Endoscope Reprocessor Specification Installation Instructions

Similar documents
ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System USER MANUAL SITE REQUIREMENTS WASHER-DISINFECTOR ENDOSCOPE DISINFECTION SYSTEM - NORTH AMERICA

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System

SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

FREQUENTLY ASKED QUESTIONS FOR THE ADVANTAGE

Transposal Ultra Evacuation Unit Instructions for Use

EBS Filters. The largest automatic self-cleaning filter for fine filtration. features: up to 7200 m³/h (32000 US gpm) less than 1% of the total flow

flow rates filtration degrees water for cleaning minimum operating pressure micron less than 1% of the total flow

SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 9,000 BTUH. Rev. 1.3

MHWW-18-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 18,000 BTUH. Rev. 1.3

MHWW-12-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 12,000 BTUH. Rev. 1.3

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

Puroxi Pure Water Global Inc. Shield 500/1000 Drinking Water System (DWS)

Gerber. Scientific Products. Dear Gerber Sabre Customer:

A UCC Building permit is not required for the exceptions listed below for COMMERCIAL application: (403.42): Building construction for the following:

Product Code: OWLIB. Installation Guide. T: F: Page 1 of 7

SECTION PLUMBING DRAINAGE AND CONTAINMENT. Copyright Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved

Installation Manual. Retractable Ceiling Column Models 8301 & 8301PC

SAF Filters. The automatic self-cleaning filter - suitable for more applications than ever.

NOTES P: 888-H2O-LOGIC ( ) F:

EBS Filters. The largest automatic self-cleaning filter for fine filtration micron less than 1% of the total flow.

TYPICAL INSTALLATION INSTRUCTIONS

Customer Responsibilities

A Green Solutions Company TM ENGINEERED PRODUCTS

Integrated Model IC-36FI Design Guide

Versatile Research Heat Exchanger

Facilities Management Service and Support Function Needs

AP-25 Plasma System AP-25 PLASMA THERMAL SPRAY SYSTEM

SERVICE & MAINTENANCE. Cantel. At your service.

1 of 10

Part Numbers. Kinetico Drinking Water Systems. Revised: 07/2016 Drinking Water Systems Parts Pages Section 7 Page 1

KODIAK RECIRCULATING CHILLERS

Ice Storage Dispenser

Milk Pre-Cooler Plumbing Considerations. ATCP 65, Wisconsin Administrative Code and the 2015 PMO

MODELS: 24 SM & 24 SMSS

Water Quality Specification for Power Supplies

SAF Filters. The automatic self-cleaning filter - suitable for more applications than ever

TYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:

BURR KING FILTERPAK 4001 INSTRUCTION MANUAL BURR KING MFG. CO., INC

Glossary Irrigation Terminology

APPENDIX A CHECK-LIST FOR SCIENCE SAFETY REQUIREMENTS. (Required Minimums for Approval by the N.C. Board of Education)

BURR KING FILTERPAK 4001 INSTRUCTION MANUAL BURR KING MFG. CO., INC

Australia s largest and leading manufacturer of drinking water coolers and industrial process water chillers

WH5-2 Iron & Hydrogen Sulfide Reduction Filter Package

MODELS: 36 DB & 36 DBSS

EBS Filters. The largest automatic self-cleaning filter for fine filtration micron. 30 psi (2 bar) less than 1% of the total flow

FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS

Gerber M Series Site Requirements

Integrated Refrigeration Design Guide

Wood Casework Acid Storage

Micro Hydro Electric Generators

VACUUM VALVES AND BACKFLOW PREVENTION

SAF Filters. The automatic self-cleaning filter - suitable for more applications than ever micron less than 1% of the total flow

Installation of Vacuklav 24-B. 1 General features. Figure 1

MODELS: 475 WM & 475 WMSS

SECTION PLUMBING SPECIALTIES

PRO. Pre-Installation guide. Video. Complete Walkthrough. Scanomat Download Center. Scanomat Connection Diagram. Scanomat Architect Pack (2D/3D Files)

medixx Series Installation Guidelines medixx 50 medixx 60 medixx 70 Suitable for the following Siemens MRI Systems, or similar models:

M300 Filters. Versatile and efficient self cleaning hydraulic filters that require no external power source

Compact. Pre-Installation guide. Video. Complete Walkthrough. Scanomat Download Center. Scanomat Connection Diagram

4. Optional Auto Drain Valve Connection

WHOLE HOUSE FILTER &

VPL-3200B Residential Vertical Platform Lift Technical Specifications

MF Product Specifications

VWR Zero Air Generator Models , Installation, Operation, and Maintenance Manual. Bulletin TI-ZAG3500-L1466

4. Optional Auto Drain Valve Connection

AUTOMATED ENDOSCOPE REPROCESSOR. OER-Pro Easy. Fast. Reliable.

INSTALLATION INSTRUCTIONS

Spouts and Flow Regulators

Integrated Refrigeration Design Guide

VPL-3300B Commercial Vertical Platform Lift Technical Specifications

VACUUM VALVES AND BACKFLOW PREVENTION

TAF Series. Innovative self-cleaning high quality plastic filter for large variety of applications

Q45WQ. Water Quality Monitoring System. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Element D Services Plumbing

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

NC State University Design and Construction Guidelines Division 00 Planning & Design Space Planning

MRI Chiller Installation Guidelines

S800-Direct Flow USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

Water Supply System. Plumbing and Cross Connection Control. Cross-Connection. Connection. Plumbing Overview 9/24/

Series 5000 Analyzers Low Range Phosphate Model and High Range Phosphate Model 60001

CCSD & CCSE Series Oil/Water Separators

MODEL INSTALLATION INSTRUCTIONS

Product Catalogue. Water Quality Products. WattsIndustries.co.uk

CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters)

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

HRO-50 Water Purifier

MRI Chiller Installation Guidelines

PRO. Pre-Installation guide. Video. Complete Walkthrough. Scanomat Download Center. Scanomat Connection Diagram. Scanomat Architect Pack (2D/3D Files)

For flow rates up to 1760 gpm Uses less than 1 percent of flow water for cleaning Provides fine filtration degrees from micron.

SAF Series. Automatic self-cleaning filters, perfect for filtering poor quality water and ideal for numerous applications

SAF Series. Automatic self-cleaning filters, perfect for filtering poor quality water and ideal for numerous applications

HI-FLO METERING SYSTEMS. An Injection Solutions Company TM

INSTALLATION & OPERATING INSTRUCTIONS

Sump Pump System OEM INSTALLATION MANUAL

PUR-1241 ADDENDUM NO. 2 INVITATION TO BID GREENSAND FILTER SYSTEM AT ELK RIDGE WATER TREATMENT PLANT

SECTION PLUMBING SPECIALTIES

Transcription:

Endoscope Reprocessor Specification Installation Instructions Endoscope Reprocessing System Introduction The following document outlines the space requirements, water supply specifications, drain specifications, and electrical specifications for the installation of the MEDIVATORS CER model endoscope reprocessors. The CER-1 is capable of reprocessing a single video endoscope, while the CER-2 has dual video endoscope reprocessing capability. This document should be used as a guideline for installation requirements. Space Requirements Chassis Dimensions Height = 14 inches (31 inches with the Lid Open) Width = 22 inches Depth = 20 inches Cart Dimensions Height = 33.5 inches Width = 21.5 inches Depth = 24.5 inches Weight Approximate weight of the CER-1 is 66 pounds Approximate weight of the CER-2 is 70 pounds Counter Top Installation To install the endoscope reprocessor on a counter top, the counter top must be a minimum of 24-inches deep (from front to back) and at a comfortable working height. Ensure that there is adequate clearance between the open lid and any wall cabinets. It is necessary to cut two 2-inch holes in the counter top to allow passage of the drain pipe and chemical reservoir tubing from under the counter. Two additional holes are also necessary if the water inlet and electricity are under the counter. Cart Mounted Installation The endoscope reprocessor can be mounted on the cart which is designed to provide easy access to the chemical reservoir and water filtration system. 1

Water Supply Specifications Inlet Water Flow Minimum of 2.5 gallons per minute Water Pressure Minimum of 40 psi Maximum of 60 psi sdf Ensure water hardness is less than 12gpg (200ppm) for optimal performance. Water Temperature Cold water supply (not to exceed 110 F) Note: Endoscope manufacturers recommend that endoscopes not be exposed to temperatures above 130 F (55ºC). A shut off valve must be installed before the water pre-filtration system. It is important that the valve be mounted within the operator s reach. All fittings on the reprocessors and the pre-filter system are 3/4 male GHT. All tubing necessary to connect the water filtration system to the reprocessor is included with the system. The water filtration system can be installed in-line. Local plumbing regulations vary regarding the installation of vacuum breakers for the water inlet and backflow protection for the drain. Note: Medivators recommends that the user check local regulations regarding anti-siphon valves and vacuum breakers before attempting to install the endoscope reprocessor. Drain Specifications A 1.5-inch drainpipe placed at least 1-foot below the drain fitting of the reprocessor with no loops is necessary to ensure complete draining of fluids from the system. The drain fitting on the reprocessor is a 1.25-inch OD with 3/4-inch ID pipe thread. It is recommended that the reprocessor be installed with the 4-foot flexible drain hose that is supplied with each reprocessor Consult with local plumbing regulations for information regarding backflow protection for drain. 2

Electrical Specifications Electrical 110 VAC at 60 Hz, 4.0 amps, 1Ø 220 VAC at 50 Hz, 2.0 amps, 1Ø Fuses 110 VAC One 6.25 amp slo-blo fuse 220 VAC Two 2.5 amp slo-blo (located in the power module) Power Cord Reprocessors are supplied with one 10-foot hospital grade removable power cord Safety Classification 1, Ordinary protection The reprocessor is not suitable for use in the presence of a flammable anesthetic mixture with air or oxygen or nitrous oxide. Note: Medivators recommends surge protectors be used for protection against power spikes and surges. Note: If the electrical power outlet is adjacent to a water supply, a ground fault interrupter should be used. (Consult local electrical codes to ensure proper compliance.) 3

CER Water Filtration System NOTE: The water supply to the CER-1076 Water Filtration System should be turned off when the equipment is not in use. Pre-filtration outlet, connect to endoscope reprocessor using stainless steel hose supplied. Pre-filtration inlet, connect to incoming water supply from main or faucet using stainless steel hose supplied Figure 1. CER Water Filtration System Note: Medivators recommends that the water filtration system be installed in a convenient location within 3 feet of the endoscope reprocessor. Note: The water filtration system should be installed in an easily accessible location for disinfection of the system and changing filters. Allow enough room under the system for removal of the filters. Note: Do not mount the system near electrical outlets. Note: One water filtration system per reprocessor. 4

5

Medivators Website Resource Center Go to: www.medivators.com, Select Resource Center and User Library for detailed user guides and hook-up matrices, report forms and logs, and product bulletins Medivators Customer and Technical Support Toll Free: Phone: 1-800-444-4729 FAX: 1-866-421-7696 Manufactured in the USA by: Medivators Inc. 14605 28th Avenue North Minneapolis, MN 55447 USA Toll Free: +1.800.444.4729 www.medivators.com 2015 Medivators Inc. MS15-0002/E Medivators BV Sourethweg 11 6422PC Heerlen The Netherlands Tel: +31.45.5.471.471 Cantel Medical Asia/Pacific Pte. Ltd. 1A International Business Park #05-01 Singapore 609933 Tel: +65.6227.9698 Cantel Medical Devices (China) Co. Ltd. Unit 804-805, Innov Tower Block A, Hongmei Road, Xuhui 200233 Shanghai Tel: +86 21 60161380 Fax: +86 21 61210913