ASSESSMENT OF BIOAEROSOL DISTRIBUTIONS IN MUNICIPAL SOLID WASTE TRANSFER STATION

Similar documents
THE EFFECT OF DUCT CLEANING ON INDOOR AIR QUALITY IN OFFICE BUILDINGS

Bioaerosols Associated with Biomass to Energy - Worker Exposure and Health Hazards

MICROBIO BIOAEROSOL SAMPLING

Assessing Exposures to Compost Workers from Airborne BioHazards

AIR QUALITY IN SWINE-FINISHING BARNS 1

OPERATING MANUAL. Model 900

Bioaerosol emissions from waste composting and recycling

The attached report is the result of a mold and bacterial assessment conducted at th Street, Franklin, Ohio on April 24 and 25, 2008.

AIR HYGIENE TEST SUITABLE FOR ALLERGIC PEOPLE

Microgen and Airocide Technology as a Method for Sterilization in ICU: A Comparative Study

A FIELD COMPARISON OF METHODS FOR ENUMERATING AIRBORNE FUNGAL BIOAEROSOLS

APPENDIX 13.2 A. Immunoassay. Fluorescent immunoassay. Enzyme immunoassay (ELISA) Radio immunoassay (RAST)

UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL CLEANROOMS

AN INVESTIGATION ON THE OCCURRENCE OF FUNGI AND BACTERIA IN THE MVAC SYSTEM IN AN OFFICE PREMISE

CONCENTRATIONS OF PARTICULATE MATTERS(TSP, PM 10, PM 2.5, AND PM 1 ) AND BIOAEROSOL IN THE ABOVE- AND UNDER-GROUND SUBWAY OFFICES IN SEOUL

NCCEH Mould Investigation Toolkit

A L A R A Environmental Health & Safety Ltd.

MVOC EMISSIONS FROM FUNGI IN HVAC SYSTEM

MICROBIO BIOAEROSOL SAMPLING

Field Performance of Portable Impactors when Enumerating Viable Bioaerosols

INTRODUCTION: METHODOLOGY: November 4, Mr. Tom Heinz 353 West Sawgrass Dakota Dunes, SD 57049

Levels of Gram-Negative Bacteria, Aspergillus fumigatus, Dust, and Endotoxin at Compost Plants

Sioutas Cascade Impactor

UBC Social Ecological Economic Development Studies (SEEDS) Student Report

Exercise 13 DETERMINATION OF MICROBIAL NUMBERS

INTRODUCTION: METHODOLOGY: November 11, Mr. Tim Squier 487 Deerfield Dakota Dunes, SD 57049

VIRIDOR WASTE MANAGEMENT LIMITED. Lostock Waste Treatment Plant. Appendix 3 Bioaerosol Risk Assessment. November 2009

INTERPRETING MICROBIAL MEASUREMENT AND ANALYSIS

Sioutas Cascade Impactor

Spatial and temporal modelling of bioaerosols from intensive agricultural facilities in England

Notes on Indoor Air Quality

MICROBIAL MEASUREMENTS AT VENTILATION SYSTEMS SUPPLY VENTS

SUMMARY OF OUR FINDINGS

THE EFFECT OF INTENSIVE VACUUMING ON INDOOR PM MASS CONCENTRATION

8. Exposure scenario 8: Use at industrial sites - Plating processes in surface treatment

AIR QUALITY ASSESSMENT FOR TAYLOR STANLEY MARKETING PTE LTD 71, TANNERY LANE #-7-07, CITY INDUSTRIAL BUILDING SINGAPORE

EFFECTIVENESS OF PORTABLE AIR CLEANERS AND UPPER- ROOM ULTRAVIOLET GERMICIDAL IRRADIATION FOR INFECTION CONTROL

International Platinum Group Metal Association (IPA) Harmonised Methodology for the Sampling of Platinum in Workplace Atmospheres

According to our research and study most occupant complaints relating to IAQ are attributable to the following factors:

Laboratory and Field Evaluation of a New Methodology for the Sampling and Analysis of Fungal Fragments

AIRBORNE PARTICULATE MATTER WITHIN 100 RANDOMLY SELECTED OFFICE BUILDINGS IN THE UNITED STATES (BASE)

Q&As relating to the SAHSU study Exposures and health outcomes in. relation to bioaerosol emissions from composting facilities: A systematic

BIOAIRE CASSETTE Impaction Particle Sampler

BIO & PHARMA ANALYTICAL TECHNIQUES

Characteristics of the particulate matter in Riyadh city, Saudi Arabia

ART User Guide. Solid particles that are formed by aerosolization of already existing powders or by abrasion of solid objects.

School of Environmental & Resource, Inner Mongolia University, Huhhot, China

ANALYSIS OF FUNGI (MOLD) IN THE INDOOR ENVIRONMENTS BY DIRECT MICROSCOPIC EXAMINATION. (Analysis Code: FDE)

Which indoor air pollutants raise concern? How can indoor air quality be determined?

Pr oject Summar y. Reduction of foodborne pathogens on cattle during loading through control of dust generation

Technical Guidance Note (Monitoring) Environmental monitoring of bioaerosols at regulated facilities. Environment Agency January 2017 Version 1

EN ISO A more precise filter standard helps ensure air quality

Seasonal Variation of Airborne Microflora in Dairy Processing Plant

INDOOR AIR QUALITY TESTING AT CARLISLE COUNTY ELEMENTARY SCHOOL

EXPOSURE 4.1 EXPOSURE PATHWAYS. Water. Source of Contamination. Environmental Media

INDOOR AND OUTDOOR PARTICLE MEASUREMENTS IN A STREET CANYON IN COPENHAGEN

Effectiveness Of UVC Lights Irradiation To Improve Energy Saving

Indoor Air Quality Solutions

Industrial Hygiene. Introduction to Industrial Hygiene ENVIRONMENTAL SCIENCE

An Introduction to Air Sampling

A study of the characteristics of dust associated microorganism deposit in HVAC system

April 21, Dear Mike,

Sampling for particulates

CLEANLINESS REQUIREMENTS FOR VENTILATION DUCTS IN THE NEW FINNISH LABELING SYSTEM: PRACTICAL CONSEQUENCES

Sampling for particulates

16. Exposure scenario 16: Use at industrial sites - Use in biogas production

COMPARING THE ANTIMICROBIAL ACTIVITY OF THE SEMCO 3A TOTAL ENERGY WHEEL WITH OTHER SELECTED ANTIMICROBIAL SURFACE TREATMENTS RESEARCH FINDINGS

NCCEH Mould Investigation Toolkit

Occupational bioaerosol exposure in composting plants

Tissue Culture Sterilization and Contamination

Microorganisms In Our Environment

SAFETY DATA SHEET. Liquid and Vapor Applications (Purification, Decolorization, Separation, and Deodorization)

Test record CFU measurement. Test ID Site/Clinic Spijkenisse

RELATIONSHIP BETWEEN AIRBORNE MICROBIAL AND PARTICULATE MATTER CONCENTRATIONS IN THE AMBIENT AIR AT A MEDITERRANEAN SITE

CITY S, CITY M AIR PURIFIERS. Clean air solutions

Goal 2: Progress toward Advanced Energy Design Guides (AEDG) and cost-effective net-zero-energy (NZE) buildings.

AIR QUALITY. Providing high indoor air quality is a competitive advantage, not just an obligation. by John Reid, managing director, RoboVent

1. Product and company identification. 2. Hazards identification. Page No. 1. a) Product Name : D532

Influence of Different Cleaning Practices on Endotoxin Exposure at Sewage Treatment Plants

Employers Guide on How to Conduct A Worker Exposure Assessment for Silica

AIR AND SURFACE SAMPLING MEASUREMENTS OF FUNGAL CONTAMINANTS IN INDOOR ENVIRONMENTS

DEVELOPMENT OF AN INVESTIGATION METHOD FOR EVALUATION OF MICROBIOLOGICAL INDOOR AIR QUALITY

Method No.: 8.06/2.0/M Effective Date: January 4, 2012 Location: ###

MARCH BIOAEROSOL IMPACT ASSESSMENT AT KILMAINHAMWOOD

GRAIN Safety Data Sheet

ISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Biocontamination control Part 1: General principles and methods

Indoor Air Quality Assessments during Renovations at Waverly Elementary School Project #J (January 4, 12, 15, 25 and 29, 2018)

Determination of the microbial count

Indoor Air Pollution Monitoring

1204 North Road (Rt. 117) Groton, Connecticut 06340

Indoor Air Quality. Basic Management for Healthy Office Environments. Peter A Shelling CSP CIEC

The Design of Building and Services Affects Indoor Environments and Impacts Productivity

ORIGINAL PAPER. Jason M. Young & Timothy M. Kelly & Leonard Vance

Method 9.2 Drinking water and effluent: bacteria by the membrane filter method

Your family are threatened by harmful and hidden pollutants. Indoor air pollutant sources. WS907 NCCO Air Sanitizing System

To help protect your privacy, PowerPoint has blocked automatic download of this picture. Long Term Care Building Conference NOVEMBER 29,2013

Transcription:

ASSESSMENT OF BIOAEROSOL DISTRIBUTIONS IN MUNICIPAL SOLID WASTE TRANSFER STATION Vytautas Abromaitis Inga Urniežaitė Dainius Martuzevicius Kaunas University of Technology, Department of Environmental Engineering, Radvilėnų pl. 19, Kaunas, Lithuania ABSTRACT Operations in municipal solid waste (MSW) management chain are known to generate air pollution, especially with particulate matter. A significant portion of such pollution consists of bioaerosol particles, which potentially are harmful to human health. The presented research has aimed at assessing the emissions and seasonal fluctuations of total particulate matter and bioaerosol generated in MSW transfer facility. Aerosol samples have been collected every two weeks during the warm period of July and September. The samples have been collected by Button sampler on MCE filters. The concentration of total viable microorganisms has been determined by cultivation on Plate Count Agar. It was found that in the immediate vicinity of waste loading operations, the concentration of colony-forming microorganisms has reached 1 5 CFU/m 3, while outside the building, the concentration has decreased by a factor of ~1. Both particle and microorganisms concentration indoor/outdoor ratio has revealed high relationship indicating similar transfer mechanisms of particles to the outdoor environment. KEYWORDS Municipal Waste Management; Air pollution; Particulate Matter; Bioaerosol. INTRODUCTION Municipal solid waste (MSW) operations are usually associated with an excessive emission of particulate matter (PM) into ambient air. A biodegradable fraction of MSW constitutes up to 6% of total mass and serves as a favourable medium for the growth of various microorganisms. These biological particles are also released into ambient air during mechanical impact. The MSW-generated bioaerosol usually contains fungal spores and fragments, cells of bacteria, viruses, protozoa, secretion and fragments of insects etc. The bioaerosol particle size ranges from 1 to 1 m [1]. Recent studies have shown that workers at waste handling plants may have more gastrointestinal symptoms, irritation of the skin, eyes and throat, respiratory disorders including organic dust toxic syndrome (ODTS; toxic pneumonitis) than workers of the other occupations [2]. The knowledge of the cause of these health problems among workers is however limited. The occurrence of these symptoms is also known to be high in other work environments where the workers are exposed to high levels of bioaerosols, containing mould https://doi.org/1.15626/eco-tech.21.47 439

spores, bacteria and endotoxins. The intensity of exposure largely depends on the bioaerosol origin and composition, time of year, and the duration of waste storage and transfer [3]. In 1996, Niels O. Breum investigated the exposure to bioaerosols in waste collection. A comparative study on the significance of collection equipment, type of waste and seasonal variation was conducted. Generally the median exposure levels ranged from 1 5 to 1 6 cells/m 3 (total microorganisms), 1 4 to 1 5 CFU/m 3 (culturable fungi) and l 3 to 1 4 CFU/m 3 (culturable bacteria). The type of waste was a governing factor for exposure [3]. The assessment of airborne microorganisms in different types of waste handling has been done in 1999, in Finland. H. Kiviranta estimated that the concentrations of viable fungi were maximally 1 5 CFU/m 3, and the concentrations of both total culturable bacteria and Gramnegative bacteria exceeded the proposed occupational exposure limit values (OELV), being 1 4 and 1 3 CFU/m 3, respectively [4]. In 1995, E. Moller assessed the exposure of bioaerosols during collection of mixed household waste. On average, the exposure to total microorganisms during the working day was 5 1 5 CFU/m 3 of air for the worker mainly loading the waste into the compactor truck, while the truck driver was exposed to 1 5 CFU/m 3. Concentrations of dust and endotoxins in the air were low [5]. This study has aimed at determining levels of PM and viable microorganism concentrations in the MSW transfer station were an excessive aerolization occur due to inertial impact of falling waste. The temporal and spatial distributions of PM and microorganisms inside and near the transfer facility have been assessed. METHODS 2.1 Site description The MSW transfer station transfers approx. 15 tons MSW per year. The working area is 85 m 2. The station is of a direct waste transfer type, that is, the waste from smaller collection vehicles is transferred directly to a large container without storing it. Once the container is full, wastes are compressed and transferred to a landfill for a final deposition. The waste from collection vehicles is dumped into a shaft and freely falls 1 m to a large container. At this point, a significant amount of dust is released into the air. 2.2 Sampling and analysis The PM was sampled in two locations. One was situated inside of the station, with a distance of 1 m from the waste dumping shafts. Another location was situated outside of the building at a distance of 2 m from the vehicle entrance gate. Both sampling places were situated on a concrete floor surface. The scheme of sampling locations is presented in Fig. 1. Such sampling setup was selected in order to determine the dispersion of particulate matter and biological particles from the place of generation to the outside environment. All sampling procedures have been carried out during normal plant operations. The sampling campaign started in July and ended in September. The samples were taken in by-weekly intervals. The PM samples were collected by Button sampler (SKC Inc., PA, USA) on a mixed cellulose ester (MCE) filters of 25 mm diameter and a pore size of.8 m. The sampler was mounted on a supportive system consisting of a tripod and a rain-protective shield (Fig. 2). 44

(a) Figure 1. Scheme of MSW transfer station and sampler location: 1 MSW dumping shaft; 2 control room; 3 indoors sampling site; 4 outdoors sampling site; 5 transport moving route. Figure 2. Particulate matter sampling equipment: 1 personal pump; 2 polypropylene tube; 3 Button sampler; 4 rain shield; 5 tripod. The sampler s height was adjusted to 1.5 m from the floor level or ground surface, which approximately represents the breathing zone of a worker exposed to the dusts [6]. The sample air was drawn through the filter by personal sampling pumps (PCXR4, SKC Inc, PA, USA). The pumps were placed on a ground and connected with the sampler by 2 m long propylene tubes. The samples were taken with a flow rate of 4 lpm for 3 min period. Three subsequent samples were taken in each location, with the aim to quantify short-term temporal variation of PM and bioaerosol. After each run, the samplers have been thoroughly cleaned by a lint-free wipe soaked in a 96% ethyl alcohol solution. After a 2-hour sampling campaign, the filters have been immediately brought to the laboratory for the analysis. The collected PM samples were analysed gravimetrically and microbiologically. During the gravimetrical phase, the filters were kept at a constant temperature of 2 o C for 1 hour in order to stabilize their mass. The filters were weighed before and after each sampling with a microbalance of 1 μg precision (MX5, Radwag, Poland). After the gravimetric analysis, the microorganisms have been extracted from the MCE filters by submerging them into 15 ml of sterile water and shaking them for two minutes. Afterwards, the samples were ultrasonicated for 1 minutes. The combination of mechanical shaking and ultrasonication allows reaching 9-98% extraction efficiencies [7,8]. Afterwards, the extracts were diluted and plated-out into 9 mm Petri dishes filled with Plate count agar, which is usually used for the total viable counts. The prepared Petri dishes were thermostated for 72 hours in a temperature of 3 o C [9]. After such incubation, only the plates containing 3-3 colony forming units (CFU) were counted. The obtained results were re-calculated to CFU per 1 m 3 of air [6]. 441

In addition to the field samples, 1% of field an laboratory blank samples were processed and analysed in parallel by the above-described techniques, in order to control the quality of analyses. The obtained data was analyzed for temporal variation (both short-term and long-term) and spatial variation (inside/outside of the station). RESULTS AND DISCUSSION 3.1 Temporal variations of particulate matter concentrations The observed mass concentrations of PM are presented in Table 1. As expected, the PM concentrations observed inside of the transfer station were significantly higher than those observed outdoors (Wilcoxon matched pair test yielded a value of p<.5). A substantial temporal variation has been noticed both for indoor and outdoor sampling locations. The concentration ranged from 3,975±72 to 17,94±3,878 g/m 3 inside of the station, and from 432 to 2,498 g/m 3 outside. The short term variation, expressed by the coefficient of variation (CV) ranged from 1.8 to 43.6 % inside of the station, 8.3 to 48.9 % outside of the station. This relatively high variation may be easily explained, since during three subsequent 3 min samples, the emission of particles varies substantially due to ongoing waste transfer operations. The long term variation was also rather high, reaching 64.4% inside of the station and 74.2% outside of the station. Similar levels of long-term temporal variation indicated possible dependences of outdoor to indoor concentrations, although no clear relationship has been registered (as discussed in 3.3 sub-section). The comparison of data obtained in this study to earlier studies has revealed that in our case observed PM concentrations reached up to 12-fold higher levels. The maximum reported concentration reached 15 g/m 3 [3,1], while we have registered maximum concentration of 1794 g/m 3. This might have been caused by an event of transfer of dusty waste, such as a presence of construction/demolition waste in the load. The long-term threshold limit value of the exposure to PM in workplace environment in Lithuania is 5 g/m 3, thus inside of the station it is exceeded by an average of 1.7 times. At the same time, concentrations of PM outside of the station were 3.8 times lower. Table 1. PM concentrations registered inside and outside of transfer station (mean±standard deviation) PM, g/m 3 Outdoors 7/15/21 7/27/21 8/12/21 8/27/21 9/17/21 Average 8,73 ±634 2,498 ±211 17,94 ±3878 432 ±36 6,644 ±2,898 616 ±31 3,975 ±72 781 ±215 5,546 ±237 2,229 ±334 8,567 ±5,518 1,311± 973 3.2 Temporal variations of bioaerosol concentrations The measured concentration of bioaerosols, expressed as viable counts, similarly to PM concentrations, was also significantly higher indoors (p<.5). Inside of the station the concentration ranged from 248,413±139,531 to 619,48±78,68 CFU/m 3, and outside from 2,952±274 to 51,587±4764 CFU/m 3. The short-term variation represented by CV ranged 442

from 12.7 to 56.2 %, and 9.2 to 42.4%, respectively. The long-term CV for inside and outside was rather similar: 43.4 and 42.1%, respectively. These findings correspond rather well with the results of PM measurements. On the other hand, the long-term variation was somewhat lower than that of PM. The measured concentrations of airborne viable microorganisms were of the comparable level to the studies in similar environments. The concentrations inside of the transfer station were of 1 5 CFU/m 3, while outside of the building they varied around 1 4 CFU/m 3. Heldal et al. (1997) have determined the concentrations of 1 4 1 6 CFU/m 3 in the source-separated waste sorting facility [1]. Table 2. Biological particle concentrations registered inside and outside of transfer station (mean±standard deviation) Total 293,651 viable ±97,192 counts, CFU/m 3 Outdoors 2,952 ±2,74 7/15/21 7/27/21 8/12/21 8/27/21 9/17/21 Average 619,48 ±78,68 22,937 ±5,545 256,349 ±52,669 23,95 ±2,52 475,397 ±85,61 51,587 ±4,764 248,413 ±139,531 38,81 ±7,19 378,572 ±163,15 31,476 ±13,343 There are no internationally accepted threshold limit values (TLVs) or occupational exposure limits (OELs) for microorganisms [2]. It has been proposed that fungal and bacterial concentrations, which are higher than 1 4 CFU/m 3 should be considered as a threat to worker s health [11]. Moreover, it was shown that symptoms in the eyes and nose increased after exposure to fungal spores at the level 2 1 4 to 5 1 5 /m 3 and cough symptoms after exposure to concentrations of 5 1 5 to 17 1 5 fungal spores/m 3 [12]. In our study, the observed levels inside the municipal solid waste transfer station reached up to 1 5 CFU/m 3, while in near vicinity of the station, the concentrations have decreased to the level of 1 4 CFU/m 3. This indicates that working conditions inside of the transfer station are of elevated hazard. 3.3 Indoor to outdoor distributions of particulate matter and bioaerosol The obtained data of PM and microorganisms concentrations inside and outside of waste transfer station building have been analyzed with respect to relationships between indoor and outdoor concentrations as well as relationships between PM and microorganism concentrations. It was hypothesized that due to strong emission source, the relationships should exist between indoor and outdoor particle concentration, and between PM and bioaerosol concentrations. Figure 3 shows relationships of indoor and outdoor concentrations of PM and viable microorganisms. It is evident that based on the collected data, a clear and significant relationship in both cases cannot be established (Spearman r equalled -.14 for PM and -.9 for microorganisms, p<,5). It must be admitted that the amount of collected data is rather low to establish statistically significant relationships. We expect to continue the collection of data to obtain larger data sets for more representative conclusions. The next step of the data analysis led to the establishment of relationships between two types of measured particles indoors and outdoors (Figure 4). Rather strong relationship has been 443

established between PM concentration and microorganisms concentration inside of the building (R 2 =.45). There was a single occasion of high microorganism concentration; having removed this point from the analysis, the value of R 2 of.95 was reached. Thus, the data indicates that it is possible to build a forecast model of rather high accuracy for predicting emission of microorganisms based on only PM mass measurements near a source. On the other hand, further from the source (outside), no relationship between concentrations of PM and microorganisms could be established (Spearman r =-.2). (a) 3 PM concentration, μg/m 3 (b) 6 Total viable counts, CFU/m 3 Outdoors 2 1 Outdoors 4 2 5 1 15 2 25 2 4 6 Figure 3. Indoor/outdoor relations of particulate matter concentration (a) and total viable counts (b) (a) (b) 6 Outdoors Total viable counts, CFU/m 3 6 4 2, Total viable counts, CFU/m 3 4 2 5 1 15 2 25 1 2 3 PM concentration, μg/m 3 PM concentration, μg/m 3 Figure 4. The relationship between total viable counts (CFU/m 3 ) and particulate matter concentrations (g/m 3 ) at the indoors (a) and outdoors (b) of MSW transfer station 444

5 4 y =.4565x + 7.7563 R 2 =.8782 Total viable counts (Indoor/Outdoor ratio) 3 2 1 1 2 3 4 5 PM (Indoor/Outdoor ratio) Figure 5. The relationship between total viable counts and PM indoor/outdoor ratios The above described distributions indicated that although there is no clear relationship between PM and microorganism indoor/outdoor concentration, indoor/outdoor ratios may actually be associated. Figure 5 shows such relationship with a relatively high R 2 value. It maybe concluded that both physical and biological particles are dispersed by the same mechanism (such as ventilation, movement of vehicles etc.). CONCLUSIONS The experimental investigation of distributions of airborne particulate matter and viable microorganisms in the municipal waste transfer station has revealed both high temporal and spatial variability of the two types of particles. High temporal variability was associated with rapidly fluctuating operations within the facility, as well as properties of waste that was transferred. At the same time, it was noticed that the generation of viable microorganisms is associated with generation of particulate matter close to the waste transfer shafts. The indoor/outdoor distribution analysis has revealed that both mechanical and biological particles are being transported to the outdoor environment by the same mechanisms, although no clear relationship between outdoor and indoor concentrations of PM and bioaerosol has been established. The measured indoor concentration of PM was up to 4 times, and of bioaerosol up to 25 times higher than outdoors. REFERENCES [1] Vincent J. H. Aerosol sampling: science, standards, instrumentation and applications. (27). John Wiley & Sons, 473. [2] Madsen A. M. (26). Exposure to Airborne Microbial Components in Autumn and Spring During Work at Danish Biofuel Plants. Annals of Occupational Hygiene, 8, 821 831. [3] Nielsen E. M., Breum N. O., Nielsen B. H., Würtz H., Poulsen O. M., Midtgaard U. (1996). Bioaerosol exposure in waste collection: a comparative study on the significance of collection equipment, type of waste and seasonal variation. Annals of Occupational Hygiene, 3, 325-344. [4] Kiviranta H., Tuomainen A., Reiman M., Laitinen S., Nevalainen A., Liesivuori J. (1999). Exposure to airborne microorganisms and volatile organic compouonds in 445

different types of waste handling. Annals of Agricultural and Environmental Medicine, 6, 39-44. [5] Moller E., Nielsen B. H., Breum N. O. (1995). Occupational bioaerosol exposure during collection of household waste. Annals of Agricultural and Environmental Medicine, 2, p. 53-59. [6] ASTM, (21). Standard practice for sampling airborne microorganisms at MSW processing facilities. [7] Lee T., Grisphun A. S., Martuzevičius D., et. al. (26). Culturability and concentration of indoor and outdoor airborne fungi in six single-family homes. Atmospheric environment, 4, 292 291. [8] Lee T., Grisphun A. S., Martuzevičius D., et. al. (26). Relationship between indoor and outdoor bioaerosols collected with a button inhalable aerosol sampler in urban homes. Indoor air, 16, 37-47. [9] Jensen A. P., Schafer P. M. (1994). Sampling and characterization of bioaerosols. New York, 84 112; [1] Heldal K., Eduard. W, Bergum M. (1997). Bioaerosol exposure during handling of source separated household waste. Annals of Agricultural and Environmental Medicine, 4, 45-51. [11] Heida H., Bartman F., Van der Zee S. (1995). Occupational exposure and indoor air quality monitoring in a composting facility. American Industrial Hygiene Association, 56, 39 43. [12] Eduard W., Douwes J., Mehl R., et. al. (21). Short term exposure to airborne microbial agents during farm work: exposure-response relations with eye and respiratory symptoms. Occupational and Environmental Medicine, 58, 113-8. 446