x ⁵ ₈ LONG-LIFE TYPE B W/WASHER [FASTENER #46] (6 PER PANEL LOCATED IN PREPUNCHED HOLES IN PAN OF PANEL) 1 5 4 3 2 6 FASTENER SEQUENCE @ ENDLAP 7 4 3 ¹ ₄-14 x ⁵ ₈ LONG-LIFE TYPE B W/WASHER [FASTENER #46] (6 PER PANEL LOCATED IN PREPUNCHED HOLES IN PAN OF PANEL) DOUBLE-LOK PANEL (PREPUNCHED) ROOF PITCH 12 DOUBLE-LOK PANEL (PREPUNCHED) 2 STAND OFF SLIDING CLIP [HW-2129] TRI-BEAD TAPE SEALER CONT. ACROSS PANEL [HW-504] 2 BLANKET INSULATION (OPTIONAL) 2 MODIFIED BACKUP PLATE [HW-7760] 24 PANEL PBR PANEL ¹ ₄-14 x 1 SELF-DRILLER W/WASHER [FASTENER #1] (2 PER CLIP) NR-52 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

NOTES SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-53

NOTES NR-54 REV 00.00 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE

NOTES SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.00 NR-55

For the most current information available, visit our Web site at www.mbci.com Houston, TX 14031 West Hardy P.O. Box 38217 Houston, TX 77238 281-407-6915 Adel, GA 1601 Rogers Road P.O. Box 1107 Adel, GA 31620 888-514-6062 Atlanta, GA 2280 Monier Avenue P.O. Box 44729 Atlanta, GA 30336 678-337-1619 Atwater, CA 550 Industry Way P.O. Box 793 Atwater, CA 95301 209-445-3891 Ennis TX 1804 Jack McKay Blvd. P.O. Box 1210 Ennis, TX 75120 469-256-8255 Indianapolis, IN 1780 McCall Drive P.O. Box 657 Shelbyville, IN 46176 317-364-4329 Lubbock, TX 5711 East FM-40 P.O. Box 10133 Lubbock, TX 79408 806-224-2724 Memphis, TN 300 Highway 51 North P.O. Box 366 Hernando, MS 38632 662-298-2337 Oklahoma City, OK 7000 S. Eastern Avenue P.O. Box 95998 Oklahoma City, OK 73149 405-492-6968 Omaha, NE 1011 Ellison Avenue Omaha, NE 68110 402-983-8006 Phoenix, AZ 660 South 91st Avenue P.O. Box 739 Tolleson, AZ 85353 480-630-3022 Rome, NY 6168 State Route 233 P.O. Box 4141 Rome, NY 13442 315-371-4330 Salt Lake City, UT 1155 West 2300 North P.O. Box 16027 Salt Lake City, UT 84116 385-715-2952 San Antonio, TX 8677 I-10 East P.O. Box 69 Converse, TX 78109 210-888-9768 November 3, 2017 / Rev 00.00