UMWELT 75 YORK ST TERALBA. Australian Institute of Energy - Peter Jamieson. April 2014

Similar documents
CIRS: Regenerative Sustainability

CIRS: Regenerative Sustainability

ENVIRONMENTALLY SUSTAINABLE CONSTRUCTION

What you need to know about 6 Star. 6 Star. for new homes, home renovations, alterations, additions and relocations

Social Housing. York Street, Dublin SEÁN HARRINGTON ARCHITECTS

CB04. Outback House. Case Study. Creative Spaces Australia. by Casey Brown Architecture

Complying with insulation requirements for houses in Northland

THE IMPACT OF GLAZING SELECTION ON DAYLIGHTING AND ENERGY PERFORMANCE FOR AN OFFICE BUILDING IN CANBERRA

A place for the future

Solar Energy System of the Month: Zero-energy house with photovoltaics and heat pump

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

CLIMATE. Eco-Building Cuts CO2 87%, Electricity 82%, Gas 87% and Water 72%: Eco-Building - Council House 2 (CH2) New Municipal Office Building

Passive House Project documentation

Residential Building Design Approval Procedure

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

The Renner Residence 2009 Mike and Elida Renner

The Hive Sustainability Trail - Supporting Notes

Achieving Zero Carbon for Buildings in a Densely Populated City and a Subtropical Climate. Guiyi LI Construction Industry Council

Design Standard Sustainability

Building regulations now in force

EXTERNAL SHADING DEVICES

Winner of CIBSE Building Performance Award Project of the Year (Public use) 2017 Keynsham Civic Centre

Aurora the new standard of living.

SOLAR PHOTOVOLTAIC ENERGY

OKO House by YOUMEHESHE architects

Sonoma County Energy Independence Program APPENDIX A ELIGIBLE IMPROVEMENTS

DISCOVERIES AT NET ZERO. Michael Leckman Diamond Schmitt Architects Chris Piche Integral Group

The Journey for 5 Stars. Vince Persi, Swinburne University Major Projects Mark O Dwyer H2o Architects

The case for research

Case Studies for Radiant Cooling in Hot & Humid Climate

Modeling the Brillhart House

UT Zero-Energy House Screen House University of Tennessee, Knoxville Arc 572 I Spring 2008

from June 5 th, 2016 until June 10 th, 2016 Business Travel Program of the German Chambers of Commerce

A STUDY OF WALL SURFACE TEMPERATURE VARIATIONS FOR HOUSING IN MODERATE CLIMATES

CSIRO Energy Centre Newcastle, New South Wales, Australia

171: An urban office designed for the southern Brazilian climate

ACAA Initial Entry Brookfield Multiplex Melbourne Convention Centre Project

Environmental & Sustainability Policy Statement

Institute of Marine & Antarctic Studies

TIPS FOR ENERGY SAVING IN OLD AND NEW HOMES

The Embassy of the Kingdom of the Netherlands, Amman - Jordan

INCREASE THE VALUE AND COMFORT OF YOUR HOME. Saving Energy, Saves Money. and lower monthly costs with energy efficiency features.

VANTAGE ENERGY HIGH PERFORMANCE WINDOWS AND DOORS FOR EFFICIENCY & COMFORT

Speakers. Scott Shell, AIA, LEED AP Principal EHDD Architecture Principal-in-Charge

William McCormack Place Stage 2 Project type: Commercial

BARANGAROO SUSTAINABILITY IN PRACTICE

A COMPARATIVE STUDY OF THE THERMAL PERFORMANCE OF CAVITY AND BRICK VENEER CONSTRUCTION

Zero Carbon Building. Christopher TO Construction Industry Council

10 tips from your Architect

Case Study Indira Paryavaran Bhawan

RESIDENTIAL BUILDING PLAN APPROVAL PROCEDURE

Location #1 Introduction

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 01 Aug Energy target.

Demonstration of modeling of radiant cooling system in design builder. Prashant Bhanware & Bharath Reddy

Implementing sustainable practices and measuring our progress

Renewable Heat for Renewable Cities: Geoexchange Heating and Cooling: Introduction and Case Study of St Peters College Sports Centre

UK-GBC ON SITE LEARNING CASE STUDY EBURY STREET

SMART SOLUTIONS DOUBLE GLAZING SOLAR COMFORT TINTING GLASS ASK OUR SALES REPRESENTATIVES ABOUT. Reduce your 23% energy costs * by as much as

Energy Statement. Gainsford Road. For Pocket Living. XCO2 energy. May 2016

SOLAR XXI: A Portuguese Office Building towards Net Zero-Energy Building

Chapter 7. Passive Solar Contents

UT Zero-Energy House Layer House University of Tennessee, Knoxville Arc 572 I Spring 2008

The Role of Thermal Potential in Enhancing Energy Efficiency / Productivity

Sustainable housing competition case study House 17.5 S. Broome, Australia

Low2No Implementation of sustainable principles after design competition

Proceedings of BS2013: 13th Conference of International Building Performance Simulation Association, Chambéry, France, August 26-28

Passivhaus Project Documentation Wrexham Passivhaus

ENVIRONMENTAL & SUSTAINABILITY POLICY

SURNA Grow Facility: Systems Comparison - IEA

The Impact of VISIONWALL High Performance Windows on the Northern Telecom Building in Ottawa, Ontario

PASSIVE HOUSE. is a building, which doesn t need an active type of heating. Dr. Ing Mihail Stancu

BaleHaus by White Design Architects

Leeds Metropolitan University Portland Gate Development - Phase 1 Building Building Sustainability Design Statement

COPYRIGHTED MATERIAL. Contents Overview WHAT'S IN THE SWL PRINTED WHAT'S IN THE SWL ELECTRONIC I NAVIGATION 20 VIII DETAILED DESIGN STRATEGIES E.

Application of Affordable Technologies and Science for Developing Societies

6 S USTAINABLE D EVELOPMENT

SOLAR PASSIVE DESIGN: PRINCIPLES AND PRACTICE

Dogs Trust International Training September Building A Shelter. Paul Wass Dogs Trust

Improvement of thermal performance and energy efficiency of lightweight solar housing for peri-urban villages

Innovative Solutions for Energy Efficient Buildings

Contact Details: Phone Fax . Work Description: New Building Extensions Refurbishment Change of Use. Yes No Method:

An assessment method for residential buildings in Beirut

Sample Questions for Paper 4 Building Services & Environmental Controls

Comparison of the Effects of Various Countermeasures on Energy Consumption in a Residential Building

Those of you from Sydney will probably be familiar with the former pink façade of the Australia Post building on Cleveland Street.

SAMPLE ZNE PRESENTATION

Understanding thermal mass

siting, building and design guidelines April 2017 Newgate, Tarneit Design Guidelines

Effect of Building Orientation and Window Glazing on the Energy Consumption of HVAC System of an Office Building for Different Climate Zones

the bowden centre mt annan botanic garden

Principles of Green Architecture

Designing for Queensland s climate. Designing for Queensland s climate

GeoExchangeTM. A safe, efficient and sustainable choice for heating and cooling your home.

SUSTAINABLE DESIGN STRATEGIES FOR BUILDING DESIGNERS

Single family house in Herselt BE

Design Guidelines. Updated 1 November 2016

European Timber Windows & Doors

Cost-Benefit Analysis of Dwelling Retrofit Options

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home

Building Code requirements for house insulation

Transcription:

UMWELT 75 YORK ST TERALBA Australian Institute of Energy - Peter Jamieson April 2014

Umwelt (Australia) Pty Limited AIE Presentation Locally owned 2 Directors, 3 Shareholders. Environmental consultancy established in March 1993 in Toronto NSW. Opened offices in Perth (March 2007) and Canberra (October 2011). Moved from Toronto after 20 years to new office in Teralba in October 2013. 75 York Street working sustainably Currently employ 100 people in three offices Undertake projects across Australia, NZ, Africa, Malaysia, PNG and Samoa

Umwelt (Australia) Pty Limited AIE Presentation Over the last 20 years we have been given the opportunity and trust to work closely with our clients and stakeholders to achieve quality outcomes, integrating environmental, social and economic considerations. Assisting others in making informed decisions in regard to development and environmental management requires research and innovation. Innovation and sustainable business practices are integral components of our environmental consultancy business.

Teralba NSW

Umwelt Head Office - Teralba NSW

75 York St - Building Design Objectives Umwelt Head Office Provide space for 120 to 130 employees Reuse of existing heritage building Minimise energy footprint site constraints Low energy use for heating, cooling and lighting On-site electricity generation and storage Healthy building natural lighting and limited air conditioning Functional and provide excellent staff amenity Create building that people live with Low maintenance - short and long term Access to public transport, cycleways

Construction commencement

Reuse of Teralba Co-Operative Store

Reuse of Original Timber Trusses

Adaptive Reuse - Separation of Old and New

Design Characteristics Energy Considerations Umwelt Head Office High Thermal Mass 300 mm to 400 mm thick concrete required for earthquake loading so use it Double roof insulation, vented ridge and solar panels Low E Comfort Glass to minimise heat loss Louvers over skylights and western end of building 1.5 metre wide eaves to shade windows and sun shades Passive ventilation - air movement aided ridge windows, louver windows, doors and central stairway

Design Characteristics Building Heating/Cooling Umwelt Head Office Building heating and cooling controlled by: two reverse cycle chiller units (one for server room) 1200 m condenser loop 3 metres below car park 4000 m of hydronic pipes in bottom of thick concrete slabs to heat and cool building 100 metres of chilled beams to offset roof heat on upper floors three evacuated vacuum solar hot water units to assist in heating building BMS system that monitors room temps and regulates heating/cooling system internet accessible Additional heat load - reverse cycle air conditioners

Design Characteristics Energy Considerations Umwelt Head Office Reception building roof garden 40 tonnes of soil and plants over a drainage layer to provide insulation in winter and shading and cooling through latent heat of evaporation in summer Landscaping to shade reception building and main building to minimise heat and glare in the building 28,000 litres of rainwater gravity fed to toilets and landscaping with integrated stormwater drainage that feeds landscaped areas and condenser loop LED lights throughout to minimise energy usage and heat generation

3m Excavation for Condenser Loop

1200 m of 40 mm dia. Condenser Loop Piping

1200 m Condenser Loop Piping as Built

4000 m of 20 mm dia. Hydronic Piping

3800 m Hydronic Piping and Conduits

100 m Chilled Beams and LED Strip Lights

Design Characteristics Energy Generation Umwelt Head Office 25 KW of solar panels producing approximately 35,000 KWh/year of electricity Use of thin film solar panels 30% of energy required to manufacture monocrystalline solar panels energy return 3 years Work better in low light and produce on average 10 to 15% more power than same size monocrystalline system. Solar Panels reduce roof solar radiation loading by 40% 100 kwh of battery capacity provides server/communication approximately 10 to 20 hours of UPS re

Solar panels, extensive glass & louver windows

Concrete mass, louvers and landscaping

Concrete mass, louvers and landscaping

Concrete mass, louvers and landscaping

Concrete mass, louvers and landscaping

Roof top garden on Reception Building

75 York Street Building AIE Presentation Umwelt worked with architect and engineers in design and development of 75 York St Teralba. Umwelt won Sustainable Business Practice category at Lake Macquarie Business Excellence Awards 2013 for its development of 75 York St. 75 York St building also won Heritage Building and Sustainable Building categories of Lower Hunter Urban Design Industry Awards 2013.