Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures

Similar documents
Inlets & Catch Basins

Environmental Products. Designed to Protect and Improve Our Environment. Delivering Reliability

16. Design of Pipeline Structures.


UNIVERSITY OF MISSOURI Electrical Manholes and Handholes 2016 Q1

GENERAL UTILITIES REQUIREMENTS

Special Specification 6186 Intelligent Transportation System (ITS) Ground Box

CONSULTANT PROCEDURES & DESIGN GUIDELINES Electrical Manholes and Handholes UNIVERSITY OF MISSOURI

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

UNM IT/Telecommunications Guide Specification Communications Underground Ducts, Raceways and Structures /27/06

ASTM C857 A -16 AASHTO H -20 (for vaults beneath roadways) ASTM C857 A-8 (for vaults beneath incidental light truck traffic)

Effective Date: Revision #: 1. Section I: Castings and Aluminum Covers. Valve Boxes. Service Clean-out Box and Lid

General Symbols, Ducts and Cables

ZG Scope. 2 Applicable Documents. 3 General. 4 Stock Item Numbers. Padvault Single-Phase Residential, 2.1 PacifiCorp Material Specifications

General Symbols, Ducts and Cables

Section 7: Specifications

General Symbols, Ducts and Cables

DUKE UNIVERSITY CONSTRUCTION & DESIGN STANDARDS

Miscellaneous and Cast Iron Listings

PERMANENT PAVEMENT REPAIR NO SCALE

Electric Service Standards

Precast Concrete Engineering

SEISMIC RESTRAINT SYSTEM

Current Standard Plates including Transmittal Letters are available on the web at:

POST FRAME BUILDING STANDARDS

Draft. Not yet Approved

SECTION STORM DRAINAGE

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION

CHAPTER 12 HANDHOLES, PULLING VAULTS, AND JUNCTION BOXES

Storm Drainage

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

SECTION SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED PART 1 GENERAL 1.1 DESCRIPTION:

SECTION STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

Defence ] Defence 9/14 A DIVISION OF STRONGFORM GROUP

WWR For Structural Applications A Discussion of Current Product Knowledge and Practices

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details

Michigan State University Construction Standards ELECTRICAL UNDERGROUND DUCTS AND MANHOLES PAGE

SPECIAL SPECIFICATION 6664 Level (3) Communications System

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SPECIAL SPECIFICATION 6658 Time Warner Communications System

50.20 Drainage Structure Design

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

University of Delaware

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

SECTION GROUNDING AND BONDING

CONCRETE TECHNOLOGY CORPORATION

MANUFACTURER S SPECIFICATIONS Section LIME CONCRETE. A. This section describes the requirements for floors and slabs on grade.

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION

HANDHOLES, PULLING VAULTS AND JUNCTION BOXES

SECTION ELECTRICAL SITE UTILITIES

SECTION UTILITY MANHOLES AND STRUCTURES

Pre-Sloped Drain System

ITEM 555 CHAIN LINK FENCING

MATERIAL SPECIFICATION FOR STEEL POLES, BASE MOUNTED

A. Section Includes: Electrical site utilities and coordination of requirements with the utility company and service specifications.

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

Transformer Pads and BURD Cages

SUPPORT AND ANCHORS SECTION 15090

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

Utility Cabinet System (UCS)

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

Summary of Modifications/Changes in this Update

Facility Sanitary Sewers

STANDARDIZED STRUCTURES

END ELEVATION FRONT ELEVATION. LEG (inside view) TOP (1:20) FOOT - FIXING DETAIL (1:5) (1:20) CONSTRUCTION STANDARD

SECTION PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY

STREET LIGHTING GENERAL INFORMATION

7. New railings for existing buildings shall be designed to match any existing railings unless there is a compelling reason for change.

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities

SECTION ELECTRICAL UTILITY SERVICES

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

Energy Delivery Service Guide Appendices

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

ANTI RAM SECURITY CHAIN LINK FENCE - 4, MPH SECTION

Testing. Test drainage products according to the applicable AASHTO or ASTM specification, except as otherwise noted.

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION CONCRETE MANHOLES PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes:

SECTION MISCELLANEOUS METALS

Engineering Specifications February, 2004 Schedule H to Bylaw 7452, Subdivision Bylaw Page 105 ELECTRICAL DETAILS. base. base. base.

TITLE: CAMP JOHNSON OVERPASS / HWY 17 BYPASS SECURITY FENCE UPGRADES

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES

PART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

1. Approved Manufacturers: Carlon Electrical Products, Cantex, or approved equal.

SUPPLEMENTAL DRAWINGS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

PRECAST RECTANGULAR CHAMBERS

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS

Underground Exhaust System

AREMA C&S Manual 2018 (Includes 2018 Revisions) Volume 4 Index SECTION 14 - ELECTRICAL DEVICES, FOUNDATIONS, HARDWARE

Manholes (Underground Ducts & Raceways for Electric Systems)

SECTION GROUND WATER STORAGE TANKS

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

Transcription:

A Delivering Reliability Electrical Vaults Power & Energy-Underground Structures

A The Benefits of Precast Vaults Electrical vaults house power cables and transformers, and are a preferred alternative to running electrical power cables above the ground and across utility poles. Oldcastle Precast s vaults come in multiple dimensions and are perfect for electrical, utilities, fiber-optic, and communications applications. Our products include access doors, manhole covers, blockouts, knockouts and much more. COVER & FRAME FINISH: Hot Dip Galvanized after Fabrication. FRAME: Can be Fabricated for Cast-In Applications. LOADING: Designed for H20 loading for Non Roadway Applications. DOORS: Offered in Single, Double, or Triple Configurations, open 180 Degrees. Environmentally Responsible All of our products are produced in a controlled environment helping us maintain the high standards implemented by Oldcastle Precast. Many of our products are specifically designed to protect and improve the environment. We re always looking for new ways to minimize waste, increase recycling, improve energy management and use ecofriendly materials. Material and Design Loads The structural notes below are for standard models. We can design vaults to meet other specifications. 1. Concrete 5000psi (35 Mpa) @ 28 days. 2. Rebar ASTM A 615 grade 60 rebar. 3. Mesh Welded Wire Fabric ASTM A185 grade 65 4. Design Building Code Requirements for Reinforced Concrete (ACI 318-99) including all referenced standards and specifications. AAS- HTO Standard Specifications for Highway Bridges - 16th edition. 5. Loads Dead Load: Concrete - 150 PCF Earth Cover - 120 PCF Lateral Earth Pressure on walls: Equivalent Fluid pressure above water table + 39.6 PSF per foot of depth. Equivalent Fluid pressure below water table + 81.4 PSF per foot of depth. Surcharge on walls + 2 feet of earth cover EMBEDDED LIFTERS MATERIAL: Galvanized Utility Anchors LOADING: Offered in 2, 4, 8, & 20 Ton 1 Ton Universal Lifters also available. GRADE RINGS / RISERS FINISH: Concrete Designed to bring Covers up to Grade. Can be Rectangular or Round. EMBEDDED PULLING IRONS Allows Cable Pulling Equipment to be anchored. MATERIAL: Carbon Steel-Galvanizing Standard. Stainless Steel available on request. DRAINAGE SUMP MATERIAL: Propylene 2 Knock-Out hole in Base for Drain Pipe by others. Outer Lip Positively Locks Base into Concrete. Live Load: AASHTO HS20-44 32,000 lbs. rear axle loading We can provide drawings and calculations stamped by a Professional Engineer. RACKING Bolted to Unistrut or Brackets to hold and secure cables or wiring. FINISH: Galvanized Standard. Easy Vertical or Horizontal adjustability. Cable Support arms available from 4 to 18. Please call 888.965.3227 to speak with a solution specialist.

Electrical Vaults COVER OPTIONS Can be Fabricated in a variety of Sizes. HANDHOLES Used in smaller Communications Vault Applications. Can be Fabricated in a variety of Sizes. MANHOLE COVER & FRAME MATERIAL: Cast or Ductile Iron. DESIGNS: Custom Lettering & Design available. LOADING: Built to an H20 rating up to 150 KIP. SIZES: 24, 30, 32, 36 Round UNISTRUT OR INSERTS Embedded into interior walls for bolting on racking other equipment. Different Lengths and Sizes available. Stainless Steel options are available. TERM-A-DUCTS MATERIAL: PVC Different Lengths and Sizes available. Provides Point of Entry/Termination for various cables and or air vents. KNOCK-OUTS Round or Rectangular Knock-Outs offered in multiple locations to provide access for cable, conduit, or pipes as required. Easily broken with a hammer to create desired opening shape and size. oldcastleprecast.com Underground Structures

A One Piece Vault One piece vault configurations typically consist of a Base Section and a Lid Section and are commonly used in applications requiring non-confined access. NOTE: One Piece Vault configurations may also consist of a Slab Section and a Top Section. Three Piece Vault Three piece vault configurations typically co Section, and a Lid Section and are common non-confined access where minimum com loading and unloading, transportation, and i LID SECTION ACCESS OPENING-Can be any size and location. INVERTED RING & COVER as well as STEEL or ALUMINUM HATCHES can also be cast in. LID SECTION ACCESS OPENING-Can be any size and location. INVERTED RING & COVER as well as STEEL or ALUMINUM HATCHES can also be cast in. BASE SECTION SPECIAL ACCESS BLOCKOUTS, KNOCKOUTS, PULLING EYES, TERMINATORS, RACKS, ETC. can be placed as specified. DESIGNED ACCORDING TO ASTM C857-87 AND ASTM C858-83s. RISER SECTION SPECIAL ACCESS BLOCKOUTS, KNOCKOUTS, PULLING EYES, TERMINATORS, RACKS, ETC. can be placed as specified. DESIGNED FOR AASHTO HS-20 LOADING DESIGNED ACCORDING TO ASTM C857-87 AND ASTM C858-83s. SLAB SECTION DESIGNED ACCORDING TO ASTM C857-87 AND ASTM C858-83s. Please call 888.965.3227 to speak with a solution specialist.

Standard Vaults nsist of a Slab Section, a Riser ly used in applications requiring ponent weight is desired for nstallation. Multi-Piece Vault Multi-piece vault configurations typically consist of a Base Section, a Riser Section, and a Top Section and are commonly used in applications where Manhole access is sufficient and access to equipment by removal of the entire Top Section is NOT required. NOTE: Multi Piece Vault configurations may also consist of various combinations of either a Slab Section or Base Section, Multiple Riser Sections, and either a Top Section or a Lid Section. TOP SECTION ACCESS OPENING-Can be any size and location. INVERTED RING & COVER as well as STEEL or ALUMINUM HATCHES can also be cast in. CLAMSHELL Fabrication Method Reduces Weight by Allowing for Thinner Walls While Maintaining Structural Integrity RISER SECTION (Optional for greater depths) TONGUE & GROOVE OR SHIPLAP JOINT. BASE SECTION SPECIAL ACCESS BLOCKOUTS, KNOCKOUTS, PULLING EYES, TERMINATORS, RACKS, ETC. can be placed as specified. DESIGNED ACCORDING TO ASTM C857-87 AND ASTM C858-83s. *Electrical vaults are available in a variety of standard and custom sizes to suit virtually any application. oldcastleprecast.com Underground Structures

A Cable Tray Vaults Cable Tray vaults are typically used to manage the installation and connection of wires and cables used in electrical applications. NOTE: Stack heights not to exceed (2) Pit Section. Designed for installation at grade with cabinet loading. LID SECTION Cable Tray Weight= 530 lbs Installed Isometric View (Reference Only) BOTTOM SECTION Cable Tray Base Weight= 2,186 lbs Please call 888.965.3227 to speak with a solution specialist.

Standard Vaults Octagon Vaults Octagon vaults are typically used in Communications, Power, and Government site applications. NOTES: Inverted Cast Iron Ring & Cover as well as Steel or Aluminum Hatches can be cast in. Access opening can be any Size & Location. TOP SECTION OCT-T Varies BOTTOM SECTION OCT-B Varies Varies *Octagon Vaults are available in a variety of standard or custom sizes to suit virtually any application. oldcastleprecast.com Underground Structures

oldcastleprecast.com Delivering Reliability Oldcastle Precast is the leading manufacturer of precast concrete, polymer concrete and plastic products in the United States. With a nationwide network of facilities our products are always close at hand. Our employees are committed to upholding core values of reliability, quality and service in revolutionary ways. Our attention to detail exceeds the expectations of customers from some of the largest companies in the U.S., across a spectrum of industries. 888.965.3227 EV_12_2012 A 2012 Oldcastle Precast, Inc.