A Green Solutions Company TM ENGINEERED PRODUCTS
|
|
- Norman Wilkins
- 6 years ago
- Views:
Transcription
1 A Green Solutions Company ENGINEERED PRODUCTS
2 A Green Solutions Company Table of Contents The World Leader EZ-FLO Injection systems has proudly offered premium grade injectors, fertilizing products, and landscape supplements for over 20 years. With over 250,000 systems installed to date, EZ-FLO is the world leader in residential and commercial landscape injection. For more information on EZ-FLO SYSTEMS and MAXX PRODUCTS please Visit our website: us: Call us toll Made with Pride In The USA Green Solutions... 1 The EZ-FLO Advantage... 2 HI-FLO Metering Systems... 3 Installation Connectors... 3 Metering Gauges... 4 Enclosures... 4 Design... 4 Installation & Operation... 5 System Components... 6 Technical Specifications
3 Green Solutions EZ-FLO Fertigation Traditional fertilization is a water intensive process. EZ-FLO Systems eliminate the intensive use of water by continually administering very small amounts of products through irrigation systems, a process known as fertigation. The plants receive micro doses of nutrients and supplements increasing both the effectiveness of the water and enhancing nutrient absorption. The EZ-FLO MAXX Solutions are specially formulated to achieve a sustainable landscape solution while delivering premium results with lower product application rates than traditional methods. As an integral part of a landscape management program, EZ-FLO provides the ability to be sustainable without sacrificing results or increasing costs. Water Conservation EZ-FLO Systems and EZ-FLO MAXX Solutions are a key element for implementing a sound water conservation program. Water quality is continually diminishing and new sources of irrigation water can have toxic levels of salt and bicarbonates. Poor water quality harms plants while reducing the effectiveness of the irrigation system resulting in increasing water application. The EZ-FLO MAXX Solutions treat the water through the addition of unique products that keep drip and spray systems clean and trouble free. EZ-FLO MAXX Solutions also correct soil issues resulting in healthier root systems, healthier plants, and improved water penetration. This reduces water requirements by as much as 50%. Drip Irrigation Solutions EZ-FLO Systems have been the time tested and proven method for adding products to a drip, subsurface, and low volume irrigation system. With the EZ-FLO System you can easily add fertilizers and supplements directly to the root zone of the plants efficiently and effortlessly without the fear of plugging. EZ-FLO MAXX Solutions offer a wide variety of products optimized for drip and subsurface environments to fertilize, protect, and maintain your landscape and irrigation system investment. Fertilize through drip irrigation Courtesy of Netafim USA 1
4 A Green Solutions Company The EZ-FLO Advantage HI-FLO Metering Systems Patented fluid flow technology Virtually unlimited injection adjustment range From ounces per hour to gallons per minute Easy to install Easy to use Durable - no moving parts Capacity 45 to 86 gallons of liquid 450 to 860 pounds of water soluble powder Custom sizes available Uses fully concentrated product - no mixing required Feed through all irrigation including drip and subsurface No electricity required - works with water flow Reduces fertilizer, labor and water costs Apply Non-Hazardous MAXX Solutions Mix multiple products for one step application Durable - 5 Year Warranty MAXX PRODUCTS Applied Though EZ-FLO Systems Promote Sustainable Landscape Practices FERTI-MAXX FERTILITY FERTI-MAXX - LANDSCAPE FERTI-MAXX - TURF FERTI-MAXX - COOL FERTI-MAXX - BALANCE FERTI-MAXX - STARTER FERTI-MAXX - ORGANIC FISH FERTI-MAXX - ORGANIC SUGAR MAXX PEST CONTROL CRITTER-MAXX Improve water quality and soil fertility Repair soil damaged by heavy chemical applications Prevent drip system plugging Reduce water requirements by 50% or more Reduce fertilizer needs by up to 90% Reduce or eliminate herbicides and pesticides FERTI-MAXX SUPPLEMENTS IRON-MAXX - IRON ROOT-MAXX - ROOT COLOR-MAXX - COLOR WATER-MAXX WATER TREAENT HYDRO-MAXX MAXX-FLUSH HYDRO-CLEANSE More products coming soon! Sustainable Landscape Solutions 1
5 HI-FLO Metering Systems HI-FLO Metering Systems The HI-FLO Metering Systems are high for large applications such as sports turf, HOA, parks, resorts, commercial properties, public properties, schools, golf and grower. Heavy duty fiberglass tank PSI maximum operating pressure Heavy duty schedule 80 PVC components PSI maximum operating pressure Chemical resistant components for injection of acids, fertilizers and chemicals High capacity HF gallons of liquid or 450 pounds of water soluble products HF gallons of liquid or 860 pounds of water soluble products Quick refill design All components for installation included except the main line connection Installs 2 to 12 main lines Installation Connectors HF045 & HF086 HFC Coupling Connection HI-FLO Coupling Connectors for pipe sizes 2 to 4 Provides additional injection rate control for very high injection rates Schedule 40 PVC with socket ends for gluing Tubing outlets for connection to HI FLO Metering Systems HFC-200 TO HFC-400 SVF Saddle Venturi Connection Kit HI-FLO Saddle Venturi Connection for pipe sizes 2 to 12 No pipe cutting - installed through 2-1 1/4 drilled holes Venturi connects to saddle with 3/4 or 1 FIPT For very high injection rates install a butterfly valve between saddles Stainless steel ball valves for isolation / shut-off Includes all connection components Custom Engineered Connections SVF Custom engineered connections are available for special installations that standard connection options cannot be used. For additional information go to our website at Resources include: CAD drawings Product cut sheets Installation instructions 3
6 A Green Solutions Company Design HI-FLO Metering System Metering Gauges Gauges come with the HI FLO Systems and are available in seven ranges. The 2-20 GPH gauge is standard. If another range is preferred, specify when ordering. Available ranges are: 1 to 10 GPH 2 to 20 GPH 4 to 40 GPH 10 to 100 GPH.2 to 2 GPM.5 to 5 GPM.2 to 2 GPH *Slow injection HI-FLO Metering System Enclosures Constructed of 12 gauge powder coated steel making both durable and light weight. HF-045ENC - Enclosure for the HF045 HF-086ENC - Enclosure for the HF086 Removable front panel provides full access to EZ-FLO systems Ship disassembled for reduced freight costs and easier handling No crane or equipment required Available in custom colors 5 Year warranty on fading of powder coating Main Line Connections HI-FLO Ball Valve Coupling Connection - schedule 40 PVC with socket connection for gluing into PVC main lines. HFC-200 = 2 Socket HFC-250 = 2 ½ Socket HFC-300 = 3 Socket HFC-400 = 4 Socket Saddle Venturi Connection Kit - for connection to PVC, Steel, Ductile Iron or Copper pipe sizes 2 to 12. Includes 2 stainless steel ball valves for shutoff at the main line connection point (not pictured). Saddle - 2 = 2 Main Line Saddle - 3 = 3 Main Line Saddle - 4 = 4 Main Line Saddle - 6 = 6 Main Line Saddle - 8 = 8 Main Line Saddle - 10 = 10 Main Line Saddle - 12 = 12 Main Line Custom engineered connections are available for special installations. Contact EZ-FLO for assistance. 4
7 Design Choosing the system To determine the system for your application, complete the following information: 1. The approximate size of the irrigated area 2. The approximate landscape mix of turf to shrubs and beds 3. The size of the irrigation main line 4. Is the irrigation system protected by a backflow preventer 5. Number of points of connection Choosing the correct tank size 1. In table 1 below refer to the 4-6 week coverage columns to determine the tank model 2. The tank capacity recommended below is based on the size of the irrigated area and a 4-6 week refill cycle. More area can be covered with a more frequent refill schedule. Model Capacity Capacity Coverage 4-6 Weeks - Square Feet Unit Size Gallons Pounds Turf and Shrubs Trees, Shrubs, Flowers W x H HF , ,000 21" x 57" HF ,000 1,720,000 24" x 66" System components Air Vent Valve Water Supply Liquid Products Metering Head Injection Return Shut Off Valve Fill Valve Water Supply Dry Products Injection Metering Gauge Water Supply Shut Off Valve Bypass Flow Adjustment Valve Injection Return Line Bypass Line Water Supply Line Injection Return Shut Off Valve Injection Return Saddle Connection Purge and Drain Valve Water Supply Shut Off Valve Water Supply Saddle Connection Flow Irrigation Main Line 5
8 A Green Solutions Company Installation & Operation Installation and operation 1. Install the system connector in the irrigation main line after an approved backflow preventer and before the irrigation zone valves. 2. Connect the flexible tubing to the main line connectors and to appropriate connection on the Metering Head. Refer to the diagram below. 3. Fill the tank with the recommended amount of products and top off with water. 4. Turn on an irrigation zone and adjust the meter to the desired injection rate. Connect the tubing to main line connection and to the Metering Head Tubing Connection Water Soluble Products Tubing Connection Liquid Products Water Supply - IN Liquid Products (Not Connected) Injection Return Fertilizer Out Water Supply - IN Liquid Products (Connected) Water Supply - IN Powder Products (Connected) Injection Return Fertilizer Out Water Supply - IN Powder Products (Not Connected) 5 5 6
9 Technical Specifications HF Series Specifications HF045 HF086 Tank Capacity (Approx.) - Liquid 45 Gal. (170 liters) 86 Gal. (325 liters) Tank Capacity - Water Soluble 450 lbs. (204 kg)* 860 lbs. (390 kg)* Dimensions (WH) Inches 21 x x 66 Dimensions (WH) cm 53 x x 167 Approx. Weight: 54 lbs. (24.5 kg) 91 lbs. (41.3 kg) Maximum Operating Pressure Minimum Operating Pressure 125 PSI 5 PSI Tank Sizing Capacities available up to 86 gallons of liquid and 860 pounds of dry water soluble products *The amount of water soluble fertilizer that can be loaded into this model is dependent upon the solubility of the fertilizer and following the suggested fill instructions for this unit. The range listed is the maximum tank capacity using a high quality, water soluble fertilizer. Lesser amounts may be used without affecting the proportioning performance of the unit. HI-FLO Models Warranty: Five (5) years except under heavy pressure conditions or excessive temperature conditions where summer temperatures exceed 125 F (52 C). Heavy pressure conditions are when static line pressure exceeds 125 PSI (8.6 bars). See other detailed warranty and installation limitations at Includes: HI-FLO metering head, fill assembly, fill drain valve, purge valve, tank stand, and two shut-off valves (Inflow and outflow shutoff) Does Not Include: Main line connector This system connects directly to the irrigation piping. EZ-FLO s patented flow process automatically adjusts to changes in water pressure and water flow. This product is designed to feed both sprinkler and drip irrigation systems for commercial, municipal, sports field, golf course and grower applications. A code compliant back flow prevention device is required for installation into potable water systems in which the installation must follow local and state plumbing codes. Unless otherwise specified, a pressure vacuum breaker is the minimum back flow prevention device required according to University of Southern California - Foundation for Cross Connection Control and Hydraulic Research. 7
10 A Green Solutions Company Technical Specifications HF Metering Head The metering head can be used for both acid and fertilizer injection. HI-FLO Metering Head - can be used for both liquid and powder products. The Water In connection can be changed between inlet ports with the provided threaded unions to change from injecting liquids to injecting powders. *Injection rate capabilities are dependent on the installation design. Faster injection rates may require the installation of a control valve between the saddle venturi connections. HF-HEAD Warranty: Five (5) years except under heavy pressure conditions or excessive temperature conditions where summer temperatures exceed 125 F (52 C). Heavy pressure conditions are when static line pressure exceeds 125 PSI (8.6 bars). EZ-FLO assumes no responsibility or warranty for tanks not manufactured by EZ-FLO. See other detailed warranty and installation limitations at 8
11 Technical Specifications HF Series Vertical Tank Enclosure EZ-FLO HI-FLO Vertical Tank Enclosure Constructed of 12 gauge powder coated steel, the EZ-FLO vertical tank enclosure is both light weight and durable Louvered side panels insure proper cooling in high heat conditions Removable front panel provides full access to EZ-FLO system Hydraulically assisted lid provides soft and easy operation when refilling system (12) base mounting points for secure installation to a concrete pad All enclosures ship disassembled for reduced freight and set up costs No crane required, can be assembled on site by one person in less than an hour HF-045ENC HF-086ENC For Use With Model: HF-045 HF-086 Dimensions (LWH) Inches 25 1/4 x 25 1/4 x 65 3/4 30 X 30 X 75 Dimensions (LWH) cm 64 x 64 x x 76 x 190 Approx. Weight: 300 lbs. (136 kg) 500 lbs. (227 kg) Warranty: Five (5) years on fading of powder coating Includes: (2) Louvered side panels, (1) solid back panel, (1) removable front panel, (2) front brackets, (1) solid lid with lock guard, (2) 20 lb hydraulic shocks, (1) bolt & washer kit, (8) anchor bolts Does Not Include: HI-FLO System or HI-FLO Installation Components, Installation tools, Concrete Anchors Installation: EZ-FLO HF Series Enclosures are designed to be installed on a concrete pad with minimum 1/4 x 2 ½ concrete anchor bolts. EZ-FLO does not warrent its enclosures installed in any other manner or when not use with EZ-FLO HF systems. 9
12 SPORTS TURF COMMERCIAL LANDSCAPE PARKS HOA PROPERTIES The World Leader FAST GROWTH FOR NEW PLANTINGS ALL TYPES OF IRRIGATION With EZ-FLO you can have a lush, green landscape using 50% less water OPTIMIZE DRIP IRRIGATION Sustainable Landscape Solutions REV1015
FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS
IRRIGATION EQUIPMENT LTD. FERTILIZER T A N K S SERIES 6000 APPLICATIONS Designed specifically for fertigation in agriculture Simple, efficient and trouble free operation. Standard models apply fertilizer
More informationGlossary Irrigation Terminology
Glossary Irrigation Terminology ANGLE VALVE A valve configured so its outlet is oriented 90 from its inlet. In irrigation, these valves are generally installed with the inlet at the bottom of the valve.
More informationChemigation. in Georgia
Chemigation in Georgia Table of Contents Chemigation Terminology...3 The Benefits of Chemigation...3 General Principles of Chemigation Safety Considerations...3 Injection Methods...4 Determining Injection
More informationC. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationDiffused Aeration Piping Equipment
1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections
More informationrecycle water reuse it save up to from showers & baths for flushing toilets 30% of water use
Residential recycle - Water reuse Recovery - save recycle water from showers & baths reuse it for flushing toilets save up to 30% of water use www.recoverwater.com How it works Greywater is lightly soiled
More informationTYPICAL INSTALLATION INSTRUCTIONS
TYPICAL INSTALLATION INSTRUCTIONS Environment One Grinder Pump Feature Identification 1. Grinder Pump Basin High density polyethylene (HDPE) 2. Accessway Cover Painted Steel 3. Electrical Quick Disconnect
More informationModel Layout/Components of a Drip Irrigation System
Dept. of Agril. Engg, BAU Lecture Note No. 7 FNRM-121 (Hydrology, Soil and Water Conservation) Instructor- Dr. M. Job First Year Semester II Dated: 15 th July &08 th Aug Drip Irrigation: It can be defined
More informationSOP 21: Evaluation of design and operation of a micro-sprinkler system
SOP 21: Evaluation of design and operation of a micro-sprinkler system Updated 7/28/14 Estimated completion time: 8 hours Materials and equipment needed: 1. Data sheet 2. Clipboard 3. Sharpie pen 4. Flags
More informationEngineering Design Center. Standard Drawings. 1st Edition -January 2016
Engineering Design Center Standard Drawings 1st Edition -January 2016 Golden State Water Company Standard Drawings 1/11/2016 Table of Contents PART A STANDARD DRAWINGS Section I Pipeline Construction P-1
More informationBOWLING GREEN KITS BG4 AND BG9
BOWLING GREEN KITS BG4 AND BG9 THE BG4 AND BG9 DESIGNS IN BRIEF The two designs enclosed are two options in watering a bowling green. We have designed both watering system that automatically water twenty-five
More informationOwners Manual Models: 200-RODI4-XXX. US Water Systems 4 Stage RO/DI System Installation and Maintenance Manual.
Visit us online at www.uswatersystems.com US Water Systems 4 Stage RO/DI System Installation and Maintenance Manual Owners Manual Models: 200-RODI4-XXX US Water 4 Stage RO/DI System REVISION 1.0, 5/12/2015
More information50 GPM Skid Mounted Water Purification System
50 GPM Skid Mounted Water Purification System Dual Filtration for Sediment and Taste/Odour Fail-Safe Operation with UV Monitor & Solenoid Valve SPECIFICATIONS WYCKOMAR 50 GPM Skid Mount Rated Flow: 189
More informationINDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series
INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series (Single, Twin, Triple or Quadruple Demand Systems) 1 P age filtration equipment can be engineered to solve complex commercial and industrial water treatment
More informationA HISTORY OF AQUATIC EXCELLENCE
A HISTORY OF AQUATIC EXCELLENCE Ever since our modest beginnings in 1934, Danner Manufacturing has developed and produced innovative products for aquarium hobbyists and professionals. We introduced the
More informationMODEL SJ10. Installation Manual. SumpJet TM - Water Powered Backup System C IMPORTANT: MODEL SERIAL
Installation Manual 5824000C SumpJet TM - Water Powered Backup System MODEL SJ10 7000 Apple Tree Avenue, Bergen, NY 14416 Phone: (800) 543-2550 liberty@libertypumps.com website: www.libertypumps.com IMPORTANT:
More informationCalcium Thiosulfate S-6Ca LIQUID FERTILIZER. Gypsum Field Study
A p p ly t h e 1 0 0 % S o lu b l e C a l c i u m a n d S u l f u r S o i l A m e n d m e n t Reduce the Harmful Effects of Sodium Calcium Thiosulfate 0-0-0-10S-6Ca LIQUID FERTILIZER CaTs vs. Gypsum Field
More informationSECTION PACKAGE BOOSTER PUMP STATIONS
SECTION 331223 PACKAGE BOOSTER PUMP STATIONS Scope: The Contractor shall install a pump station at two locations to be determined by the Owner. These pump stations shall be designed to deliver flow to
More informationMASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version
MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SCP Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description
More informationAgri-Inject.com. Fluid injection technology systems for precise control over what happens on your course. Product Guide 1. Agri-Inject.
Fluid injection technology systems for precise control over what happens on your course. Product Guide 1 Your irrigation system should do more than just water your course. Agri-Inject makes that happen.
More informationTYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:
Effluent Pumps: Effluent pumps are the pumps most often used in small on-site systems. They are designed to pump effluent, the effluent flowing out of a septic tank. This effluent is relatively clear liquid
More informationAll Prospective Bidders. SUBJECT: Addendum #2. DATE: April 8, Huntley High School Athletic Field Improvements Bid Release #2
TO: All Prospective Bidders SUBJECT: Addendum #2 DATE: April 8, 2013 PROJECT: Huntley High School Athletic Field Improvements Bid Release #2 OWNER: Consolidated School District #158 Algonquin, IL CONSTRUCTION
More informationSPECIFICATIONS FOR THE INSTALLATION OF REDUCED PRESSURE BACKFLOW PREVENTERS AND CONCRETE VAULTS FOR METERS 4 AND LARGER
SPECIFICATIONS FOR THE INSTALLATION OF REDUCED PRESSURE BACKFLOW PREVENTERS AND CONCRETE VAULTS FOR METERS 4 AND LARGER Updated January 2018 RP-2 Installation Specifications 1. In W.H.U.D s service area
More informationMINIMUM SPECIFICATIONS
MINIMUM SPECIFICATIONS A) GREENHOUSE STRUCTURE: (EDUCATOR) 30 X 96 Galvanized Steel Frame Consisting of: A. Column Post: Allied 2 x 4 Rectangle 6 Spacing B. Bows: Allied 2 x 3 Rectangle 6 Spacing C. Trusses:
More informationSTANDARDS FOR LANDSCAPE IRRIGATION SYSTEMS JANUARY 2008 EDITION
STANDARDS FOR LANDSCAPE IRRIGATION SYSTEMS JANUARY 2008 EDITION TABLE OF CONTENTS Introduction... page 1 General 1. Scope of Work... page 2 2. Quality Assurance... page 2 3. Submittals... page 3 4. Site
More informationBelow is a brief introduction and script that can be used to provide more details to the Juab County PVC Drip Irrigation slide presentation.
JUAB COUNTY PVC DRIP IRRIGATION SYSTEM Contact Person: Jeffrey E Banks USU Extension Agent Juab County 160 N Main Nephi, Utah 84648 435-623-3452 jeff.banks@usu.edu Below is a brief introduction and script
More informationYOUR SPLASH PAD RESOURCE
1 Index Permits & Inspections Material List Warnings Splash Pad Types Pre-Site Grading Plumbing Schematic Pressure Testing Concrete Preparation and Pour Housing/Nozzle Installation Above Ground Water Feature
More informationfirst flush water diverters water quality first downspout, post/wall mounted and in-ground diverters
water quality first downspout, post/wall mounted and in-ground diverters Available in kit form just add PVC pipe Simple, effective and easy to install Includes Slow Release Control Valve - empties after
More informationGrease Interceptors. Design & Operation. Material & Characteristics
Grease Interceptors Dormont offers a full line of grease interceptors for installation on cooking/prep sinks, pot, pan & scullery sinks and dishwasher applications. Dormont offers a variety of interceptor
More informationIvins City Standard Specifications for Design and Construction Part 2 Engineering and Design Standards
2.9. WATER SYSTEM DESIGN Ivins City Standard Specifications for Design and Construction All culinary water mains and appurtenances shall be designed to provide for adequate future service for all contiguous
More informationMASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version
MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SC Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description
More informationBest Value Drip Irrigation Products High Quality Yet Affordable
Best Value Drip Irrigation Products High Quality Yet Affordable Right Choice of Every Farmer Driptech offers affordable drip irrigation solutions ; innovative novel high performance drip irrigation system
More informationIRRIGATION DESIGN & MAINTENANCE FOR MAXIMUM EFFCIENCY
IRRIGATION DESIGN & MAINTENANCE FOR MAXIMUM EFFCIENCY Donald D. Franklin CID, CLIA, don.franklin@hunterindustries.com (916) 899-9437 What Are The Goals Of Irrigation Design? Provide adequate soil moisture
More informationSERVICE LINES, METERS AND APPURTENANCES
AUGUST02 SECTION 02646 SERVICE LINES, METERS AND APPURTENANCES PART 1 - GENERAL 1.1 DESCRIPTION A. This section concerns materials and installation of corporation stops, curb stops, service lines, meters,
More informationMilk Pre-Cooler Plumbing Considerations. ATCP 65, Wisconsin Administrative Code and the 2015 PMO
Milk Pre-Cooler Plumbing Considerations ATCP 65, Wisconsin Administrative Code and the 2015 PMO Protection of Potable Water Supply Protecting potable water supply (well) Raw milk and chemical cleaning
More informationSECTION COOLING TOWER
PART 1 GENERAL 1.1 SECTION INCLUDES A. Mechanical induced draft Cooling Tower B. Controls C. Ladder and handrails 1.2 REFERENCES SECTION 23 65 00 COOLING TOWER A. ANSI/AFBMA 9 - Load Rating and Fatigue
More informationInstallation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01
Installation plan Washer-extractor PW 6107 EL en - GB 10.11 M.-Nr. 09 270 450 / 01 M.-Nr. 09 270 450 / 01 2 Technical Datasheet Washer-extractor: Heating: PW 6107 Electric (EL) Legend: Solid circle
More informationEndoscope Reprocessor Specification Installation Instructions
Endoscope Reprocessor Specification Installation Instructions Endoscope Reprocessing System Introduction The following document outlines the space requirements, water supply specifications, drain specifications,
More informationDrip irrigation, also known as micro irrigation
What Is Drip Irrigation? Conserve Water And Irrigate Intelligently Drip irrigation, also known as micro irrigation or trickle irrigation, is a remarkable water technology first developed decades ago. Today,
More informationFLORIDA ARMY NATIONAL GUARD PALM COAST READINESS CENTER 3A3.1 FLAGLER COUNTY, FLORIDA AIRPORT EXECUTIVE DRIVE. scale: scale: CFMO NO.
scale: scale: 3/4" NORTH Architect BRAIN SAWYER License No. AR009953 REVISIONS STORAGE BUILDING BUILDING & WALL SECTIONS DATE D.B. C.B. JOB NO. JUNE 3, 06 AJW EWH 09005 00% BID FINAL 3A3. PALM COAST READINESS
More informationTechnology. Enabling Design. Geberit Duofix Carrier
Technology Enabling Design Geberit Duofix Carrier Geberit is Behind It All! With millions of installations throughout the world, the message is clear: the Geberit Duofix Carrier allows unique design without
More informationH 2 O Neutralizer Operation & Maintenance Manual
The Handbook on Field Chlorination & Dechlorination Using the H 2 O Neutralizer Operation & Maintenance Manual Measurement Technologies, Inc. P.O. Box 2195 Redmond, WA 98073-2195 Toll free: 877-889-8482
More informationgriswold EF&G Heavy Duty end suction
griswold EF&G Heavy Duty end suction centrifugal pumps H E A V Y D U T Y E N D S U C T I O N C E N T R I F U G A L P U M P S GRISWOLD H E A V Y D U T Y E N D FLANGED CAST IRON CASING Our class 30 grade
More informationStrawberry: Drip Irrigation and Fertigation
Strawberry: Drip Irrigation and Fertigation Erick D. Smith The University of Georgia Dept. of Horticulture, Tifton Campus January 10, 2014 SE RFVC Strawberry Educational Session Rm 205 Water Irrigation
More informationDIVISION 32 EXTERIOR IMPROVEMENTS IRRIGATION
32 80 00 PART 1 - GENERAL 1.01 DESIGN REQUIREMENTS A. Design shall be square or triangular spacing and head to head coverage. B. Electrical Design: Consultant is responsible for informing the Electrical
More information200 Series In-Slab Pool Fittings
230 Series nti-vortex Plate 2-2 231 Series Sump 2-3 234 Series Sump 2-4 236 Series Sump 2-5 253 Series Overflow 2-6 255 Series Overflow/Drain 2-7 261 Series Vacuum Fitting 2-8 263 Series Eyeball Fitting
More informationIrrigation Solutions. Backflow Preventers, Pressure Reducing Valves, and Water Control Products for Irrigation Applications
Irrigation Solutions Backflow Preventers, s, and Water Control Products for Irrigation Applications Irrigation Solutions Zurn delivers industry leading water safety and water control solutions with our
More informationSECTION 5 E-Treat Water Conditioning Systems
SECTION 5 E-Treat Water Conditioning Systems WaTEr QualITy PrOduCTS Catalog 10 Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. Watts
More informationREV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms
REV. 9/08 Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms SKYTRON MOUNTING STRUCTURES for Ceiling Mounted Equipment Foreword Skytron s objective is to provide a program and guideline to assist
More informationINDUSTRIAL GUARDRAIL SYSTEMS
INDUSTRIAL GUARDRAIL SYSTEMS STRONGEST GUARDRAIL ON THE MARKET MANUFACTURED IN THE U.S.A. BEST PRICES MOST VARIETIES HEAVY DUTY ONE-LINE OR TWO-LINE Posts: 4 Sched 80 pipe Rail: 6 Sched 40 pipe Sleeved
More informationDENR Public Water Supply Section FIGURE 1(A): ALKALINITY VS PH
FIGURE 1(A): ALKALINITY VS PH FIGURE 1(B): ALKALINITY VS TOTAL FREE CARBON DIOXIDE Source of Figures 1(a) and 1(b): Water Supply and Waste Disposal. Hardenberg, W.A., and Rodie, E.S., International Textbook
More informationMASTER. Installation and Operation Manual. Water Conditioning Corp. DECHLOR Series Flow-Through Residential Carbon Filters.
MASTER Water Conditioning Corp. Installation and Operation Manual DECHLOR Series Flow-Through Residential Carbon Filters 2010 Version Table of Contents Page No. Topic Description 1 Model # and Packaging
More informationHigh Efficiency Liquid-Solid Separators
High Efficiency Liquid-Solid Separators Continuous Filtration with Zero Maintenance ehtx Features and Benefits: Filter performance rated to remove 98% of all solids 44 micron (325 mesh), 2.6 specific gravity,
More informationVIKING BOLTED-LID BASKET-TYPE LINE STRAINERS
Page 642.1 LOW PRESSURE DROP EASY TO CLEAN LIGHT IN WEIGHT SMALL IN OVERALL DIMENSION VIKING QUALITY DUCTILE CONSTRUCTION Series Description Viking Bolted-Lid Simplex Strainers provide protection for your
More informationWATER UTILITY WORKER, 3912 WATER UTILITY SUPERVISOR, 3976
3-25-88 WATER UTILITY WORKER, 3912 WATER UTILITY SUPERVISOR, 3976 Summary of Duties : Installs, maintains, replaces, and repairs water mains, services, irrigation systems, fire hydrants, and appurtenant
More informationCalculate the Costs of Piping System Elements
Calculate the Costs of Piping System Elements by Ray Hardee, Engineered Software, Inc. Last month s column described the process of creating an energy cost balance sheet for a piping system (see Figure
More information2015 UPC Chapter 6 Water Systems Part 1 RV
PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.
More informationThe Culligan Hi-Flo 50 Series Industrial Water Filter System
The Culligan Hi-Flo 50 Series Industrial Water Filter System Durable High-Volume Water Filtration for Industrial Applications The Culligan Hi-Flo 50 Filter reduces contaminants* and solids that affect
More informationOxiPRO Q2.0 Microbial Control Technology
OxiPRO Q2.0 Microbial Control Technology Specification SPEC-613 OxiPRO Q2.0 Microbial Control Technology improves paper machine efficiency by proactively monitoring and controlling microbial-based deposits.
More informationWellhead Protection General Guidelines for New Private Domestic Wells
Wellhead Protection General Guidelines for New Private Domestic Wells Key principles for wellhead protection for private domestic wells are as follows. Proper Location of Well (Proper sanitary control
More informationIRRIGATION OF APPLES. rotator technology. Handy Pocket Guide. save water, save energy and do a better job of irrigating.
Handy Pocket Guide rotator technology save water, save energy and do a better job of irrigating. IRRIGATION OF APPLES Copyright 2008 Nelson Irrigation Corporation 1 R5 9-29 GPH 34-110 LPH R10.3-1.1 GPM
More informationspecial male. Bronze 3-Piece Full Port Ball Valve With Male Brazed Extensions
82-200 special male Bronze 3-Piece Full Port Ball Valve With Male Brazed Extensions Solder end, 600 CWP (psig), Cold Non-Shock. 150 psig Saturated Steam. Vacuum Service to 29 inches Hg. Designed for soft
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING
SECTION 221316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following soil and waste, sanitary drainage and vent piping inside the building: 1. Pipe, tube,
More informationChapter 2. Editor. Ted W. van der Gulik, P.Eng. Senior Engineer. Authors. Stephanie Tam, P.Eng. Water Management Engineer
B.C. SPRINKLER IRRIGATION MANUAL Chapter 2 Editor Ted W. van der Gulik, P.Eng. Senior Engineer Authors Stephanie Tam, P.Eng. Water Management Engineer Andrew Petersen, P.Ag. Regional Resource Specialist
More informationEL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD Fire Water Supply without a Purveyor Residential & Commercial STANDARD #D-003 EFFECTIVE 01-04-2016 1. PURPOSE 1.1. The California Fire Code (CFC) requires
More informationDesign study of ship LNG storage and engine feeding system. Gerasimos Theotokatos NAOME, University of Strathclyde
Design study of ship LNG storage and engine feeding system Gerasimos Theotokatos NAOME, University of Strathclyde Introduction This study focuses on the design of the LNG storage and feeding system of
More informationInstallation Instructions EQ-400 Whole House Water Filter
Installation Instructions EQ-400 Whole House Water Filter Welcome to the Aquasana experience. You are about to enjoy clean, clear water and the peace of mind that comes from knowing award winning filter
More information1-800-ICE-BRIX
1-800-ICE-BRIX www.polar-tech.com TEMPERATURE SAFE SHIPPING & PROTECTIVE PACKAGING PRODUCTS DISTRIBUTION AND MANUFACTURING LOCATIONS: CHICAGO/MIDWEST NYC/PHILA Dry ice snow makers are ergonomically engineered
More informationPre-Sloped Drain System
SportsEdge PolyDrain Pre-Sloped Drain System www.sportsedge.com Quality. Safety. Versatility. Aesthetics. 2 PolyDrain FORMULA www.sportsedge.com ABT, Inc. manufactures PolyDrain trench drains; the standard
More informationRural Servicing Guidelines
Rural Servicing Guidelines for Low-Pressure Sanitary Sewer System and Trickle Feed Water Distribution System FOREWORD This manual is intended to provide information to Developers, Engineering and Geotechnical
More informationAll service lines shall conform to the following requirements:
505 WATER SERVICE INSTALLATION 505.1 DEFINITION A service line is comprised of the piping and related appurtenances including the connection installed from the Des Moines Water Works water main to the
More informationHydroCycle Commercial NFT Systems
HydroCycle Commercial NFT Systems Designed to grow healthy plants without soil using mineral-nutrient solutions. 2017 Growers Supply All Rights Reserved. Reproduction is prohibited without permission.
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 32 8400 PLANTING IRRIGATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationThe Filterautomat. Our Filter Systems Protect. The New Definition of Purity for Your Medium. flow rate 5 m 3 /h to 4,000 m 3 /h. filter fineness 5 µm
GB Filterautomat The New Definition of Purity for Your Medium Our Filter Systems Protect The Filterautomat Cooling Water River Water Plate Heat Exchangers Spray Nozzles Sea Water Sinter and Scale Separation
More informationB BASF MasterFlow MasterFlow MasterFlow MasterFlow C CGM Grout...8
B BASF MasterFlow 100...2 MasterFlow 648...5 MasterFlow 885...4 MasterFlow 928...3 C CGM...8 F FIVE STAR GROUT...7 G GROUT Five Star Non Shrink...7 General Purpose...6 Masterflow 100...2 Masterflow 648...5
More informationWATER SUPPLY AND DISTRIBUTION
CHAPTER 29 WATER SUPPLY AND DISTRIBUTION Chapter 29 is not adopted in the City of Seattle. See the Uniform Plumbing Code for plumbing regulations. SECTION P2901 GENERAL P2901.1 Potable water required.
More informationGerber M Series Site Requirements
Gerber M Series Site Requirements Preparing for the arrival of your new machine. P rior to the arrival of your Gerber M Series Cutting System there are certain things you can prepare to facilitate a quick
More informationClay County Utility Authority Approved Materials " "
Clay County Utility Authority " "" Clay County Utility Authority "". "". " Clay County Utility Authority DESCRIPTION: Extruded sheets or panels with integral male/female sliding lock connection ends.
More informationCOMBINATION AIR VALVE
MINING DIVISION COMBINATION AIR VALVE FOR HIGH FLOW D-6NS SERIES DESCRIPTION The D-6NS Series Combination Air Valve has the features of both an air release valve and an air & vacuum valve. The air release
More informationHOLE SAMPLING & MONITORING. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD
HOLE SAMPLING & MONITORING MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD www..com HOLE SAMPLING & MONITORING TABLE OF CONTENTS HOLE SAMPLING & MONITORING OVERVIEW...2 SPLIT
More informationINSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS
INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS Rev. 1.5 1.10.13 Toll free (800) 288-6000 or www.hubbell-wiring.com P a g e 0 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING- When using
More informationGRAY WATER RECYCLING SYSTEMS
GRAY WATER RECYCLING SYSTEMS Note: Section P2601.2 of the International Residential Code requires all plumbing fixtures that receive water or waste to discharge to the sanitary drainage system of the structure.
More informationUNPARALLELED PERFORMANCE
UNPARALLELED PERFORMANCE PRODUCT CATALOGUE Section 02 SLOT DRAIN SYSTEM DESIGN PRODUCT CATALOGUE 23 02.1 System Design SLOT DRAIN PROFILES STAINLESS STEEL SLOT DRAIN FIBERGLASS SLOT DRAIN The Slot Drain
More information1. Magnetic devices work best on water the have colloidal size particles present prior to being exposed to a magnetic field.
1. PURPOSE OF TEST The use of catalytic and or magnetic water treatment for scale reduction/elimination has been going on for many years. Contact with professional water treatment dealers, engineers in
More informationCross-Connection Control Program. Manual of Procedures
Cross-Connection Control Program Manual of Procedures Revised October, 2006 Table of Contents Introduction.. 2 Definitions. 3 Responsibilities.6 General Requirements... 7 I. Containment Cross-Connection
More informationFiberglass Cooling Towers
Fiberglass Cooling Towers Available in sizes from 100 to 240 tons. FC Series 700 Fiberglass Cooling Tower Available in sizes from 170 to 240 tons. No other fiberglass cooling tower comes with as many high-quality
More informationSTORM UTILITY WATER DRAINS
1. Product Name ACO Drainª K100S General-Purpose Trench Drain ACO Drainª S100K Heavy Duty Trench Drain ACO Drainª S300K Heavy Duty Trench Drain ACO Drainª FG100 High Capacity Trench Drain ACO Drainª FG200
More informationWastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 7.4 PERMEATION GROUTING 7.4.1 Definitions 7.4.1.1 Geotechnical Data Report (GDR)
More informationPart Numbers. Kinetico Drinking Water Systems. Revised: 07/2016 Drinking Water Systems Parts Pages Section 7 Page 1
Part Numbers Kinetico Drinking Water Systems Revised: 07/2016 Drinking Water Systems Parts Pages Section 7 Page 1 Model 7000/7500 Components 4 7A 1 8 7B 2 5A 3 5B 6A 6B Dwg. No. Description Part No. 1
More informationGRAY WATER SYSTEMS (Reference California Plumbing Code Chapter 16 and 16A) Revised: 6/11/14
Planning and Building Department 525 San Anselmo Avenue Building Division San Anselmo, CA 94960 Phone: (415) 258-4616 Fax: (415) 454-4683 GRAY WATER SYSTEMS (Reference California Plumbing Code Chapter
More informationEZ LOADER. Bishamon. EZ Loaders are true ergonomic tools. in every sense of the word. They are. designed to eliminate worker bending
EZ LOADER A U T O M A T I C P A L L E T P O S I T I O N E R EZ Loaders are true ergonomic tools in every sense of the word. They are designed to eliminate worker bending by automatically raising and lowering
More informationFAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.
FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Introduction Fairbanks Nijhuis manufactures a complete line of submersible pumps for municipal and industrial
More informationRULES AND REGULATIONS FOR WATER AND WASTEWATER SERVICE APPENDIX B WATER AND WASTEWATER SERVICE CONSTRUCTION SPECIFICATIONS
RULES AND REGULATIONS FOR WATER AND WASTEWATER SERVICE APPENDIX B WATER AND WASTEWATER SERVICE CONSTRUCTION SPECIFICATIONS Last Approved Revision: 3-23-2017 Page i TABLE OF CONTENTS SECTION I GENERAL...
More informationCaptor Containment DOUBLE WALL TANK SYSTEMS.
Captor Containment DOUBLE WALL TANK SYSTEMS Captor Containment System Protects Bulk Storage Profits Without Jeopardizing Safety or the Environment Flanged Outlets and other fitting designs can be securely
More informationSUGGESTED SPECIFICATIONS Pump Frames through 64132
TYPE HBB - HORIZONTAL SOLIDS-HANDLING WASTEWATER PUMPS Pump Frames 44081 through 64132 GENERAL Furnish and install Horizontal Flexible Coupled Dry Pit Pumping Units complete with all accessories and appurtenances
More informationPioneer Forced Draft Cooling Tower Specifications
Delta Cooling Towers, Inc. 41 Pine Street P.O. Box 315 Rockaway, New Jersey 07866-0315 Telephone 973.586.2201 Fax 973.586.2243 www.deltacooling.com sales@deltacooling.com Pioneer Forced Draft Cooling Tower
More informationOn Site Detention System.
On Site Detention System. Setting new standards. NOTE: This OSD (On site detention system) brief should be read in conjunction with the Landscape Tanks brochure, which outlines all the features and benefits
More informationW ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372.
W ST IND TRY FIR US ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS Certified to NSF/ANSI 372 www.fairbanksnijhuis.com FAIRBANKS NIJHUIS 1600 SERIES Single Stage End Suction Pumps
More informationCooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720)
CTD Proposal : - Project: Project Location: Cooling Tower Design Conditions and Dimensions: Water Flow Rate (gpm) 0 CTD Model # Hot Water Temp (F) 0 Cell Dimensions (ft) L x W x H Cold Water Temp (F) 0
More informationDOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND
DOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND JULY 2002 Copyright 2001 H.I.L. Technology, Inc. All rights reserved. This report was
More information