FITTING AND CONNECTION OF CENTRAL UNIT EEN-CIC12

Similar documents
FITTING AND OPERATION OF THE VILLA INTERCOM

EN REAL TIME RECEIVER AND RW INSTALLATION AND USE

INSTALLATION AND CONNECTION OF THE KEY SAFE

Multi-door Networking Controller

DG500 Digital Keypad & Proximity Reader

Access control SENATORFX.NET. Quick Start Guide

Installation & Calibration Manual

Quick Reference Guide

Installation Manual for U200 and Overhead

MYOB Support Note. Invoices Aging Incorrectly

Galaxy 300. Operation 05/

4M2 SERIES CONTROLLER OPERATIONS MANUAL Revised (2 thru 4 Stop Residential Elevators)

QUICK Guide. System start-up and shutdown 3. Operating panels. State colors. General process description. Device operating modes

Galaxy 300 and Galaxy 300i

Table of contents. 1. Introduction

Universal Time Clock TM. QuickBooks Plug-in User Guide

ALLIED ELECTRONICS, INC STATION SITE CONTROLLER (SSC) Installation and Start Up Guide. ARCO / ANDI to Wayne PIB

electroplating DC power supply type SIFCO PROCESS POWER PACK 1028

Installation & Operating Instructions. miguard Customer Helpline lines open 0900 to 1700 Monday to Friday

Wireless Freezer Manual Installation Guide

ipourit, Inc. Point of Sale Manual

Terminal Guide. VeriFone. VX520 with VX820 PIN Pad VX820 Duet VX680 3G

Easy-To-Use Time & Attendance System

IRIS Serial Configuration for Galaxy Upload/Download Connections:

CBS-8 SERIES INSTRUCTION MANUAL

IDS 1632 Installer Manual K Issued September 2009

ACCESS CONTROL. Integrated Solutions ALL UNDER CONTROL. Access Control Systems

GPS VEHICLE TRACKER USER MANUAL. Preface

MULTI-PURPOSE THREE PHASE METER

Terminal Guide VeriFone VX520 & VX820 Duet Retail Restaurant

First Data Merchant Solutions EFTPOS. 8006L2-3CR Integrated PIN Pad. User Guide

SABRE P MODEL PD603 PROCESS METER Instruction Manual

Operating instructions, TC543 controller.

Belgacom IDS 310. Reception Terminal Manual. Forum IS16/48/80/160

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Digital Loop Carrier System

MODEL NC405 MULTI-FUNCTION TOUCH-TONE* DECODER INSTRUCTION MANUAL

Troubleshooting Hosted 4500 Timeclocks

LIFT CONTROL WITH HIGH LEVEL INTERFACE (V3 OR LATER)

itemp Anywhere Wireless Sensors and Cellular Gateway User s Guide

Cellcom Fleet. Android User Guide

U g CS for DJI. Mobile companion application. Copyright 2016, Smart Projects Holdings Ltd

Using EcoSystem Ballasts/Drivers in HomeWorks QS Revision D 04/2015

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM Digital Loop Carrier System

QUICK REFERENCE GUIDE

DeskDECT Feature Phone

Substitute Employees. Kronos Time Keeping System. Medford School District 549C August 16, Help Contacts:

Operation Manual Networking & Stand-alone Controller Networking Reader

amiando GmbH Sandstr Munich Germany Support Hotline: CEO: Felix Haas, Dr. Julian de Grahl, Ingo Chu,

GPS Vehicle Tracker Specification VP-203GW

Using the Commonwealth Bank EFTPOS terminal with QuickPOS

XN120 Basic Rate ISDN Guide Rev 1.2 March

Essential Lite. Merchant Operator Guide. Model: Move5000

Dispatch and Navigation User Guide 6100 / Garmin

ALLIED ELECTRONICS, INC STATION SITE CONTROLLER (SSC) Installation and Start Up Guide. ARCO / ANDI to Tokheim

FIXED-WINDOW POWER DEMAND CONTROLLER BY ENERGY PULSES CVM-R8D-CPP INSTRUCTION MANUAL

Delaying Count. Totaling the Register THEN

MSI Cash Register Version 7.5

GONEN AUTOMATION. Eagle-Access. Eagle-Parking. Eagle-Time. Eagle-Presence. Eagle-Meeting Room. Eagle-Job. Eagle-Visitor.

NetSuite OpenAir Mobile for iphone User Guide Version 2.2

Sabre P Model PD603 Process Meter Instruction Manual

Acumatica Warehouse USER GUIDE FOR HANDHELD & MOBILE DEVICES V

Analog Arts High Performance Instruments Comprehensive Instruction Manual

TIONS AMR / AMI SOLU

HICAPS terminal user guide

HARBORTOUCH ECHO USER GUIDE HARBORTOUCH SUPPORT LINE:

MULTIPOINT EARTH LEAKAGE RELAY CBS-8 SERIES USER S MANUAL

UniFocus Time Clock Manager Guide

Requisition Processing Guide

PALLET SCALE CPS SERIES OWNER'S MANUAL

imark Mobile Ordering System

MODEL ASCS-15 CRANE SCALE

PD662 LOOP-POWERED METER

SECURITY SETUP. Version 5.5

INPEX CONTRACT MANAGEMENT SYSTEM

Elevator control setup with Entrapass Special or Corporate edition with KT-400

Model PD656 Large Display Process Meter with Rate/Totalizer/Batch Control Features Instruction Manual

Secure Payment Systems TechTrex PrimeTrex Installation Instructions

INSULATION MONITORING RELAIS

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

Checklist for testing electronic digital indicators with simulated pulses 2/6/08

FRESENIUS LEARNING CENTER QUICK START GUIDE

HRI-R22t series GENERAL FUNCTIONS AND OPERATORS - LEGENDA INSULATION MONITORING VERSIONS FOR USE IN MEDICAL ROOMS

2000 User/ Installer Guide

Operating Instructions GENIUS Control Unit Optional: Serial Interface

MAP Programs Master Menu Options

IBM i Version 7.2. Systems management Advanced job scheduler IBM

ConnectWise-Sage 50 Accounts User Guide

EPS 7000 and EPS 8000

Advantage Mobile Users Guide 06/11/2015

NAB EFTPOS MOBILE. Terminal Guide

PSM (Power System Module / PCU) DK DK DK DK

Toro Radio Interface Unit (RIU) User Guide

RaceGrade Motorsport Keypad

SMARTSCAN 8000 SERIES MUTE MODULES Series Mute Accessories Installation Sheet ( CD174A and CD174B )

ServiceCEO User's Guide

Advantage Mobile Users Guide AQUA

SABRE T MODEL PD743 TEMPERATURE METER Instruction Manual

Model AH-AK 010 Gasifier Control Page 1 of 5

KeyedIn Projects ios App User Guide Version 2.0 June 2015

Transcription:

FITTING AND CONNECTION OF CENTRAL UNIT EEN-CIC12 GENERAL This central unit (ref. EEN-CIC12) enables you to control Intratone products such as Audio and Visio intercom panels, proximity readers, RF receivers and coded keypads. It is also used to control the activation of relays, door opening requests by means of a pushbutton, and the sending of e-mail alerts via the Intratone servers. A) CONNECTION TO THE INTRATONE SERVER This central unit must be connected to the Intratone servers by means of one of the following: - The GPRS module (EEN-MGPRS). - The 3G module (EEN-M3G). - The Visio 2 panel (EEN-PIVI3GV2). B) RELAY CARD Up to 4 relay cards (EEN-CR) can be connected to this central unit via the data bus; these cards allow multiple doors to be controlled using just one of the connection solutions listed above. However, relay cards will not connect to any other Intratone product they are simply used to control another door using a reader, keypad, mobile phone etc. C) HARDWARE CONFIGURATION Intratone products are mainly configured from the management web site tab on the www.intratone.com website. However, some settings need to be adjusted on site using the control panel keypad and screen, or using the programming terminal (EEN-TP): - Pushbutton settings (NO or NC). - Setting the door opening time (from 0.2 to 99 seconds). - Panel volume level (levels 1 to 4). Page 1 / 10

CONTENTS GENERAL ----------------------------------------------------- 1 A) CONNECTION TO THE INTRATONE SERVER ----------------------------------------- 1 B) RELAY CARD ---------------------------------------------------------------------------- 1 C) HARDWARE CONFIGURATION --------------------------------------------------------- 1 CONTENTS --------------------------------------------------- 2 SIZES AND FITTING --------------------------------------- 3 CABLING ------------------------------------------------------ 4 A) TERMINAL FROM BELOW --------------------------------------------------------------- 4 B) ALERT INPUT CABLING ----------------------------------------------------------------- 4 C) RELAY CARD CABLING ----------------------------------------------------------------- 4 D) CABLING FOR DOOR FITTED WITH MAGNET LOCK ---------------------------------- 5 E) CABLING FOR DOOR FITTED WITH ELECTRIC STRIKER PLATE --------------------- 5 HARDWARE CONFIGURATION ------------------------ 6 A) CONFIGURATION ON THE PANEL ----------------------------------------------------- 6 B) CONFIGURATION ON THE CENTRAL UNIT -------------------------------------------- 7 C) CONFIGURATION VIA THE INTRATONE.COM WEBSITE FROM THE MANAGEMENT WEB SITE TAB --------------------------------------------------------------------------------- 7 POST-FITTING CHECKS --------------------------------- 8 A) CENTRAL UNIT LEDS ------------------------------------------------------------------ 8 B) COMMUNICATION CHECKS ------------------------------------------------------------ 8 C) OPENING COMMAND CHECKING ------------------------------------------------------ 8 TROUBLESHOOTING ------------------------------------- 9 CERTIFICATE OF CONFORMITY -------------------- 10 Page 2 / 10

SIZES AND FITTING without cover with cover Page 3 / 10

A) TERMINAL FROM BELOW CABLING +/-: Power supply to the central unit and Intratone equipment (Panel, GPRS or 3G unit, RF receiver, Proximity reader, Coded keypad etc.). D+/D-: Data bus for communication with Intratone equipment (data only). PB/Earth: Pushbutton input to operate relay and open door from inside. Alert/Earth: Alert input to connect a voltage free contact and send an alert by e-mail (can be configured on the Intratone.info website). C-R-T (command): NO contact (between C and T) and NC (between C and R) to control access opening. Supply can be 5A at 12V or 1A at 24V. B) ALERT INPUT CABLING - The alert switch is connected between the Alt and GND terminals on the central unit. - When the switch operates, an e-mail alert is sent once the time before alert sending has been reached. - The switch type can be NO or NC. - All the alert settings can be configured on the www.intratone.com website from the management web site tab. In the central unit menu ( manage alerts button in the box of the connector in question). C) RELAY CARD CABLING EEN-CIC12 EEN-CR (door 2) EEN-CR (door 3) To relay card 4 WARNING! The address of each relay card must be set using the switches (cf. doc. EEN-CR) Page 4 / 10

D) CABLING FOR DOOR FITTED WITH MAGNET LOCK - The pushbutton is wired between the PB and GND terminals on the central unit. - When the button is pressed, the central unit relay cuts the supply to the magnet lock for the period programmed into the central unit. - If the central unit is out of service, the PB s NC contact button also cuts the supply to the magnet lock. - The pushbutton must be set to NO via the central unit menu in order for the following cabling to work (NO by default). - The pushbutton type (NO or NC) is defined within the central unit parameters (cf. page 6) - At rest, the magnet lock (energised) keeps the door closed, - When the relay is activated by the central unit, the supply to the magnet lock is cut; the magnet lock releases the door. G: Power supply - The electric vacuum lock supply voltage must be less than 42 V AC or 60 V DC. If the supply voltage is higher than these values, then an intermediate relay (of the correct rating) must be used to control the electronic lock. - The fitting of a varistor (blue chip) is required for the correct operation of the relay. That varistor is calibrated for a voltage of 12 V. E) CABLING FOR DOOR FITTED WITH ELECTRIC STRIKER PLATE - The pushbutton is wired between the PB and GND terminals on the central unit. - When the button is pressed, the central unit powers the electric striker for the period programmed into the central unit. - If the central unit is out of service, the PB s NO contact button will also power the striker (a failsafe power supply needs to be provided) - The pushbutton must be set to NC via the central unit menu in order for the following cabling to work (NO by default). - The pushbutton type (NO or NC) is defined within the central unit parameters (cf. page 6) - At rest, the striker keeps the door locked, - When the relay is activated by the central unit, the current flows and the striker releases the door. G: Power supply - The electric striker supply voltage must be less than 42 V AC or 60 V DC. If the supply voltage is higher than these values, then an intermediate relay (of the correct rating) must be used to control the electronic lock. - The fitting of a varistor (blue chip) is required for the correct operation of the relay. That varistor is calibrated for a voltage of 12 V. Page 5 / 10

HARDWARE CONFIGURATION A) CONFIGURATION ON THE PANEL The central unit s configuration menu can be accessed by pressing the button for 10 sec. The password required will match the central unit s serial number (7XXXXXX3). Use the buttons to navigate around the menu: - The button enables you to enter a menu and confirm a setting. - The button enables you to navigate around the main menu and change a setting. - The button enables you to exit the menus and programming mode. 5 menus can be accessed from the main menu: 1) Clock setting: From this menu, you can adjust the time, day and date, and also change between summer and winter mode: - Set the time and date using the keypad on the panel. - Set the day and summer/winter mode using the arrow. 2) Door settings: This menu can only be accessed if switches 4, 5 and 6 on the central unit are set to OFF. From this menu, you can select the pushbutton type and adjust the door opening time. By default, the door settings are configured using the switches on the central unit. They must therefore be moved to the programming position to access this menu: - The pushbutton type is configured using the arrow. - The opening time is configured using the keypad on the panel. 3) Panel volume setting: From this menu, you can adjust panel volume levels. Set the volume level (a number from 1 to 4) using the keypad on the panel. (A sample tone will be generated to help you choose the setting.) 4) Internet update request: From this menu you can launch an update directly from the central unit itself. Of course the central unit needs to be connected and registered on the GSM/3G network, and it must require an update from the website. 5) Installation checking: From this menu you can check that the installation is operating correctly (cf. page 9). Page 6 / 10

B) CONFIGURATION ON THE CENTRAL UNIT RESET BUTTON LITHIUM CELL CR2032 3V LEDS L1 to L5 SWITCHES S1 to S6 VIGIK S1 ON Activated OFF Deactivated * SECURITY S2 ON Activated OFF Deactivated NOT USED S3 TIME DELAY S4 ON 05 sec ON S5 ON OFF 10 sec PB TYPE S6 ON Normally Open OFF Normally Closed MODE S3 OFF CONFIGURATION S4 OFF PANEL / HTTP S5 OFF OFF ON 20 sec Setting these 3 switches to OFF enables the time delay to be set, along with the PB type, via the panel or programming terminal. * Door security: For improved door security, connect the striker plate or magnet lock to relays C R and T on the central unit and set switch n 2 on the central unit to ON. - Pressing the pushbutton on the panel will allow that relay to be opened, BUT NOT the central unit relay as well. - Pressing the pushbutton on the central unit will allow the relays on both the central unit and the panel to be opened. C) CONFIGURATION VIA THE INTRATONE.COM WEBSITE FROM THE MANAGEMENT WEB SITE TAB The EEN-CIC12 central unit must previously have been configured on the www.intratone.com website from the management web site tab before use. In order to register the equipment you will need the central unit s serial number (7XXXXXX3). You will also be asked to provide your Intratone contract number. Also remember to make a note of the panel or GSM/3G unit telephone number if you have a fleet contract. Page 7 / 10

POST-FITTING CHECKS Before leaving the site, you will need to check the following: A) CENTRAL UNIT LEDS BLINK RATE L1 L2 L3 L4 L5 Reader Panel Central unit in GSM SLOW service LED OFF FAST Now power to central unit Reader Panel Central unit in ex. works condition : Check cabling: central unit cannot see the peripheral. : Cabling OK: central unit can see the peripheral. GSM Back up problem B) COMMUNICATION CHECKS You can check the operation of the equipment connected to the central unit using the installation checking menu found under the central unit s configuration menu: - Hold the key of the panel during 10 sec. The password to enter is the serial number of the central unit (7XXXXXX3). - Scroll through the central unit menus (4x) until you get to installation checking, then press to enter the menu. - Enter your telephone number to check that calls can be made from the panel, then press. - If your telephone allows it, choose the Visio option (only available if you are connected to the 3G network), then press. - Press to start the process. The * key will open the panel door by default. C) OPENING COMMAND CHECKING In order to check that your door is operating correctly, bridge the PB and Earth terminals (with the PB set to NO) and check that the relay opens the door correctly. Before its 1 st update, the central unit will open for all Mifare badges. You can therefore check that the door will open using an unprogrammed badge. Check that each of the central unit terminals is tightened securely to avoid any interference during data transfer. It is important that all cables are connected via a gooseneck to the central unit in order to prevent any water getting into the central unit connectors. Page 8 / 10

TROUBLESHOOTING What is the fault? LED 1 is off. LED 1 blinks rapidly. The door does not open, but the proximity reader shows green. LED 2 is off. LED 4 is off The door stays open LED 3 blinks rapidly What has caused the fault? There is no power to the central unit. Problem with the data bus or the power supply to the proximity reader or clock. There is a problem with the relay cabling or the door control is out of service. The central unit cannot see the panel. The central unit cannot see the GSM or 3G module - The PB type has been set incorrectly - A free access time period has been set via the management web site - There is a back up problem. How can the fault be rectified? - Check the power supply at the + and terminals. - Check the +, -, D+ and D- connections on the central unit and reader. - Check the time on the central unit. - Check the relay s change of state between C and T using an ohmmeter and bridging the PB and earth terminals. - Check the door can be controlled without the central unit (use wires to simulate the action of the relay). Check the +, -, D+ and D- connections on the central unit and panel. Check the +, -, D+ and D- connections on the central unit and GSM or 3G module. - Check switch 6 or the central unit parameters (if switches 4, 5 and 6 are set to OFF) - Check whether an access time period has been set on the management web site Check that the back up is connected properly. To contact our technical department: France: (+33)251 655 529 UK: (+44)207 092 6613 Page 9 / 10