MANUFACTURER'S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE

Similar documents
MANUFACTURER S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) MASONRY [BLOCKS] [BRICKS] [STONE]

MANUFACTURER S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON HEMPCRETE

MANUFACTURER'S SPECIFICATIONS Section MASONRY REPOINTING AND RECONSTRUCTION

MANUFACTURER S SPECIFICATIONS Section LIMESTONE PLASTER

MANUFACTURER S SPECIFICATIONS SECTION EXTERIOR-INTERIOR LIME PLASTER

Conditions of the Contract and Division 1 General Requirements are a part of this section.

SECTION PORTLAND CEMENT PLASTERING

MONOBASE AAC/ SIDER-PLAST THE ULTIMATE EXTERIOR HARD COAT STUCCO SYSTEM FOR AUTOCLAVED AERATED CONCRETE

1.02 SUMMARY A. Section Includes: 1. Repair of two-coat historic exterior vertical plasterwork (stucco)

SECTION PORTLAND CEMENT PLASTER (STUCCO) WITH ACRYLIC FINISH

SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO SYSTEM

SECTION MORTAR

SPECIFICATION GUIDELINE

SECTION Fiber Reinforced Stucco 1

SPECIFICATION GUIDELINE

SECTION Arisfor WallGuard

Construction Standards PAGE

LaHabra Fastwall 100 AF over CMU Stucco Assemblies Specification

SECTION BRICK MASONRY ASSEMBLIES

SECTION GLASS UNIT MASONRY ASSEMBLIES

Product Guide Specification

SECTION MANUFACTURED MASONRY VENEER

MANUFACTURER S SPECIFICATIONS Section LIME CONCRETE. A. This section describes the requirements for floors and slabs on grade.

LaHabra Fastwall 300 WaterMaster AF over CMU Stucco Assemblies Specification

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

SECTION Specification for Building Limes Specification For Building Sands from Natural Sources Methods of Tests for Paints.

MASONRY MORTARING

Building Construction 14. Dr Nabil El-Sawalhi Associate professor Engineering Projects Management

SECTION BRICK FLOORING

SELECT APPROPRIATE SECTIONS FOR BELOW; DELETE OTHERS

SECTION UNIT MASONRY

ReCote Finish System over Concrete

SECTION UNIT MASONRY ASSEMBLIES

SUNY GENESEO RED JACKET DINING HALL RENOVATION THIN BRICK MASONRY

SECTION INSTALLATION AND/OR REPLACEMENT OF MASONRY UNITS AND REPOINTING

REINFORCED CONCRETE MASONRY SECTION

MANUFACTURER S SPECIFICATION

SECTION UNIT PAVERS

CSI SECTION MAINTENANCE OF CONCRETE Repair & Resurfacing with Rapid Hardening, High Strength, Low-Shrink, Non-Metallic Cementitious Materials

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MORTAR AND MASONRY GROUT

SECTION UNIT MASONRY

SECTION TILING

GigaCrete Specification PlasterMax. PlasterMax : Fire Rated Plaster for Direct Application over Cement Masonry Units (CMU) Interior Walls

Paragraph Description Page No General Materials Concrete Masonry Work Altitude Valve Vault Cover 25-4

CONCRETE TILE PAVERS

SECTION CEMENT BOARD SUPPORTED ADHERED MASONRY VENEER. 2. Installation materials including adhesives, mortars, and pointing mortars.

SECTION RIGID PAVEMENT

CONCRETE BALUSTRADE SYSTEM

RENOVATE BUILDING 18-C FTFA SECTION GYPSUM BOARD 05/11

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

Narrow Modular Pavers (NMP) for Sand-Set Installations

1. Repairing brick masonry, including replacing damaged units as indicated on drawings. 2. Repointing mortar joints.

3910 E. McKinney Denton, TX P.O. Box Dallas, TX EZ WALL CONCENTRATE, INC

PROGRAM COMMENT FOR DEPARTMENT OF DEFENSE REHABILITATION TREATMENT MEASURES

Section Shotcrete

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION ARCHITECTURAL CONCRETE UNIT MASONRY

EDGEWATER, FLORIDA JUNE 14, 2010

SECTION CAST-IN-PLACE CONCRETE

BRICKWORK 3.5 BRICKWORK 1 GENERAL

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Stonecraft Industies 8300 County Road Holmesville, OH

DURRELL DESIGN GROUP, PLLC ROOF REPLACEMENT BARR ELEMENTARY SCHOOL JACKSON PUBLIC SCHOOL DISTRICT JACKSON, MISSISSIPPI.

Thin Architectural Splitface Block Veneer Specification Guide

Last Modified: Jun 15, 2016 degruchy's Ecologic Mortar... Just add water!

SECTION (Master Format, 1995 Edition, 04700) MANUFACTURED MASONRY

Magna Wall. Scratch and Brown with Fiber. Product Overview, Instructions, & Data. Durable

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

ARDEX GUIDE SPECIFICATION ARDEX TRM Transportation Repair Mortar Fast-Setting Concrete Repair Mortar

DIVISION VIII - DOORS AND WINDOWS

SECTION ARCHITECTURAL PRECAST CONCRETE. C. Section Joint Sealers: Perimeter joints with sealant and backing.

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

St. Astier NHL Plasters

DIVISION 3 - CONCRETE Section Concrete Rehabilitation

DIVISION 3 - CONCRETE Section Concrete Rehabilitation

Spec Master 5/7/ For each product requiring color and texture selection, provide full size samples.

SECTION SPLIT FACE CONCRETE MASONRY UNITS

SECTION Vitrified Clay Wall Coping 2014

SECTION STAMPED CONCRETE PAVING

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

GYPSUM BOARD AND PLASTER

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MRXL4 CR6 Surface Requirements: XNS, NS, M, S; Special Requirements: NO PART 1 : GENERAL

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

Sto Guide Specification No. F601S StoQuik Gold Finish System for Soffits and Ceilings

External solid plastering: overview

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

SECTION LATEX-MODIFIED MEDIUM BED MORTAR

SECTION MANUFACTURED STONE VENEER. A. Section Includes: 1. Manufactured stone veneer masonry, accessories, and related materials.

HammerStone Manufactured stone veneers for commercial & residential applications

A. Section Includes: 1. Patching of exterior portland cement plasterwork (stucco) on metal lath.

for Mortar-Set Concrete Tiling Installations

.1 Provide textured finish system for gypsum or cement board soffit and ceiling surfaces.

EUROPLAST. Color 20 standard colors, see color chart for specifics. Special colors available upon request, virtually no limit to selection of shades.

CTIOA REPORT

MDC MicroTex Eggshell Micro-Textured Ceramic Coating for Walls

Kolorines Glass Mosaic Tiles Project Specification

Transcription:

MANUFACTURER'S SPECIFICATIONS Section 09225 ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE ST. ASTIER NATURAL HYDRAULIC LIME PLASTER PART 1 GENERAL 1.1 Summary A. This Section includes St. Astier Natural Hydraulic Lime plaster system. B. Related Sections 1.2 References 1. Section [ ]: Wall substrate surface. A. American Society for Testing and Materials 1. ASTM C25 Test Methods for Chemical Analysis of Limestone, Quicklime and Hydrated Lime. 2. ASTM C91 Standard Specification for Masonry Cement. 3. ASTM C109 Test Method for Compressive Strength of Hydraulic Cement Mortars. 4. ASTM C141 Standard Specification for Hydraulic Lime for Structural Purposes. 5. ASTM C144 Standard Specification Aggregate for Masonry Mortar. 6. ASTM C150 Standard Specification for Portland Cement. 7. ASTM C206 Standard Specification for Finishing Hydrated Lime. 8. ASTM C207 Standard Specification for Hydrated Lime for Masonry Purposes. 9. ASTM C897 Standard Specification for Aggregate for Job-Mixed Portland Cement-Based Plasters 10. ASTM C926 Standard Specification for Application of Portland Cement-Based Plaster. 11. ASTM C979 Standard Specification for Pigments for Integrally Colored Concrete. B. Portland Cement Association 1. PCA Portland Cement Plaster (Stucco) Manual. C. European Standard 1. EN 459-1 Building Lime Part 1: Definitions, Specifications and Conformity Criteria 09225-1 St. Astier Natural

2. EN 459-2 Building Lime Part 2: Test Methods 3. EN 459-3 Building Lime Part 3: Conformity Evaluation 1.3 Performance Requirements A. Structure to be designed in such a way as to minimize the transfer of stress from building to plaster skin. 1.4 Submittals A. Section 01330 Submittal Procedures: Submittal Procedures. B. Product Data: Submit data on plaster materials, characteristics and limitations of products specified. C. Samples: Submit two samples, 12 inch by 12 inch in size, illustrating finish color and texture. 1.5 Quality Assurance A. Perform Work in accordance with Manufacturer's Instructions 1.6 Qualifications A. Manufacturer: All St. Astier NHL shall be obtained from: LimeWorks.us 3145 State Road Telford, PA 18969 215-536-6706 215-453-1310 Fax info@limeworks.us www.limeworks.us Or its authorized distributors. B. Installer: Company specializing in performing plaster/stucco work with minimum of three (3) years 1.7 Mock-up experience. A. Section 01400 Quality Requirements: Requirements for mock-up. B. Construct mock-up, feet long by inch wide, including exterior and interior wall and ceiling system illustrating surface finish and color. C. Locate where directed by Architect. D. [Incorporate accepted mock-up as part of Work.] 09225-2 St. Astier Natural

1.8 Pre-Installation Meetings A. Section 1300 Administrative Requirements: Pre-Installation Meeting. B. Convene minimum one week prior to commencing work of this SECTION. 1.9 Environmental Requirements A. Provide environmental conditions at areas where Work of this SECTION is being performed to allow limeplaster to properly cure. B. Take precautionary measures necessary to assure that excessive temperature changes do not occur. C. Do not apply limeplaster unless minimum ambient temperature of 45 degrees F and a maximum of 85 degrees F has been and continues to be maintained for a minimum of 48 hours prior to application and until plaster is cured. D. Hot Weather Requirements: Protect limeplaster from uneven and excessive evaporation during dry, hot weather. Provide tarping over the outside of all scaffolding. PART 2 PRODUCTS 2.1 Lime Plaster (NHL) A. Manufacturer 1. CESA Imported and distributed by LimeWorks.us 2. Substitutions not permitted. 2.2 Components A. Plaster Base Materials 1. Binder: St. Astier Natural Hydraulic Lime NHL [3.5] [5]. 2. Aggregate: Natural or Manufactured Sharp Sand with at least 4 grades forming a substantial part of the sand and no more than 3% of particles smaller than grade #200 (0.075mm). 3. [Pre-Mix: Ecologic G, Ecomortar G.] 4. [Fibers: _ inch nominal length glass fibers meeting requirements of ASTM C1116.] [Fibers: animal hair] 09225-3 St. Astier Natural

B. Plaster Finish Materials 1. Binder: St. Astier Natural Hydraulic Lime NHL 2. 2. [Pre-Mix: Ecologic F, Ecomortar F.] 3. Color Pigment: ASTM C979 mineral oxide type, [ ]color. 4. Water: Clean, fresh, potable and free of mineral or organic matter capable of affecting plaster. C. Finish Aggregate. 1. Aggregate: Natural or Manufactured Sharp Sand with at least 4 grades forming a substantial part of the sand and no more than 3% of particles smaller than grade #200 (0.075mm). 2.3 Mixes A. Scratch [Dash Bond] Coat: 1 part NHL [3.5] [5] and [1.5] [2] parts of sand, proportioned by volume. [1. Fiber Reinforcement: add [fiber] [hair] to scratch coat] B. Brown Coats: [1 part NHL 3.5 and [2] [2.5] parts of sand, proportioned by volume.] [Ready-Mix: Ecologic G, Ecomortar G] C. Finish Coat: [1 part NHL 2 and [2.5] [3] parts of sand, proportioned by volume.] [Ready-Mix: Ecologic F, Ecomortar F] D. Mix only as much plaster as can be used prior to initial set. E. [Add color pigments to finish coat.] F. Mix materials dry, to uniform color and consistency, before adding water. G. Protect mixtures from freezing, frost, contamination, and excessive evaporation. PART 3 EXECUTION 3.1 Examination A. Section 01300 Administrative Requirements: Coordination and project conditions. B. Surface to be sound enough to receive plaster coat. C. Verify that no bituminous or water repellent coatings exist on concrete. D. Mechanical and Electrical: Verify surfaces within walls have been tested and approved. 09225-4 St. Astier Natural

3.2 Preparation A. Dampen surfaces to reduce excessive suction. B. Clean surfaces of foreign matter. Clean surfaces using acid solutions, solvents or detergents. Wash surfaces with clean water. C. Prior to the scratch coat being applied, any excessive depression or hollow requiring dubbing out should be carried out using 1 part NHL [3.5] [5] and [1] [1.5] [2] parts sharp sand by volume. D. Roughen smooth surfaces by [sandblasting] [applying bonding agent] [applying dash bond coat]. 3.3 Installation A. [Installation of Accessories:] 1. [Install accessories in accordance with ASTM C1063.] 2. [Place corner bead at external wall corners.] 3. [Place casing beads at terminations of plaster finish. Butt and align ends. Secure rigidly in place.] 4. [Install door and glazed frames plumb and level in opening. Secure rigidly in place.] B. [Control and Expansion Joints:] 1. [Install interior control and expansion joints.] 2. [Install exterior contraction joints after initial set, scribed as indicated on Drawings by cutting through 2/3 of lime plaster depth, neatly, in straight lines.] 3. [For horizontal exterior surfaces, install control and expansion joints as indicated on Drawings.] 4. [For vertical exterior surfaces, install control and expansion joints as indicated on Drawings.] C. Plastering 1. Apply plaster in accordance with manufacturer s instructions. 2. Apply scratch [dash bond] coat to a nominal thickness of [1/8] [3/16] inch, and brown coat to nominal thickness of [3/8] [1/2] inch over concrete surfaces. 3. Apply finish coat to a nominal thickness of [1/8] [3/16] [5/16] inch. 4. After curing, dampen previous coat prior to applying finish coat. ALLOW 7 to 10 DAYS 09225-5 St. Astier Natural

BETWEEN COATS. 5. Apply finish coat [to indicated color and texture.] [to [light dash] [medium dash] [heavy dash] [fine sand float] [medium sand float] [heavy sand float] [combed] [glacier] [aggregate surfaced] [ ] texture with selected color. 6. Avoid excessive working of the surface. Delay troweling as long as possible to avoid drawing excess fines to surface. 3.4 Erection Tolerances A. Section 01400 Quality Requirements: Tolerances. 3.5 Adjusting A. Section 01700 Execution Requirements: Testing, adjusting, and balancing. B. Remove damaged or defective plaster by cutting and replace with 3.6 Schedules END OF SECTION 09225-6 St. Astier Natural