Second and Delaware, Kansas City, MO Passive House Institute US PHIUS 1

Similar documents
Second and Delaware, Kansas City, MO Passive House Institute US PHIUS 1

PHIUS+2015 CLIMATE SPECIFIC PASSIVE BUILDING STANDARD: Cliff Notes PATHWAY TO ZERO CARBON

INTRODUCTION TO WUFI PASSIVE & PHIUS+ 2015

Passive House

ASHRAE Standard 90.1 App G, PHI and PHIUS+

Deep Energy Retrofit of a HighRise MURB

PV Generation Potential 17.1 kbtu/ft2/yr 15.4

MID-RISE APARTMENT BUILDING PROTOTYPE HIGH PERFORMANCE PV Genera on Poten al 10.8 kbtu/ 2/yr

Homesol Passive House Design Process

5/8/2018. PHIUS+ 2018: What s New? Graham S. Wright. More nuance for different building types. Supports our overall transition to renewable energy.

LOW-RISE APARTMENT BUILDING PROTOTYPE HIGH PERFORMANCE PV Genera on Poten al 17.9 kbtu/ 2/yr

PV Generation Potential 17.1 kbtu/ft2/yr 15.4

Passive Design Solutions. Passive House The Road to Net-Zero

MID-RISE APARTMENT BUILDING PROTOTYPE PHIUS - WUFI PASSIVE

PHIUS+ Certification for Multifamily Performance Requirements (v2.1) 1

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

Passive House in North America. BEYOND PROOF OF CONCEPT Building the Community, Scaling Up + Climate Specific Design

Designing and Constructing a High-Performance Building Envelope for Multi-Unit Affordable Housing

ECO-RETROFITTING VERY OLD DWELLINGS: CURRENT AND FUTURE ENERGY AND CARBON PERFORMANCE FOR TWO UK CITIES

High-Performance Wood Structures: An Example of Increased Efficiency in Multi- Family Construction

Green Building Standards

72% electricity consumption 39% energy use 38% CO 2 emissions 40% raw materials 30% waste output 14% potable water use

Multifamily Passive House: Into the Weeds

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

PASSIVE HOUSE FACT SHEET (pg 1 of 2)

High-Performing Home Certificate. Certified Solar

Hamilton Way - Case Study of a High Performance Community in a Cold Climate

Passive House in Canada: Case Studies on a Near EnerPHit Retrofit and Post-Occupancy Research

February 28, Prepared by: Michael Flatt ICF International 7160 North Dallas Parkway Suite 340 Plano, TX 75024

Mind the Gaps: Post-Occupancy Discoveries from Design to Operation

PassivHaus/ EnerPHit Introduction. Maiia Guermanova behalf of

Future tree planting on the two acre lot will offset remaining lifetime carbon emissions.

Passive House Retrofit of a VT House

Could a European Super Energy Efficient Standard Be Suitable for the U.S.? John Broniek, IBACOS BEST1 CONFERENCE June 12, 2008

Built examples and project certification. Zeno Bastian, Passive House Institute

Certification Guidebook

Project Description. Projected build start date 12 Apr 2010 Projected date of occupation 28 Feb

High Performance Design in Oregon, Two Regional Case Studies AFE 2.0

TOP 10 STRATEGIES FOR NEW AND EXISTING BUILDINGS

Green Retrofit. Why you should consider it, what it means, and how to get it done

US building impacts. 72% electricity consumption 39% energy use 38% CO 2 emissions 40% raw materials 30% waste output 14% potable water use

Solara: A Case Study in Zero Net Energy Design for Affordable Housing

Scott Cummings Dow Building Solutions Adam Weesner MSKTD & Associates Linda Jeng Dow Building Solutions

ACHIEVING. 80x50. Reducing Energy Use, Creating Jobs, and Phasing Out Carbon Emissions in New York City s Buildings BY EDWARD MAZRIA

Energy Retrofit Loan Program

Assignment 3 Integrated Energy Design

Analysis 2: Alternative Thermal Window Design

Project Description. Projected build start date 01 May 2010 Projected date of occupation 01 Nov Belfast, County Antrim, Northern Ireland

IN THIS ISSUE INTRODUCTION BACKGROUND. March 2018 High Humidity in Winter: Analysis for Multi-Family Passive House Projects

Approaches to Efficient Envelope Design Air Barrier for High-Performance Buildings Alex Boetzel, Director of Sustainability and Operations

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Non-Residential Passive House Buildings

Holistic Design Approach For Energy Efficiency ASHRAE TECHNOLOGY AWARD CASE STUDIES

D3.9_Overall Refurbishment Plan DRAFT CS03. Hotel Restaurant Valcanover

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION. Florida Department of Business and Professional Regulation - Residential Performance Method

FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION. Florida Department of Business and Professional Regulation - Residential Performance Method

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 01 Aug Energy target.

Benchmarking EPA Portfolio Manager and Energy Star Certification

6 th Annual North American Passive House Conference. Evaluation of Potential for Moisture in High R- value Walls in Cold Climates

State Of The Art Office Building & Campus For Maharashtra Energy Development Agency(MEDA) At AUNDH, PUNE

PASSIVE HOUSE IN STUDENT HOUSING

Performance-Risk Methodology for the Design of High-Performance Affordable Homes

Be Aggressive About the Passive Solutions

2017 SeaBEC Symposium. Advancing Building Enclosures Beyond Code Conformance. Medgar Marceau, PE Principal, Senior Building Science Engineer

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Public Sector New Construction Overview Calendar Year 2018

Project Description. Projected build start date 02 Aug 2010 Projected date of occupation 03 Dec Existing external wall construction

THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS

Zero Energy Building Example in Estonia. Tõnu Mauring

The Passive House Institute US

Princedale Road Post Occupancy Evaluation

Case study of an ECBC Compliant, Energy Efficient Building: Aranya Bhawan, Jaipur

Project name SOLAR HOUSE 80/50 Project summary

NY13 PASSIVE HOUSE SYMPOSIUM

NYSERDA High Performance Development Challenge Energy Monitoring Report Hudson Passive Project

ScienceDirect. Simulation based mixed mode building design

Here Comes The Sun Applications of Solar Energy. Marc Rosenbaum, P.E. South Mountain Company West Tisbury, MA

Zero Net Energy Buildings February 12, 2014 Beth Brummitt, CEM, CEA, LEED AP. Your guide for improving the performance and value of buildings

Step Code for Part 9 Buildings: Process and Case Studies

Zero Energy House in Japan: Actual results and future target. Isamu Ohta Misawa Homes Institute of Research & Development CO., LTD.

Catalogue of Learning Targets. Certified PHPP Expert

Passivhaus Introduction

PHPP Report. Beattie Passive Inchkeith Drive

Minimum Energy Consumption 84% energy heating savings*

Residential Codes FAQs: 2015 International Energy Conservation Code (IECC) with MA Amendments & MA Stretch Energy Code

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

OSU Cascades Net Zero Campus. Recommendations

COMPARISON OF ENERGY USE INDICATORS OF A NON-RESIDENTIAL PASSIVE HOUSE WITH ASHRAE 90.1 BUDGET BUILDING

Project Description. Projected build start date 19 Apr 2010 Projected date of occupation 30 Sep

Do You Want to Dance?

Twenty-first Century Building Design: Getting to Net-Zero Energy?

Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL).

Holistic Design Approach For Energy Efficiency ASHRAE TECHNOLOGY AWARD CASE STUDIES

ENERGY STAR Multifamily High-Rise (MFHR)

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa

equest Home Energy Model ME 514 ~ HVAC Sean Rosin University of Idaho/Boise State University Spring 2016

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012

27/10/15. Rod Hughes Architect Director 2030 architects ltd. Penrith

Green Building & RESNET Raters. Vera Novak, LEED AP Insulating Concrete Form Association

Transcription:

Second and Delaware, Kansas City, MO 2017 Passive House Institute US PHIUS 1

FUTURE WORLDWIDE TRANSITION 1800 1600 1400 1200 1000 800 600 400 200 energy-efficiency new geo-/ozean. power solar windpower waterpower new biomass trad. Biomass nuclear gas oil coal 0 1890 1910 1930 1950 1970 1990 2010 2030 2050 2070 2090 Reference: Shell Study (till 2005), Scenario with high efficiency and regenerative usage of energy 2017 Passive House Institute US 2

PHIUS+ PROJECTS NATIONWIDE 70+ MULTIFAMILY SUBMITTED, PRE-CERTIFIED, CERTIFIED SITE EUIs OF 10-25 kbtu/ft².yr 3 ~20-50% better than DOE s Zero Energy Home Program

~350+ PROJECTS IN NORTH AMERICA 2017 Passive House Institute US 4

PASSIVE HOUSE US DATABASE Source: www.phius.org PHIUS CERTIFIED PROJECTS 2017 PHIUS 5

NY STATE AND CITY SQFT OCTOBER 2016 PHIUS+ PROJECTS 410,000 SQ FT TOTAL DOCUMENTED SUBMISSIONS 2017 PHIUS 6

PHI AND PHIUS+ TRENDS IN NA: CERTIFICATIONS BY END OF 2016 2017 PHIUS 7

PHIUS+ TRENDS FOR 2017 Source: www.phius.org 95% of total certified and pre-certified passive building construction (SQFT) in NA 2017 PHIUS 8

DESIGN &VERIFICATION TOOLS, STANDARDS, MODELING PROTOCOLS

WHOLE BUILDING ENERGY BALANCE WUFI Passive PHPP WUFI Plus 2017 PHIUS 10

TERMINOLOGY Demands, Peaks, Site & Primary Energy Annual Demand [kbtu/yr.ft 2 ]: Space conditioning energy consumed over the course of the year, delivered by the equipment to the space. Peak Load [BTU/hr.ft 2 ]: Space conditioning requirement during the peak climate conditions (average over the worst 24 hours). Determines the size of the mechanical system. Site Energy [kwh/person.yr] OR [kbtu/yr.ft 2 ]: Total energy consumed over the course of the year, including space conditioning, hot water, plug loads, lighting, appliances, systems, etc. (Excludes electrical vehicle charging energy, and ligthing energy specific to vehicle parking areas) *No requirement for PHIUS+ Certification Source (Primary) Energy [kwh/person.yr] OR [kbtu/yr.ft 2 ]: Site energy as described above, multiplied by the source/primary energy factor for the specific fuel type used. Ex: Electricity has a PE factor of 3.16 kwh/kwh (generation at the source vs use on site) 11 2017 Passive House Institute US PHIUS 11

EUROPEAN PASSIVHAUS CRITERIA or (+ allowance for latent) 2017 Passive House Institute US 12

PHIUS+2015: CLIMATE SPECIFIC DESIGN Graph Courtesy of Global Buildings Performance Network 2017 Passive House Institute US 13

PHIUS+ 2015 PASSIVE BUILDING CRITERIA AND 2017 Passive House Institute US 14

PHIUS+ 2015 COMMERCIAL PASSIVE BUILDING CRITERIA SAME EXCEPT SOURCE ENERGY CRITERION: CHANGE TO PER AREA+PROCESS LOAD SPECIFIC CRITERION IF APPLICABLE 38 AND 2017 Passive House Institute US 15

METHODOLOGY Climate Specific & Cost Optimal Standards Developed by US Industry NREL BEopt optimizes upgrade package by climate Standards defined as cost optimal/competitive sweetspot between conservation and generation on the path to zero 16 2017 Passive House Institute US PHIUS 16

NEW STANDARDS IDENTIFY US ECONOMIC OPTIMUM TAKING PV COST INTO ACCOUNT PHI target 10 W/m² PHI target 15 kwh/m 2 yr http://www.nrel.gov/docs/fy15osti/64278.pdf15 kwh/m 2 yr 2017 PHIUS 17

EXAMPLE DASHBOARD CALCULATOR 2017 Passive House Institute US 18

CLIMATE SPECIFIC METRICS PASSIVE STANDARDS IN VARYING CLIMATES 2017 Passive House Institute US PHIUS 19

PERFORMANCE CRITERIA DIFFERENCES Annual Demand, Peak, Source & Air-tightness PHI CERTIFICATION does not require US industry standards One annual demand target for space conditioning for all climates with an additional allowance for dehumidification based on climate Targets not cost-optimized by location No mandatory climate specific peak load target to assure thermal comfort Source energy target per square foot for residential and commercial & PER based on German conversion factors Air-tightness measured relative to building volume Standard applied to residential and commercial, separate & less stringent standard for retrofit projects PHIUS+2015 requires US industry standards (DOE ZERH, ES, Indoor AIR Plus) Climate specific annual demand targets for all space conditioning Targets cost-optimized by location Mandatory peak load targets to assure thermal performance & resilience Source energy target per person for residential, square foot for commercial based on US conversion factors Air-tightness measured relative to opaque envelope area Standard applied to all building types including retrofits with an additional allowance for existing thermal bridging 2017 Passive House Institute US PHIUS 20

DOE PERFORMANCE STAIRCASE 2017 Passive House Institute US PHIUS 21

COOPERATION WITH ZERH YIELDS HERS Source: http://energy.gov/sites/prod/files/2016/04/f3 0/Green%20Future_Presentation_2016.pdf 22 2017 Passive House Institute US PHIUS

CERTIFICATION PROTOCOL DIFFERENCES Internal Gains, TFA and icfa, Occupancy & MELs PHI PHIUS+2015 Unrealistically low internal gain default assumptions Treated Floor Area (TFA) energy reference area EUIs are not directly comparable! Occupancy assumption by fixed square foot per person Different MEL and lighting assumptions Source EUI based on German conversion factors not directly comparable! 80% of RESNET internal gain assumptions Interior conditioned floor area (icfa) energy reference area EUIs are not directly comparable! Occupancy calculated bedrooms +1 Different MEL and lighting assumptions Source EUI based on US conversion factors not directly comparable! 23 2017 Passive House Institute US PHIUS 23

Site Energy: Monitored vs Modeled 60,000 50,000 Monthly (kwh) 40,000 30,000 20,000 10,000 - Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Monitored (Electricity + Gas) kwh Modeled - ASHRAE 90.1-2010 Modeled - PHIUS+ 2015 Modeled - PHI Standard Orchards at Orenco I

Site Energy: Monitored vs Adjusted Models 35 32.2 30 Site Energy Comparison 25 20 15 23.3 23.9 16.5 10 5 0 kbtu/sf.yr Modeled - ASHRAE 90.1-2010 Modeled - PHIUS+ 2015 Monitored (Electricity + Gas) kwh Modeled - PHI Standard Orchards at Orenco I

BASIC PASSIVE BUILDING PRINCIPLES

PASSIVE BUILDING PRINCIPLES 2017 PHIUS 27

MULTIFAMILY HAS BETTER SURFACE TO VOLUME RATIO THAN SMALLER STRUCTURES Single Family Home Specs: R-50 WALLS R-90 ROOF R-50 SLAB R-8 WINDOWS Large Multifamily Specs: R-32 WALLS R-50 ROOF R-20 SLAB R-5 WINDOWS 2017 Passive House Institute US 28

PH THERMAL COMFORT RANGE Interior comfort conditions winter 68 º F, summer 77 º F, RH 40 60% Source: ASHRAE Standard 55-2010 Thermal Environmental Conditions for Human Occupancy 2017 PHIUS 29

CONTINUOUS INSULATION INSULATED CONCRETE FORMS 2017 Passive House Institute US 30

THERMAL BREAKS 2017 Passive House Institute US PHIUS 31

MINIMIZE POINT TB LOSS Photo courtesy Jesse Thompson Illustrations by RDH, Shawn Colin, NAPHC 2014 STRUCTURAL THERMAL BRIDGING CAUSED BY CLADDING SYSTEMS ATTACHMENT RED SPACER BEHIND STAND-OFF=THERMAL BREAK 2017 Passive House Institute US 32

UPTOWN LOFTS STRUCTURAL THERMAL BRIDGE ISSUE: SEPARATION TO UNCONDITIONED PARKING DECK Photo: Jesse Thompson 2017 Passive House Institute US 33

AIR-TIGHTNESS BENEFITS Energy benefits: Minimizes energy losses in conjunction with ventilation Minimizes latent loads in conjunction with ventilation Hygrothermal benefits: Minimizes moisture traveling into the wall through infiltration or exfiltration Minimizes condensation risk in components Increases durability of assemblies 2017 Passive House Institute US PHIUS 34

Source: www.prosoco.com/r-guard EXTERIOR AIR BARRIERS EASE OF CONTINUOUS APPLICATION: SPRAY-APPLIED FOR MF PROJECTS 2017 Passive House Institute US PHIUS 35

HIGH PERFORMANCE WINDOWS FOR BETTER COMFORT IMPROVING WINDOW PERFORMANCE MINIMIZES HEAT LOSS/GAIN, ASSURES THERMAL COMFORT, ELIMINATES CONDENSATION CPHC Training 2017 Passive House Institute US 36

DIALING IN WINDOW PERFORMANCE BY CLIMATE 2017 Passive House Institute US PHIUS 37

BALANCED VENTILATION HEAT RECOVERY & SPACE CONDITIONING 2017 Passive House Institute US PHIUS 38

CENTRALIZED VENTILATION W/INTEGRATED SPACE CONDITIONING 2017 PHIUS 39 Source: 2014 NAPHC Proceedings, Orchards at Orenco

DECENTRALIZED SOLUTION 2017 PHIUS 2016 Passive House Institute US 40

SEMIDECENTRALIZED Most common solution - Individual ventilator in each unit Better controls, more accurate ventilation air delivery Solution for local codes where exhaust can not be drawn from all apartments and go through a common air to air heat exchanger Space conditioning via central VRF system Separate supply ducts from ventilation air due to different air velocities during space conditioning 2017 PHIUS 41

Client to provide images COMPARTMENTALIZATION OF UNITS TO CONTROL STACK EFFECT IDEALLY ONE VENTILATOR PER UNIT FOR INDIVIDUAL CONTROL 2017 Passive House Institute US 42

WUFI PASSIVE VERIFICATION Second & Delaware CPHC Prudence Ferreira PHIUS+ 2015 project 2017 Passive House Institute US PHIUS 43

INCENTIVES, LEGISLATION, FINANCIAL TOOLS CPHC Training 2015 Passive House Institute US Module 8 44

LEGISLATION & INCENTIVES 2017 PHIUS 45

MASSACHUSETTS 780 CMR: STATE BOARD OF BUILDING REGULATIONS & STANDARDS N1106.1.1 (R406.1.1) Approved Alternative Energy Performance Methods. The following rating threshold criteria are sufficient to demonstrate energy code compliance under section N1106 without calculation of a standard reference design. The mandatory provisions of subsection N1106.2 also apply: 1. ENERGY STAR Homes 3.1 path. 2. Passive House Institute US (PHIUS) Approved Software. PHIUS+ 2015: Passive Building Standard - North America, or another approved software by PHIUS, where Specific Space Heat Demand, as modeled by a Certified Passive House Consultant, is less than or equal to 10 kbtu/ft²/year. Compliance with this section requires that the criteria of C402.4, C403.2, C404, and C405 are met. 46 2017 Passive House Institute US PHIUS 46

MASSACHUSETTS 780 CMR: STATE BOARD OF BUILDING REGULATIONS & STANDARDS C407.6.1.1 Approved Alternative Energy Performance Methods. The requirements of this section are approved performance methods to demonstrate compliance with Section C407 without calculation of a standard reference design: 1. RESNET Approved Software for Home Energy Rating System (HERS). 2. Passive House Institute US (PHIUS) Approved Software. PHIUS+ 2015: Passive Building Standard - North America, or another approved software by PHIUS, where Specific Space Heat Demand, as modeled by a Certified Passive House Consultant, is less than or equal to 10 kbtu/ft²/year. Compliance with this section requires that the criteria of C402.4, C403.2, C404, and C405 are met. 47 2017 Passive House Institute US PHIUS 47

HUD INCENTIVES Energy Efficiency Measures in MF Projects Multifamily Accelerated Processing (MAP) Guide, 4430.G: FHA explicitly recognizes and underwrites projected utility savings resulting from energy efficiency improvements. To qualify for these credits, projects must demonstrate proposed savings through an energy audit. FHA will underwrite up to 75 percent of proposed savings. FHA to cut Mortgage Insurance Rates on Multifamily Mortgages: The rate reductions announced today will take effect on April 1, 2016, and will directly impact FHA s Multifamily Housing Programs and properties housing low- and moderate-income families and/or developments installing energy-efficient systems or building within federal energy guidelines. 48 2017 Passive House Institute US PHIUS 48

49 2017 Passive House Institute US PHIUS 49

50 2017 Passive House Institute US PHIUS 50

EXAMPLE PROJECTS Orenco Station, Portland, OR, 57 Units 2017 Passive House Institute US PHIUS 51

McKeeseport, Action Housing, Pittsburgh 80 UNIT SRO MULTIFAMILY BUILDING RETROFIT 2016 PHIUS 2017 Passive House Institute US 52

Kiln Appartments,Portland, Oregon 18 UNIT MULTIFAMILY BUILDING MARKET RATE 2017 Passive House Institute US 53

PASSIVE BUILDINGS Stellar Apartments, 16 Units, Eugene, OR Knickerbocker Project, 24 Units, Brooklyn, NY, Chris Benedict AFFORDABLE DEVELOPMENTS 2017 Passive House Institute US PHIUS 54

UPTOWN LOFTS - AFFORDABLE DEVELOPMENT IN PITTSBURGH Uptown Lofts, Pittsburgh, PA FIRST AFFORDABLE FULLY CERTIFIED 24 UNIT BUILDING 2017 Passive House Institute US PHIUS 55

Orchards at Orenco Station Phase II, Portland, OR ORCHARDS AT ORENCO PHASE II 2017 Passive House Institute US PHIUS 56

RECENTLY COMPLETED Weinberg Commons, Washington DC AFFORDABLE RETROFIT PROJECT IN WASHINGTON DC 2017 Passive House Institute US PHIUS 57

CHOM Village Center, Brewer, ME COMPLETED - DEVELOPMENT WITH 47 UNITS 2017 Passive House Institute US PHIUS 58

W 153 rd St, New York, NY 2017 Passive House Institute US PHIUS 59

Beach Green North, New York, NY LARGEST MIDRISE UNDER CONSTRUCTION WITH 101 UNITS 2017 Passive House Institute US PHIUS 60

3365 3 rd Avenue, Bronx, NY 3365 3 rd AVENUE, BRONX, NY 2017 Passive House Institute US PHIUS 61

425 Grand Concourse, NY, NY HI-RISE PLANNED FOR BRONX, NY 2017 Passive House Institute US PHIUS 62

PHIUS MULTIFAMILY RESOURCE CENTER Source: http:/multifamily.phius.org/ 2017 Passive House Institute US PHIUS 63

PHIUS MULTIFAMILY RESOURCE CENTER 2017 Passive House Institute US PHIUS 64

EXAMPLE COMMERCIAL PROJECTS Sunshine Terrace, Washington State FIRST LICENSED HEALTH FACILITY, 34 UNITS 2017 Passive House Institute US PHIUS 65

Seventh Day Adventist Church, NY FIRST CHURCH KINDERHOOK 2017 Passive House Institute US PHIUS 66

Rocky Mountain Institute Innovation Center, Basalt, CO NEW RMI HEADQUARTERS IN BASALT 2017 Passive House Institute US PHIUS 67

FEASIBILITY STUDIES Offices Chicago, IL 249 unit - NYC 209 unit - NYC Hotel Boston, MA Hotel Pittsburgh, PA Passive House Institute US 2016 2017 Passive House Institute US 68

PASSIVE BUILDING IS PART OF THE SOLUTION Katrin Klingenberg, Executive Director www.phius.org/www.phaus.org 2017 Passive House Institute US PHIUS 69