CONCRETE WALL VENEER

Similar documents
CONCRETE BALUSTRADE SYSTEM

SPECIFICATION GUIDELINE

Sample Specifications

Specifier Note: Retain material(s) below to conform to project requirements.

Sample Specifications

Sample Specification

SPECIFICATION GUIDELINE

MASONRY MORTARING

SECTION MANUFACTURED MASONRY VENEER

SECTION (SOLID/ENGINEERED BAMBOO-EXTERIOR GRADE PRODUCTS)

SECTION ACOUSTICAL CEILINGS (CEMENTITIOUS WOOD FIBER CEILINGS)

ACOUSTICAL WALL TREATMENT 09840

California Architectural Pavers for Mortar-Set Concrete Tiling Installations

UPOFLOOR Quartz Tile Architectural Guide Specification CSI/CSC Section Format [3-part] CSI Page Format

Stonecraft Industies 8300 County Road Holmesville, OH

SECTION BRICK FLOORING

SECTION MANUFACTURED MASONRY VENEER

SECTION NATURAL STONE VENEER

for Mortar-Set Concrete Tiling Installations

Sound-Rite Inc. #9, rd Avenue NE Calgary, AB T2A 7P3. Tel Fax Web

SECTION ACOUSTICAL WALL TREATMENT (CEMENTITIOUS WOOD FIBER WALL PANELS)

MANUFACTURER S SPECIFICATION

SECTION CEMENT BOARD SUPPORTED ADHERED MASONRY VENEER. 2. Installation materials including adhesives, mortars, and pointing mortars.

Reinforced California Architectural Roof Pavers, Pedestal Supported

Narrow Modular Pavers (NMP) for Sand-Set Installations

5GLOBAL. specification guide summary PART 1 GENERAL

Narrow Modular Pavers (NMP) for Mortar-Set Concrete Tiling Installations

SECTION TILING

Build something great. Cultured Stone. 3-Part Specification. section Manufactured masonry. revise footer to suit project/office requirements.

Acrylitex Tilt UP Primer Guide Specification Revised August 1, 2008

PRODUCT GUIDE SPECIFICATION

CONCRETE TILE PAVERS

SECTION HYDRAULIC CEMENT UNDERLAYMENT

SECTION METAL WALL PANELS

SECTION CEMENTITIOUS ROOF DECK (CEMENTITIOUS WOOD FIBER PLANK)

MortarNet (updated to include Insect Barrier) Master Specification

APPLICABLE UNDER SECTIONS: SOLAR ENERGY HEATING EQUIPMENT SOLAR HEATING COLLECTORS METAL WALL PANELS

MANUFACTURER S SPECIFICATIONS Section LIMESTONE PLASTER

LAMINATED VENEER LUMBER

Native Custom Stone Guide Specification 1/30/2012 SECTION MANUFACTURED STONE VENEER

NewTechWood America, Inc.

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

SECTION CONCRETE PAVING SLABS SET IN MORTAR

PAVING SLABS ON AGGREGATE BED FOR ROOF PLAZA DECKS

Division 9: Section RESILIENT ATHLETIC SURFACING (Regupol AktivLok Recycled Rubber)

Thanks for purchasing ARTO high fired terracotta tiles, handmade in Southern California since 1966, and available both glazed and unglazed.

SECTION FOAMED-IN-PLACE INSULATION

SECTION MANUFACTURED STONE VENEER. A. Section Includes: 1. Manufactured stone veneer masonry, accessories, and related materials.

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

Editing notes to assist users are separated from specification text by rows of asterisks. Delete these notes prior to final printing.

BENJAMIN OBDYKE INCORPORATED

XTREME-BOND INSTALLATION SYSTEM

SECTION METAL WALL PANELS

FLOORING TREATMENT

FABRICATED FIREPROOFED STEEL COLUMNS

DIVISION 7 - COMMERCIAL FLUID APPLIED DAMPPROOFING 07110

Specifier Note: Coordinate the following Article with Section Protecting Installed Construction.

SECTION Fiber Reinforced Stucco 1

Sub-Section Paver Tiling

MANUFACTURER S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) MASONRY [BLOCKS] [BRICKS] [STONE]

DIVISION 7 MARFLEX 5000 FLUID APPLIED AIR & VAPOR BARRIER - 3 PART SPEC 07262

SECTION METAL ROOF & WALL PANELS

Product Guide Specification

Accella Polyurethane Systems, LLC

MANUFACTURER'S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE

Ecore Athletic Elevate Roster Interlocking Carpet Tile GUIDE SPECIFICATIONS Ecore

Product Guide Specification

ICC-ES Evaluation Report Reissued November 2014 This report is subject to renewal November 2016

PART 1 GENERAL MANUFACTURED STONE MASONRY

Sections Paver Tiling Guide Specification; for installation of Marion Ceramics, Thin Brick Tiles; Flooring, Veneer

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

Student Services & Classroom Addition

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

SECTION PLUMBING PIPING AND PUMPS

SECTION DEFIBRILLATOR CABINETS

Regupol Aktiv RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER

The following specification refers to the Stepstone, Inc. product known as: Steptreads

SECTION Arisfor WallGuard

1. Amarco Products Athletic Recycled Rubber Sports Flooring Rolls and Interlocking Tiles 2. Adhesives

SECTION (Master Format, 1995 Edition, 04700) MANUFACTURED MASONRY

1. ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Rubbers and Thermoplastic Elastomers-Tension.

SECTION EPOXY TERRAZZO TILE WITH RECYCLED GLASS MATRIX

PIPING SPECIALTIES 15120

SECTION METAL WALL PANELS

Product Guide Specification

CONSULT COLDSPRING FOR ASSISTANCE IN EDITING THIS SPECIFICATION GUIDE FOR SPECIFIC APPLICATIONS.

Fastrack Rolls and Interlocking Tiles GUIDE SPECIFICATIONS Centaur

Architectural Guide Specification CSI/CSC SectionFormat [3-part] CSI PageFormat. Tel Fax

Product Guide Specification Pliteq GenieMat FF06, GenieMat FF10, GenieMat FF17, GenieMat FF25, GenieMat FF50, GenieMat FF75

CSI Exceed PART 1.0 GENERAL. plae.us SUMMARY 1.2 REFERENCES

Spec Master 5/7/ For each product requiring color and texture selection, provide full size samples.

PRODUCT SPECIFICATIONS

Training Ground with Nike Grind RubberX GUIDE SPECIFICATIONS Ecore

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

Transcription:

ARTO Brick and California Pavers 15209 S. Broadway St. Gardena, CA 90248-1823 Phone: (310) 768-8500 Fax: (310) 768-8544 www.artobrick.com This 3-part specification utilizes the Construction Specifications Institute (CSI) Manual of Practice, including MasterFormat., SectionFormat. and PageFormat and is a manufacturer-specific proprietary product specification using the proprietary method of specifying applicable to project specifications and masterguide specifications. Optional text is indicated by brackets [ ]; delete optional text in final copy of specification. Specifier Notes typically precede specification text; delete notes in final copy of specification. Trade/brand names with appropriate symbols typically are used in Specifier Notes; symbols are not used in specification text. Metric conversion, where used, is soft metric conversion. This 3-part specification specifies concrete tile manufactured by Arto Brick California Pavers. Revise section number and title below to suit project requirements, specification practices and section content. Refer to CSI MasterFormat for other section numbers and titles. PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Handmade concrete brick veneer, tiles, and panels for use as wall veneer. B. Related sections: 1. Division 09 Section: Concrete and Masonry Coatings 2. Division 09 Section: Waterproofing Membranes Specifier Note: Article below may be omitted when specifying manufacturer s proprietary products and recommended installation. Retain Reference Article when specifying products and installation by an industry reference standard. If retained, list standard(s) referenced in this section. Indicate issuing authority name, acronym, standard designation and title. Establish policy for indicating edition date of standard referenced. Conditions of the Contract or Division 01 References Section may establish the edition date of standards. This article does not require compliance with standard, but is merely a listing of references used. Article below should list only those industry standards referenced in this section. 1.02 REFERENCES A. American National Standards Institute (ANSI) 1. A108/A118 American National Standards for the Installation of Ceramic Tile B. American Society of Testing and Materials (ASTM International) 1. C33 Specification for Concrete Aggregates 2. C39/C 39M Test Method for Compressive Strength of Cylindrical Concrete Specimens 3. C67 Test Methods for Sampling and Testing Brick and Structural Clay Tile 4. C150 Specification for Portland Cement

5. C157/C 157M Test Method for Length Change of Hardened Hydraulic-Cement Mortar and Concrete 6. C260 Specification for Air-Entraining Admixtures for Concrete 7. C270 Specification for Mortar for Unit Masonry 8. C482 Test Method for Bond Strength of Ceramic Tile to Portland Cement Paste 9. C494/C 494M Specifications for Chemical Admixtures for Concrete 10. C847 Specification for Metal Lath 11. C979 Specification for Pigments for Integrally Colored Concrete 12. C1032 Specification for Woven Wire Plaster Base 13. C1063 Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement- Based Plaster 14. C1116/C1116M Specification for Fiber-Reinforced Concrete 1.03 SYSTEM REQUIREMENTS A. Performance Requirements 1. Absorption (ASTM C140): Not more than 12%. 2. Freeze Thaw Resistance (ASTM C67): Unaffected after 50 cycles. 3. Compressive Strength (ASTM C39): Not less than 4000 psi (27,560 kpa). 4. Length Change (ASTM C157): +/-0.1% max. 5. Bond Strength (ASTM C482): 50 psi (0.3 MPa). Specifier Note: Article below includes submittal of relevant data to be furnished by Contractor before, during or after construction. Coordinate this article with Architect s and Contractor s duties and responsibilities in Conditions of the Contract and Division 01Submittal Procedures Section. 1.04 SUBMITTALS A. General: Submit listed submittals in accordance with Conditions of the Contract and Division 01 Submittal Procedures Section. B. Product Data: Submit product data for specified products. C. Shop Drawings: Indicate layout, patterns, color arrangement, perimeter conditions, junctions with dissimilar materials, control and expansion joints, thresholds, accessories and setting details. D. Maintenance Data: Include recommended cleaning methods, cleaning materials, stain removal methods and polishes and waxes.

Specifier Note: Article below should include prerequisites, standards, limitations and criteria that establish an overall level of quality for products and workmanship for this section. Coordinate article below with Division 01 Quality Assurance Section. E. Samples: Submit selection and verification samples of finishes, colors and textures. 1.05 QUALITY ASSURANCE A. Qualifications 1. Installer experienced in performing work of this section who has specialized in installation of work similar to that required for this project for a minimum of 5 years. B. Regulatory Requirements and Approvals: [Specify applicable requirements of regulatory agencies.]. 1. [Code agency name]. a. [Report or approval number]. Specifier Note: Retain paragraph below for erected assemblies (either onsite or offsite) required for review of construction, coordination of work of several sections, testing or observation of operation. Mock-ups, when accepted or approved, establish standards by which work will be judged. Coordinate below with Division 01 Quality Control (Mock-Up Requirements) Section. C. Mock-Ups: Install at project site a job mock-up using acceptable products and manufacturer approved installation methods. Obtain Owner s and Architect s acceptance of finish color, texture and pattern and workmanship standard(s). Comply with Division 01 Quality Control (Mock-Up Requirements) Section. 1. Mock-Up Size: [Specify mock-up size.]. 2. Maintenance: Maintain mock-up during construction for workmanship comparison; remove and legally dispose of mock-up when no longer required 3. Incorporation: Mock-up may be incorporated into final construction upon Owner s approval. Specifier Note: Article below should include special and unique requirements. Coordinate article below with Division 01 Product Requirements Section. 1.06 DELIVERY, STORAGE & HANDLING A. General: Comply with Division 01 Product Requirements Section. B. Ordering: Comply with manufacturer s ordering instructions and lead time requirements to avoid construction delays. C. Delivery: Deliver materials in manufacturer s original, unopened, undamaged containers with identification labels intact.

D. Storage and Protection: Store materials protected from exposure to harmful environmental conditions and at temperature and humidity conditions recommended by the manufacturer 1.07 ENVIRONMENTAL REQUIREMENTS A. Install mortar, set and grout units when surface temperature is a minimum of 50 degrees F (10 degrees C) and rising but no greater than 90 degrees F (32 degrees C). B. Do not install mortar, set or grout tile when inclement weather conditions are expected within 48 hours of completion. 1.08 EXTRA MATERIALS A. Extra materials: Provide _ ft2 of each size, color and surface finish of tile specified. PART 2 PRODUCTS Specifier Note: Retain article below for proprietary method specification. Add product attributes, performance characteristics, material standards and descriptions as applicable. Use of such phrases as or equal or or approved equal or similar phrases may cause ambiguity in specifications. Such phrases require verification (procedural, legal and regulatory) and assignment of responsibility for determining or equal products. 2.01 CONCRETE WALL VENEER Specifier Note: Paragraph below is an addition to CSI SectionFormat and a supplement to 3-part specificaton. Retain or delete paragraph below per project requirements and specifier s practice. A. Manufacturer: Arto Brick / California Pavers. 1. Contact: 15209 S. Broadway St., Gardena, CA 90248-1823; Telephone: (310) 768-8500; Fax: (310) 768-8544; website: www.artobrick.com. Specifier Note: Edit Paragraph below to suit project requirements. If substitutions are permitted, edit text below. Add text to refer to Division 01 Project Requirements (Product Substitutions Procedures) Section. B. Substitutions: No substitutions permitted. Specifier Note: Paragraphs below list proprietary products offered by Arto Brick California Pavers. All measurements are nominal; consult manufacturer regarding exact measurements and product options. Select product characteristics required; delete characteristics not required. 2.02 BRICK VENEER, WALL TILES AND PANELS A. Style/Size 1. Adobe 2. Antik 3. Artillo

4. Granulated 5. Norman 6. Pachanga 7. Riviera 8. Rocky Mountain 9. Roman 10. Smooth 11. Standard 12. Villagio Specifier Note: Select color(s) below. If more than one color is selected, create color designators and coordinate with drawings. B. Color 1. Antik Gray 2. Artillo 3. Artillo Café 4. Beachwood Flash 5. Buff 6. Café Olay 7. Cauqi 8. Charcoal 9. Charley Brown 10. Chicago 11. City Hall Red 12. Cotto Dark 13. Cotto Gold 14. Desert 15. Early Gray 16. El Segundo 17. Flagstone 18. Gold 19. Grey Myst

20. Hacienda 21. Hacienda Flash 22. Hancock 23. Hermosa Blend 24. Jose Gray 25. Lopez Brown 26. Los Angeles 27. Metro 28. Mission Red 29. Natural Gray 30. Normandy Cream 31. Ocean Green 32. Old California 33. Plumish 34. Red Flash 35. Rice 36. Rosa 37. Rosa White Wash 38. Sangria 39. Santa Monica 40. Sidewalk Gray 41. Smoke 42. Sonora Sunset 43. Tuscan Mustard 44. Urban 45. Used Desert 46. Used Red Specifier Note: Refer to Arto color chart to view color options. Request samples from Arto or distributor in order to view and approve color variation. C. Texture 1. Standard

2. Limestone 3. Luna 4. Travertine 5. Acid Wash 6. Sand Blast 2.03 CORNERS AND ACCESSORIES A. Size/Style B. Color C. Texture Specifier Note: Indicate if color and texture specified for corners and accessories differ from wall veneer color and texture. 2.04 MATERIALS A. Mortar 1. ASTM C270, Type S 2. Thin set mortar 3. Medium bed mortar Specifier Note: Recommended for large format (8x8 or larger) tiles and panels B. Grout 1. Grout with sanded Type S mortar or other grout specified. Ensure grout selected is appropriate for grout joint width specified and installation location. 2. Grout using a grout bag and remove excess grout once it has set up but before it has hardened. Units can be presealed to ease grout removal. C. Sealer 1. Wall veneer may be sealed to protect surface finish and color. 2. Types of sealer a. Penetrating seals below surface, matte finish, breathable surface a. Topical seals above surface, glossy finish, superior stain protection 3. Sealing recommendations a. Interior applications penetrating sealer or topical sealer, depending on look and stain protection desired

a. Exterior applications penetrating sealer only. D. Water resistive barrier 1. Recommended for exterior applications 2. ASTM D226 No.15 Type 1, minimum of two layers, or 3. Grade D Paper, minimum of two layers, or 4. Tyvek, Typar, other House Wrap. 5. Paper and House Wrap must meet requirements of ICC Acceptance Criteria AC 38. E. Metal Lath 1. ASTM C847, 2.5 lb. or 3.4 lb self-furred, corrosion resistant lath. 2. ASTM C1032, 18 gauge woven wire mesh. 3. Alternative lath must comply with CC-ES AC 275. F. Fasteners 1. ASTM C1063, corrosion resistant fasteners PART 3 EXECUTION Specifier Note: Paragraph below is an addition to CSI SectionFormat and a supplement to this three-part specification. Retain or delete paragraph below per project requirements and specifier s practice. 3.01 MANUFACTURER S INSTRUCTIONS A. Compliance: Comply with manufacturer s product data, including product technical bulletins, product catalog installation instructions and product carton instructions for installation. 3.02 EXAMINATION A. Site Verification of Conditions: Verify that substrate conditions, which have been previously installed under other sections, are acceptable for product installation in accordance with manufacturer s instructions. 1. Wall veneer may be bonded directly to clean concrete, masonry, CMU blocks, and cementitious backer board substrates. 2. Concrete substrates shall have roughened or troweled surfaces to allow for bonding. Prepare substrates with metal lath and scratch coat if ability to adhere is in doubt. 3. Do not bond directly to plywood, OSB, or gypsum based backer board. Install over metal lath and scratch coat or other suitable alternative preparation.

4. Ensure all substrates are clean and free of contaminants. 5. Maximum substrate variation from required plane shall be 1/8 in 10 feet or as otherwise specified. B. Movement joints 1. Must be included per ANSI/TCA guidelines 3.03 PREPARATION A. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. 3.04 CLEANING A. Clean with water and soft nylon brushes only; do not allow mortar to set up on surfaces. 1. Excessive water may affect curing of grout and mortar bed. B. Do not use acid or alkali cleansers which may damage the surface of the tile. C. Test all products before wholesale application. 3.05 PROTECTION A. Protect installed products until completion of project. B. Repair or replace damaged products prior to Substantial Completion. END OF SECTION