Hilti HST3 Metal Expansion Anchor

Similar documents
HST3 Metal expansion anchor

HSA Carbon steel with DIN 125 washer. HSA-R Stainless steel A4 with DIN 125 washer. HSA-R2 Stainless steel A2 with DIN 125 washer

HST-3 EXPANSION ANCHOR. Technical Datasheet Update: Apr-18

HST-3 EXPANSION ANCHOR. Technical Datasheet Update: Apr-18

HST2 Expansion anchor Everyday standard expansion anchor for cracked concrete

HSC UNDERCUT ANCHOR. Technical Datasheet Update: Jul-18

Anchor HSA Fastening. Technology Manual HSA. Stud anchor. Version /

Hilti HIT-RE 500 V3 mortar with HIT-V rod

Anchor Fastening Technology Manual. HIT-HY 170 mortar with rebar (as anchor) Hilti HIT-HY 170 mortar with rebar (as anchor) Version

HKD Push-in anchor, Single anchor application

HKD Push-in anchor, Single anchor application

HILTI HSC UNDERCUT ANCHOR. Technical Datasheet Update: Sep-18

HST Carbon steel. HST-R Stainless steel HST-HCR High corrosion resistance steel. Fire resistance

HKD Push-in anchor, Single anchor application

Hilti HIT-HY 200 A (R) mortar with HIT-V rods

HVU with HAS/HAS-E rod adhesive anchor system

HVZ (HVU-TZ+HAS-TZ) adhesive anchor system Anchor design (ETAG 001) / Rods&Sleeves / Concrete

HDA-P HDA-PR HDA-PF Anchor for presetting. HDA-T HDA-TR HDA-TF Anchor for through-fasting. Nuclear power plant approval

Hilti HIT-CT 1 with HIT-V

HIT-ICE INJECTION MORTAR. Technical Datasheet Update: Jun-18

HDA UNDERCUT ANCHOR. Technical Datasheet Update: Dec-17

Hilti HIT-HY 170 mortar with HIT-V rod. Anchor Fastening Technology Manual. Hilti HIT-HY 170 with HIT-V HIS-(R)N 03 / /

Hilti HIT-HY 200-R 500 ml foil pack (also available as 330 ml foil pack) Static mixer

Hilti HVU-TZ foil capsule. HAS-TZ HAS-R-TZ HAS-HCR-TZ rod. Shock

Hilti-HY 110 available in 330ml and 500ml foil packs. Static mixer HIT M1. Rebar BSt 500 S

HUS-HR / HUS-CR Screw anchor

Hilti HIT-HY150 Injection Adhesive with HAS-E/ER/EF/HCR and HIS-N/RN

HKD redundant FLUSH ANCHOR. Technical Datasheet Update: Mar-18

HUS3-H 8 / 10 / 14 Carbon steel concrete screw with hexagonal head. HUS3-C 8 / 10 Carbon steel concrete screw with countersunk head

Anchor Fastening Technology Manual 09 / 2012

HUS3 SCREW ANCHOR. Technical Datasheet Update: May-18

Hilti HUS3 SCREW ANCHOR. Technical Datasheet Update: Oct-18

Hilti HIT-ICE with rebar

HIT-RE 500 V3 INJECTION MORTAR. Technical Datasheet Update: Dec-17

Anchor Fastening. Technology Manual HUS3. Screw Anchor HUS3-H 6/8/10/14 HUS3-C 6/8/10 HUS3-HF 8/10/14 HUS3-A 6 HUS3-I 6 HUS3-P 6 HUS3-PS 6 HUS3

HIT-HY 200 INJECTION MORTAR. Technical Datasheet Update: Mar-18

Anchor Fastening Technology Manual 09 / 2012

Hilti HDA Submission Folder

HIT-HY 200 INJECTION MORTAR. Technical Datasheet Update: Dec-17

Hilti HIT-RE 10 mortar Economical epoxy mortar for concrete

HIT-HY 200 INJECTION MORTAR. Technical Datasheet Update: Aug-18

HSV Carbon steel with DIN 125 washer. HSV-BW Carbon steel with DIN 9021 washer and DIN 127b spring washer

HIT-HY 170 INJECTION MORTAR. Technical Datasheet Update: Dec-17

HIT-HY 200-A/R INJECTION MORTAR. Technical Datasheet Update: Oct-18

Anchor Fastening Technology Manual 09 / 2012

HIT-HY 170 INJECTION MORTAR. Technical Datasheet Update: Apr-18

HSV. with DIN 125 washer HSV-BW. Carbon steel. with DIN 9021 washer and DIN 127b spring washer

1 Input data. Profis Anchor Company: Specifier: Address: Phone I Fax: Page: Project: Fastening Point: Date: 19/04/2016

SINGLE ANCHOR USE FOR NON-CRACKED CONCRETE

General Information. Installation Information Design Information Material Information Ordering Information

SUPERPLUS M8-M16. The undercut fixing system that does not require a special setting tool. FUNCTION BENEFITS

Hilti HSA Submission Folder

PRODUCT DATA SHEET THROUGH BOLTS. facebook.com/sormat youtube.com/sormatfixing SORMAT Product data sheet 1217

Drop-in Anchor E / ES Steel, zinc plated

Drop-in Anchor E / ES Steel, zinc plated

System Components. Grades. General Information. Installation Information Design Information Material Information Ordering Information

English translation prepared by CSTB - Original version in French language

ULTRAPLUS M12-M36. The undercut anchor for exceptionally high loads in cracked and non-cracked concrete also for shock and seismic loads.

PRODUCT DATA SHEET THROUGH BOLTS S-KA S-KAK S-KAH A4 S-KAH HCR S-KAR A2 HHA A2

AC100-PRO. AC100-PRO Vinylester 160ML AC100-PRO Vinylester 300ML AC100-PRO Vinylester 360ML AC100-PRO Vinylester 410ML AC100-PRO 160ML AC100-PRO 300ML

ULTRAPLUS M12-M36. The undercut anchor for exceptionally high loads in cracked and non-cracked concrete also for shock and seismic loads.

Declaration of Performance No1109-CPD-0080 According to the Regulation EU No 305/2011

EJOT Through Bolts. Premium-quality through bolts for fixing in cracked and non-cracked concrete.

HRD PLASTIC ANCHOR. Technical Datasheet Update: Dec-17

PF18 CHEMICAL ANCHOR CHEMICAL INJECTION SYSTEM

HRD-U 10 / - S 10 / -U 14 Frame anchor

DECLARATION OF PERFORMANCE

SIMPLY THE BEST HEAVY DUTY SELF-UNDERCUTTING ANCHOR IN THE WORLD

PRODUCT DATA SHEET SAFETY BOLT

HRD PLASTIC ANCHOR. Technical Datasheet Update: Aug-18

HLC. Hex head nut with pressed-on washer HLC-H. Bolt version with washer HLC-L. Torx round head HLC-SK. Torx Counter sunk head HLC-EC

HRD Frame anchor, Redundant fastening

Concrete screw BSZ Steel/steel zinc flake coated

European Technical Approval ETA-08/0058

Technical data No. 17/0001 of 25/04/2017

EJOT Concrete screws. ETA-approved concrete screws for cracked and non-cracked concrete

Intended uses of the construction product, in accordance with the applicable harmonized technical specification as foreseen by the manufacturer:

MKT Fixing. JAM The Professional Standard. Quality Management. Environmental Management. Energy Management

LEGACY REPORT ER-5608* Reissued February 1, Legacy report on the 1997 Uniform Building Code

Internal dry conditions Static or quasi-static loads Seismic actions for Performance Category C1 and C2 Fire exposure

Typical Applications. 1) Concrete Temperature 2) Cartridge Temperature must be min. +15 C. 3) Cartridge Temperature must be under +20 C.

High-performance anchoring adhesive. n Styrene-free n Low odour n Low wastage n No transportation restrictions

DECLARATION OF PERFORMANCE

Hilti HIT-RE 100 mortar with rebar (as anchor)

Hilti HIT-HY 270 mortar for masonry Ultimate performance hybrid mortar for all masonry materials

Designated according to Article 29 of Regulation (EU) No 305/2011 and member of EOTA (European Organisation for Technical Assessment)

English translation prepared by CSTB - Original version in French language PB-PRO & PB-SS-PRO

European Technical Assessment. ETA-17/0237 of 15/05/2017. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

Designated. according to. Article29 of. Regulation (EU) Nº 305/2011. English translation prepared by IETcc. Original version in Spanish language

DECLARATION OF PERFORMANCE

WARSAW ul. FILTROWA 1 phone: (48 22) , (48 22) fax: (48 22)

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

English translation prepared by CSTB - Original version in French language POWERS PB-PRO-S

English translation prepared by CSTB - Original version in French language. Throughbolt PTB-ETA7-PRO

HIT-HY 270 INJECTION MORTAR. Technical Datasheet Update: Jul-18

Declaration of Performance


European Technical Assessment. ETA-11/0336 of 17 July English translation prepared by DIBt - Original version in German language.

English translation prepared by CSTB - Original version in French language. Injection system Hilti HIT-RE 500 V3

Transcription:

Hilti Metal Expansion Anchor Product Information 2-4 Letter for Phase-in of 5-6 Technical Data (Anchor Fastening Technology Manual) 7-14 Test Reports as per BS5080 15-38 Country of Origin 39 Hilti Engineering Service 40 Make your submission simple! To download the most updated submission folders and technical manuals, visit http://www.hilti.com.hk/downloads Recycling one ton of paper saves 17 trees and 7000 gallons of water. Please consider your environmental responsibility before using the hard copy version! 1

DESIGNED TO OUTPERFORM THE PAST AND THE PRESENT. Designers and engineers asked for it, so Hilti delivered: introducing the next generation metal expansion anchor. is the successor of HST - the first metal expansion anchor ever to carry an approval for cracked concrete. is now suitable for an even wider range of applications and conditions for added reassurance on your daily designs. Higher load performance at the same embedment depth The new presents two embedment depths that make design more versatile. Significantly higher loads can be achieved at the same embedment depth and application on thinner slabs is approved. Hilti is the perfect design solution for all safety relevant application for non-cracked and cracked concrete under static, seismic and shock loading. Meets challenging design requirements with ease such as smallest edge and spacing distances in combination with highest resistance values, thanks to its optimized coating, ingenious sleeve geometry and premium bolt material. 6.7kN M12 NEW HST M12 Designed to perform. Performs to design. Recommended Tension Load * +67% # 4.2kN 4kN Design Flexibility Minimum edge distance, spacing and member thickness is allowed with an optimized coating throughout the anchor which reduces expansion forces. Optimized Performance Higher loads is achieved by ingenious sleeve geometry combined with its high tension resistances, provides an increased undercut percentage, which leads to crack retraction effect. Best shear resistance with no compromise on ductility with the premium bolt material and cold forming technology. Embedment Depth 0 70mm -20mm 50mm 70mm Standard Reduced Standard * Recommended load is based on cracked concrete C20/25, with overall factor of safety=3 # New M8 to M16 are approved with higher tension load of 33% to 67% increase, shear load up to 27% increase, compared to HST. Smaller edge and space distances with improved design and installation flexibility Extensive Concrete Grades Minimum edge and spacing distances are possible thanks to s optimizes coating throughout the anchor, which reduces expansion forces in the system. Hilti M12 Competitor Anchor M12 Due to the advanced sleeve design, application on concrete strength class range from C12/15 to C80/95 is now possible. No concrete splitting may occur when placed close to edge and another anchor. 110mm 110mm 55mm Concrete splitting 55mm 2

Anchor Systems Stud anchor Base materials Concrete (cracked) Concrete (uncracked) Applications Wide range of safety-relevant applications Structural steel, facade, mechanical equipment, racks, hand rails, etc. Approvals BZS/shock BZS D 08-602 ETA, Seismic ETA 98/0001 (ETAG 001-02, Option 1) Approvals and test reports may apply to selected products only. Please refer to the documents for details. Advantages Highest resistance for geometrically challenging requirements, e.g.reduced member thickness, shortest spacing and edge distances Design tension resistance increased by up to 66% compared to HST Minimum slab thickness: increased concrete strength class range from C12/15 to C80/95 Flexibility with two embedment depths included in the ETA These are abbreviated instructions which may vary according to the application. Always observe/follow the instructions accompanying the product or refer to Technical data www.hilti.com/techlib. Material composition Head configuration Type of fastening Approvals / test reports (Galvanized) Steel, zinc-plated (min. 5 μm); (Stainless steel) Steel, A4 (SS316) Externally threaded Pre-fastening, Through-fastening BZS/shock, ETA, Fire, Seismic Recommended load (kn), cracked concrete at 25N/mm², safety factor(g )=3 Model Size M8 M10 M12 M16 M20 M24 Tensile Load, Nrec 2.5 4.0 6.7 9.4 12.2 13.3 (Standard embedment) Shear Load, Vrec 3.6 7.9 11.8 18.4 28.0 31.3 -R Tensile Load, Nrec 2.5 4.0 6.7 9.4 12.2 13.3 (Standard embedment) Shear Load, Vrec 5.2 8.4 12.2 21.2 32.4 38.3 Remarks: 1) All the data applies to no edge distance, spacing and other influences 2) For detail design method and cracked concrete information, please refer to Fastening Technology Manual (Galvanized version min. 5 μm) Ordering designation 226 Anchor size Anchor length Drill bit diameter Drill hole depth at embed. 1 Drill hole depth at embed. 2 Max. fixture thickness at embed. 1 Max. fixture thickness at embed. 2 Base plate clearance hole Required tightening torque Sales pack quantity Item number M8x75 -/10 M8 75 mm 8 mm - 60 mm - 10 mm 9 mm 20 Nm 100 pc 2105888 M8x95 -/30 M8 95 mm 8 mm - 60 mm - 30 mm 9 mm 20 Nm 80 pc 2105889 M8x115 -/50 M8 115 mm 8 mm - 60 mm - 50 mm 9 mm 20 Nm 50 pc 2105890 1) M10x70 10/- M10 70mm 10 mm 53 mm 10 mm - 9 mm 20 Nm 50 pc 2113974 1) 1) This is a non-stock item. For detailed lead time information please contact your Hilti 3 representative. Hilti online: www.hilti.com.hk

Anchor Systems Ordering designation Anchor size Anchor length Drill bit diameter Drill hole depth at embed. 1 Drill hole depth at embed. 2 Max. fixture thickness at embed. 1 Max. fixture thickness at embed. 2 Base plate clearance hole Required tightening torque Sales pack quantity Item number M10x80 20/- M10 80mm 10 mm 53 mm - 20 mm - 9 mm 20 Nm 50 pc 2113975 1) M10x90 30/10 M10 90mm 10 mm 53 mm 73 mm 30 mm 10 mm 12 mm 45 Nm 50 pc 2105712 M10x110 50/30 M10 110mm 10 mm 53 mm 73 mm 50 mm 30 mm 12 mm 45 Nm 40 pc 2105714 M10x130 70/50 M10 130 mm 10 mm 53 mm 73 mm 70 mm 50 mm 12 mm 45 Nm 25 pc 2105715 1) M10x160 100/80 M10 160 mm 10 mm 53 mm 73 mm 100 mm 80 mm 12 mm 45 Nm 25 pc 2105716 1) M12x85 10/- M12 85mm 12 mm 68 mm - 10 mm - 14 mm 60 Nm 25 pc 2113978 1) M12x95 20/- M12 95mm 12 mm 68 mm - 20 mm - 14 mm 60 Nm 25 pc 2113979 1) M12x115 40/20 M12 115mm 12 mm 68 mm 88 mm 40 mm 20 mm 14 mm 60 Nm 25 pc 2105719 M12x145 70/50 M12 145mm 12 mm 68 mm 88 mm 70 mm 50 mm 14 mm 60 Nm 25 pc 2105851 M12x185 110/90 M12 185 mm 12 mm 68 mm 88 mm 110 mm 90 mm 14 mm 60 Nm 25 pc 2105853 1) M12x215 140/120 M12 215 mm 12 mm 68 mm 88 mm 140 mm 120 mm 14 mm 60 Nm 25 pc 2105854 M12x235 160/140 M12 235 mm 12 mm 68 mm 88 mm 160 mm 140 mm 14 mm 60 Nm 25 pc 2105855 1) M12x255 180/160 M12 255 mm 12 mm 68 mm 88 mm 180 mm 160 mm 14 mm 60 Nm 25 pc 2105856 1) M16x115 15/- M16 115mm 16 mm 86 mm 15 mm - 18 mm 110 Nm 12 pc 2114053 1) M16x145 45/25 M16 145 mm 16 mm 86 mm 106 mm 45 mm 25 mm 18 mm 110 Nm 12 pc 2105859 M16x170 70/50 M16 170 mm 16 mm 86 mm 106 mm 70 mm 50 mm 18 mm 110 Nm 12 pc 2105860 M16x220 120/100 M16 220 mm 16 mm 86 mm 106 mm 120 mm 100 mm 18 mm 110 Nm 12 pc 2105861 1) M16x260 160/140 M16 260 mm 16 mm 86 mm 106 mm 160 mm 140 mm 18 mm 110 Nm 12 pc 2105862 1) M20x170 -/30 M20 170 mm 20 mm - 140 mm - 30 mm 22 mm 240 Nm 5 pc 2105891 M20x200 -/60 M20 200 mm 20 mm - 140 mm - 60 mm 22 mm 240 Nm 5 pc 2105892 M20x260 -/120 M20 260 mm 20 mm - 140 mm - 120 mm 22 mm 240 Nm 5 pc 2105893 1) M24x200 -/30 M24 200 mm 24 mm - 170 mm - 30 mm 26 mm 300 Nm 5 pc 2105894 M24x230 -/60 M24 230 mm 24 mm - 170 mm - 60 mm 26 mm 300 Nm 5 pc 2105895 1) 1) This is a non-stock item. For detailed lead time information please contact your Hilti representative. -R (Stainless Steel version A4) 7 Ordering designation Anchor size Anchor length Drill bit diameter Drill hole depth at embed. 1 Drill hole depth at embed. 2 Max. fixture thickness at embed. 1 Max. fixture thickness at embed. 2 Base plate clearance hole Required tightening torque Sales pack quantity Item number -R M8x75 -/10 M8 75 mm 8 mm - 60 mm - 10 mm 9 mm 20 Nm 50 pc 2105896 -R M8x95 -/30 M8 95 mm 8 mm - 60 mm - 30 mm 9 mm 20 Nm 50 pc 2105897 -R M8x115 -/50 M8 115 mm 8 mm - 60 mm - 50 mm 9 mm 20 Nm 50 pc 2105898 -R M10x70 10/- M10 70mm 10 mm 53 mm - 10 mm - 12 mm 45 Nm 50 pc 2113976 1) -R M10x80 20/- M10 80mm 10 mm 53 mm - 20 mm - 12 mm 45 Nm 50 pc 2113977 -R M10x90 30/10 M10 90 mm 10 mm 53 mm 73 mm 30 mm 10 mm 12 mm 45 Nm 50 pc 2105864 -R M10x110 50/30 M10 110 mm 10 mm 53 mm 73 mm 50 mm 30 mm 12 mm 45 Nm 40 pc 2105866 -R M10x130 70/50 M10 130 mm 10 mm 53 mm 73 mm 70 mm 50 mm 12 mm 45 Nm 25 pc 2105867 -R M10x160 100/80 M10 160 mm 10 mm 53 mm 73 mm 100 mm 80 mm 12 mm 45 Nm 25 pc 2105868 -R M12x85 10/- M12 85mm 12 mm 68 mm - 10 mm - 14 mm 60 Nm 25 pc 2114051 1) -R M12x95 20/- M12 95mm 12 mm 68 mm - 20 mm - 14 mm 60 Nm 25 pc 2114052 -R M12x115 40/20 M12 115 mm 12 mm 68 mm 88 mm 40 mm 20 mm 14 mm 60 Nm 25 pc 2105870 -R M12x145 70/50 M12 145 mm 12 mm 68 mm 88 mm 70 mm 50 mm 14 mm 60 Nm 25 pc 2105872 -R M12x185 110/90 M12 185 mm 12 mm 68 mm 88 mm 110 mm 90 mm 14 mm 60 Nm 25 pc 2105874 -R M12x215 140/120 M12 215 mm 12 mm 68 mm 88 mm 140 mm 120 mm 14 mm 60 Nm 25 pc 2105875 -R M16x115 15/- M16 115mm 16 mm 86 mm - 15 mm - 18 mm 110 Nm 12 pc 2114057 1) -R M16x145 45/25 M16 145 mm 16 mm 86 mm 106 mm 45 mm 25 mm 18 mm 110 Nm 12 pc 2105877 -R M16x170 70/50 M16 170 mm 16 mm 86 mm 106 mm 70 mm 50 mm 18 mm 110 Nm 12 pc 2105878 -R M16x220 120/100 M16 220 mm 16 mm 86 mm 106 mm 120 mm 100 mm 18 mm 110 Nm 12 pc 2105879 -R M16x260 160/140 M16 260 mm 16 mm 86 mm 106 mm 160 mm 140 mm 18 mm 110 Nm 12 pc 2105880 -R M16x300 200/180 M16 300 mm 16 mm 86 mm 106 mm 200 mm 180 mm 18 mm 110 Nm 12 pc 2105881 -R M20X170 -/30 M20 170 mm 20 mm - 140 mm - 30 mm 22 mm 240 Nm 5 pc 2105899 -R M20X200 -/60 M20 200 mm 20 mm - 140 mm - 60 mm 22 mm 240 Nm 5 pc 2105900 -R M24X200 -/30 M24 200 mm 24 mm - 170 mm - 30 mm 26 mm 300 Nm 5 pc 2105901 -R M24X230 -/60 M24 230 mm 24 mm - 170 mm - 60 mm 26 mm 300 Nm 5 pc 2105902 1) This is a non-stock item. For detailed lead time information please contact your Hilti representative. 4 Customer Hotline: Hong Kong 8228 8118 Macau 00800 8228 8118 227

2 November 2015 Ref: 071/MA/FL/15 To Whom It May Concern RE: Upgrade of HST Stud Anchor We are pleased to inform you that stud anchor is phased-in as an upgraded version of HST. The new anchor series is of equivalent or better specifications than current HST anchor. You can see the equivalent items below. Nomenclature M10 x90 30/10 Anchor type Diameter Anchor length Fixture thickness 1 / 2 Head mark HST Head mark -R Stainless steel Item No. Description Head mark Galvanized carbon steel Anchor length (mm) HST(-R) Item No. Description Head mark Anchor length 2105888 M8x75 -/10 C 75 371581 HST M8X75/10 C 75 2105889 M8x95 -/30 E 95 295378 HST M8x95/30 E 95 2105890 M8x115 -/50 G 115 371583 HST M8X115/50 G 115 2105712 M10x90 30/10 E 90 371584 HST M10X90/10 E 90 2105714 M10x110 50/30 F 110 295367 HST M10x110/30 F 110 2105715 M10x130 70/50 H 130 371586 HST M10X130/50 H 130 2105716 M10x160 100/80 J 160 272727 HST M10x160/80 J 160 2105719 M12x115 40/20 G 115 371587 HST M12X115/20 G 115 2105851 M12x145 70/50 I 145 371588 HST M12X145/50 I 145 2105853 M12x185 110/90 L 185 371589 HST M12X185/90 L 185 2105854 M12x215 140/120 N 215 371590 HST M12X215/120 N 215 2105855 M12x235 160/140 P 235 371591 HST M12X235/140 P 235 2105856 M12x255 180/160 O 255 371592 HST M12X255/160 O 255 2105859 M16x145 45/25 I 145 371593 HST M16X140/25 I 140 2105860 M16x170 70/50 K 170 371594 HST M16X165/50 J 165 2105861 M16x220 120/100 O 220 371595 HST M16X215/100 N 215 2105862 M16x260 160/140 R 260 371596 HST M16X255/140 R 255 2105891 M20x170 -/30 K 170 371598 HST M20X170/30 K 170 2105892 M20x200 -/60 M 200 371599 HST M20X200/60 M 200 2105893 M20x260 -/120 R 260 274697 HST M20x260/120 R 260 2105894 M24x200 -/30 M 200 371601 HST M24X200/30 M 200 2105895 M24x230 -/60 P 230 371602 HST M24X230/60 P 230 2105896 -R M8x75 -/10 C 75 435447 HST-R M8x75/10 C 75 2105897 -R M8x95 -/30 E 95 435448 HST-R M8x95/30 E 95 2105898 -R M8x115 -/50 G 115 435449 HST-R M8x115/50 G 115 2105864 -R M10x90 30/10 E 90 435450 HST-R M10x90/10 E 90 2105866 -R M10x110 50/30 F 110 435451 HST-R M10x110/30 F 110 2105867 -R M10x130 70/50 H 130 435452 HST-R M10x130/50 H 130 2105868 -R M10x160 100/80 J 160 435453 HST-R M10x160/80 J 160 2105870 -R M12x115 40/20 G 115 435454 HST-R M12x115/20 G 115 2105872 -R M12x145 70/50 I 145 435455 HST-R M12x145/50 I 145 2105874 -R M12x185 110/90 L 185 435456 HST-R M12x185/90 L 185 5 Hilti (Hong Kong) Ltd. 701-704, 708B Tower A Manulife Financial Centre 223 Wai Yip Street Kwun Tong Kowloon Hong Kong P +852-8228 8118 I F +852-2954 1751 www.hilti.com.hk

2105875 -R M12x215 140/12 N 215 435457 HST-R M12x215/120 N 215 2105877 -R M16x145 45/25 I 145 376051 HST-R M16X140/25 I 140 2105878 -R M16x170 70/50 K 170 376052 HST-R M16X165/50 J 165 2105879 -R M16x220 120/10 O 220 376053 HST-R M16X215/100 N 215 2105880 -R M16x260 160/14 R 260 376054 HST-R M16X255/140 R 255 2105881 -R M16x300 200/18 S 300 376055 HST-R M16X295/180 S 295 2105899 -R M20x170 -/30 K 170 376056 HST-R M20X170/30 K 170 2105900 -R M20x200 -/60 M 200 376057 HST-R M20X200/60 M 200 - - - - 2101998 HST-R M20X215/82 N 215 2105901 -R M24x200 -/30 M 200 376058 HST-R M24X200/30 M 200 2105902 -R M24x230 -/60 P 230 376059 HST-R M24X230/60 P 230 The major differences between and HST are: 1. Load performance exhibits higher or equivalent load performance in terms of tension and shear loads, compared to HST. can be applied in any case to directly replace HST. Revision of calculation can be carried out by Hilti Profis Anchor software or as per Hilti anchor design manual. 2. Application range on concrete can be applied on concrete cube strength of 15N/mm 2 to 95N/mm 2, cracked or uncracked. 3. Edge and anchor spacing distance requirements requires a smaller or equivalent edge and anchor spacing distances (refer to Hilti anchor design manual). 4. Setting depths allows two options of embedment depths; HST allows single embedment depth only. 5. Drilling methods Three different drilling methods (as below) are approved to be used in system, while only hammer drilling can be used in HST system. i) Hammer drilling ii) Diamond coring iii) Hollow drill bit ( -Dustless solution) Other minor differences and detailed technical information can be referred to Hilti anchor design manual. Should you have any enquiry, please feel free our customer service hotline at 8228 8118. Yours faithfully, Fean Lee Product Manager Hilti (Hong Kong) Ltd. 6

7 Metal expansion anchor Metal expansion anchor Anchor version Benefits Carbon steel -R Stainless steel - highest resistance for reduced member thickness, short spacing and edge distances - increased undercut percentage in combination with optimized coating - suitable for non-cracked and cracked concrete C 12/15 to C 80/95 - highly reliable and safe anchor for structural seismic design with ETA C1/C2 approval - flexibility with two embedment depths included in the ETA - minimum edge and spacing distances reduced by compared to HST - design tension resistance increased by up to 66% compared to HST - product and length identification mark facilitates quality control and inspection Concrete (uncracked) Tensile zone Seismic ETA-C1/C2 Fire ETA European Technical Approval CE conformity PROFIS Anchor design Software Hammer drilled holes Diamond drilled holes Hollow drillbit drilling Approvals / certificates Description Authority / Laboratory No. / date of issue European technical approval a) DIBt, Berlin ETA-98/0001 / 2015-11-06 Fire test report DIBt, Berlin ETA-98/0001 / 2015-11-06 a) All data for in concrete strength class C20/25 to C50/60 given in this section according to ETA-98/0001, issue 2015-11-06. Data for other concrete strength classes according to Hilti Technical Data assessment. 118 01 / 2016 Metal expansion anchor Basic loading data (for a single anchor) Static and quasi-static resistence All data in this section applies to: For details see Simplified design method - Correct setting (See setting instruction) - No edge distance and spacing influence - Steel failure - Minimum base material thickness - Concrete C 20/25, fck,cube = 25 N/mm² Mean ultimate resistence Anchor size M8 M10 M12 M16 M20 M24 Eff. Anchorage depth hef [mm] 47 40 60 50 70 65 85 101 125 Non-cracked concrete Tensile NRu,m [kn] 15,9 17,0 26,6 23,7 33,2 35,1 52,5 68,1 79,7 -R [kn] 15,9 17,0 26,6 23,7 33,2 35,1 52,5 68,1 79,7 Shear VRu,m [kn] 14,5 23,0 24,8 35,7 37,2 57,2 58,1 88,1 98,7 -R [kn] 16,5 26,9 26,6 32,7 38,5 51,0 66,8 102,1 120,8 Cracked concrete Tensile NRu,m [kn] 10,0 12,1 15,9 16,9 26,6 25,0 37,5 48,5 53,1 -R [kn] 10,0 12,1 15,9 16,9 26,6 25,0 37,5 48,5 53,1 Shear VRu,m [kn] 14,5 23,0 24,8 35,7 37,2 57,2 58,1 88,1 98,7 -R [kn] 16,5 26,9 26,6 32,7 38,5 51,0 66,8 102,1 120,8 Characteristic resistence Anchor size M8 M10 M12 M16 M20 M24 Eff. Anchorage depth hef [mm] 47 40 60 50 70 65 85 101 125 Non-cracked concrete Tensile NRk [kn] 12,0 12,8 20,0 17,9 25,0 26,5 39,6 51,3 60,0 -R [kn] 12,0 12,8 20,0 17,9 25,0 26,5 39,6 51,3 60,0 Shear VRk [kn] 13,8 21,9 23,6 34,0 35,4 54,5 55,3 83,9 94,0 -R [kn] 15,7 25,6 25,3 31,1 36,7 48,6 63,6 97,2 115,0 Cracked concrete Tensile NRk [kn] 7,5 9,1 12,0 12,7 20,0 18,9 28,2 36,5 40,0 -R [kn] 7,5 9,1 12,0 12,7 20,0 18,9 28,2 36,5 40,0 Shear VRk [kn] 13,8 21,9 23,6 34,0 35,4 54,5 55,3 83,9 94,0 -R [kn] 15,7 24,3 25,3 31,1 36,7 48,6 63,6 97,2 115,0 01 / 2016 119 B

8 Metal expansion anchor Design resistence Anchor size M8 M10 M12 M16 M20 M24 Eff. Anchorage depth hef [mm] 47 40 60 50 70 65 85 101 125 Non-cracked concrete Tensile NRd [kn] 8,0 8,5 13,3 11,9 16,7 17,6 26,4 34,2 40,0 -R [kn] 8,0 8,5 13,3 11,9 16,7 17,6 26,4 34,2 40,0 Shear VRd [kn] 11,0 17,5 18,9 27,2 28,3 43,6 44,2 67,1 62,7 -R [kn] 12,6 20,5 20,2 24,9 29,4 38,9 50,9 77,8 88,5 Cracked concrete Tensile NRd [kn] 5,0 6,1 8,0 8,5 13,3 12,6 18,8 24,4 26,7 -R [kn] 5,0 6,1 8,0 8,5 13,3 12,6 18,8 24,4 26,7 Shear VRd [kn] 11,0 16,2 18,9 23,6 28,3 42,9 44,2 67,1 62,7 -R [kn] 12,6 16,2 20,2 23,6 29,4 38,9 50,9 77,8 83,9 Recommended loads Anchor size M8 M10 M12 M16 M20 M24 Eff. Anchorage depth hef [mm] 47 40 60 50 70 65 85 101 125 Non-cracked concrete Tensile Nrec a) [kn] 4,0 4,3 6,7 6,0 8,3 8,8 13,2 17,1 20,0 -R [kn] 4,0 4,3 6,7 6,0 8,3 8,8 13,2 17,1 20,0 Shear Vrec a) [kn] 4,6 7,3 7,9 11,3 11,8 18,2 18,4 28,0 31,3 -R [kn] 5,2 8,5 8,4 10,4 12,2 16,2 21,2 32,4 38,3 Cracked concrete Tensile Nrec a) [kn] 2,5 3,0 4,0 4,2 6,7 6,3 9,4 12,2 13,3 -R [kn] 2,5 3,0 4,0 4,2 6,7 6,3 9,4 12,2 13,3 Shear Vrec a) [kn] 4,6 7,3 7,9 11,3 11,8 18,2 18,4 28,0 31,3 -R [kn] 5,2 8,1 8,4 10,4 12,2 16,2 21,2 32,4 38,3 a) With overall global safety factor = 3. The recommended loads vary according to the safety factor requirements from national regulations. 120 01 / 2016 Metal expansion anchor Materials and dimensions Mechanical properties Anchor size M8 M10 M12 M16 M20 M24 Nominal tensile strength fuk,thread Yield strength fyk,thread Stressed cross-section As Moment of resistance W Char. bending resistance M 0 Rk,s [N/mm²] 800 800 800 720 700 530 -R [N/mm²] 720 710 710 650 650 650 [N/mm²] 640 640 640 576 560 450 -R [N/mm²] 576 568 568 520 520 500 [mm²] 36,6 58,0 84,3 157 245 353 [mm³] 31,2 62,3 109 277 541 935 [Nm] 30 60 105 240 457 595 -R [Nm] 27 53 93 216 425 730 Material quality Part Material Bolt Carbon steel, galvanized to min. 5 μm -R A4 Stainless steel Anchor dimensions Setting instructions Installation equipment Anchor size M8 M10 M12 M16 M20 M24 Rotary hammer TE2(-A) TE30(-A) TE40 TE70 Diamond coring tool DD-30W, DD-EC1 Setting tool Setting tool HS-SC - Hollow drill bit - TE-CD, TE-YD Other tools hammer, torque wrench, blow out pump 01 / 2016 121 B

9 Metal expansion anchor Setting instruction for M8 Setting instruction for M10 122 4 4 01 / 2016 Metal expansion anchor Setting instruction for M12 4 Setting instruction for M16 4 01 / 2016 123 B

10 Metal expansion anchor Setting instruction for M20 Setting instruction for M24 For detailed informations on installation see instruction for use given with the package of the product. 124 01 / 2016 Metal expansion anchor Setting details Anchor size M8 M10 M12 M16 M20 M24 Nominal diameter of drill bit [mm] 8 10 12 16 20 24 Cutting diameter of drill bit [mm] 8,45 10,45 12,5 16,5 20,55 24,55 Nominal anchorage depth Effective anchorage depth Depth of drill hole (hammer drilled holes) Depth of drill hole (diamond drilled holes) Diameter of clearance hole in the fixture [mm] - 48 60 78 - - [mm] 54 68 80 98 116 143 [mm] - 40 50 65 - - [mm] 47 60 70 85 101 125 [mm] - 53 68 86 - - [mm] 59 73 88 106 124 151 [mm] - 58 70 88 - - [mm] 64 78 90 108 - - [mm] 9 12 14 18 22 26 Torque moment [Nm] 20 45 60 110 180 300 Width across [mm] 13 17 19 24 30 36 a)only for C20/25 to C50/60 b)for C12/15 to C80/95, for concrete strength class C12/15, C16/20 and C55/67 to C80/95 Hilti Technical Data. Setting details: depth of drill hole h1 and effective anchorage depth hef hmin h1 hnom tfix hef 01 / 2016 125 B

11 Metal expansion anchor Setting parameters for M8 and M10 Anchor Size M8 M10 Concrete class C55/67 to C80/95 b) C20/25 to C50/60 a) C16/20 b) C12/15 b) C20/25 to C50/60 a) C55/67 to C80/95 b) C12/15 b) C16/20 b) Effective anchorage depth Minimum base material thickness [mm] 47 47 40 60 60 [mm] 80 100 100 80 100 120 120 Minimum spacing in noncracked concrete [mm] 35 35 35 50 40 40 70 [mm] 55 50 65 95 100 60 90 Minimum spacing in cracked concrete [mm] 35 35 35 40 40 40 45 [mm] 50 50 55 90 100 55 85 Minimum edge distance in non-cracked concrete [mm] 40 40 50 50 60 50 80 [mm] 60 50 80 190 90 90 120 Minimum edge distance in cracked concrete [mm] 40 40 40 45 60 45 70 [mm] 50 50 75 180 90 80 120 Critical spacing for splitting failure and concrete cone failure [mm] 141 141 188 168 180 180 240 [mm] 141 141 120 180 180 Critical edge distance for splitting failure and concrete cone failure [mm] 71 71 94 84 90 90 120 [mm] 71 71 60 90 90 a) For concrete classes C20/25 to C50/60 data covered by ETA-98/0001 issue 2015-11-06. b) Data covered by Hilti Technical Data. For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be reduced. 126 01 / 2016 Metal expansion anchor Setting parameters for M12 and M16 Anchor size M12 M16 Concrete class C20/25 to C50/60 a) C55/67 to C80/95 b) C12/15 b) C16/20 b) C20/25 to C50/60 a) C55/67 to C80/95 b) C12/15 b) C16/20 b) Effective anchorage depth [mm] 50 70 70 65 85 85 Minimum base material thickness [mm] 100 120 140 140 120 140 160 160 Minimum spacing in noncracked concrete [mm] 55 50 60 110 75 80 65 90 [mm] 110 100 70 140 140 130 95 145 Minimum spacing in cracked concrete [mm] 50 50 50 80 65 80 65 70 [mm] 105 90 70 120 130 130 95 125 Minimum edge distance in non-cracked concrete [mm] 60 60 55 90 65 65 65 110 [mm] 210 120 110 190 240 180 150 170 Minimum edge distance in cracked concrete [mm] 55 60 55 80 65 65 65 90 [mm] 210 120 110 170 240 180 150 165 Critical spacing for splitting failure and concrete cone failure [mm] 180 280 208 340 210 255 [mm] 150 210 195 255 Critical edge distance for splitting failure and concrete cone failure [mm] 90 140 104 170 105 128 [mm] 75 105 98 128 a) For concrete classes from C20/25 to C50/60 data covered by ETA-98/0001 issue 2015-11-06. b) Data covered by Hilti Technical Data. For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be reduced. 01 / 2016 127 B

12 Metal expansion anchor Setting parameters for M20 and M24 Anchor size M20 M24 Concrete class C20/25 to C50/60 a) C55/67 to C80/95 b) C12/15 b) C16/20 b) C20/25 to C50/60 a) C55/67 to C80/95 b) C12/15 b) C16/20 b) Effective anchorage depth [mm] 101 101 125 125 Minimum base material thickness [mm] 160 200 200 250 250 Minimum spacing in non-cracked concrete Minimum spacing in cracked concrete Minimum edge distance in non-cracked concrete Minimum edge distance in cracked concrete -R/ -R/ -R/ -R/ Critical spacing for splitting failure and concrete cone failure Critical edge distance for splitting failure and concrete cone failure [mm] 120 90 90 125 180 [mm] 180 130 165 255 375 [mm] 120 90 90 125 180 [mm] 180 130 165 205 375 [mm] 120 90 90 125 140 [mm] 180 130 140 180 325 [mm] 120 90 90 125 140 [mm] 180 130 140 130 325 [mm] 120 80 120 170 260 [mm] 180 180 270 295 400 [mm] 120 80 120 150 260 [mm] 180 180 270 235 400 [mm] 120 80 100 125 230 [mm] 180 180 240 240 295 [mm] 120 80 100 125 230 [mm] 180 180 240 140 295 [mm] 384 404 375 500 [mm] 303 303 375 375 [mm] 192 202 188 250 [mm] 152 152 188 188 a) For concrete classes from C20/25 to C50/60 data covered by ETA-98/0001 issue 2015-11-06. b) Data covered by Hilti Technical Data. For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be reduced. 128 01 / 2016 Metal expansion anchor Simplified design method Simplified version of the design method according to ETAG 001, Annex C respectively CEN TS 1992-4-4. Design resistance according to the data given in ETA-98/0001, issue 2015-11-06 for concrete classes C20/25 to C50/60. In case of concrete classes C12/15, C16/20 and C55/67 to C80/95 the concrete cone failure mode can also be assumed according to CEN TS 1992-4-4 based on the Expert Report. Influence of concrete strength Influence of edge distance Influence of spacing Static/quasi-static loading Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two anchors or more than one edge. The influencing factors must then be considered for each edge distance and spacing. The calculated design loads are then on the save side: They will be lower than the exact values according ETAG 001, Annex C. To avoid this, it is recommended to use the anchor design software PROFIS anchor) The design method is based on the following simplification: No different loads are acting on individual anchors (no eccentricity) The values are valid for one anchor. For more complex fastening applications please use the anchor design software PROFIS Anchor. Tension loading Basic design tensile resistance Design steel resistance NRd,s Anchor size M8 M10 M12 M16 M20 M24 NRd,s /-BW [kn] 14,1 23,2 32,2 54,3 88,7 90,1 -R/-R-BW [kn] 12,6 20,5 30,4 49,6 82,7 100,0 1.4 Design pull-out resistance NRd,p = N 0 Rd,p fb Anchor size M8 M10 M12 M16 M20 M24 Non cracked concrete N 0 Rd,p [kn] 8,0 13,3 16,7 - - 40,0 -R [kn] 8,0 13,3 16,7 - - 40,0 Cracked concrete N 0 Rd,p [kn] 5,0 8,0 13,3 - - 26,7 -R [kn] 5,0 8,0 13,3 - - 26,7 1.5 01 / 2016 129 B

13 Metal expansion anchor Design concrete cone resistance NRd,sp = N 0 Rd,c fb f1,n f2,n f3,n fre,n Design splitting resistance a) NRd,sp = N 0 Rd,c fb f1,sp f2,sp f3,sp f h,sp fre,n Anchor size M8 M10 M12 M16 M20 M24 Effective anchorage depth hef 47 40 60 50 70 65 85 101 125 Non cracked concrete N 0 Rd,c [kn] 10,8 8,5 15,6 11,9 19,7 17,6 26,4 34,2 47,1 -R [kn] 10,8 8,5 15,6 11,9 19,7 17,6 26,4 34,2 47,1 Cracked concrete [kn] N 0 Rd,c 7,7 6,1 11,2 8,5 14,1 12,6 18,8 24,4 33,5 -R [kn] 7,7 6,1 11,2 8,5 14,1 12,6 18,8 24,4 33,5 a) Splitting resistance must only be considered for non-cracked concrete Influencing factors Influence of concrete strength Hilti data Data according to ETA-98/0001 Hilti Data Concrete strength designation (ENV 206) fb,c = (fck,cube/25n/mm²) 1/2 a) 0,77 0,89 1,00 1,10 1,22 1,34 1,41 1,48 1,55 1,64 1,73 1,84 1,95 For M8, M10, M12 and M16 fb,p 0,68 0,85 1,00 1,10 1,22 1,34 1,41 1,48 1,55 1,55 1,55 1,55 1,55 For M20 and M24 fb,p 0,68 0,85 1,00 1,10 1,22 1,34 1,41 1,48 1,55 1,60 1,66 1,72 1,78 a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length Influence of edge distance a) c/ccr,n c/ccr,sp 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 f1,n = f1,sp = 0,73 0,76 0,79 0,82 0,85 0,88 0,91 0,94 0,97 1,00 f2,n = f2,sp = 0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1,00 a) The edge distance shall not be smaller than the minimum edge distance cmin given in the table with the setting details. These influencing factors must be considered for every edge distance. Influence of anchor spacing a) s/scr,n s/scr,sp 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 f3,n = 0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95 1,00 f3,sp = a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the setting details. This influencing factor must be considered for every anchor spacing. 130 01 / 2016 C12/15 C16/20 C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60 C55/67 C60/75 C70/85 C80/95 1.5 Metal expansion anchor Influence of base material thickness h/hef 2,0 2,2 2,4 2,6 2,8 3,0 3,2 3,4 3,6 1,00 1,07 1,13 1,19 1,25 1,31 1,37 1,42 1,48 1,50 Influence of reinforcement Anchor size M8 M10 M12 M16 M20 M24 0,74 a) 0,70 a) 0,80 a) 0,75 a) 0,85 a) 0,83 a) 0,93 a) 1,00 1,00 Shear loading Basic design shear resistance Design steel resistance VRd,s Anchor size M8 M10 M12 M16 M20 M24 Effective anchorage depth hef 47 40 60 50 70 65 85 101 125 VRd,s [kn] 11,0 17,5 18,9 27,2 28,3 43,6 44,2 67,1 62,7 -R [kn] 12,6 20,5 20,2 24,9 29,4 38,9 50,9 77,8 88,5 1.25 Anchor size M8 M10 M12 M16 M20 M24 k-factor for C20/25 to C80/95 2,6 2,7 2,8 3,4 3,2 2,5 k-factor for C12/15 1 2 2 2 2 2 a) NRd,c: Design concrete cone resistance 1 1 Anchor size M8 M10 M12 M16 M20 M24 Effective anchorage depth hef 47 40 60 50 70 65 85 101 125 Non-cracked concrete V [kn] 0 Rd,c -R [kn] Cracked concrete 5,9 8,5 8,6 11,6 11,7 18,8 18,9 27,3 37,1 V 0 Rd,c [kn] -R [kn] a) For anchor groups only the anchors close to the edge must be considered. 4,2 6,0 6,1 8,2 8,3 13,3 13,4 19,3 26,3 01 / 2016 131 B

14 Metal expansion anchor Influencing factors Hilti data Data according to ETA-98/0001 Hilti Data Concrete strength designation (ENV 206) fb,c = (fck,cube/25n/mm²) 1/2 a) 0,77 0,89 1,00 1,10 1,22 1,34 1,41 1,48 1,55 1,64 1,73 1,84 1,95 a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length Influence of angle between load applied and the direction perpendicular to the free edge Angle ß 0 10 20 30 40 50 60 70 80 90 1,00 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50 Influence of base material thickness h/c 0,15 0,3 0,45 0,6 0,75 0,9 1,05 1,2 1,35 f h = 0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00 c/hef Single anchor Group of two anchors s/hef 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25 0,50 0,35 0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,75 0,65 0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 1,00 1,00 0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,25 1,40 0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,50 1,84 1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,75 2,32 1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,00 2,83 1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,25 3,38 1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38 2,50 3,95 2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95 2,75 4,56 2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56 3,00 5,20 2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20 3,25 5,86 3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86 3,50 6,55 3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55 3,75 7,26 3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26 4,00 8,00 4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75 4,25 8,76 4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25 4,50 9,55 5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75 4,75 10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26 5,00 11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78 5,25 12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31 5,50 12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85 a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the minimum edge distance cmin. 132 01 / 2016 C12/15 C16/20 C 20/25 C 25/30 C 30/37 C 35/45 C 40/50 C 45/55 C 50/60 C55/67 C60/75 C70/85 C80/95 Metal expansion anchor Influence of embedment depth Anchor size M8 M10 M12 M16 M20 M24 f hef = 0,98 0,51 1,01 0,55 0,97 0,53 0,83 0,76 0,80 Influence of edge distance a) c/d 4 6 8 10 15 20 30 40 fc = (d / c) 0,19 0,77 0,71 0,67 0,65 0,60 0,57 0,52 0,50 a) The edge distance shall not be smaller than the minimum edge distance cmin. Combined tension and shear loading For combined tension and shear loading see section Anchor Design. 01 / 2016 133 B

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

Attn: To whom it may concern 2 November 2015 Ref: 072/MA/FL/15 Subject: Stud Anchor Country of Origin Dear Sir/ Madam, Please find the information of Hilti Stud Anchor. Brand Name : Hilti Model Name : Hilti Stud Anchor Supplier : Hilti (Hong Kong) Ltd Address of Supplier : 701-704A & 708A&B, 7/F, Tower A, Manulife Financial Centre, 223 Wai Yip Street, Kwun Tong, Hong Kong Country of Origin : Liechtenstein Name of Factory : Hilti Aktiengesellschaft Address of Factory : Hilti AG, Feldkircherstrasse, FL-9494 Schaan, Liechtenstein Should you have any enquiry, please feel free our customer service hotline at 8228 8118. Yours faithfully, Fean Lee Product Manager Hilti (Hong Kong) Ltd. 39 Hilti (Hong Kong) Ltd. 701-704A, 708A&B Tower A Manulife Financial Centre 223 Wai Yip Street Kwun Tong Kowloon Hong Kong P +852-8228 8118 I F +852-2954 1751 www.hilti.com.hk

YOUR HASSLE-FREE SERVICE PARTNER THROUGHOUT YOUR PROJECT. Design and Specification Documentation Project Submission Site Execution Design at a Click Hilti PROFIS Anchor software makes it easy to identify the optimal Hilti anchor for all your anchor applications. When you design with PROFIS Anchor, you get the added reassurance that your designs meet codal provisions of the European Technical Approval Guidelines (ETAG) with just one click! Dependable Documents and Approvals Hilti anchors are designed and tested under European Technical Approvals (ETA) for cracked and uncracked concrete, as well as dynamic loading applications e.g shock, seismic, etc. You are well supported with comprehensive technical information and test reports for your project approval at Buildings Department, Housing Authority, Architectural Services Department, etc. Engineering Support on Call Hilti engineers are available to assist you in your design and project submission for approvals, at no additional cost. To contractors, we offer free on-site installation card training with certificate. You can access our technical support 24/7; contact our Design Engineers, Engineering Hotline 2773 4731, or visit hilti.com.hk. Testing Service for Quality Assurance Independent Hilti Testing Laboratory is HOKLAS accredited for onsite anchor loading testing complying with BS5080. Assuring your anchor design is properly and safely implemented at the job site, when workmanship is verified. 40 6 7