OREGON HEALTH & SCIENCE UNIVERSITY RADIATION SAFETY OPERATING PROCEDURE 1801 RADIOACTIVE WASTE HANDLING & STORAGE

Similar documents
2/07. PROCEDURE for DISPOSAL of RADIOACTIVE MATERIALS

PROGRAM FOR THE MANAGEMENT AND DISPOSAL OF RADIOACTIVE WASTE

Date June 2, 2006 Page 1 of 5. Approved By

By: Georgia Institute of Technology

University of Richmond Radiation Safety Manual

Radiation Safety Manual

Laboratory Safety Reminders

RADIOISOTOPE ACQUISITION AND DISPOSITION

Radiation Safety at the University of Vermont

Radioactive Material User Annual Refresher Training. Created by SU Environmental Health & Safety Services

WVU IACUC SOP: Radioactive Materials Used in Animal Studies

The University of Texas Health Science Center at San Antonio Environmental Health & Safety Department Radiation Safety Division

OREGON HEALTH & SCIENCE UNIVERSITY RADIATION SAFETY OPERATING PROCEDURE 1101 LABORATORY RADIATION SURVEY

THE UNIVERSITY OF TULSA RADIATION SAFETY PROGRAM. Table of Contents

LABORATORY WASTE DISPOSAL GUIDE

Swette Center for Environmental Biotechnology Radiation Safety Policy

Medical, Pathological and Low-level Radioactive Waste Management Plan for Incinerator Revised 3-08

MIXED WASTE MANAGEMENT PROGRAM. UNIVERSITY RISK MANAGEMENT Radiation Safety 19 Hagood Avenue, Suite 301 Charleston SC

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

RADIOACTIVE MATERIALS SAFETY REFRESHER EXAM

Radiation Safety Program Hunter College of the City University of New York

P780 Annual Refresher Radiation Safety Training. P780 Radiation Safety

Standard Operating Procedure. Handling of Radioactive Material. PC-SOP-IM-005-v02

The use of radionuclides in an academic and. Waste Management by a One-Man Band. Managing a University and Medical LLRW Program

THE UNIVERSITY OF CHICAGO APPLICATION FOR NON-HUMAN USE OF RADIOACTIVE MATERIAL

8.0 Radioactive Waste

RADIOACTIVE WASTE MANAGEMENT PLAN

Performance-Based Inspection Field Guide

EHS Assist Radioactive Material User Instructions. Link to EHS Assist from the EHS homepage

WHO NEEDS TO KNOW THIS PROGRAM All NYU employees that generate, handle or transport RMW should be familiar with this written program.

Consignment of Waste to the Disposal of Hazardous Waste Service

Biological and Regulated Medical Waste Plan

UNIVERSITY OF RICHMOND REGULATED MEDICAL WASTE MANAGEMENT GUIDELINES

Appendix J. University of Alabama at Birmingham Medical Waste Management Plan

BALL STATE UNIVERSITY RADIATION PROTECTION PROCEDURES* USER S GUIDE

SURVEY GUIDE FOR UNSEALED RADIOACTIVE MATERIAL

This is Chapter 6, part-two of the Radiation Safety Short Course: Radioisotope Laboratory Techniques. In this section we will review what Radiation

Delaware State University

University of Aberdeen

EMORY UNIVERSITY RADIOISOTOPE COMMITTEE II APPLICATION FOR NON-HUMAN RADIOACTIVE MATERIAL USE

Waste Disposal Policies and Procedures

RESPONSIBILITIES Each person who works with unsealed or dispersible radioactive materials is responsible for:

University Health Services Health and Safety

UC IRVINE RADIATION SAFETY FACTSHEET

THE RICHARD STOCKTON COLLEGE OF NEW JERSEY. Natural Sciences and Mathematics Department. Radiation Safety Program

University of Maryland Baltimore. Radiation Safety Procedure

DEPARTMENT OF BIOLOGICAL SCIENCES MEDICAL/BIOHAZARDOUS WASTE DISPOSAL AUTOCLAVE TRAINING

RADIATION SAFETY MANUAL

Radioactive Waste Radiation Safety Orientation Open Source Booklet 7 (June 1, 2018)

Waste Management. School Safety Advisor School of Chemistry UCD

Hazardous Materials Management Policies and Procedures

Radioactive Material Safety Manual

FACT SHEET : Using Autoclaves Safely

RADIOISOTOPE USE AND SAFETY MANUAL

California Polytechnic State University San Luis Obispo. Radiation Safety Manual

Radioactive Waste Disposal

Radiation Safety Manual

RADIONUCLIDE USERS ANNUAL REFRESHER TRAINING GUIDE RADIATION SAFETY SERVICE

MATERIAL SAFETY DATA SHEET SECTION 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION SECTION 2. COMPOSITION, INFORMATION ON INGREDIENTS

CLEMSON UNIVERSITY LAB CLOSE-OUT POLICY/PROCEDURES FOR HAZARDOUS SUBSTANCES, EQUIPMENT, SUPPLIES, ETC.

LABORATORY WASTE MANAGEMENT PROGRAMMES

Biomedical Waste Management Guide

THE SAFE DISPOSAL OF CLINICAL/DOMESTIC WASTE

Virginia Commonwealth University RADIATION SAFETY GUIDE

Environmental Health and Safety Equipment Release Form

Guidelines for the Use of Cytotoxic or Chemotherapeutic Drugs

So Now You Are The RSO Radiation Safety Programs. Norman W. Henry III, MS,CIH SHBP (Safety and Health By Protection) comcast.

Laboratory Close-Out Guidelines

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY

Policy & Procedure Manual

Radiation Safety Procedure. Contamination Monitoring

Waste Disposal Procedures (EHS Program 5.2)

Radiation Safety Manual

Radiation Safety Operating Procedure. Shipping and Transporting

Dartmouth College. Institutional Biosafety Committee. Biohazardous Waste Disposal Guide IBC Approved: 10/3/18

Dartmouth College. Institutional Biosafety Committee. Biohazardous Waste Disposal Guide IBC Approved: 4/5/17

APPENDIX B INSTRUCTIONS AND SAMPLE APPLICATION FORMS FOR AUTHORIZATION

Guidelines for Laboratory Closure

Safe Operating Procedure

DISPOSAL OF HAZARDOUS WASTE, CHEMICAL WASTE AND UNUSED CHEMICALS

Philip E. Hamrick, Ph.D. National Institute of Environmental Health Sciences Research Triangle Park, NC

Employee Environmental, Health & Safety Manual. INFECTIOUS WASTE MANAGEMENT PROGRAM Latest Revision: 05/27/08

OFFICE OF RESEARCH SAFETY RS104 Lab Closeout Policy

GUIDELINES FOR SHIPPING NONPATHOGENIC BIOLOGICAL CULTURES AND NON-INFECTIOUS BIOLOGICAL MATERIALS

Health Sciences Campus Biomedical Waste Management Standard Operating Procedure (SOP)

Biosafety Checklist. 07-BiosafetyChecklist-LTC-SOP-v2.0-17Feb of 6

RADIATION SAFETY MANUAL

Radiological Safety Manual

For ethidium bromide waste that is generated at Harvard, each waste stream is to be managed or accumulated as described below.

MATERIAL SAFETY DATA SHEET SECTION 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION SECTION 2. COMPOSITION, INFORMATION ON INGREDIENTS

University Health Services Health and Safety REGULATIONS FOR AUTOCLAVE USE, MAINTENANCE AND RECORDKEEPING

TABLE OF CONTENTS Radiation Safety Handbook

Radiation Safety Manual. for. Bowling Green State University

LSU Inter-Institutional Biological and Recombinant DNA Safety Committee (IBRDSC)

Thank you for joining me for Chapter 6, of the Radiation Safety Short Course, part one of Radioisotope Laboratory Techniques.

You are required to complete this course with a passing score of 85% or higher if you:

UNIVERSITY OF TOLEDO

CHAPTER 32 IONIZING RADIATION

Transcription:

OREGON HEALTH & SCIENCE UNIVERSITY RADIATION SAFETY OPERATING PROCEDURE 1801 RADIOACTIVE WASTE HANDLING & STORAGE I. PURPOSE: To describe the manner in which radioactive waste shall be stored and/or disposed of by research laboratories at OHSU. II. DISCUSSION: In order to keep exposure to radiation As Low As Reasonably Achievable (ALARA) in the research laboratories at OHSU, radioactive waste shall be handled according to the following procedure. Proper storage and disposal methods, and accurate record keeping for radioactive wastes are essential to the radiation safety program. In order to reduce waste build-up in the lab and to stay within individual license limits, radioactive waste should be picked up or otherwise disposed of periodically. Radioactive waste disposal is provided by the RSO on a fee-for-service basis. Requests for radioactive waste pick-up may be made by telephone to the Radiation Safety Office at Ext. 4-2578. III. EQUIPMENT A. Protective Clothing 1. Disposable latex or vinyl exam gloves 2. Lab Coat 3. Eye protection when necessary 4. Radiation labels/tape B. Provided by RSO as needed by lab: 1. Cardboard box (es) (2 cubic ft) with yellow and clear liners or 55 gallon drums with clear liners for high-volume users. Both containers can have absorbent material added by RSO for LSC waste. 2. Approved liquid absorbent (Superfine) and 1 gallon plastic container(s) for absorbed aqueous waste. IV. PRECAUTIONS: A. Minimize the handling of radioactive material. Always wear protective clothing and gloves when handling radioactive materials. B. Ensure that radioactive waste containers are conspicuously marked with radiation labels and placed in an area where they will not be mistaken as regular trash. Radioactive Waste Handling & Storage (RSOP 1801) 3/11/2003 1

C. Prior to generating mixed radioactive waste with biological, infectious, or chemical waste, contact the RSO for information on disposal. D. Dispose of sharp objects, glass pipettes and needles in a sharps container before placing in the radioactive dry waste. V. DRY RADIOACTIVE WASTE NOTES: Radioactive waste must not be disposed of in the regular trash. The outside of all containers with radioactive dry waste must be clearly labeled with ARadioactive Materials@ tape or labels. A. Storage in the lab 1. Radioactive waste that does not require shielding shall be kept in a 2 cubic foot box or other sturdy container fitted with a clear plastic liner over a yellow plastic liner. 2. Any radioactive waste that requires shielding (i.e. plexiglass for 32 P, or lead for 51 Cr) shall be stored within a clear plastic liner over a yellow plastic liner within the appropriate shielding. 3. Radioactive waste should be stored away from regular trash. 4. Biological or infectious radioactive waste must be stored in red biohazard bags marked with ARadioactive Materials@ tape. Biological or infectious radioactive waste must be deactivated before being discarded to the radioactive waste container, or decayed to background prior to incineration. B. Storage for decay 1. Laboratory Decay of Radioactive Waste: a. Only radioactive waste with half-lives < 90 days may be stored for decay in the laboratory. Radionuclides with half-lives > 90 days must be given to RSO for pick up. Each radionuclide must have its own collection container. Waste that is being held for decay must be stored for a minimum of 10 half-lives (5 halflives for I-125) and be at background before disposal to regular trash. b. A survey instrument appropriate for the radiation being measured must be used. It should be set on the most sensitive scale. c. For low energy beta emitters, hold detector at the surface of the bag at several points, including the bottom. Then open the bag and survey the inside of the bag without actually touching the detector to the waste. d. For high energy beta and gamma emitters, survey in the same manner, but there is no need to open the bag. e. The results of this survey must be documented and retained as records of decayed waste disposal. A sample record sheet is included with this procedure. f. All radiation labels must be removed or obliterated prior to disposal in the regular trash. It is recommended that this is done before storing waste for decay. Radioactive Waste Handling & Storage (RSOP 1801) 3/11/2003 2

C. Record Keeping 1. Disposal of radioactive waste must be recorded. Information that must be included is: radionuclide, activity, date, and initials of person discarding the waste. The waste log must be kept on or near the waste container. 2. For decay record keeping see B.1.e above. VI. LIQUID SCINTILLATION WASTES NOTES: The average concentration of LSC waste for RSO pick-up must be less than or equal to 0.05 µci/ml. All containers and storage areas with radioactive liquid waste must be clearly labeled with ARadioactive Materials@ tape or labels. A. Non-Hazardous, Biodegradable Liquid Scintillation Cocktail 1. Before drain disposing of liquid waste, determine the activity using RSOP 1803. Water must be running before, during, and after drain disposal. 2. Non-hazardous biodegradable liquid scintillation cocktail that is dispersible in water may be disposed of down the drain or picked up by the RSO. 3. After LSC vials have been emptied, they must be triple-rinsed with water and may be disposed of in regular trash if at background levels. 4. Jugs filled with LSC cocktail must be stored in unbreakable secondary containers. The container must be large enough to hold the entire contents of the jug. Filled vials may be stored in their original trays or in containers provided by the RSO. B. Hazardous Liquid Scintillation Cocktail 1. Toluene, xylene or other hazardous or non-biodegradable liquid scintillation cocktails must be disposed of through the RSO. 2. Jugs must be stored in unbreakable secondary containers and in appropriate chemical storage areas. 3. Filled vials must be stored in containers provided by the RSO and must be picked up for disposal by the RSO. C. Record Keeping The activity of all liquid scintillation waste that is disposed of via the RSO or the sanitary sewer must be accurate. See RSOP 1803 for drain disposal activity documentation. Keep a log sheet on the LSC container to record radionuclides, total activity, total volume in milliliters and initials of user. VII. LIQUID WASTE Aqueous radioactive waste may only be absorbed in one-gallon plastic containers provided by the RSO. See RSOP 1804 - Absorbing Aqueous Radioactive Wastes. Absorbed liquid wastes are picked up by the RSO. Aqueous radioactive waste may also be disposed of down the drain. See RSOP 1803. Radioactive Waste Handling & Storage (RSOP 1801) 3/11/2003 3

VIII. ANIMAL WASTES Radioactivity levels in animal wastes must be less than 0.05 µci/gram of tissue for tritium and carbon-14. Animals may be stored in the designated freezer in the Comparative Medicine Department. The RSO must be informed of intent to dispose of radioactive animal waste. Call Ext. 4-2583. Radioactive Waste Handling & Storage (RSOP 1801) 3/11/2003 4

Lab Disposal of Decayed Waste Closure Date: Amount: mci or µci (circle) Lab Disposal of Decayed Waste Closure Date: Amount: mci or µci (circle) Lab Disposal of Decayed Waste Closure Date: Amount: mci or µci (circle) Radioactive Waste Handling & Storage (RSOP 1801) 3/11/2003 5