PRECAST RECTANGULAR CHAMBERS

Similar documents
0.75 " transparent hose w/ valve for head measurements fixed to screws 20 MIL PVC liner. 6" gate valve

APPLICABILITY TABLE. Council BSC CHRC GRC IRC LSC MRC RRC Applicable Yes Yes Yes Yes Yes Yes Yes

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

Below ground System of pipework required to carry waste fluids from building to disposal site.

Facility Sanitary Sewers

SANITARY MANHOLE S-1 ENGINEERING DEPARTMENT PLATE NUMBER NEENAH R-1733 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL.

AMENDMENTS TO OPSS 408 (OCT 89) CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MANHOLES, CATCH BASINS, DITCH INLETS AND VALVE CHAMBERS

SECTION PRECAST CONCRETE MANHOLES

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

COLDSTREAMCONCRETE.COM

COLDSTREAMCONCRETE.COM

CPM Concrete Drainage Systems

SECTION FACILITY SANITARY SEWERS

PERMANENT PAVEMENT REPAIR NO SCALE

Pipe to Manhole Connectors, Sealants. Pipe to Manhole Connectors, Sealants

Storm Drainage

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY PHASE II

PRODUCT GUIDE 2019 EFFECTIVE MARCH 25, 2019

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping inside the building.

SUPPLEMENTAL DRAWINGS

CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MAINTENANCE HOLES, CATCH BASINS, DITCH INLETS, AND VALVE CHAMBERS

PRECAST CONCRETE MANHOLES. A. Precast concrete manholes for sanitary sewers, storm sewers, and water lines.

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

POLYETHYLENE LINED PRODUCTS PROJECTS TABLE OF CONTENTS IMPACT BAFFLES CATCH BASINS MANHOLE MATERIALS LARGE DIAMETER ROUND MANHOLES

FLOOR AND AREA DRAINS

Description Unit Quantity Rate Kshs. Amount Kshs.

CONSTRUCTION SPECIFICATION FOR NEW MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

SECTION STORM DRAINAGE

SANITARY WASTE AND VENT PIPING

B. Fiberglass for construction in back lot easements placed on cast-in-place base.

Miscellaneous and Cast Iron Listings

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER

CI/SfB Oct 12 (52.5) Uniclass L7314

ITEM No. D E S C R I P T I O N UNIT QTY. 5-E343.2 In class III material m³ 1,260 - Max. Depth: m For disposal

DIVISION 3: SEWER. Improvement Design Standards City of Dundee Oregon. Division 3 : Sewer Page 1

CI/SfB Oct 12 (52.5) Uniclass L7314

CONCRETE PIPES CONCRETE PIPES FACTORY. Since Concrete. Slabs (Cover) for Cable. Trench Jacking. Jacking Pipes. Non & Reinforced. without.

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork.

New Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

Current Standard Plates including Transmittal Letters are available on the web at:

SECTION XXXX POLYMER CONCRETE PUMP STATIONS

A. Piping materials shall bear label, stamp, or other markings of specified testing agency.

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:

Central Concrete Product Limited. Product Catalogue

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details

TABLE OF CONTENTS

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures

Unit Rate. Subtotal in SDG. Site Clearing Preliminary Works. 1.0 Job. Excavation & Earth Works. Stone Masonry Works in foundation 100 M.

Rodding Eye Details. Inspection Chambers

16. Design of Pipeline Structures.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section PRECAST CONCRETE MANHOLES

Summary of the 2011 Changes

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS

Standard Specifications for Road and Bridge Construction. Adopted January 1, 2012

TYPE "A" CATCH BASIN

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water.

Light-Metal Roof Edge, Raised

SECTION 39 - MANHOLES TABLE OF CONTENTS

DRAFT. Draft Bill of Quantities. Drainage

SECTION FACILITY SANITARY SEWERS

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 7

SECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications.

Perfect Manhole Installation Manual May 2012 Rev 8 Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints

(For compliance with the new sewers for adoption regulation or building regulations part H1)

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS

50.20 Drainage Structure Design

MATERIALS STORM DRAIN PIPE TABLE OF CONTENTS

A Provide for Contractor's Office, Store etc. Sum

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

CITY OF FARGO SPECIFICATION SANITARY SEWER

Terrain HDPE. Product Guide

1.1 SECTION INCLUDES.1 Materials and installation for water mains, hydrants, valves, valve boxes, and valve chambers, including service connections.

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS

INSTALLATION. Step 6. Step 7. Step 8

SECTION 300 STORM SEWER TABLE OF CONTENTS

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 811 CONDUIT AND DRAINAGE STRUCTURES

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM

FOX METRO WATER RECLAMATION DISTRICT MANHOLE / SEWER PIPE MATERIALS AND INSTALLATION SPECIFICATIONS MATERIALS 1. PIPE & FITTINGS

Construction works for Establishment of School in Al-Najaf M 2 2,600 M 2 750

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

List of products of harmonised standards Code 28: PIPES-TANKS AND ANCILLARIES NOT IN CONTACT WITH WATER INTENDED FOR HUMAN CONSUMPTION

SV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

Inflow pipe. Drain. Drain

Construction works for Establishment of School in Al-Latifiyah. Al-Latifiyah BoQ for constructing a 6-pre-fab Classroom School

THE ADVANTAGES HDPE MANHOLES

1 Revised: 2019 Edition

Daytona Beach Pier Building Renovation Jun 2010

SUNY Genesee Community College JMZ Project No Implementation of Master Plan Projects - Phase 1 Site Improvements

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa).

Transcription:

STANDARD MODELS GENERAL ROUGH SKETCH Available for: Sewer manhole, valve chamber, trouser manhole, and pumping station. Ø60-Ø762 ADJUSTMENT RING 7-00-2-0 20-2 30-60 RING 200-30 60-60 000-220 9ø 6 FLAT REDUCER SLAB H H2 RUBBER GASKET H3 BASE H EXTRA WIDTH ON REQUEST BOTTOM H L2 L3 0 7 L 2 3 62.007 62.00 627-722 627-96

CHART AND INDEX STANDARD MODELS PRECAST RECTANGULAR CHAMBERS L L2 L3 H H2 H3 H H MODEL INTERIOR INTERIOR REDUCER HEART MAX WEIGHT /LIN. MAX WEIGHT / BOTTOM MAXIMUM LENGTH LENGTH THICKNESS SLAB CHAMFER HEIGHT METER BASE HEIGHT LIN. METER THICKNESS DIAMETER THICKNESS (kg) (kg) OF THE DUCTS RR00 00 00 7 20 2 20 2 227 300 20 900 RR0 0 0 200 20 3 20 3760 227 6700 20 30 RR20 20 20 22 20 3 20 900 227 20 00 RR20 20 20 20 300 3 20 92 227 90 300 00 RR200 00 200 20 20 3 230 6 2300 60 20 00 RR3000 2000 3000 20 20 3 230 63 2300 00 20 00 RR300 2000 300 20 20 3 230 700 2300 292 20 00 * All dimensions are in millimeters. LEGEND 2 3 6 7 Galvanized steel ladder, by section Ducts (PVC, cast iron, polyethylene, steel, R.C.P.) Sumps or drain (0ptionnal) Hoisting Cable Handling socket Polyethylene covered Rung Circular or rectangular opening (Access trap) Embedded rubber gasket according to the type and the diameter of the pipe Rubber gasket for gravitating PVC (Ø2 @ Ø300) Perforated opening for: existing pipe, pipe with pronounced slope and angle, Link-seal To determine the slope and maximum angle of the pipes, please communicate with our engineering department. 62.007 62.00 627-722 627-96

DIMENSIONS MODELS SEWER MANHOLE + Available in particular cases with a factory made benching. + Filler concrete provided and installed by the customer. + Length and width dimensions within 00 mm range. + For transportation, at least one of the exterior dimensions (width or length) must be inferior to 00 mm. Ø600 or Ø70 RING FLAT REDUCER RING BUTYL CORD Ø9 BASE FLOOR BENCHING BENCHING 62.007 62.00 627-722 627-96

DIMENSIONS MODELS TROUSER MANHOLE / MANHOLE WITH CHUTE + Filler concrete provided and installed by the customer. + Length and width dimensions within 00 mm range. + For transportation, at least one of the exterior dimensions (width or length) must be inferior to 00 mm. 600ø or 70ø BUTYL CORD HEIGHT BASE DEFLECTOR (C.S.P.) ØEXT. + 0 mm 62.007 62.00 627-722 627-96

DIMENSIONS MODELS GATE VALVE CHAMBER + Filler concrete and/or support block (if necessary) provided and installed by the customer. + Length and width dimensions within 00 mm range. + For transportation, at least one of the exterior dimensions (width or length) must be inferior to 00 mm. Ø600 or Ø70 RING FLAT REDUCER RING BUTYL CORD 7 Ø9 BASE HEIGHT 2 FLOOR DRAIN 62.007 62.00 627-722 627-96

DIMENSIONS MODELS SPILLWAY MANHOLE + Filler concrete provided and installed by the customer. + Length and width dimensions within 00 mm range. + For transportation, at least one of the exterior dimensions (width or length) must be inferior to 00 mm. VENT ACCESS TRAPS VALVE CHAMBER SLAB ACCESS TRAPS BUTYL CORD OUTLET BASE HEIGHT FLOOR EMBEDDED SLEEVE 62.007 62.00 627-722 627-96

DIMENSIONS MODELS ANGULAR CHAMBERS + Available in certain cases with a factory made benching. + Filler concrete (if needed) provided and installed by the customer. + Length and width dimensions within 00 mm range. + For transportation, at least one of the exterior dimensions (width or length) must be inferior to 00 mm. Ø600 or Ø70 BUTYL CORD RING FEMALE JOINT FOR THE CONCRETE PIPE FLAT REDUCER RING ANGLE BASE HEIGHT Ø9 MALE JOINT FOR CONCRETE PIPE FLOOR 62.007 62.00 627-722 627-96

DIMENSIONS MODELS PUMPING STATION + Filler concrete provided and installed by the customer. + Length and width dimensions within 00 mm range. + For transportation, at least one of the exterior dimensions (width or length) must be inferior to 00 mm. BRACKET BASE ACCESS TRAP BUTYL CORD ACCESS TRAP BASE BASE HEIGHT FLOOR 62.007 62.00 627-722 627-96

STEEL LADDER RUNG LADDER RUNG LADDER 3 X 6 FLAT IRON 390 3 X 6 FLAT IRON 390 0 CRENELATED STEEL BAR mm 300 c/c (type) 0 2 RUNG LADDER 3 X 6 FLAT IRON 390 0 (type) CRENELATED STEEL BAR mm 300 c/c (type) 0 0 (type) Galvanized crenelated steel bar mm ALSO AVAILABLE LOWERED RUNG COVERED WITH POLYETHYLENE (See reinforced circular concrete manholes) 3 RUNG LADDER RUNG LADDER 3 X 6 FLAT IRON 300 c/c (type) 390 0 3 X 6 FLAT IRON 390 CRENELATED STEEL BAR mm 300 c/c (type) 0 (type) CRENELATED STEEL BAR mm 0 0 (type) 62.007 62.00 627-722 627-96

TECHNICAL DATA SHEET STANDARDS The concrete, the reinforcement steel and the rubber gaskets or liners meet the standard NQ 2622-20. HANDLING The riser rings and the top slabs of Ø9 mm are provided with plastic casings embedded in the concrete. These casings are for the fasteners of the hoisting and handling equipment. The other elements of the manholes are provided with hoisting cables allowing for a secure handling of the elements in the factory and on the building site. The customer will facilitate his work by using the suitable handling harnesses for the unloading and the installation of the manhole. An inadequate handling can produce breakings, which would irremediably affect the structure of the manhole and it s watertightness. INSTALLATION GUIDELINES The surfaces of the fittings and the rubber gaskets must be clean. In accordance with the standard NQ 2622-20, the lubricant used must be the one provided by the manufacturer of the pipe. The use of another lubricant can restrain or cancel the responsibility of the manufacturer in regards to the watertightness or physical characteristics of the rubber gaskets. The abundant use of lubricant is recommended during the fitting of rings and pipes. The Ø9mm rings require a minimum of 00g of lubricant per gasket. Manholes will have to be set up according to the sequence pointed out in the workshop drawings. The riser rings will be installed according to a height diminishing order. The desired profile will be obtained according to the workshop drawings. Precautions must be taken to prevent the contact of oil or sulphur based products with the rubber gaskets, which would deteriorate and become unusable. 62.007 62.00 627-722 627-96