CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

Similar documents
TYPE "A" CATCH BASIN

EROSION CONTROL GENERAL NOTES EC JAN 2017 C.B.

PERMANENT PAVEMENT REPAIR NO SCALE

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

SANITARY MANHOLE S-1 ENGINEERING DEPARTMENT PLATE NUMBER NEENAH R-1733 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL.

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

Construction Inspection Checklists

CITY OF SCHERTZ TEXAS ENGINEERING AND PUBLIC WORKS

Section 403. DRAINAGE STRUCTURES

Drainage structure refers to manholes, catch basins, leaching basins, inlets and drop inlets. Drainage structures are designated as follows.

Failure to acknowledge all addenda in the BID may cause rejection of the BID. See Instructions to Bidders.

Appendix B.2. Construction Specifications for Infiltration Practices

CITY OF NORTHFIELD, MINNESOTA STANDARD DETAILS INDEX

ESTIMATED DISTRIBUTION OF MATERIAL LIST Lomitas Negras Phase 2 Southern Sandoval County Arroyo Flood Control Authority

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

Current Standard Plates including Transmittal Letters are available on the web at:

SECTION STORM DRAINAGE

Inflow pipe. Drain. Drain

WQ-08 ENHANCED DRY SWALE

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY CAST-IN-PLACE. Section CAST-IN-PLACE CONCRETE MANHOLES

B. Fiberglass for construction in back lot easements placed on cast-in-place base.

SECTION A-A NTS. Figure 4.1 Alternative Flow Dispersal Trench NOTES:

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork.

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS

BMP 6.4.4: Infiltration Trench

SECTION D2 MANHOLES AND CATCH BASINS GENERAL MATERIALS

Figure Inlet protection (Source: Minnesota DOT)

Special Provision No. 405F03 March 2005

FOR CRITICAL AREAS ADJACENT TO WETLANDS OR BELOW LONG AND/OR STEEP SLOPES, STEEL POSTS ARE NECESSARY AS INDICATED ON THE PLANS.

At least 2 feet above the seasonal high water table Overflow path or structure provided

SECTION UTILITY MANHOLES AND STRUCTURES

CITY OF NEW BERLIN DEVELOPMENT HANDBOOK SECTION 4 STORM SYSTEM. 1 of 15 Adopted by BPW:

FOR HISTORICAL REFERENCE ONLY

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST

Project Location: Various, Anywhere, PA Bid Date: 7/16/ Rock Construction Entrance

Rhode Island Stormwater Design and Installation Standards Manual

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

SECTION STORM DRAINAGE UTILITIES. B. Section : Site Restoration and Rehabilitation

CHAPTER 17: STORM SEWER STANDARDS Introduction Administration Standards 17.1

GWINNETT COUNTY STORM SEWER PIPE STANDARDS

Infrastructure Typical Details

STANDARD DETAIL SPECIFICATIONS FOR SANITARY AND STORM SEWER SYSTEMS CITY OF EDEN PRAIRIE, MINNESOTA INDEX. 1. Scope of Work... S-1

PERMEABLE INTERLOCKING PAVERS

IN T R A / M IN T R A M

4.8. Subsurface Infiltration

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Section 404. UNDERDRAINS

EXISTING CONDITIONS. Town of Bedford, NH Sand Volleyball Courts Existing Conditions Sheet 2 of 5 GENERAL NOTES

CHECK THE LOWER RIGHT CORNER OF EACH DETAIL FOR THE LATEST REVISION.

Stormwater Management The District exercises regulatory authority for Stormwater Management in the City of Edina.

SOUTHSIDE TOWNSHIP ROADWAY STANDARDS POLICY Adopted September 7, 2004

PROJECT AT THE DENVER

SECTION PRECAST CONCRETE MANHOLES

Section 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1

A. This section includes the furnishing and installation of a foundation drainage system.

Highway Drainage 1- Storm Frequency and Runoff 1.1- Runoff Determination

4.8. Subsurface Infiltration

PUBLIC WORKS SKAGIT COUNTY SAMISH ISLAND ROAD SAMISH ISLAND ROAD SLIDE REPAIR

LOT D-4B LOUISE DRIVE 3 STORY, 90 ROOM HOTEL UPPER ALLEN TOWNSHIP, CUMBERLAND COUNTY, PENNSYLVANIA

D-1 THE CITY OF HARRISBURG 1 1/2" MIN. ID-2 WEARING COARSE EXISTING STREET SURFACE AC-20 SEALER (ALL AROUND) 1 1/2" MIN. ID-2 BINDER COARSE

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details

(SIZE) MANHOLES CATCH BASINS AND DITCH INLETS -Item No. ADJUSTING AND REBUILDING MANHOLES, CATCH BASINS AND DITCH INLETS - Item No.

Division 33. Utilities

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

1.02 RELATED WORK: Refer to the following sections for related work:

PRECAST CONCRETE MANHOLES. A. Precast concrete manholes for sanitary sewers, storm sewers, and water lines.

Suggested Stormwater Management Practices For Individual House Lots

q Item meets standard Project ID: X Item not acceptable Contractor: N/A Item not applicable Inspector: C Item requires engineer s cert.

OAK MARSH PHASE II FEASIBILITY REPORT CITY OF MANKATO MINNEOSTA. January 20, 2015 Project No

I. Preconstruction Meeting and Site Preparation Date: Inspector: A. MDE Certified Installer Name

SECTION STORM DRAINAGE. A. This Section includes gravity-flow, nonpressure storm drainage (REMOVED), with the following components:

AMENDMENTS TO OPSS 408 (OCT 89) CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MANHOLES, CATCH BASINS, DITCH INLETS AND VALVE CHAMBERS

STORM AND SURFACE WATER 4-1 GENERAL...4-1

Stormwater Quality Review Checklist - General

DIVISION 33 UTILITIES

New Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M

SECTION TRENCHING

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section PRECAST CONCRETE MANHOLES

The work required for this project includes, but is not limited to, the following items, not listed in order of execution.

Storm Drainage

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SPECIFICATIONS FOR STREET CONSTRUCTION WITHIN THE TOWN OF PLAINVILLE

Chapter 3 - Excavation

EROSION AND SEDIMENTATION CONTROL SECTION 1 - GENERAL 1.1 SUMMARY

ENGINEERING CHECKLIST SEDIMENT & STORMWATER MANAGEMENT BASIN CONSTRUCTION

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated.

CITY OF ORONO STANDARD CONSTRUCTION DETAILS

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

SECTION STORM DRAINAGE SYSTEM Excavating, Backfilling, and Compaction for Utilities Cast-in-place Concrete.

Minimum Sample and Test Requirements (MSTR)

WQ-06 SAND FILTER. 1.0 Sand Filter. Greenville County Technical Specification for: 1.1 Description

Transcription:

3.33' 3.0' 2.0' 4.33' 4.0' 3.0' 1.00' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN NEENAH CASTING R-3067-V OR AS NOTED ON PLANS. "INFA-SHIELD" SEAL OR EQUAL. RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR). PLASTER OUTSIDE, STRIKE INSIDE CLEAN. VARIES 6" 24" 27" PRECAST SECTION. (WHEN NECESSARY, 8" SOLID CONCRETE BLOCK SHALL BE USED. PLASTER OUTSIDE WITH 1/2" MORTAR). 6" PRECAST- 8" POURED SLOPE INVERT TO PROVIDE SMOOTH OUTLET. 10/17/11 CATCH BASIN ST-1 CATCHBASIN.dwg

3.33' 3.0' 2.0' 4.33' 4.0' 3.0' 1.00' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN "INFA-SHIELD" SEAL OR EQUAL. NEENAH CASTING R-3067-V OR AS NOTED ON PLANS. RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR). PLASTER OUTSIDE, STRIKE INSIDE CLEAN. VARIES 6" 24" 27" PRECAST SECTION. (WHEN NECESSARY, 8" SOLID CONCRETE BLOCK SHALL BE USED. PLASTER OUTSIDE WITH 1/2" MORTAR). 3' 6" PRECAST- 8" POURED 2/24/15 CATCH BASIN WITH SUMP ST-2 CATCHBASIN WITH SUMP.DWG

MANHOLE LID RCP PIPE RCP PIPE SAFL BAFFLE INSTALL PER MANUFACTURER'S INSTRUCTION "INFA-SHIELD" SEAL OR EQUAL TOP VIEW ELEVATION (AS NOTED ON PLANS) ELEVATION (AS NOTED ON PLANS) RCP PIPE RCP PIPE ELEVATION (AS NOTED ON PLANS) 6'-0" 4'-0" MIN. BAFFLE HOLE SIZE AND PATTERN PER SAFL OR LICENSED DISTRIBUTOR ELEVATION (AS NOTED ON PLANS) PROFILE 12/15 BAFFLE STRUCTURE ST-3 BAFFLE STRUCTURE.dwg

BOTTOM OF RAIN GARDEN RIM ELEVATION AND TYPE AS PER PLAN MnDOT SPEC 3877 BEDDING MATERIAL. SOIL MEDIUM CONSISTING OF 70% SAND, 30% COMPOST. 12" 24" DIA. 12" MnDOT SPEC 3149.2H COARSE FILTER AGGREGATE. VARIES-SEE PLAN 6" PERMEABLE GEOTEXTILE FILTER FABRIC CONFORMING TO MNDOT SPECIFICATIONS 3733 TYPE V BETWEEN SOIL LAYER AND AGGREGATE BACKFILL (WRAP 1' ON EACH SIDE OF TRENCH) PERFORATED NYLOPLAST STRUCTURE 3/8" DIA. PERFORATIONS 6" O. C. VERTICAL @ 45 HORIZONTAL SECTION A-A 45 TYP TOP VIEW PERFORATED STRUCTURE ST-4 PERFORATED STRUCTURE.dwg

NOTES: 1. INSTALL TRASH GUARD ON ALL FLARED END SECTIONS 24" DIA. AND LARGER. 2. UNLESS OTHER FORM OF DISSIPATION IS REQUIRED, GRANITE RIPRAP WILL BE PLACED AROUND SIDES AND OVER TOP OF FLARED END SECTION. 3. ONE CUBIC YARD IS APPROXIMATELY 1.4 TONS. 2' A 1 4 B A PIPE DIA. (IN.) 12 15 18 24 30 36 42 48 >48 LENGTH (FT.) 8 8 10 12 14 16 18 20 22-28 QUANTITY (CY.) 5 5 6 8 12 14 22 26 30-40 CLASS 3 3 3 3 3 3 4 4 4 DIA. 2' 1 4 B 5D GRANITE RIPRAP 2' 12" NON-WOVEN GEOTEXTILE FABRIC EXTEND 1' UNDER FES. 12" GRANITE RIPRAP NON-WOVEN GEOTEXTILE FABRIC EXTEND 1' UNDER FES. DRT 12/2/15 RIPRAP PLACEMENT AT FLARED END SECTIONS ST-5 RIPRAP.dwg

160 HDPE PERFORATED PIPE 1/4" Ø HOLE TYPICAL 90 PERFORATED PIPE DETAIL ST-6 PERFORATED PIPE.dwg

NOTES: 1. GRADING OF THE INFILTRATION AREAS SHALL BE ACCOMPLISHED USING LOW IMPACT EARTH MOVING EQUIPMENT TO PREVENT COMPACTION OF THE UNDERLYING SOILS. STABILIZE AS NOTED ON PLANS OR AS DIRECTED BY ENGINEER MnDOT SPEC 3877 BEDDING MATERIAL. SOIL MEDIUM CONSISTING OF 80% SAND AND 20% COMPOST. PERMEABLE GEOTEXTILE FILTER FABRIC CONFORMING TO MNDOT SPECIFICATIONS 3733 TYPE II BETWEEN SOIL LAYER AND AGGREGATE BACKFILL (WRAP ON SIDES AND TOP OF TRENCH ONLY) VARIES VARIES (AS NOTED ON PLANS) MnDOT SPEC 3245 PERFORATED PIPE WITHOUT FILTER SOCK. (PIPE SIZE AND TYPE NOTED ON PLAN). SCARIFY BOTTOM OF TRENCH PRIOR TO BACKFILLING MnDOT SPEC 3149.2H COARSE FILTER AGGREGATE. PERFORATED PIPE TRENCH.dwg PERFORATED PIPE TRENCH DETAIL ST-7

3' 8" 4' 1" CONCRETE APRON 1' 6" 12% 5% CURB CUT (WIDTH VARIES) TAPER CURB TO MATCH TOP OF STRUCTURE CURB CUT APRON GUTTERLINE PLAN VIEW RAIN GUARDIAN TURRET INLET GRATE 12% 5% 6" 4" 1' 10 1/2" 1' 3 1/2" COMPACTED SUBSOIL CLASS 5 AGGREGATE BASE SECTION VIEW RAIN GUARDIAN TURRET CONCRETE BASE (INCLUDED) 10/17/11 12/15 RAIN GUARDIAN TURRET ST-8 RAIN GUARDIAN.dwg

NOTES: 1. INSTALL TRASH GUARD ON ALL FLARED END SECTIONS 24" DIA. AND LARGER. 2. UNLESS OTHER FORM OF DISSIPATION IS REQUIRED, GRANITE RIPRAP WILL BE PLACED AROUND SIDES AND OVER TOP OF FLARED END SECTION. SEE DETAIL ST-13. PROVIDE 3 ANCHOR CLIPS TO FASTEN TRASH GUARD TO FLARED END SECTION. HOT DIP GALVANIZE AFTER FABRICATION. 24" MAX. 6" TIE LAST THREE PIPE JOINTS ON INLET AND OUTLET PIPES AND BED GRANULAR MATERIAL. USE 2 TIE BOLT FASTENERS PER JOINT. INSTALL AT 60 FROM TOP OR BOTTOM OF PIPE. USE 5 8" TIE FOR PIPE SIZES 24" TO 27". USE 3 4" TIE FOR PIPE SIZES 30" TO 66". USE 1" TIE FOR PIPE SIZES 72" OR LARGER. NUTS AND WASHERS NOT REQUIRED ON PIPE SIZE LESS THAN 24". DRT 12/2/15 FLARED END SECTION ST-9 FLARED END SECTION.dwg

GALVANIZED GRATE IN 2 SECTIONS PS48-58H MANUFACTURED BY HAALA INDUSTRIES OR EQUAL. RCP BARREL SECTION 4' ELEV.??? 6" 6" ELEV.??? 6" PRECAST SLAB STANDARD OVERFLOW STRUCTURE WITH GRATE ST-10 STANDARD OVERFLOW STRUCTURE.dwg

NOTES: 1. GRADING OF THE INFILTRATION AREAS SHALL BE ACCOMPLISHED USING LOW IMPACT EARTH MOVING EQUIPMENT TO PREVENT COMPACTION OF THE UNDERLYING SOILS. 2. SEED OR SOD INFILTRATION AREAS AS DIRECTED BY THE ENGINEER. IF SEEDED, COVER SEED WITH S150 BN BLANKET. ADD STEEL EDGING TO PERIMETER OF RAIN GARDEN IF PLANTINGS ARE PROPOSED 3:1 MAX. 12" 3:1 MAX. MnDOT SPEC 3877 BEDDING MATERIAL. SOIL MEDIUM CONSISTING OF 70% SAND AND 30% COMPOST. VARIES COARSE WASHED SAND OR AS NOTED ON PLANS. 12/15 RAIN GARDEN DETAIL ST-11 RAINWATER GARDEN.dwg

NOTES: 1. GRADING OF THE INFILTRATION AREAS SHALL BE ACCOMPLISHED USING LOW IMPACT EARTH MOVING EQUIPMENT TO PREVENT COMPACTION OF THE UNDERLYING SOILS. 2. SEED OR SOD INFILTRATION AREAS AS DIRECTED BY THE ENGINEER. 12" 6" MnDOT SPEC 3877 BEDDING MATERIAL. SOIL MEDIUM CONSISTING OF 70% SAND AND 30% COMPOST. 24" PERMEABLE GEOTEXTILE FILTER FABRIC ON TOP AND SIDES ONLY. CONFORMING TO MNDOT SPECIFICATIONS 3733 TYPE II BETWEEN SOIL LAYER AND AGGREGATE BACKFILL (WRAP 1' ON EACH SIDE OF TRENCH) VARIES 6" VARIES - SEE PLANS MnDOT SPEC 3245 PERFORATED PIPE WITHOUT FILTER SOCK. (PIPE SIZE NOTED ON PLAN). MnDOT SPEC 3149.2H COARSE FILTER AGGREGATE. SCARIFY BOTTOM OF TRENCH BIOFILTRATION TRENCH DETAIL ST-12 BIOFILTRATION TRENCH.dwg

6" NOTES: 1. GRADING OF THE INFILTRATION AREAS SHALL BE ACCOMPLISHED USING LOW IMPACT EARTH MOVING EQUIPMENT TO PREVENT COMPACTION OF THE UNDERLYING SOILS. 2. SEED OR SOD INFILTRATION AREAS AS DIRECTED BY THE ENGINEER. IF SEEDED, COVER SEED WITH S150 BN BLANKET. ADD STEEL EDGING TO PERIMETER OF RAIN GARDEN IF PLANTINGS ARE PROPOSED REPLACE TOPSOIL (6" MIN), SEED & MULCH GRADED AREAS OUTSIDE PLANTING AREA SEED MIXED NOTED ON PLANS OR BY ENGINEER. SEE PLAN 6" TO 12" DEPTH TO OVERFLOW 36" DEEP INFILTRATION MEDIA, 80% SAND/ 20% LEAF COMPOST IN PLANTING AREA (SEE NOTES) 3 1 MAX. SLOPE LOOSEN/SCARIFY BOTTOM OF BASIN 12" PRIOR TO SOIL PLACEMENT (INCIDENTAL) NON WOVEN GEOTEXTILE FABRIC 4" ID DUAL-WALL CPEP (3247) W/ SLITS, NO SOCK. ENCASE IN COARSE FILTER AGGREGATE ( 1 4" TO 1 2" PEA ROCK), 4" ALL SIDES 12/15 BIOFILTRATION BASIN ST-13 BIOFILTRATION BASIN.dwg

NOTES: 1. SEED, SOD OR BLANKET BASIN AS DIRECTED BY THE ENGINEER. IF SEEDED, COVER SEED WITH S150 BN BLANKET. ADD STEEL EDGING TO PERIMETER OF RAIN GARDEN IF PLANTINGS ARE PROPOSED REPLACE TOPSOIL (6" MIN), SEED & MULCH GRADED AREAS OUTSIDE PLANTING AREA SEE PLAN 6" TO 12" DEPTH TO OVERFLOW 36" DEEP ENGINEERED SOIL, 80% SAND/ 20% LEAF COMPOST IN PLANTING AREA 3 1 MAX. SLOPE 1.5' EPDM LINER NON WOVEN GEOTEXTILE FABRIC 4" ID DUAL-WALL CPEP (3247) W/ SLITS, NO SOCK. ENCASE IN COARSE FILTER AGGREGATE ( 1 4" TO 1 2" PEA ROCK), 4" ALL SIDES 04/16 BIOFILTRATION BASIN WITH LINER ST-14 BIOFILTRATION BASIN WITH LINER.dwg

PVC SCREW CAP (2" ABOVE FINISHED GRADE) SOLID STANDPIPE (NON-PERFORATED SCHEDULE 40 PVC, 4" MIN.) USE 45 WYE AND FITTING OR EQUIVALENT TO CONNECT UNDERDRAIN TO STANDPIPE. SOLID PIPE PERFORATED PIPE WATERTIGHT PVC CAP ON UPSTREAM END OF UNDERDRAIN DRT 06/16 DRAINTILE CLEANOUT ST-15 DRAINTILE CLEANOUT.dwg

17.25" 14.5" 8" 0.75" 4" 8" CAST IRON FRAME AND COVER PVC SCREW CAP (SET AT GRAVEL GRADE) SOLID STANDPIPE (NON-PERFORATED SCHEDULE 40 PVC, 4" MIN.) USE 45 WYE AND FITTING OR EQUIVALENT TO CONNECT UNDERDRAIN TO STANDPIPE. EXISTING OR NEW CONCRETE OR BITUMINOUS - DEPTH VARIES WATERTIGHT PVC CAP ON UPSTREAM END OF UNDERDRAIN SOLID PIPE PERFORATED PIPE 12/20/17 DRT 12/20 DRAINTILE CLEANOUT WITH COVER.dwg DRAINTILE CLEANOUT WITH COVER ST-16

PROVIDE 6-1 2" SS ANCHOR BOLTS WITH CLIPS 1 1 2" x 3 8" STEEL OUTER RING 1 1 2" x 3 8" STEEL BARS AT 4" O.C. 1 4" x 1 4" STEEL BAR, WELD TO EACH MEMBER HOT DIPPED GALVANIZED GRATE IN 2 SECTIONS 4' 6" 2' EL. VARIES 1' RCP BARREL SECTION EL. VARIES EL. VARIES - HDPE OR RCP PIPE BOTTOM OF V-NOTCH ELEV - VAIRES (HDPE) 6" EL. VARIES - 1' SUMP STANDARD OVERFLOW STRUCTURE WITH V-NOTCH WEIR ST-17 STANDARD OVERFLOW WEIR STRUCTURE.dwg

GALVANIZED GRATE IN 2 SECTIONS PS48-58H MANUFACTURED BY HAALA INDUSTRIES OR EQUAL. 4' EL. 925.15 1' NYOPLAST ENVIROHOOD EXISTING 15" RCP 6" ORIFICE EL. 920.69 6" 3' 6" EL. 917.69-3' SUMP OVERFLOW STRUCTURE WITH ORIFICE ST-18 OVERFLOW STRUCTURE WITH ORIFICE.dwg

MANHOLE LID PIPE PIPE INSTALL BAFFLE PER MANUFACTURER'S INSTRUCTION TOP VIEW "INFA-SHIELD" SEAL OR EQUAL ELEVATION (AS NOTED ON PLANS) THE PRESERVER BAFFLE THE PRESERVER BAFFLE ELEVATION (AS NOTED ON PLANS) PIPE PIPE ELEVATION (AS NOTED ON PLANS) SEE PLAN SUMP ELEVATION (AS NOTED ON PLANS) PROFILE 3/17 BAFFLE STRUCTURE2.dwg BAFFLE STRUCTURE (PRESERVER) ST-19

CONCRETE CURB AND GUTTER POROUS PAVEMENT MIN. 3" THICK CHOKER COURSE 1"-3" THICK NON-CARBONIC (TYP. NO. 57 STONE) RESERVOIR LAYER - THICKNESS VARIES WITH DESIGN NON-CARBONIC GEOTEXTILE ON SIDES OF OPEN-GRADED BASE WITH 1' OVERLAP ON BOTTOM SOIL SUBGRADE 7/25/17 POROUS PAVEMENT DETAIL ST-20 POROUS PAVEMENT DETAIL.dwg

CONCRETE CURB AND GUTTER POROUS PAVEMENT MIN. 3" THICK CHOKER COURSE 1"-3" THICK NON-CARBONIC (TYP. NO. 57 STONE) RESERVOIR LAYER - THICKNESS VARIES WITH DESIGN NON-CARBONIC 2" NON-WOVEN GEOTEXTILE ON SIDES OF OPEN-GRADED BASE WITH 1' OVERLAP ON BOTTOM SOIL SUBGRADE DRAINTILE WITH NO SOCK NOTES: 1. GUTTER PAN SHOULD HAVE NEGETIVE SLOPE TO DRAIN INTO POROUS PAVEMENT 7/25/17 POROUS PAVEMENT WITH UNDERDRAIN.dwg POROUS PAVEMENT DETAIL WITH UNDERDRAIN ST-21

NEENAH CASTING R-3067-V OR AS NOTED ON PLANS. "INFA-SHIELD" SEAL OR EQUAL. HIGH DENSITY POLYETHYLENE (HDPE) ADJUSTMENT RINGS. MINIMUM OF 2", MAXIMUM OF 12", BONDED TO THE STRUCTURE, CASTING AND EACH OTHER BY APPROVED SEALANT. NEENAH CASTING R-1733 OR PLAN SPECIFIED "INFA-SHIELD" SEAL OR EQUAL. HIGH DENSITY POLYETHYLENE (HDPE) ADJUSTMENT RINGS. MINIMUM OF 2", MAXIMUM OF 12", BONDED TO THE STRUCTURE, CASTING AND EACH OTHER BY APPROVED SEALANT. 3/08/18 CATCH BASIN AND MANHOLE ADJUSTMENT RINGS ST-22 CB AND MH ADJ RINGS.DWG

12" TO 18" SUMP GRANITE RIPRAP CLASS 3 2' MnDOT CAT. 4, TURF REINFORMENT MAT MATCH EXISTING GROUND 6' FLAT BOTTOM CROSS SECTION 4:1 SLOPES 9" ROUGH CUT 6" FINAL DEPTH C125 BN 2" AMENDED SOIL AND SEED TRM - CAT. 4 SWALE DETAIL DRT 12/2/15 DRAINAGE SWALE AND BERM ST-23 DRAINAGE SWALE AND BERM.DWG

EXISTING GROUND BACKFILL TRENCH WITH CLEAN FILL MATERIAL 10 MIL PLASTIC LINER MATERIAL VARIES PIPE SIZE AND TYPE NOTED ON PLAN VARIES (AS NOTED ON PLANS) CONTAMINATED SOIL TRENCH.dwg CONTAMINATED SOIL TRENCH DETAIL ST-24