MGF TECHNICAL FILE SHEET PILES. Description. Product Notes.

Similar documents
HYDRAULIC WALER SYSTEMS AND SHEET PILES SECTION 5. MGF Sheet Piles 5.1 MGF Trench Sheets 5.2 MGF Walers and Struts 5.3

is generally suitable for trench depths of up to 7.16m, widths of up to 3.92m, pipe lengths of up to 3.0m and a pipe OD of up to 2.6m.

MGF TECHNICAL FILE MGF 203 UC BRACE. Description. Product Notes.

MGF TECHNICAL FILE MGF 305 UC BRACE. Description. Product Notes Issue 4

MGF Laddersafe part of the Shoring Safety Product Range EDGESAFE MGF TECHNICAL FILE Issue 4. Tel

MGF TECHNICAL FILE MANHOLE BRACE. Description. Product Notes.

MGF TECHNICAL FILE TRENCH BOXES. Description. Product Notes.

MGF TECHNICAL FILE ALUMINIUM UTILITY MANHOLE BRACE. Description. Product Notes.

Technical File Section 3: Hydraulic Bracing Systems

MGF TECHNICAL FILE WALERS AND STRUTS. Description. Product Notes.

SHORING SAFETY PRODUCTS SECTION 6

MGF TECHNICAL FILE MGF 400 SERIES STRUT. Description. Product Notes.

PRODUCT BROCHURE EXCAVATION SHORING EXCAVATION SAFETY PIPE STOPPERS OUR CORE VALUES. mgf.ltd.uk

PRODUCT BROCHURE MGF EXCAVATION SUPPORT SYSTEMS EXCAVATION SHORING EXCAVATION SAFETY PIPE STOPPERS OUR CORE VALUES.

New Zealand s Excavation Safety Specialists.

SAFETY SYSTEM. G-Deck Consideration. Manual Handling

MGF GRiPSHORE. safe working environments LIGHTWEIGHT SHORING RANGE VERSATILE SHORING SOLUTIONS FOR SHALLOW EXCAVATIONS

Cantilever Loading Platform Erection Procedures and Guidance Notes

Formwork Direct International. Tel: Heavy Duty Panel System

Features. A Wide Selection of Shapes and Types. Superb Drivability and Water tightness

Hydraulic Aluminum Shoring

Mini-Max Access Tower System Data-Sheets

TEMPORARY EDGE PROTECTION SYSTEM DESCRIPTION CTS. Combisafe International AB

RAPID-EPS PATENT PENDING

INSTRUCTIONmanual. BoSS COMPACT SIDE CANTILEVER TOWER SCAFFOLD 3T Method - Through the Trap Door

Trench Sheeting CONSTRUCTION

BoSS Climalite Camera and lighting tower

ROCKFON SYSTEM T24 X

ROCKFON SYSTEM T24 XL A, E

WILLIAM HARE LIMITED CELLSHIELD LIMITED HEALTH AND SAFETY DEPARTMENT

FD Damper Installation, Operating and Maintenance Instructions

Modular Scaffolding MEKA 48

Summary. Mini KKP - Assembly and operating manuel Pile guide box. Montage. Implementation. Accessories. Technical data

Since it was established in 1989, with a small manufacturing base in Qwa Qwa, Uni-Span has grown to become one

Safety Documents > Safety Manual > Scaffolds

Snappy Ladder 300 Instruction Manual

Selection of Proprietary Shoring Equipment

ROCKFON SYSTEM T24 A/E

Industrial Aluminium Towers

PIANC UK Seminar Design Developments and Specification for Steel. Duncan Nicholson Arup Fellow 9/3/17 ICE London

EASY-SET SCAFFOLD TOWER OPERATIONAL SAFETY AND ASSEMBLY INSTRUCTIONS MODEL: AL-Q0107. Customer Service

EASY-SET SCAFFOLD TOWER OPERATIONAL SAFETY AND ASSEMBLY INSTRUCTIONS MODEL: AL-Q0106. Customer Service

EASY-SET SCAFFOLD TOWER OPERATIONAL SAFETY AND ASSEMBLY INSTRUCTIONS MODEL: AL-Q0108. Customer Service

3T - Through The Trapdoor Method

Span 300 Manual. DESIGNATION EN1004 CEN 1298 IM - en. CEN designation of this instruction manual EN 1298 IM en

System Overview. Calcium Sulphate Interlock System

COMPONENT SCHEDULE SINGLE WIDTH SPAN TOWERS WITH LADDER FRAMES TO BSEN RUNG STARTER FRAMES

FALSEWORK SOLUTIONS: SLAB SHORING SYSTEM - ROYALFRAME50 SERIES

Span 300 Instruction Manual

SCAFFOLDING RUNWAY SYSTEM

Modular Plastic Chambers

SCAFFOLDING RUNWAY SYSTEM

ROCKFON SYSTEM T24 A/E

Industrial Aluminium Towers

Rockfon System Maxispan T24 A, E

PERI UP Easy * The lightweight and fast frame scaffold for safe working on facades

1. Introduction Norms and certifications General information ID Data Load moved from the post to the anchorage point 4

USER S MANUAL HAKI UNIVERSAL

Important: Before You Start

Advantages / Disadvantages of Piling Methods. Continuous Flight Auger (CFA)

MGF EXCAVATION SUPPORT SYSTEMS MGF EXCAVATION SUPPORT SYSTEMS: Excavation Safety / Temporary Works Presentation

WORK BELOW LOWEST FLOOR FINISH 1/7 230, , , FRAME 2/6 96, , ,056.00

(c) Presentation of Information. Information is presented in several forms as follows:

Modular Scaffold MEKA 48

Excavations. OSHA Office of Training and Education 1

SECTION 20 LOADING AND SECURING OF LOADS

GROUND RELEASE SHACKLE

Installation Manual. Orion. TL-3 Steel Barrier. VHD (v2)

COLD DEFORMATION: A STRONGER ALTERNATIVE

For more information on Pictura visit CI/SfB (41) R December New. Pictura. High performance cladding

Lesson 2 Substructure. Dr S.Sreenath BSc Engg, MSc Engg, MSc (ICM), MBA, PhD

Edge Support Trench Lining System

Rockfon System T24 Stepped Z D

OPERATING INSTRUCTIONS

Aluminum Hydraulic Shoring

Rail Handling Handbook

Z5028 E3/Ci80 Horizontal bracket Mounting instructions

Modular System Advantages

Shackles. Applications. Range. Design. CAD drawings. Finish

Span 500. Elite Instruction Manual. DESIGNATION SPAN 500 Double Width EN /12 XXXD SPAN 500 Single Width EN /8 XXXD

LEWIS Miniscaff Folding Tower Assembly Guide

STAIRMAX 700. Camlock Guardrail Aluminium Tower 3T - Through the Trapdoor USER GUIDE

Drexus Pave Drain. Linear Channel. Water Management. Water Linear Management Drainage Design Guide Drexus Pave Drain Linear Drainage Channel

Manufacturing Capabilities. Very few companies in the industry are able to provide the same extent of services under one roof

Lifting Appliances of Ships and Offshore Installations

PACIFIC SHORING, LLC ALUMINUM SHORING PRODUCTS ALUMINUM S-PANEL SHIELDS. TABULATED DATA Effective April 01, 2014

SECTION 31 ACCESS FLOORS

BONDEK PLUS USER & INSTALLATION GUIDE

Span 400 Series Instruction Manual

Safety First Mobile Towers - 3T Method

Uniclass July 2014 L CI/SfB (52.9) Parade. Stainless Steel and Aluminium Access Covers and Frames Technical Details

WATER & WASTE WATER PROCESS EQUIPMENT

Uniclass L151:P7113 EPIC A41:X724. CI/SfB (17.1) Hn6. Plastic Piling

Technical Data Sheet Products

Cold formed steel sheet piles. Edition 2013

Installation Data for Elliptical Pipes. PD 29 rev E 20/09/05

Span 400 Instruction Manual

Technical Data Sheet. Mass 10 Mass 25 Mass 50 M AT 125. Eurocode Compliant. T E C H N I C A L D A T A S H E E T Mass 10. MU Bridging Compact Bridging

MiniMax USER GUIDE. Mobile Aluminium Trade Quality Access Tower System. 3T - Through The Trapdoor Method

Multidirectional_scaffolding MP

Transcription:

Description MGF interlocking steel sheet piles are a high strength sheeting system generally specified to support the vertical faces of large excavations between 4m and 13m in depth. The piles are fully compatible with the MGF shoring product range. Interlocking piles should be specified to prevent water ingress where significant groundwater is anticipated. They are installed using specialist equipment such as impact hammers, vibrating pile drivers or hydraulic presses (subject to suitability of the equipment for driving the piles into the anticipated ground ). The piles are sourced in 0.5m increments of length from major EU steel mills in grade S390 (BS EN 10248 Part 1). Handling holes are provided as standard at one end of the sheet. MGF design and specify the piles in accordance with the relevant standards and guidance documents listed in section 1. MGF can supply the piles with a range of compatible lifting chains, Quick Release Shackles, extractors, Edgesafe edge protection panels, Laddersafe access platforms and GRP or wooden pole ladders and Davitsafe retrieval/fall arrest systems. Product Notes 1. Interlocking steel sheet piles should only be specified, installed and removed by competent persons using specialist equipment selected to suit the size of sheet pile and the anticipated ground / site constraints. 2. Sheet piles are heavy and difficult to handle/pitch on site and these operations should only be carried out by experienced banksmen. Always ensure that the excavator has sufficient reach to safely lift the sheets, the piles are not lifted over personnel and that the trailing ropes on Quick Release Shackles cannot snag. Great care should be taken to avoid trapping fingers whilst pitching the piles. Additional care must be taken in windy when it is recommended that at least 2 persons are used to pitch the piles. 3. A range of corner piles are available when significant groundwater is anticipated to maintain full interlocks along the perimeter of cofferdam structures. Waterproof clutch sealants can be supplied by MGF to provide additional water tightness. 4. For cantilevered sheet pile wall designs a relevant borehole log must always be provided extending well beyond the toe of the sheet. 5. When stacking piles on site it is recommended that they are placed in bundles of no more than 6 sheets and staggered on timber spacers to allow for ease of handling and to minimise the risk of trapping hands/fingers. 6. Other pile lengths, profiles and grades are available upon request. 7. In order to assist installation MGF can supply guide walings. For availability and details contact MGF direct. 8. Sheet piles must only be removed using MGF extractors. Use of a quick release shackle for extraction will lead to damage of the spring mechanism. 9. Interlocking sheet piles are often specified for permanent works applications and are capable of providing significant vertical foundation support to structures. Contact MGF Design for more details. design@mgf.ltd.uk 5.1.1

Sheet Type Material Grade Max SWL (knm/m) Temporary Permanent* Section Modulus (cm 3 /m) Moment of Inertia (cm 4 /m) Weight per m (kg/m) Weight per m 2 (kg/m 2 ) GU8N S390 GP 223.3 (103.8) 200.2 (88.8) 770 (356) 12010 (3837) 48.5 80.9 GU13N S390 GP 368.3 (180.1) 330.2 (166.8) 1270 (624) 26590 (8598) 59.9 99.8 GU16N S390 GP 484.3 (215.4) 434.2 (193.8) 1670 (746) 35950 (10972) 72.6 121.0 GU18N S390 GP 522.0 (220.6) 468.0 (198.4) 1800 (763) 38650 (11383) 76.9 128.2 GU21N S390 GP 597.4 (243.4) 535.6 (219.0) 2060 (842) 46380 (13326) 81.9 136.5 GU23N S390 GP 677.2 (253.5) 607.1 (228.0) 2335 (877) 52510 (14187) 90.4 150.7 PU28-1 S390 GP 774.2 (262.3) 696.8 (236.1) 2680 (908) 60850 (15335) 97.4 162.3 PU32 S390 GP 924.4 (287.9) 832.0 (259.1) 3200 (996) 72320 (17226) 114.1 190.2 N.B. - Values in brackets apply when sheets are not fully interlocked * Permanent capacity does not take into account loss of thickness due to corrosion for further details please contact MGF Design PU28-1 Sheet Pile also known as GU27N PU32N Sheet Pile also known as GU32N GU8N product ID - 3.11 lengths: 5.0m for easy driving GU13N product ID - 3.12 lengths: 6.0m for easy to normal driving GU16N product ID - 3.13 lengths: 7.0m for normal driving 5.1.2 Tel. 0808 1153 122

GU18N product ID - 3.18 lengths: 7.0m for normal driving N.B. Choice of a sheet profile is normally governed by driveability considerations GU21N product ID - 3.14 lengths: 7.0m for normal to hard driving GU23N product ID - 3.19 lengths: 8.0m for hard driving PU28-1 product ID - 3.15 lengths: 8.0m for hard driving Further sheet lengths can be supplied. Please contact MGF for details design@mgf.ltd.uk 5.1.3

PU32 product ID - 3.17 lengths: 8.0m for hard driving Each sheet is supplied with Φ40 handling hole compatible with MGF and 6t pitching shackles and extractors. Extra holes can be provided upon request. Corner Piles Interlock Detail The interlock allows for up to 5 horizontal deviation between each successive sheet. BS20 / C14 The BS20 Corner Pile is suitable for 90 internal corners and is compatible with all the MGF pile profiles. Angle = 90 Mass per Metre = 14.4kg/m BS20 / C14 Omega The Omega Corner Pile is suitable for 90 to 135 internal corners and is compatible with all the MGF pile profiles. Angle = 90-135 Mass per Metre = 18.0kg/m Omega E22 / C9 The E22 / C9 Corner Pile is suitable for 90 internal corners and is compatible with all the MGF pile profiles. The Corner Pile is welded to the pan of an interlocked pile to give added flexibility for interlocking sheet frames. Angle = 90 Mass per Metre = 9.3kg/m E22 / C9 5.1.4 MGF CAD blocks are available to assist with sizing of interlocked cofferdams utilising various combinations of corner piles. Tel. 0808 1153 122

Extractors MGF manufacture and supply 6t SWL pile extractors for the safe removal of MGF sheet piles. Extractors should always be inspected for damage prior to each use. Prior to extraction ensure that the pin is located in the pile/ sheet handling hole with an r-clip attached, and fully locked to prevent accidental release during extraction. Extractors are designed to cope with large extraction forces but must not be violently shaken or snatched. Desc. Product ID Weight (kg) 6t 2.406 27 Quick Release Shackles MGF manufacture and supply 6t Quick Release Shackles (QRS s) for the safe and efficient handling and pitching of MGF sheet piles. MGF QRS s are supplied with rope lines to allow the release of piles/sheets once pitched. All MGF pitching shackles feature a simple safety mechanism that prevents the accidental release of the shackle in the event the rope snags. A short length of chain is attached from the lever arm of the shackle to a metal ring, to which the nylon rope line is attached. When this is in use it ensures that the rope cannot snag and release the mechanism. QRS s should always be inspected for damage prior to each use - especially the spring mechanism, which can be easily damaged by use as an extractor (for which they are not designed). They must not be violently shaken or snatched prior to lifting piles always ensure pin is fully engaged. Desc. Product ID Weight (kg) 6t 2.106 26 design@mgf.ltd.uk 5.1.5

MGF Trench Sheets and Walers 5.1.6 Tel. 0808 1153 122