SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD

Similar documents
A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms.

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

D. Encase exterior cleanouts in concrete with access cover installed flush with grade.

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:

Daytona Beach Pier Building Renovation Jun 2010

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping inside the building.

A. This Section includes sanitary waste and vent piping inside the building and to locations indicated.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping specialties:

SANITARY WASTE AND VENT PIPING

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

A. This Section includes the following sanitary drainage piping specialties:

SECTION DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

A. Piping materials shall bear label, stamp, or other markings of specified testing agency.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

CONTINUED ON FOLLOWING PAGE

SECTION (15150) - SANITARY WASTE AND VENT PIPING

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Ice Rink Renovation & New Clubhouse

SECTION PLUMBING EQUIPMENT AND SPECIALTIES

SECTION FACILITY STORM DRAINAGE PIPING

SECTION FACILITY SANITARY SEWERS

SECTION FACILITY STORM DRAINAGE PIPING

SECTION STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

TENOCHCA HALL - PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION

SECTION PLUMBING PIPING SYSTEM

for plumbing regulations.

PIPING SPECIALTIES (PLUMBING) A. American Society for Testing and Materials (ASTM):

SECTION PLUMBING SPECIALTIES

SECTION PLUMBING SPECIALTIES

University of Delaware

SECTION FACILITY STORM DRAINAGE

University of Delaware

SECTION PLUMBING PIPING

SECTION PLUMBING FIXTURES

SANITARY DRAINAGE CHAPTER 30

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

SECTION PLUMBING PIPING SYSTEMS

PLUMBING. 1. New kitchen sinks and vanity sinks in residential units; new accessible showers and tubs in residential units and public showers.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

FLOOR AND AREA DRAINS

CHAPTER 7 SANITARY DRAINAGE SYSTEMS

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

Facility Sanitary Sewers

B. This Contractor's work shall include the following specification sections: SECTION MECHANICAL AND ELECTRICAL GENERAL CONDITIONS

STORM DRAINAGE CHAPTER 11

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

STORM DRAINAGE CHAPTER 11

SECTION FACILITY SANITARY AND VENT PIPING

.2 Section Waste Management and Disposal

Construction Specification

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated.

A. General provisions and other plumbing systems are specified in other Sections of Division 22.

Flashing and Sheet Metal Laboratory Equipment Plumbing Fixtures, Trim and Supports.

SECTION FACILITY STORM DRAINAGE

October 4, 2013 Construction Set OR RENOVATIONS BID PACKAGE 2 SECTION PLUMBING

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES

SECTION PLUMBING PIPING

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X

SECTION FACILITY SANITARY AND VENT PIPING

SECTION PLUMBING PIPING SYSTEMS. A. Types of plumbing piping systems specified in this section include the following:

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

STANDARD SPECIFICATIONS

AWI MANUFACTURING. Quality Products Since USDA Certified. Stainless Steel Floor Drains

Read Only Document Not For Distribution

PLUMBING SYSTEMS SECTION Complete sanitary waste and vent systems. 2. Complete domestic hot and cold water systems.

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

SUPPORT AND ANCHORS SECTION 15090

SECTION PIPING (PLUMBING) Flashing and Sheet Metal Laboratory Equipment Plumbing Fixtures, Trim and Supports.

Gas Station & C Store SECTION CWM Job No

Specification Drainage Products. Cleanout Selec on

A. Submit data on all materials, fittings, accessories and equipment.

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS

PROJECT MANUAL. Owensboro Parking Structure 414 West 2nd Street Owensboro, KY Volume II

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa).

Light-Metal Roof Edge, Raised

B. Drainage Piping: Building sewer piping outside building that conveys storm drainage from building.

1 ½

Section 4 Service Lines

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

Copyright 2017, ProVent Systems Inc., All Rights Reserved

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

A. Systems and equipment specified in this section include the following:

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION PLUMBING SYSTEMS

Errata for the 2003 Uniform Plumbing Code Study Guide (5th Printing)

SECTION FACILITY SANITARY SEWERS

TABLE OF CONTENTS

East Central College

Transcription:

PART 1: GENERAL 1.01 The design guidelines contained herein include the requirements for drainage and vent systems utilized at The University of Texas at Austin. It is the intention of this document to provide a standard for drainage and vent systems at The University that represent the highest level of quality and consistency possible; it is not intended to be a guide specification. PART 2: PRODUCTS 2.01 Manufacturers A. Standard manufacturers for Drainage Piping Specialties, including expansion joints, drains, trap primers, and vandal-proof vent caps: 1. Josam Mfg. Co. 2. Smith (Jay R) Mfg. Co. 3. Tyler Pipe; Subs. of Tyler Corp. 4. Zurn Industries Inc; Hydromechanics Div. B. Freeze-proof vent caps: 1. F.J. Moore Mfg. Co. C. Non-Metallic Trench Drains: 1. ACO Drain Inc. 2. Quazite Corp. 2.02 Above Ground Drainage And Vent Pipe And Fittings A. Cast-Iron Soil Pipe: ASTM A74, Service weight, hub-and-spigot soil pipe and fittings with 125# Clamp all or equivalent clamps. B. Polypropylene Pipe and Fuseal Fittings (or Engineer-approved equal): use for acid waste and vent piping in laboratories 2.03 Underground Building Drain Pipe And Fittings A. Cast-Iron Soil Pipe: ASTM A74, Service weight, hub-and-spigot soil pipe and fittings. Pipe and fittings shall have a heavy coating of coal tar varnish or asphaltum on both inside and outside surfaces. B. Neoprene Compression Gaskets: ASTM C564. Design & Construction Standards, Revised May 6, 2002 15420-1

C. Solvent: ASTM D2235. D. PVC Sewer Pipe and Fittings: Conform to ASTM D2729 for pipe and fittings. E. Solvent: ASTM D2564. 2.04 Drainage Piping Specialties A. Expansion Joints: Cast-iron body with adjustable bronze sleeve, bronze bolts with wing nuts. B. Cleanout Plugs: Cast-bronze or brass, threads complying with ANSI B2.1, countersunk head. C. Floor Cleanouts: Cast-iron body and frame, with cleanout plug and adjustable round top. D. Wall Cleanouts: Cast-iron body adaptable to pipe with cast-bronze or brass cleanout plug; stainless steel cover including screws. 2.05 Floor Drains A. Floor drains shall be provided with deep seal P traps at all floor drains. B. Floor Drain (Basement and air handler rooms) 12" x 12" floor sink with halfgrate strainer, caulked outlet, dura-coated. Similar to Zurn Z-567. There shall be adequate floor drains to provide drain for all equipment requiring same; one per piece of equipment, to eliminate excessive drain piping across floors. C. Floor Drain (for boiler rooms): Cast-iron body and tractor grate, flashing flange and collar. D. Galvanized body, ductile iron grate, solid bucket; hinged bar gratefloor Drain (Corridors and Hallways) Cast-iron body and flashing collar with closure plug, nickel bronze adjustable strainer head with secured square hole grate. E. Floor Drain (mechanical rooms and other remote areas) shall be provided with a central piped primer system which automatically primes traps building wide using a single timed valve for one minute every 24 hours (or adjustable.) 2.06 Depressed Area Drains. A. Floor Drain (depressed area drains): Cast-iron body for horizontal mounting secured grate. B. Floor Drain (medium traffic and drainage): Cast-iron body and flashing collar with adjustable top, and tractor grate C. Floor Drain (heavy traffic, light drainage): Cast-iron body and flashing collar with cast-iron tractor grate Design & Construction Standards, Revised May 6, 2002 15420-2

D. Floor Drain (shower and toilet rooms): Cast-iron body and flashing collar with the following features: closure plug, nickel bronze adjustable strainer head with secured square hole grate. 2.07 Trench Drains A. Cast-iron shallow hub body and grate with end plates and gaskets, assembled in standard lengths for total length and width as indicated 2.08 Roof Drains A. Roof drain (Type designations and sizes): As indicated on Drawings. B. Roof Drain (General Purpose) Cast-iron body with combined flashing collar and gravel stop, cast-iron dome. C. Roof Drain (controlled flow) Cast-iron body, combined flashing collar and gravel stop, cast-iron dome with adjustable flow rate control assembly D. Roof Drain (steel roof decks) Cast-iron body, combined flashing collar and gravel stop, cast-iron dome E. Roof Drain (parapet roofs) Cast-iron body, flashing device, loose set grate PART 3: EXECUTION 3.01 Dye Testing Of Sanitary Drains A. Contractor shall dye-test all floor, hub, sink and equipment drains to verify that they are not connected to the storm sewer system. Prior to testing, contractor shall notify UT Utilities to notify private and public agencies of potential color in the creek. B. On a day when water in the downhill creek is clear, contractor shall introduce 1 fluid ounce of 50% uranine dye into each such "sanitary" drain, followed immediately by a gallon or more of water. Contractor shall station a non-colorblind employee at the creek to watch for signs of dye, from the time the dye is first introduced until an hour after the last dye addition. This time period may be extended by the Inspector, depending upon local conditions. C. Contractor shall certify in writing to the University Project Manager that there was no evidence of dye entering the creek. 3.02 Examination A. Verify existing grades, inverts, utilities, obstacles, and topographical conditions prior to installations. 3.03 Pipe Applications - Above Ground, Within Building A. Install hubless, service weight, cast-iron soil pipe and fittings for drainage and vent pipe. Design & Construction Standards, Revised May 6, 2002 15420-3

3.04 Pipe Applications - Below Ground, Within Building A. Install hub-and-spigot, extra-heavy weight, cast-iron, soil pipe and fittings with gasketed joints for 15 inch and smaller drainage pipe. 3.05 Pipe And Tube Joint Construction: A. Copper Tubing: Solder joints in accordance with the procedures specified in ASW "Soldering Manual". B. Cast-Iron Soil Pipe: Make all joints in accordance with the CISPI Cast Iron Soil Pipe and Fittings Handbook, Chapter IV. C. PVC DWV Pipe: Joining and installation of PVC drainage pipe and fittings shall conform to ASTM D2665. 3.06 Installation A. General Locations and Arrangements: Drawings (plans, schematics, and diagrams) indicate the general location and arrangement of the piping systems. Location and arrangement of piping layout take into account many design considerations. So far as practical, install piping as indicated. B. Use fittings for all changes in direction and all branch connections. C. Install exposed piping at right angles or parallel to building walls. Diagonal runs are not permitted, unless expressly indicated. D. Install piping free of sags or bends and with ample space between piping to permit proper insulation applications. E. Conceal all pipe installations in walls, pipe chases, utility spaces, above ceilings, below grade or floors, unless indicated to be exposed to view. F. Install piping tight to slabs, beams, joists, columns, walls, and other permanent elements of the building. Allow sufficient space above removable ceiling panels to remove panel. G. Exterior Wall Penetrations: Seal pipe penetrations through exterior walls using sleeves and mechanical sleeve seals. Pipe sleeves smaller than 6 inch shall be steel; pipe sleeves 6 inch and larger shall be sheet metal. H. Fire Barrier Penetrations: Where pipes pass through fire rated walls, partitions, ceilings, and floors, maintain the fire rated integrity. Refer to Division 7 for special sealers and materials. Design & Construction Standards, Revised May 6, 2002 15420-4

I. Make changes in direction for drainage and vent piping using appropriate 45 degree wyes, half-wyes, or long sweep quarter, sixth, eighth, or sixteenth bends. Sanitary tees or short quarter bends may be used on vertical stacks of drainage lines where the change in direction of flow is from horizontal to vertical, except use long-turn tees where two fixtures are installed back to back and have a common drain. Straight tees, elbows, and crosses may be used on vent lines. No change in direction of flow greater than 90 degrees shall be made. Where different sizes of drainage pipes and fittings are connected, use proper size, standard increasers and reducers. Reduction of the size of drainage piping in the direction of flow is prohibited. J. Install underground building drains to conform with the uniform plumbing code, and in accordance with the Cast Iron Soil Pipe Institute Engineering Manual. Lay underground building drains beginning at low point of systems, true to grades and alignment indicated with unbroken continuity of invert. Place bell ends of piping facing upstream. Install required gaskets in accordance with manufacturer's recommendations for use of lubricants, cements, and other special installation requirements. Maintain swab or drag in line and pull past each joint as it is completed. K. Install building drain pitched down at minimum slope of 1/4 inch per foot (2 percent) for piping 3 inch and smaller, and 1/8 inch per foot (1 percent) for piping 4 inch and larger. L. Extend building drain to connect to sewer piping, of size and in location indicated in construction standards. Sewer piping is specified in a separate section of Division 2. M. Install sleeve and mechanical sleeve seal through foundation wall for watertight installation. N. Install 1-inch thick extruded polystyrene over underground building drain piping that s not under building. Width of insulation shall extend a minimum of 12 inches beyond each side of pipe. Install directly over, and center on pipe centerline. 3.07 Hangers And Supports A. General: Hanger, supports and anchor devices are specified in Division 15 Section "Basic Mechanical Materials and Methods". Conform to the table below for maximum spacing of supports: B. Install the following pipe attachments: 1. Adjustable steel clevis hangers for individual horizontal runs less than 20 feet in length. C. Install hangers at the following intervals: PIPE MATERIAL MAX HORIZ MAX VERT Design & Construction Standards, Revised May 6, 2002 15420-5

SPACING IN FEET SPACING IN FEET ABS Pipe 4 4 Cast-Iron Pipe 5 15 Copper Tubing 1-1/4" and smaller 6 10 Copper Tubing 1-1/2" and larger 10 10 PVC Pipe 4 4 3.08 Installation Of Piping Specialties A. Do not install backwater valves in sanitary building drain piping. B. Install expansion joints on vertical risers as indicated, and as required by the plumbing code. C. Above Ground Cleanouts: Install in above ground piping and building drain piping as indicated, and: 1. as required by plumbing code; 2. at each change in direction of piping greater than 45 degrees; 3. at minimum intervals of 50' for piping 4" and smaller and 100' for larger piping. 4. at the base of each vertical soil or waste stack. 3.9 Installation Of Floor Drains A. Set drain elevation depressed below finished slab elevation as listed below: DEPRESSION IN INCHES RADIUS OF AREA DRAINED - FEET 1/2 5 3/4 10 1 15 1-1/4 20 1-1/2 25 B. Prior to trapping drains connected to the sanitary sewer, coordinate requirements with Owners representative. END OF STANDARD 15420 Design & Construction Standards, Revised May 6, 2002 15420-6