GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 East 50 th Street North Sioux Falls, South Dakota Phone Fax

Similar documents
GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 East 50 th Street North Sioux Falls, South Dakota Phone Fax

GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 East 50 th Street North Sioux Falls, South Dakota Phone Fax

GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 East 50 th Street North Sioux Falls, South Dakota Phone Fax

GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 East 50 th Street North Sioux Falls, South Dakota Fax

EXHIBIT G GEOTECHNICAL REPORT (DRAFT)



Geotechnical Engineering Report

CONTRACT 5E-2 APPENDIX A - TEST HOLE LOGS DYREGROV ROBINSON INC. PORTAGE AVE WINSTON DR BOURKEVALE CAVELL PARKSIDE DR ASSINIBOINE AVE

April 7, Webster Street Sub-Surface Stormwater Storage System Bid No Bid Date: 4/13/17 ADDENDUM NO 1

Geotechnical Investigation Long Timber Brewing Building Highway 99 and Kelly Street Monroe, Oregon TABLE OF CONTENTS

Site Location. Figure 1: Site Location Map US-24 and I-275 Interchange Ash Township, Monroe County, Michigan

GEOTECHNICAL INVESTIGATION I-15 SIGN BRIDGES LAS VEGAS EA JANUARY

SECTION 500 STRUCTURES

TRENCH EXCAVATION AND BACKFILL

GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 East 50 th Street North Sioux Falls, South Dakota Phone Fax

Civil Geotechnical Surveying

GEOTECHNICAL ENGINEERING REPORT

CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS IN OPEN CUT

Typical Subsurface Profile. November 28, 2016

GEOTECHNICAL INVESTIGATION PROPOSED OUTFALL LOCATION CITY OF MORGAN S POINT DRAINAGE HARRIS COUNTY, TEXAS REPORT NO

Subsurface Investigation Report. Proposed New 1-Story Building 6447 Grand Avenue Gurnee, Illinois

CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS IN OPEN CUT

CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS IN OPEN CUT

Geotechnical Exploration and Evaluation Report

REPORT OF GEOTECHNICAL EXPLORATION WEST MARJORY AVENUE TAMPA, FLORIDA

GEOTECHNICAL REPORT US 93 WILDLIFE UNDERCROSSINGS North of Wells, Nevada E.A July 2009

May 2, Mr. Tim Kurmaskie, AIA ARCHITECT KURMASKIE ASSOCIATES, INC Washington Street Raleigh, NC

Applied GeoScience, Inc Hammond Dr., Suite 6 Schaumburg, Illinois

REPORT OF GEOTECHNICAL EXPLORATION PEPSI PLACE WATER MAIN REPLACEMENT JACKSONVILLE, FLORIDA E&A PROJECT NO CLIENT ID: 4784

B. Borrow: Satisfactory soil imported from off-site for use as fill or backfill.

November 13, Eckas Water 1514 Ambrosia Court Fort Collins, Colorado Attn: Mr. Wayne Eckas

GEOTECHNICAL ENGINEERING REPORT. KU Parking Lot 300E Southeast of Lied Center Lawrence, Kansas. Project No. D16G1696. KU No. Lz_n/11062.

WILLMER ENGINEERING INC. Willmer Project No Prepared for. Clark Patterson Lee Suwanee, Georgia. Prepared by

DEPARTMENT OF TRANSPORTATION DIVISION: MATERIALS REPORT COVER SHEET. Revised Soil Survey Report November 24, 2015 Matthew G. Moore, P.E.

SECTION UTILITY BACKFILL MATERIALS

SUBSURFACE INVESTIGATION & GEOTECHNICAL RECOMMENDATIONS PROPOSED MONOPOLE CELL TOWER INDIANAPOLIS, INDIANA A&W PROJECT NO: 15IN0464

In preparation for constructing buildings on a property, the builder. Site Preparation CHAPTER

mtec REPORT OF GEOTECHNICAL EXPLORATION FTFA Construct Bin Wall at HERD Eglin AFB, Florida

Geotechnical Engineering Report

Washtenaw Community College Design & Construction Facilities Management 4800 East Huron River Drive Ann Arbor, MI

Thi_ Qar University College of Engineering/Civil Engineering Department. Highway Lectures. Fourth Class. Part #2: - Subgrade Soil

APPENDIX A DRAINAGE STUDY PHASE 2 ALTERNATIVE IMPROVEMENTS CRYSTAL LAKE ALTERNATIVE 4C IMPROVEMENTS LAKEWOOD PIRATELAND SWASH HORRY COUNTY, SC

GEOTECHNICAL REPORT B-1942

Geotechnical Engineering Report

REPORT OF GEOTECHNICAL EXPLORATION KINLOCK FM REPLACEMENT NEW MANHOLE STRUCTURE JACKSONVILLE, FLORIDA ECS PROJECT NO A CLIENT ID: 0199

Geotechnical Engineering Report Proposed Communications Tower Spain Park Site Hoover, Alabama

SECTION SOILS REPORT

REPORT OF GEOTECHNICAL EXPLORATION AND ENGINEERING ANALYSIS

GEOTECHNICAL REPORT US 95 WIDENING ANN ROAD

Geotechnical Engineering Report

Subsurface Environmental Investigation

Geotechnical Engineering Report

Geotechnical Investigation for Navajo Gallup Water Supply Project Reach 26.3

All tests from the new Cells 3 and 4 passed the licence requirements. Please provide approval to begin using the new Cell 3 and Cell 4.

Preliminary Geotechnical Investigation

GEOTECHNICAL ENGINEERING REPORT

Geotechnical Investigation Report

PARKING LOTS 4, 7, AND 8 RECONSTRUCTION REPORT

Soil Survey Summary Report

CONDUCTED FOR: PREPARED FOR: 5 May 2016 YPC Project No. 16GY146

APPENDIX A REPORT OF GEOTECHNICAL EXPLORATION

GEOTECHNICAL SUBSURFACE DATA REPORT

Page 4 Blythe Municipal Airport Project County of Riverside, California December 7, 2015 CTE Job No G

LETTER OF TRANSMITTAL AS REQUESTED FOR REVIEW AND COMMENT FOR APPROVAL PLEASE RECYCLE

GEOTECHNICAL SUBSURFACE INVESTIGATION RECOMMENDATIONS FOR THE TAMUCC MOMENTUM FIELD LIGHT POLES NILE DRIVE CORPUS CHRISTI, TEXAS

Florida s Leading Engineering Source

June i TABLE OF CONTENTS

SECTION FILL AND BACKFILL

GEOTECHNICAL ENGINEERING STUDY. MERIWETHER LEWIS ELECTRIC COOPERATIVE BUILDING Houston/Stewart County Industrial Park AG & E FILE NUMBER:

SECTION EXCAVATION, TRENCHING AND BACKFILL

Geotechnical Engineering Report

GEOTECHNICAL INVESTIGATION ADDENDUM Pavement Improvements for Imperial Avenue, Wake Avenue, and Danenberg Drive, El Centro, California

GEOTECHNICAL STUDY PROPOSED CONCRETE ROADWAY TIKI ISLAND COMMUNITY GALVESTON COUNTY, TEXAS PROJECT NO E

B. The Bidder shall acknowledge receipt of this Addendum in the appropriate space on the Bid Form.

You also requested information regarding a sieve analysis at each boring locations. The test results are attached.

PD - 6 THRUST RESTRAINT DESIGN EQUATIONS AND SOIL PARAMETERS FOR DUCTILE IRON AND PVC PIPE

SUBSURFACE EXPLORATION RECOMMENDATIONS

Report of Geotechnical Study

Table of Contents. Description

REPORT OF GEOTECHNICAL EXPLORATION BYFORGE ENGINEERING FOR REFERENCE ONLY

EXECUTIVE SUMMARY Do not rely on this executive summary Rely on the full report

GEOTECHNICAL INVESTIGATION PROPOSED STORAGE BUILDING AND FUELING FACILTIY WARD ALTERNATIVE ENERGY 614 EAST VINE FORT COLLINS, COLORADO

GFA INTERNATIONAL FLORIDA S LEADING ENGINEERING SOURCE

REPORT OF SUBSURFACE EXPLORATION AND GEOTECHNICAL ANALYSIS DMA TAMPA RED BRICK BUILDING TAMPA, FLORIDA FOR MRI ARCHITECTURAL GROUP, INC.

TRENCH EXCAVATION AND BACKFILL

VOCs, including fuel oxygenates, via EPA Analytical Method The second soil sample from MW-24 (MW ) was analyzed for Total Organic Carbon.

Geotechnical Engineering Report

PROPOSED MONOPOLE TOWER BERKLEY GROUP HIDE-AWAY HILLS SITE 2119 MAYA LANE SUGAR GROVE, OHIO

Applied GeoScience, Inc Hammond Dr., Suite 6 Schaumburg, Illinois

SOIL AND FOUNDATION INVESTIGATION PROPOSED DUPLEX 3966 VRAIN STREET DENVER, COLORADO

GEOTECHNICAL INVESTIGATION

AECOM tel 558 North Main Street fax Oshkosh, Wisconsin 54901

REPORT GEOTECHNICAL STUDY PROPOSED 8-WARD YSA MEETINGHOUSES APPROXIMATELY 1345 EAST 1100 NORTH LOGAN, UTAH LDS PROPERTY NUMBER:

Addendum No. 1 April 7, 2016

April 21, Odom Investments, Inc. Attn: Mr. Jerry Odom 7100 Westwind Dr., Suite 230 El Paso, TX 79912

For. Report of Geotechnical Exploration. University of North Florida Parking Lot 47 Jacksonville, Florida

Geotechnical Investigation

Woodhaven Retirement Community Addition Wentworth Street Livonia, Michigan 48154

For. Report of Geotechnical Exploration. Beaver St Lane Ave to Carnegie St Trans Water Main Project Jacksonville, FL

Transcription:

GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 East 50 th Street North Sioux Falls, South Dakota 57104 Phone 605-335-5512 Fax 605-335-0773 October 28, 2016 City of Vermillion 25 Center Street 57069 Attn: Shane Griese, Utilities Manager Subj: Geotechnical Exploration Proposed Lift Station Replacement & Sanitary Sewer Improvements City of Vermillion This correspondence presents our written report of the geotechnical exploration program for the referenced project. Our work was performed in accordance with your authorization. We are transmitting an electronic copy of our report for your use. An additional copy is also being sent as noted below. We thank you for the opportunity of providing our services on this project and look forward to continued participation during the design and construction phases. If you have any questions regarding this report, please contact our office at (605) 335-5512. Respectfully Submitted, Jared Haskins Jared Haskins, PE Geotechnical Manager Cc: Banner Associates, Inc., Attn: Tanya Miller, PE

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 2 of 16 TABLE OF CONTENTS INTRODUCTION... 4 PROJECT INFORMATION... 4 SCOPE OF SERVICES... 4 SITE & SUBSURFACE CONDITIONS... 5 SITE LOCATION & DESCRIPTION... 5 GROUND SURFACE ELEVATIONS & TEST BORING LOCATIONS... 5 EXISTING PAVEMENT CONDITIONS... 5 SUBSURFACE CONDITIONS... 6 WATER LEVELS... 6 ENGINEERING REVIEW & RECOMMENDATIONS... 7 PROJECT DESIGN DATA... 7 LIFT STATION TEST BORING 1... 7 Dewatering & Stable Condition... 7 Soil Parameters Temporary Shoring Design... 8 UTILITY EXCAVATIONS... 8 Subgrade Soils... 8 Dewatering... 8 Trench Backfill... 9 OSHA SOIL TYPES... 9 PAVEMENT... 10 Discussion... 10 Earthwork Activities... 10 Aggregate Thickness & Geotextile Fabric... 10 Pavement Thickness... 11 CONSTRUCTION CONSIDERATIONS... 11 GROUNDWATER & SURFACE WATER... 11 DISTURBANCE OF SOILS... 11 COLD WEATHER PRECAUTIONS... 12 EXCAVATION SIDESLOPES... 12 OBSERVATIONS & TESTING... 12 Excavation... 13 Testing... 13 SUBSURFACE EXPLORATION PROCEDURES... 13 TEST BORINGS... 13 SOIL CLASSIFICATION... 14 WATER LEVEL MEASUREMENTS... 14 LABORATORY TESTS... 14 LIMITATIONS... 15 STANDARD OF CARE... 16

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 3 of 16 APPENDIX A FIGURE 1 TEST BORING LOCATION MAP (TEST BORINGS 1 & 2) FIGURE 2 TEST BORING LOCATION MAP (TEST BORINGS 3 & 4) FIGURE 3 SOIL PARAMETERS TEST BORING 1 BORING LOGS SOIL CLASSIFICATION SHEET SYMBOLS & DESCRIPTIVE TERMINOLOGY PROCTOR DATA SHEETS

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 4 of 16 GEOTECHNICAL EXPLORATION PROPOSED LIFT STATION REPLACEMENT & SANITARY SEWER IMPROVEMENTS CITY OF VERMILLION VERMILLION, SOUTH DAKOTA GEOTEK #16-C29 INTRODUCTION Project Information This report presents the results of the recent geotechnical exploration program for the proposed lift station replacement and sanitary sewer improvements for the City of Vermillion in. Scope of Services Our work was performed in accordance with the authorization of Shane Griese with the City of Vermillion. The scope of work as presented in this report is limited to the following: 1. To perform four (4) standard penetration test () borings to gather data on the subsurface conditions at the project site. 2. To perform laboratory tests that include moisture content, dry density, sieve analysis (#200 sieve wash), Atterberg limits (liquid and plastic limits), unconfined compressive strength and standard Proctor. 3. To prepare an engineering report that includes the results of the field and laboratory tests as well as our geotechnical engineering opinions and recommendations regarding the following: Existing pavement section; Lift station; Temporary shoring; Potential groundwater control; Utility backfill; Subgrade strength and potential corrective measures; Aggregate section thickness; OSHA soil classes for excavation; Comments regarding factors that may impact the constructability and final performance of the project; Quality control observations and testing.

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 5 of 16 The scope of our work was intended for geotechnical purposes only. This scope of work did not include determining the presence or extent of environmental contamination at the site or to characterize the site relative to wetlands status. SITE & SUBSURFACE CONDITIONS Site Location & Description The existing lift station is located approximately 300 feet south of the intersection of Lincoln Street and Prentis Avenue (east side of Prentis Avenue). The current site features near the location of the existing lift station consist of the following: two (2) residences, a street (Prentis Avenue), grass areas, a sidewalk, a driveway, a tree and a light pole. The sanitary sewer improvements will be performed on Prentis Avenue from the lift station to Clark Street, on Clark Street from Prentis Avenue to Plum Street and on Plum Street from Clark Street to National Street. Ground Surface Elevations & Test Boring Locations We did not determine the ground surface elevations at the test boring locations. Two (2) test boring location maps are attached showing the relative location of the test borings. Existing Pavement Conditions Table 1 summarizes the thickness of the existing pavement and gravel base encountered at the respective test boring locations. Table 1. Thickness of the Existing Pavement & Gravel Base Test Boring Street Asphalt Thickness, in Concrete Pavement, in Gravel Base Thickness, in 1* Prentis Avenue 3 - - 2 Clark Street 6-3 3 Plum Street 1 6-4 Plum Street 1 6 - *Test boring 1 was performed for the lift station within the street.

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 6 of 16 Subsurface Conditions Four (4) test borings were performed on October 11, 2016. Of the four (4) test borings, one (1) test boring (test boring 1) was performed for the lift station and three (3) test borings (test borings 2, 3 and 4) were performed for the sanitary sewer improvements. The subsurface conditions encountered at the test boring locations are illustrated by means of the boring logs included in Appendix A. At test boring 1, existing fill materials extended to a depth of 4 ½ feet. Fine alluvium soils and mixed alluvium soils were encountered beneath the existing fill materials. At a depth of 12 feet, glacial till soils were encountered and extended to the termination depth of the test boring. At test borings 2, 3 and 4, existing fill materials, fine alluvium soils and glacial till soils were encountered beneath the existing pavement section. The glacial till soils were not encountered at test boring 2. The existing fill materials consisted of lean clay soils, clayey sand soils and silty sand soils. The fine alluvium soils consisted of lean clay soils. The mixed alluvium soils consisted of sandy lean clay soils. The glacial till soils consisted of lean clay with sand soils and sandy lean clay soils. The consistency or relative density of the soils is indicated by the standard penetration resistance ( N ) values as shown on the boring logs. A description of the soil consistency or relative density based on the N values can be found on the attached Soil Boring Symbols and Descriptive Terminology data sheet. We wish to point out that the subsurface conditions at other times and locations at the site may differ from those found at our test boring locations. If different conditions are encountered during construction, then it is important that you contact us so that our recommendations can be reviewed. Water Levels Measurements to record the groundwater levels were made at the test boring locations. The time and level of the groundwater readings are recorded on the boring logs. Groundwater was

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 7 of 16 measured at depths varying from 8 feet to 12 feet at test borings 1, 2 and 3. Groundwater did not enter the borehole at test boring 4 at the time of our measurements. The water levels indicated on the boring logs may or may not be an accurate indication of the depth or lack of subsurface groundwater. The limited length of observation restricts the accuracy of the measurements. Long term groundwater monitoring was not included in our scope of work. ENGINEERING REVIEW & RECOMMENDATIONS Project Design Data We understand that the project will consist of replacing an existing lift station with a new lift station. The new lift station will be a steel can and the wet well will be precast concrete. The new lift station will have a depth of approximately 20 feet. We understand that temporary shoring will be needed for the installation of the lift station. The project will also consist of sanitary sewer improvements. The information/assumptions detailed in the project design data section of the report are important factors in our review and recommendations. If there are any corrections or additions to the information detailed in this section, it is important that you contact us so that we can review our recommendations with regards to the revised plans. Lift Station Test Boring 1 Dewatering & Stable Condition The groundwater measurement at test boring 1 indicates that the groundwater level is above the design elevation of the lift station. Therefore, dewatering will likely be needed during the installation of the lift station. It will likely be possible to remove and control water entering the excavation using normal sump pumping techniques due to the low permeable characteristics of the predominant clayey soils encountered at test boring 1. However, if lenses or layers of waterbearing sand soils are encountered, then more extensive dewatering techniques would likely be needed. We would like to point out that lenses of sand were encountered within the fine alluvium soils and mixed alluvium soils from 4 ½ feet to 12 feet. In an effort to provide a stable

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 8 of 16 condition for the installation of the lift station, we recommend placing a minimum of 12 inches of drainage rock at the bottom of the excavation. The drainage rock should be crushed, washed and have 100 percent by weight passing the 1-inch sieve and no more than 5 percent by weight passing the #4 sieve. The drainage rock will also help facilitate drainage at the bottom of the excavation. Soil Parameters Temporary Shoring Design As previously stated, we understand that temporary shoring will be needed for the installation of the lift station. We have provided soil parameters for the design of the temporary shoring (Figure 3 attached at the conclusion of the report). We would like to point out that the parameters shown in Figure 3 are based on a groundwater level of approximately 5 feet. This does not mean that groundwater was encountered at a depth of 5 feet; it is to account for future fluctuations in the groundwater level. We can also provide additional soil parameters if needed. Utility Excavations Subgrade Soils The subgrade soils anticipated at the invert depths for the sanitary sewer will likely consist of clay soils. Where soils having moderate moisture and density values are encountered at the bottom of the trench excavations, it is our opinion that the soils are considered suitable for support of the proposed sanitary sewer, provided they are adequately dewatered, and are not disturbed by construction traffic. Areas of wet or soft soils will likely be encountered at the bottom of the trench excavations. These areas will require subexcavation and trench stabilization methods and materials. Appropriate bedding materials should be used for the sanitary sewer. Dewatering Water may enter the trench excavations as a result of subsurface water, precipitation or surface run off. Dewatering procedures will likely be required in order to control and remove water during the excavation for the sanitary sewer. Where clay soils are encountered, it may be possible to remove and control water entering the excavations using normal sump pumping techniques. However, where waterbearing sand soils are encountered, extensive dewatering

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 9 of 16 techniques will likely be required due to the potentially large volumes of water. The contractor should provide appropriate dewatering methods and equipment. It should be noted that groundwater was measured at depths varying from 8 feet to 12 feet at test borings 1, 2 and 3. Any water that accumulates at the bottom of the excavations should be immediately removed and surface drainage away from the excavations should be provided during construction. Trench Backfill The results of the laboratory moisture content tests generally indicate that the on-site soils (existing fill materials, fine alluvium soils, mixed alluvium soils and glacial till soils) have high moisture content levels. In our opinion, it will be difficult to adjust the moisture content of the on-site soils to a level that will facilitate the specified compaction requirement. With that said, it is our opinion that the on-site soils should not be used as trench backfill. The on-site soils should be replaced by an off-site borrow material. The off-site borrow material should consist of either a granular or clay material. If a granular material is used, then it should consist of a pit-run or processed sand or gravel having a maximum particle size of 3 inches. The granular material can be placed in lifts of up to 1 foot in thickness. If a clay material is selected, then it should consist of a non-organic clay having a liquid limit less than 45. Scrutiny on the clay material s moisture content should be made prior to the acceptance and use. The clay fill should be placed in lifts of up to 6 inches in thickness. The moisture content of the trench backfill soils should be within plus or minus 2 percent of the optimum moisture content as determined by standard Proctor (ASTM:D698). The trench backfill should be compacted to a minimum of 95 percent of standard Proctor density (ASTM:D698). OSHA Soil Types It is our opinion that the existing fill materials, fine alluvium soils and mixed alluvium soils would be classified as Type C soils. The glacial till soils at test boring 3 would also be classified as a Type C soil. The glacial till soils from 12 feet to 19 ½ feet at test boring 1 would be classified as a Type B soil. The glacial till soils from 19 ½ feet to 46 feet at test boring 1 and at test boring 4 would be classified as Type A soils.

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 10 of 16 Pavement Discussion Even though we recommend the use of an off-site borrow material as trench backfill, a portion of the on-site soils will remain within the roadway. Again, the laboratory moisture content tests generally indicate that the on-site soils have high moisture content levels. It is our opinion that the on-site soils will provide low subgrade support for the pavement section. Therefore, it is our opinion that subgrade reinforcement will be needed below the pavement. The subgrade reinforcement should consist of coarse granular subbase overlying a geotextile fabric. Earthwork Activities Low-ground-pressure construction equipment or excavators with smooth-edged buckets should be used for the earthwork activities. The subgrade should not be exposed to heavy construction traffic from rubber tire vehicles. Aggregate Thickness & Geotextile Fabric We recommend that the aggregate section consist of a minimum of 4 inches of aggregate base course material overlying 10 inches of coarse granular subbase. A geotextile fabric should be installed beneath the coarse granular subbase. The thickness of the aggregate base course material is only 4 inches because coarse granular subbase and geotextile fabric is recommended. A thicker layer of aggregate base course material could be used but the thickness of the coarse granular subbase should not be reduced. We recommend that the aggregate base course material meet the requirements of Sections 260 and 882 of the SDDOT Standard Specifications. For the coarse granular subbase, it should consist of crushed quartzite, recycled concrete or a crushed pit-run material meeting the gradation specifications shown in Table 2.

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 11 of 16 Table 2. Granular Subbase Gradation Specifications Sieve Size Percent Passing 4-inch 100 1-inch 40 80 #4 10 50 #40 5 20 #200 0 5 The aggregate base course material and coarse granular subbase should be compacted to a minimum of 97 percent of standard Proctor (ASTM:D698); however, compaction testing of the coarse granular subbase may not be practical due to the large aggregate. Regarding the geotextile fabric, it should consist of Mirafi HP 370, Propex Geotex 3x3 HF, Huesker Comtrac P 45/45 or approved alternative. Pavement Thickness We assume that the pavement thickness will match that of the existing pavement. The asphalt pavement should meet the requirements of sections 320 and 321 for Class G. We recommend that the concrete pavement meet the requirements of Section 380 of the SDDOT Standard Specifications. CONSTRUCTION CONSIDERATIONS Groundwater & Surface Water Water may enter the excavations due to subsurface water, precipitation or surface run off. Any water that accumulates in the bottom of the excavations should be immediately removed and surface drainage away from the excavations should be provided during construction. Disturbance of Soils The soils encountered at the test boring locations are susceptible to disturbance and can experience strength loss caused by construction traffic and/or additional moisture. Precautions

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 12 of 16 will be required during earthwork activities in order to reduce the risk of soil disturbance. Lowground-pressure construction equipment or excavators with smooth-edged buckets should be used for the earthwork activities. Cold Weather Precautions If site preparation and construction is anticipated during cold weather, we recommend all subgrades, slabs and other improvements that may be affected by frost movements be insulated from frost penetration during freezing temperatures. If filling is performed during freezing temperatures, all frozen soils, snow and ice should be removed from the areas to be filled prior to placing the new fill. The new fill should not be allowed to freeze during transit, placement and compaction. Concrete and asphalt should not be placed on frozen subgrades. If subgrades freeze, we recommend that the frozen soils be removed and replaced, or completely thawed. The subgrade soils will likely require reworking and recompacting due to the loss of density caused by the freeze/thaw process. Excavation Sideslopes All excavations must comply with the requirements of OSHA 29 CFR, Part 1926, Subpart P, Excavations and Trenches. This document states that the excavation safety is the responsibility of the contractor. Reference to this OSHA requirement should be included in the project specifications. Observations & Testing This report was prepared using a limited amount of information for the project and a number of assumptions were necessary to help us develop our conclusions and recommendations. It is recommended that our firm be retained to review the geotechnical aspects of the final design plans and specifications to check that our recommendations have been properly incorporated into the design documents. The recommendations submitted in this report have been made based on the subsurface conditions encountered at the test boring locations. It is possible that there are subsurface conditions at the site that are different from those represented by the test borings. As a result, on-

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 13 of 16 site observation during construction is considered integral to the successful implementation of the recommendations. We believe that qualified field personnel need to be on-site at the following times to observe the site conditions and effectiveness of the construction. Excavation We recommend that a geotechnical engineer or geotechnical engineering technician working under the direct supervision of a geotechnical engineer observe all excavations for utilities, slabs and pavements. These observations are recommended to determine if the exposed soils are similar to those encountered at the test boring locations, if unsuitable soils have been adequately removed and if the exposed soils are suitable for support of the proposed construction. Testing After the subgrade is observed by a geotechnical engineer/technician and approved, we recommend a representative number of compaction tests be taken during the placement of the backfill placed below slabs and pavements. The tests should be performed to determine if the required compaction has been achieved. As a general guideline, we recommend at least one (1) test be taken for every 10,000 square feet of embankment fill placed, at least one (1) test for every 500 feet in trench fill, and for every 2-foot thickness of fill or backfill placed. The actual number of tests should be left to the discretion of the geotechnical engineer. Samples of proposed fill and backfill materials should be submitted to our laboratory for testing to determine their compliance with our recommendations and project specifications. SUBSURFACE EXPLORATION PROCEDURES Test Borings We drilled four (4) borings on October 11, 2016 with a truck rig equipped with hollow-stem auger. Soil sampling was performed in accordance with the procedures described in ASTM:D1586. Using this procedure, a 2-inch O.D. split barrel sampler is driven into the soil by a 140-pound weight falling 30 inches. After an initial set of 6 inches, the number of blows required to drive the sampler an additional 12 inches is known as the penetration resistance, or

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 14 of 16 N value. The N value is an index of the relative density of cohesionless soils and the consistency of cohesive soils. In addition, thin walled tube samples were obtained according to ASTM:D1587, where indicated by the appropriate symbol on the boring logs. The test borings were backfilled with on-site materials and some settlement of these materials can be expected to occur. Final closure of the holes is the responsibility of the client or property owner. Soil Classification As the samples were obtained in the field, they were visually and manually classified by the crew chief according to ASTM:D2488. Representative portions of all samples were then sealed and returned to the laboratory for further examination and for verification of the field classification. In addition, select samples were then submitted to a program of laboratory tests. Where laboratory classification tests (sieve analysis and Atterberg limits) have been performed, classifications according to ASTM:D2487 are possible. Logs of the test borings indicating the depth and identification of the various strata, the N value, the laboratory test data, water level information and pertinent information regarding the method of maintaining and advancing the drill holes are also attached in Appendix A. Charts illustrating the soil classification procedures, the descriptive terminology and the symbols used on the boring logs are also attached in Appendix A. Water Level Measurements Subsurface groundwater levels should be expected to fluctuate seasonally and yearly from the groundwater readings recorded at the test borings. Fluctuations occur due to varying seasonal and yearly rainfall amounts and snowmelt, as well as other factors. It is possible that the subsurface groundwater levels during or after construction could be significantly different than the time the test borings were performed. Laboratory Tests Laboratory tests were performed on select samples to aid in determining the index and strength properties of the soils. The index tests consisted of moisture content, dry density, sieve analysis

Proposed Lift Station Replacement & Sanitary Sewer Improvements Page 15 of 16 (#200 sieve wash), Atterberg limits (liquid and plastic limits) and standard Proctor. The strength tests consisted of unconfined compressive strength. The laboratory tests were performed in accordance with the appropriate ASTM procedures. The results of the laboratory tests are shown on the boring logs opposite the samples upon which the tests were performed or on the data sheets included in the Appendix. LIMITATIONS The recommendations and professional opinions submitted in this report were based upon the data obtained through the sampling and testing program at the test boring locations. We wish to point out that because no exploration program can totally reveal the exact subsurface conditions for the entire site, conditions between test borings and between samples and at other times may differ from those described in our report. Our exploration program identified subsurface conditions only at those points where samples were retrieved or where water was observed. It is not standard engineering practice to continuously retrieve samples for the full depth of the test borings. Therefore, strata boundaries and thicknesses must be inferred to some extent. Additionally, some soils layers present in the ground may not be observed between sampling intervals. If the subsurface conditions encountered at the time of construction differ from those represented by our test borings, it is necessary to contact us so that our recommendations can be reviewed. The variations may result in altering our conclusions or recommendations regarding site preparation or construction procedures, thus, potentially affecting construction costs. This report is for the exclusive use of the addressee and its representatives for use in design of the proposed project described herein and preparation of construction documents. Without written approval, we assume no responsibility to other parties regarding this report. Our conclusions, opinions and recommendations may not be appropriate for other parties or projects.

FIGURE 3. SOIL PARAMETERS TEST BORING 1 Soil Type Geological Origin Depth Below Existing Grade, ft At-Rest, pcf Active, pcf Passive, pcf Drained Submerged Drained Submerged Drained Submerged Clayey/Silty Sand Fill 0-4.5 65 95 45 85 330 160 Lean Clay/Sandy Fine Alluvium & 4.5-12 90 110 75 100 205 100 Lean Clay Mixed Alluvium Sandy Lean Clay Glacial Till 12-46 85 105 65 95 260 135 Note: As stated in the geotechnical report, the parameters are based on a groundwater level of approximately 5 feet. Therefore, the submerged values should be used below a depth of 5 feet. Soil Type Geological Origin Depth Below Existing Grade, ft Effective Unit Weight, pcf* Cohesion, psf Friction Angle, degrees Lateral Soil Modulus, K, pci Strain @ 50%, E50 Clayey/Silty Sand Fill 0-4.5 120-28 20-8 Lean Clay/Sandy Fine Alluvium & Lean Clay Mixed Alluvium 4.5-12 60 250 15 50 0.020 - Sandy Lean Clay Glacial Till 12-19.5 66 800 20 250 0.010 - Sandy Lean Clay Glacial Till 19.5-46 66 2800 20 900 0.005 - *Based on a groundwater level of approximately 5 feet. Relative Density, DR, %

GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 E. 50th St. N. Sioux Falls SD 57104 605-335-5512 Fax 605-335-0773 www.geotekeng.com GEOTECHNICAL TEST BORING LOG GEOTEK # 16-C29 BORING NO. 1 (1 of 2) PROJECT in FEET 2 Proposed Lift Station Replacement & Sanitary Sewer Improvements, City of Vermillion, Vermillion, SD DESCRIPTION OF MATERIAL FILL, MOSTLY CLAYEY SAND: a little gravel, dark brown, moist, 3" of asphalt at the surface FILL, MOSTLY SILTY SAND: fine to medium grained, brown, moist GEOLOGIC ORIGIN FILL FILL N 4 WL SAMPLE 1 2 HSA LABORATORY TESTS NO. TYPE WC D LL PL QU 4½ LEAN CLAY: mottled brown and gray, wet, soft, a few lenses of sand (CL) FINE ALLUVIUM 4 3 4 4 27 97 9½ SANDY LEAN CLAY: mottled brown and gray, wet, soft, a few lenses of sand (CL) MIXED ALLUVIUM 2 5 26 97 36 15 12 SANDY LEAN CLAY: a little gravel, mottled brown and gray, moist, firm to stiff, percent passing the #200 sieve = 63% (at 13') (CL) GLACIAL TILL 6 6 24 104 1700 6 7 22 105 36 16 GEOTECHNICAL TEST BORING 16-C29.GPJ GEOTEKENG.GDT 10/28/16 DATE 10-11-16 TIME 10:46 am WATER LEVEL MEASUREMENTS SAMPLED 46 CASING CAVE-IN 39 WATER LEVEL 8 11 14 8 9 START 10-11-16 23 METHOD 3.25" ID Hollow Stem Auger CREW CHIEF 104 COMPLETE Mike Wagner 5400 10-11-16 10:36 am

GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 E. 50th St. N. Sioux Falls SD 57104 605-335-5512 Fax 605-335-0773 www.geotekeng.com GEOTECHNICAL TEST BORING LOG GEOTEK # 16-C29 BORING NO. 1 (2 of 2) PROJECT in FEET 29½ Proposed Lift Station Replacement & Sanitary Sewer Improvements, City of Vermillion, Vermillion, SD DESCRIPTION OF MATERIAL SANDY LEAN CLAY: a little gravel, mottled brown and gray, moist, firm to stiff, percent passing the #200 sieve = 63% (at 13') (CL) (Continued from previous page) SANDY LEAN CLAY: a little gravel, dark gray, moist, stiff to very stiff, percent passing the #200 sieve = 64% (at 35') (CL) GEOLOGIC ORIGIN GLACIAL TILL GLACIAL TILL N 19 WL SAMPLE 10 LABORATORY TESTS NO. TYPE WC D LL PL QU 13 11 21 108 5600 13 12 46 Bottom of borehole at 46 feet. 13 13 GEOTECHNICAL TEST BORING 16-C29.GPJ GEOTEKENG.GDT 10/28/16 DATE 10-11-16 TIME 10:46 am WATER LEVEL MEASUREMENTS SAMPLED 46 CASING CAVE-IN 39 WATER LEVEL 8 START 10-11-16 COMPLETE METHOD 3.25" ID Hollow Stem Auger CREW CHIEF Mike Wagner 10-11-16 10:36 am

GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 E. 50th St. N. Sioux Falls SD 57104 605-335-5512 Fax 605-335-0773 www.geotekeng.com GEOTECHNICAL TEST BORING LOG GEOTEK # 16-C29 BORING NO. 2 (1 of 1) PROJECT in FEET Proposed Lift Station Replacement & Sanitary Sewer Improvements, City of Vermillion, Vermillion, SD DESCRIPTION OF MATERIAL FILL, MOSTLY LEAN CLAY: dark brown, moist, 6" of asphalt and 3" of gravel at the surface GEOLOGIC ORIGIN FILL N WL SAMPLE 1 HSA 19 LABORATORY TESTS NO. TYPE WC D LL PL QU 105 3½ LEAN CLAY: very dark brown, moist, firm, (CL) FINE ALLUVIUM 10 2 8 BAG 23 6 3 23 8 4 22 9½ LEAN CLAY: mottled brown and gray, wet, soft, (CL) FINE ALLUVIUM 3 5 33 9 BAG 2 6 36 16 Bottom of borehole at 16 feet. 2 7 GEOTECHNICAL TEST BORING 16-C29.GPJ GEOTEKENG.GDT 10/28/16 DATE 10-11-16 TIME 12:05 pm WATER LEVEL MEASUREMENTS SAMPLED 16 CASING CAVE-IN 11 WATER LEVEL 9 START 10-11-16 COMPLETE METHOD 3.25" ID Hollow Stem Auger CREW CHIEF Mike Wagner 10-11-16 11:57 am

GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 E. 50th St. N. Sioux Falls SD 57104 605-335-5512 Fax 605-335-0773 www.geotekeng.com GEOTECHNICAL TEST BORING LOG GEOTEK # 16-C29 BORING NO. 3 (1 of 1) PROJECT in FEET 1 3½ Proposed Lift Station Replacement & Sanitary Sewer Improvements, City of Vermillion, Vermillion, SD DESCRIPTION OF MATERIAL FILL, MOSTLY LEAN CLAY: dark brown, moist, 1" of asphlt and 6" of concrete at the surface LEAN CLAY: very dark brown, moist, firm, (CL) LEAN CLAY: mottled brown and gray, moist to wet, soft to firm, (CL) GEOLOGIC ORIGIN FILL FINE ALLUVIUM FINE ALLUVIUM N 5 6 WL SAMPLE 1 2 3 HSA 24 24 20 LABORATORY TESTS NO. TYPE WC D LL PL QU 4 4 30 11 SANDY LEAN CLAY: a trace of gravel, mottled brown and gray, wet, soft, (CL) GLACIAL TILL 4 5 30 4 6 25 16 Bottom of borehole at 16 feet. 4 7 GEOTECHNICAL TEST BORING 16-C29.GPJ GEOTEKENG.GDT 10/28/16 DATE 10-11-16 TIME 1:40 pm WATER LEVEL MEASUREMENTS SAMPLED 16 CASING CAVE-IN 14 WATER LEVEL 12 START 10-11-16 COMPLETE METHOD 3.25" ID Hollow Stem Auger CREW CHIEF Mike Wagner 10-11-16 12:45 pm

GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 E. 50th St. N. Sioux Falls SD 57104 605-335-5512 Fax 605-335-0773 www.geotekeng.com GEOTECHNICAL TEST BORING LOG GEOTEK # 16-C29 BORING NO. 4 (1 of 1) PROJECT in FEET 1 Proposed Lift Station Replacement & Sanitary Sewer Improvements, City of Vermillion, Vermillion, SD DESCRIPTION OF MATERIAL FILL, MOSTLY LEAN CLAY: dark brown, moist, 1" of asphlt and 6" of concrete at the surface LEAN CLAY: mottled brown and gray, moist, soft to firm, (CL) GEOLOGIC ORIGIN FILL FINE ALLUVIUM N 4 WL SAMPLE 1 2 HSA 18 21 LABORATORY TESTS NO. TYPE WC D LL PL QU 102 8 BAG 5 3 29 7 4 20 9½ LEAN CLAY WITH SAND: a little gravel, mottled brown and gray, moist, stiff, (CL) GLACIAL TILL 10 5 20 9 BAG 10 6 19 16 Bottom of borehole at 16 feet. 11 7 GEOTECHNICAL TEST BORING 16-C29.GPJ GEOTEKENG.GDT 10/28/16 DATE 10-11-16 TIME 2:19 pm WATER LEVEL MEASUREMENTS SAMPLED 16 CASING CAVE-IN 14 WATER LEVEL none START 10-11-16 COMPLETE METHOD 3.25" ID Hollow Stem Auger CREW CHIEF Mike Wagner 10-11-16 2:19 pm

SOIL CLASSIFICATION CHART SYMBOLS MAJOR DIVISIONS GRAPH LETTER TYPICAL DESCRIPTIONS GRAVEL AND GRAVELLY SOILS CLEAN GRAVELS (LITTLE OR NO FINES) GW GP WELL-GRADED GRAVELS, GRAVEL - SAND MIXTURES, LITTLE OR NO FINES POORLY-GRADED GRAVELS, GRAVEL - SAND MIXTURES, LITTLE OR NO FINES COARSE GRAINED SOILS MORE THAN 50% OF COARSE FRACTION RETAINED ON NO. 4 SIEVE GRAVELS WITH FINES (APPRECIABLE AMOUNT OF FINES) GM GC SILTY GRAVELS, GRAVEL - SAND - SILT MIXTURES CLAYEY GRAVELS, GRAVEL - SAND - CLAY MIXTURES MORE THAN 50% OF MATERIAL IS LARGER THAN NO. 200 SIEVE SIZE SAND AND SANDY SOILS CLEAN SANDS (LITTLE OR NO FINES) SW SP WELL-GRADED SANDS, GRAVELLY SANDS, LITTLE OR NO FINES POORLY-GRADED SANDS, GRAVELLY SAND, LITTLE OR NO FINES MORE THAN 50% OF COARSE FRACTION PASSING ON NO. 4 SIEVE SANDS WITH FINES (APPRECIABLE AMOUNT OF FINES) SM SC SILTY SANDS, SAND - SILT MIXTURES CLAYEY SANDS, SAND - CLAY MIXTURES ML INORGANIC SILTS AND VERY FINE SANDS, ROCK FLOUR, SILTY OR CLAYEY FINE SANDS OR CLAYEY SILTS WITH SLIGHT PLASTICITY FINE GRAINED SOILS SILTS AND CLAYS LIQUID LIMIT LESS THAN 50 CL INORGANIC CLAYS OF LOW TO MEDIUM PLASTICITY, GRAVELLY CLAYS, SANDY CLAYS, SILTY CLAYS, LEAN CLAYS OL ORGANIC SILTS AND ORGANIC SILTY CLAYS OF LOW PLASTICITY MORE THAN 50% OF MATERIAL IS SMALLER THAN NO. 200 SIEVE SIZE SILTS AND CLAYS LIQUID LIMIT GREATER THAN 50 MH CH INORGANIC SILTS, MICACEOUS OR DIATOMACEOUS FINE SAND OR SILTY SOILS INORGANIC CLAYS OF HIGH PLASTICITY OH ORGANIC CLAYS OF MEDIUM TO HIGH PLASTICITY, ORGANIC SILTS HIGHLY ORGANIC SOILS PT PEAT, HUMUS, SWAMP SOILS WITH HIGH ORGANIC CONTENTS NOTE: DUAL SYMBOLS ARE USED TO INDICATE BORDERLINE SOIL CLASSIFICATIONS

BORING LOG SYMBOLS AND DESCRIPTIVE TERMINOLOGY SYMBOLS FOR DRILLING AND SAMPLING Symbol Bag CS DM FA HA HSA LS N NMR NSR SH SS WL Definition Bag sample Continuous split-spoon sampling Drilling mud Flight auger; number indicates outside diameter in inches Hand auger; number indicates outside diameter in inches Hollow stem auger; number indicates inside diameter in inches Liner sample; number indicates outside diameter of liner sample Standard penetration resistance (N-value) in blows per foot No water level measurement recorded, primarily due to presence of drilling fluid No sample retrieved; classification is based on action of drilling equipment and/or material noted in drilling fluid or on sampling bit Shelby tube sample; 3-inch outside diameter Standard penetration test (N-value) using standard split-spoon sampler Split-spoon sample; 2-inch outside diameter unless otherwise noted Water level directly measured in boring Water level symbol SYMBOLS FOR LABORATORY TESTS Symbol WC D LL PL QU Definition Water content, percent of dry weight; ASTM:D2216 Dry density, pounds per cubic foot Liquid limit; ASTM:D4318 Plastic limit; ASTM:D4318 Unconfined compressive strength, pounds per square foot; ASTM:D2166 DENSITY/CONSISTENCY TERMINOLOGY Density Consistency Term N-Value Term Very Loose 0-4 Soft Loose 5-8 Firm Medium Dense 9-15 Stiff Dense 16-30 Very Stiff Very Dense Over 30 Hard Term Dry Frozen Moist Waterbearing Wet Lamination Layer Lens DESCRIPTIVE TERMINOLOGY Definition Absence of moisture, powdery Frozen soil Damp, below saturation Pervious soil below water Saturated, above liquid limit Up to ½ thick stratum ½ to 6 thick stratum ½ to 6 discontinuous stratum PARTICLE SIZES Term Particle Size Boulder Over 12 Cobble 3 12 Gravel #4 3 Coarse Sand #10 #4 Medium Sand #40 #10 Fine Sand #200 #40 Silt and Clay passes #200 sieve GRAVEL PERCENTAGES Term Range A trace of gravel 2-4% A little gravel 5-15% With gravel 16-50%

DRY DENSITY (pcf) GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 East 50th Street North Sioux Falls, SD 57104 605-335-5512 Fax 605-335-0773 www.geotekeng.com REPORTED TO: PROJECT: 16-C29 COPIES TO: {CustomerName} {FullName} {AddressLine1} {AddressLine2} {AddressLine3} {City}, {State} {ZIPCode} {JobSite} {JobAddress} {JobAddress2} {JobCity}, {JobState} {PONumber} MOISTURE - DENSITY TEST REPORT DATE REPORTED: ######## SAMPLE DATA Sample No.: 1 Date Received: ######## ASTM Test Method: D698B Date Tested: 10/18/2016 Soil Classification: Lean Clay, dark brown (CL) - 1 Remarks: SB 2 (1' - 7') TEST DATA 140 135 130 125 120 Curve for 100% saturation for specific gravity equal to 2.65 Maximum Density, pcf: Optimum Moisture, %: Percent Passing, %: 3/4": 3/8": #4: #200: Atterberg Limits (ASTM: D4318): Liquid Limit: Plastic Limit: Plasticity Index: 102.3 20.0 100 100 100 90 115 110 105 100 95 90 85 80 0 5 10 15 20 25 30 35 40 MOISTURE CONTENT (%) Matthew Thompson, P.E.: Project Manager

DRY DENSITY (pcf) GEOTEK ENGINEERING & TESTING SERVICES, INC. 909 East 50th Street North Sioux Falls, SD 57104 605-335-5512 Fax 605-335-0773 www.geotekeng.com REPORTED TO: PROJECT: 16-C29 COPIES TO: {CustomerName} {FullName} {AddressLine1} {AddressLine2} {AddressLine3} {City}, {State} {ZIPCode} {JobSite} {JobAddress} {JobAddress2} {JobCity}, {JobState} {PONumber} MOISTURE - DENSITY TEST REPORT DATE REPORTED: ######## SAMPLE DATA Sample No.: 2 Date Received: ######## ASTM Test Method: D698B Date Tested: 10/18/2016 Soil Classification: Lean Clay with Sand, brown (CL) - 2 Remarks: SB 4 (2' - 9') TEST DATA 140 135 130 125 120 Curve for 100% saturation for specific gravity equal to 2.65 Maximum Density, pcf: Optimum Moisture, %: Percent Passing, %: 3/4": 3/8": #4: #200: Atterberg Limits (ASTM: D4318): Liquid Limit: Plastic Limit: Plasticity Index: 103.0 16.9 100 100 100 82 115 110 105 100 95 90 85 80 0 5 10 15 20 25 30 35 40 MOISTURE CONTENT (%) Matthew Thompson, P.E.: Project Manager