SIKA EGYPT ENG. HOSSAM ABD ELMAGIED SPECIFICATION DEPARTMENT DEC. 2016

Similar documents
TILING SIKA TILE INSTALLATION SYSTEMS

Specialities, Assuring Clients of Consistently High Standards Within Record Time Frames.

Sika India Private Limited

MasterSeal Roof systems. Solutions for all your roofing needs

Waterproofing Systems Liquid Applied.

Waterproofing Systems

WATERPROOFING MATERIALS

SMARTCARE DAMP PROOF TECHNICAL PARAMETERS

RECTIFICATION OF WATERPROOFING IN AGED SWIMMING POOLS ON ROOFTOPS & ABOVE CAR PARKS WITH FRP. Jeda Pte Ltd Tel:

Wind Turbine Technologies. Sika Wind Turbine Technologies Imagine New Solutions. Renewable Energies_1

Waterproofing Systems for Wet areas

Contact Adhesive, Adhesive Paste

LightBUILD Lightweight Cellular Insulating Concrete As a choice for New Roof Decks Construction and Reroofing Applications

Aquaflex. Roof Plus. Ready-to-use, high-elasticity, quick-drying, UV-resistant liquid waterproofing membrane PI-MC-IR

SMARTCARE P U M A G N U M

Current Developments in Pre-Applied and Post- Applied Waterproofing of Concrete. Presented by. Kobus Botma

1. Section 04300: Concrete Masonry Units

WATERPROOFING OF AN ACCESSIBLE FLAT ROOF WITH A POLYURETHANE LIQUID MEMBRANE AND TILING

MAPEI PRODUCTS FOR INSTALLING STONE MATERIAL

1-part polyurethane pourable self levelling floor joint sealant

PRODUCT DATA SHEET Sikaflex PRO-3 WF

SIKA WET ROOM SYSTEM WATERPROOF. WORRY PROOF.

WATERPROOFING CONSTRUCTION JOINTS

PIONEER for Specialized Contracting & Trading ( P.S.C.T.)

TECHNICAL DATA SHEET SIKAFLEX PRO-3 SELF LEVELLING

MINING SOLUTIONS YOUR COMPETENT AND DEDICATED PARTNER

PRODUCT DATA SHEET Sikalastic -501 Roofseal Plus

SELF-ADHESIVE MEMBRANES

Waterproofing construction Joints

Continuous and union-free hybrid polyurea hot-sprayed liquid membrane for more demanding waterproofing, protection and sealing works.

TECHNICAL DATA SHEET SIKAFLEX FLOOR

2013 Product Catalogue

WIND TURBINE TECHNOLOGY IMAGINE NEW SOLUTIONS

imperbox Waterproofing imperbox Waterproofing Recommended use: Features: Materials: Coverage: Angles and waterproof bands: Substrates: Packaging

MEMBRANE WATER PROOFING. Our Services: Below ground waterproofing, Above-ground waterproofing, Wet Areas Waterproofing, Joint Sealants.

SIKA ROOFING SOLUTIONS FOR NEW CONSTRUCTIONS AND REFURBISHMENTS

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

When Quality and Delivery meet pricing and commitment, this is what we excel at

1-part elastic joint sealant and multipurpose adhesive

Construction. 1-part elastic joint sealant and multipurpose adhesive. Product Description

Sealing and decoupling. Things to know and technology

ONE COMPONENT ALIPHATIC POLYURETHANE COATING

1-part elastic joint sealant and multipurpose adhesive

PRODUCT DATA SHEET Sikalastic Rapid-721

FLOORING NEW Sikafloor MultiFlex RANGE FOR CAR PARKS THE POWER FORMULA FOR THE MOST ROBUST COATINGS

PRODUCT DATA SHEET Sika Level-315 F

WATERPROOFING SikaProof FULLY BONDED MEMBRANE SYSTEMS FOR WATERTIGHT BASEMENTS TECHNOLOGY & SYSTEMS

1-part elastic joint sealant and multipurpose adhesive

Incozol BH Aldimine Latent Curing Agent

SEALING & BONDING SIKA FIRE PROTECTION SOLUTIONS

CEMENTITIOUS FLOOR FINISH

Construction. Sika Services AG. Sika Services AG. Sikafloor reactive resin systems

Waterproofing Systems. Cementitious.

ThermaSheet. multi-purpose insulated tile backer panels

Sikalastic -632 R REACTIVE PURE POLYURETHANE WATERPROOFING MEMBRANE

One-part High Performance Sealant for Flooring

1-part elastic joint sealant and multipurpose adhesive

TECHNICAL DATA SHEET SIKABOND AT METAL GREY 300CC

Single Source Comprehensive Warranty. ARDEX Americas. Swimming Pool Guide

Next Generation Liquid Applied Roofing Membrane

Pol-E-Base Modified Bitumen Roof System

Industrial Facilities & Infrastructure

1-part high performance sealant for flooring

SECTION CONCRETE TOPPING

GARDEN ROOF WITH THERMAL INSULATION TECHNICAL SPCIFICATIONS

POLYMER MODIFIED CEMENTITIOUS SYSTEMS

The System 10 Perfect design, robust and fast construction

DWS. ABP Spray applied liquid Waterproof ing and car park deck systems No Heat, No Flame, Reduced Risk Assessment

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

SealArm Tape TPE. Building & Joint Sealants T E C H N I C A L D A T A S H E E T. Uses. Features and Benefits

SELECTION CHART OF WATERPROOFING PRODUCTS

TECHNICAL SPECIFICATION FOR VARIOUS WATERPROOFING TREATMENT

Rubberized Asphalt Mastic and Coating

WATERPROOFING Flexible Waterproofing with Sika Membrane Technologies

MARINE DIRECT GLAZING SYSTEMS

MorTec DRAIN. MorTec DRAIN Page 1 of 4. Two-part thin-layer epoxy resin drainage mortar DESCRIPTION

Construction. Cementitious self levelling, fast hardening, underlayment for use 2-10mm, and 10-30mm with added aggregate. Product Description

Floor Screeds & Compounds

Waterproofing Products for UNDERGROUND STRUCTURES

Construction. Sika-Trocal SGmA 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

To broaden your awareness of waterproofing products and their installations, and emphasising its importance on your building site.

2 COMPONENT LIQUID WATERPROOFING PART 1 GENERAL. A. Two component liquid waterproofing for positive side waterproofing on mineral substrates

Flat roofs. Flat roof design. 2.3 Flat Roofs

Joint Sealants & Foam Fillers.

SEAMLESS DURABLE WATERTIGHT High Performance Structural Protection and Waterproofing

Sarnavap 5000E SA Vapour Control Layer

Polymeric membrane for roof waterproofing

WATERPROOFING SikaProof FULLY BONDED MEMBRANE SYSTEMS FOR WATERTIGHT BASEMENTS TECHNOLOGY & SYSTEMS

WATERPROOFING SIKA SOLUTIONS FOR POTABLE WATER

Total Parking Solutions: From Lowest or Basement Levels to Roof Top Decks

Finish for topped and smooth surfaces, with or without chips. Pore and cavity filler, joint filler, adhesive for tiles etc.

INSTRUCTIONS FOR INSTALLING LARGE FORMAT CERAMIC TILES

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

Insulation foils. with the home in mind

for the master tradesman Setcrete Product Guide

SUSTAINABILITY THROUGH TECHNOLOGY AIR & WINDTIGHT SYSTEMS

Perma Construction Aids Private Limited

Cool-R is one component, highly reflective, seamless, waterproofing coating for new and refurbished roofs. It can be use on flat and slope roofs.

Transcription:

SIKA EGYPT ENG. HOSSAM ABD ELMAGIED SPECIFICATION DEPARTMENT DEC. 2016

TARGET MARKETS Concrete Waterproofing Roofing Flooring Sealing & Bonding Refurbishment Industry 2 December 27, 2016

3 WATERPROOFING

PROJECT DESCRIPTION: Secon Towers project - located in El Maadi Kournish El Nile Cairo Egypt. The project consists of 3 multi-storey underground car park with an area that exceeds 16000 m2 near Nile River that makes the ground water table less than 4.50 m. Sika Solution: Sika proposed Sika compartment system that includes : - Sika Plan WP 1140-20HL as a PVC layer 2mm thick. as a flexible High tensile& elongation Waterproofing membrane sheets. - Sika Waterstop AR-31, AR-25 AND AR 20 High quality PVC Waterstop for long durability. 4 December 27, 2016Specification training 2016 / MLg

SECON TOWERS 5 December 27, 2016Specification training 2016 / MLg

6 December 27, 2016Specification training 2016 / MLg

NEW WATERPROOFING PRODUCTS : TOP SEAL 107 ELASTIC High elastic waterproofing Cement based Slurry. Capable of accommodating substrate flexural strains. Crack bridging capability. In thermal movements and vibrations. Optimum adhesion onto almost all substrates Uses : in different structures including those subjected to thermal movement and vibrations Hydraulic structure, terraces, Balcones and Precast concrete

ROOFING

MARASSI BEACH CLUB 9 December 27, 2016Specification training 2016 / MLg

Project Description - The Club house located in Marassi Project in North coast where there Is a heavy rain the winter cause a lot of Leakage on the roof - There is two different roofs in using, One is accessible which Sika suggested the Combo roof system in and the second is non-accessible which Sika suggested the Sika Lastic 560 system reinforced with Sika Lastic Fleece Requirements: - A durable System for roofing the Club house accessible roof - New innovation system for the non-accessible roofs - Easy maintain system which can be maintained easily - For the non-accessible areas they need a roofing system which can be used without removing the old tiles and Insulation - Fast application system 10 December 27, 2016Specification training 2016 / MLg

COMBO ROOF SYSTEM 11 December 27, 2016Specification training 2016 / MLg

SIKA INTEGRATED ROOFING SYSTEM ( COMBO ROOF) 1- Sika Topseal 107 Elastic 1 2- Screed in panels and Slopes 3- Separation Layer 4- Sika Raintite Acrylic Paint 5- SIKA PU foam Spray 6- Roof Slab WHY CHOOSE??? 1- Cost effectiveness: application, repair and maintenance is a seamless and easy process allowing long term investment. VID-20120426-00007.3GP 2- Double layered waterproofing system: due to its double layer of monolithic system and its closed cell construction in the foam forms an impermeable waterproofing layer. 3- Saving Energy: it is based on the latest PU technology keeping the heat out reducing the use of air conditions which in turn saves up to 40% in electricity bills 12

SIKA INTEGRATED ROOFING SYSTEM TECHNICAL EVALUATION AGAINST THE CONVENTIONAL SYSTEM SIKA INTEGRATED ROOFING SYSTEM Integrated Roofing System is offering comprehensive system by a single manufacturer BITUMEN MEMBRANE SYSTEM Non-availability of any comprehensive roofing system by single manufacturer - spray polyurethane foam with average density 50-55 Kg/m3 & thickness 4(±1) cm. Sika PU foam Spray - apply an acrylic UV protection waterproof coating sika Raintite - - lay a geotextile filter fabric over the roof area as a protection layer prior to the start of screeding works. - lay protective screed with average thickness 5cm making all required paneling work to attain the desired slope levels as well as sealant filling to all expansion joints (Sikaflex 1a). Apply Elastomeric cementitious coating sika topseal 107 elastic Heat Insulation and waterproofing joints free Provides a monolithic continuous surface with no edges, seams, gaps or joints. Offers best K-value 0.02w/mk means 3cm PU foam is equivalent to 5cm extruded polystyrene. - Install torch applied water proofing membrane making all required flashing. - lay polyethylene 1000g protective sheet on the membrane. - Install extruded polystyrene heat insulation boards with 7cm thickness. - Supply & lay a geotextile filter fabric over the roof area as a protection layer prior to the start of screeding works. - Supply & lay protective screed with average thickness 5cm making all required paneling work to attain the desired slope levels as well as sealant filling to all expansion joints (by others). 6- Elastomeric cementitious coating. Heat Insulation and waterproofing with joints Required to be cut & welded taking into consideration overhangs, overlaps, seams & joints. K-value 0.033 w/mk means 5cm extruded polystyrene is equivalent to 3cm PU foam.

SIKA INTEGRATED ROOFING SYSTEM TECHNICAL EVALUATION AGAINST THE CONVENTIONAL SYSTEM SIKA INTEGRATED ROOFING SYSTEM Self adhering without fasteners preventing water migration laterally under insulation if any damage occur. Self flashing Higher density 50-55 Kg/m3 means higher mechanical properties like compressive strength. Self adhering without fasteners resisting wind uplift problems. Excellent application for irregular surfaces such as corrugated, critical, inaccessible or curved areas. Rapid installation times BITUMEN MEMBRANE SYSTEM water migrates laterally under insulation if any damage occur making it very difficult to find or repair a leak. Mechanically Attached flashing Lower density 32 36 Kg/m3 means lower mechanical Properties. Mechanically Secured to roof with fasteners & can lift off under high wind. Only can be used on flat areas. Much more time needed especially in hard to treat areas. 14 December 27, 2016 Title of Presentation / Meeting Name

LIQUID APPLIED MEMBRANE ( SIKA LASTIC 560 ) 15 December 27, 2016Specification training 2016 / MLg

16 FLOORING

ARAB AMERICAN VEHICLES FACTORY AAV CAIRO SUEZ DESERT ROAD 17 December 27, 2016Specification training 2016 / MLg

Project description : - Arab American Vehicles Company (120,000 square meter) facility located on the out skirts of Cairo with a production capacity of 17,600 vehicles annually. Project requirements : 1. Petrol and oil resistant floor 2. Minimum maintenance 3. Cost effective solution 4. Fast completion in the shortest possible time 18 December 27, 2016Specification training 2016 / MLg

Photos from site 19 December 27, 2016Specification training 2016 / MLg

20 December 27, 2016Specification training 2016 / MLg

SYSTEM SPECS : - Primer : Sika Floor 161 - Epoxy Mortar ( 4 mm ) : Sika Floor 161 ( A+B+C ) - Self leveling ( 2-3 mm ) Sika Floor 263SL 21 December 27, 2016Specification training 2016 / MLg

JOINT SEALING Sikaflex supported by a Sika Rod joint base. Sikaflex SikaRod 22 D b 27 2016S ifi ti t i i 2016 /ML

REFURBISHMENT

RAGAB SCHOOL COMPLEX 24 December 27, 2016Specification training 2016 / MLg

RAGAB SCHOOL COMPLEX one of the newest educational projects in Alexandria, with a special design and theme. 3 Schools inside one big complex (50 000 m2 ) PROJECT REQUIREMENTS - Indoor and Outdoor Tile Adhesive for fixing tiles and Facades all over the school, Tiles are by Restic Tiles a new technology. PROJECT PARTICIPANTS: Consultant: EL Oraibi Architects Contractor : MASS, Abu Shabana Conc, EL Bishbichi Conc 25 December 27, 2016Specification training 2016 / MLg

Photos from site 26 December 27, 2016Specification training 2016 / MLg

TILE ADHESIVE: SIKA CERAM 205 LARGE (C2TE classified according to EN 12004) - SikaCeram -205 Large is one-pack, premixed adhesive consisting of high resistance cements, high polymers content, selected silicon/quartz mineral charges and specific additives. Suitable for laying in over-tiling, swimming pools, façade or heavy traffic environments. 27

3. TILE ADHESIVES 3.1 SPECIFIED CODE OR STANDARD EN ( European Norm) EN 12004 For Tile Adhesives EN 13888 For Grouting Material ANSI ( American National Standard Institute) ANSI 118.1-118.17 For Tile Adhesives and Grouting 28 December 27, 2016 Title of Presentation / Meeting Name

3. TILE ADHESIVES 3.1 NORMS Definition of types based on binder s chemical nature. C Cement-based binder D Dispersion of resins R Reactive binder Classes related to final performances as adhesion strength: 1 Normal 2 Improved (meets requirements for additional characteristics) Classes related to products workability features: F Fast (only for class C) T Thixotropic E Extended Open Time (only for class C and D) Classes related to Transversal deformation level (Only for type C) S1 deformable S2 highly deformable 29 December 27, 2016 General Overview

HOW TO KEEP IN TOUCH

WE ARE HERE FOR YOU - Sika Product finder application - Sika Egypt site - Sika Egypt Pages in social media : Facebook & Linked In & Twitter Or contact us directly : Specification team Sales team Technical support team 31 December 27, 2016Specification training 2016 / MLg

THANK YOU FOR YOUR ATTENTION