MassBloc Permeable Instant Wall System

Similar documents
MassBloc Retaining Wall EARTH RETENTION

T-WALL.

MagnumStone Specifications Gravity

Earth Retaining System

DESIGNING AND CONSTRUCTION OF T-WALL RETAINING WALL SYSTEM

ODOT Design & Construction Requirements for MSE Walls

NOVEMBER 2016 MAGNUMSTONE. retaining walls technical manual

WATER AND DRAINAGE. Drainage Around Walls Water Applications Drainage Structures Water and Drainage Q & A

Right look. Right strength. Right size.

T-WALL & STONE STRONG

CHAPTER 11: WALLS.

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

ENGINEERING DIRECTIVE

SPECIFICATION FOR REINFORCED SOIL WALL

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

Save time. Save money. Specify a fast, economical Vist-A-Wall MSE. fast and easy to install. They adapt well to curves, angles and

MECHANICALLY STABILIZED EARTH (MSE) WALL SYSTEMS

Reinforced Earth Company. technology applications services

engineered by application

GreenLock L9 Heavy Duty Retaining Wall Block (RWB) Features and advantages of the L9 retaining wall block

Precast Panel Walls Wire Walls. Introducing the Grid-Strip TM Soil Reinforcement System. ail.ca. Saves time and money

A Complete Retaining Wall Solution >

Geoguide 6 The New Guide to Reinforced Fill Structure and Slope Design in Hong Kong

ArmorFlex. Articulating Concrete Block Revetment System

MSE Walls Problems and Solutions

Right look. Right strength. Right size.

AUGUST 2017 HASTINGS. retaining walls installation guide

TENSARTECH TW1 WALL. earth retaining system for walls

Plastic Piling Solutions

Structures concrete. Structures concrete

Uniclass L151:P7113 EPIC A41:X724. CI/SfB (17.1) Hn6. Plastic Piling

Since its inception in 1986, Keystone has been the segmental retaining wall design leader.

DESIGN CONSIDERATIONS FOR NSWS NATURAL STONE RETAINING AND FREE-STANDING WALL SYSTEMS

THE BEBO SYSTEM. World s Best for Overfilled Arches. For Precasters, Bridge Suppliers, General Contractors, Road/Rail Authorities and Consultants

TensarTech TW1 WALL. earth retaining system for walls

INDOT Wall System Approval Criteria and Design Review

Description. This work shall consist of furnishing materials and placement of modular block wall constructed in accordance with

RPC Contracts is committed to innovative product development and manufacture. T o help you obtain maximum enjoyment and long service from any RPC

ADDRESS: 122 LIPSCOMBE ROAD, DECEPTION BAY, QLD,

PISA. Retaining Wall System. The choice of professional contractors

Redi Rock Specification and Installation Manual

SPECIFICATION FOR CORNERSTONE GEOGRID REINFORCED SEGMENTAL RETAINING WALL SYSTEM

The Speed of Gravity. Gravity retaining walls built with Stone Strong System s Big Block Technology are the most efficient solution on the market.

Grade separated interchange at the intersection of U.S. Hwy 17 Bypass and Farrow Parkway

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

Armorflex. The 6 easy steps to site assembled Armorflex... The engineered solution for simple erosion protection. Step 2. Step 1. Step 3.

Bordeaux Walling. Product & Technical Information

Design and Installation Guidelines for Retaining Walls. 1 P age. Geo Products, LLC 8615 Golden Spike Lane Houston, TX Phone:

MagnumStone Product Guide

STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION CITY OF WEST BEND, WISCONSIN SECTION 300 EARTHWORK, GRADING, AND GRAVELING

MANDATORY SUPPLEMENTAL SPECIFICATIONS FOR CONTRACTOR QUALITY CONTROL Contractor Quality Control - is replaced with the following:

SECTION EROSION CONTROL DEVICES

Geo synthetics and Reinforced Soil Structures Prof. K. Rajagopal Department of Civil Engineering Indian Institute of Technology, Madras

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 9/17/18)

VERTI-BLOCK - DESIGN MANUAL

Tasman Retaining Wall System

Earth Retaining Structures and Systems Submittal Checklist. Part One: Materials and Material Properties

MagnumStone. Product Brochure

Design & Seismic Detailing of Nonstandard Deep Precast Concrete Box Girders For Long Span Railroad Bridges By:

TW1 Wall System. TENSAR technology. Tensartech Systems for Earth Retaining Walls

Right look. Right strength. Right size.

CONTENTS. Cellular Confinement System INTRODUCTION MATERIALS Multi-Cell Fill... 2

STATE DEPfiRTMEHT OF HIGHWAYS RHD PUBLIC TRRHSPORTflTlOH. For Loan Only: CTR Library

Earth Retaining Walls CIVL455 CHAPTER I: INTRODUCTION

Features Include: Near Vertical Walls Do it Yourself No Concrete Footings Required

UPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04

INS T A LLA T I O N G U I D E

Figure Inlet protection (Source: Minnesota DOT)

SPECIFICATION FOR MAGNUMSTONE GEOGRID REINFORCED Mechanically Stabilized Earth (MSE) SYSTEM


Retaining Wall Systems

Bolt-A-Bin. We Support You. We Support You.

Giving terraces an attractive and natural support

SECTION SEGMENTAL CONCRETE UNIT MASONRY RETAINING WALL MAXIMUM HEIGHT OF 5-0 HIGH

Weholite LIGHTWEIGHT PIPE SYSTEM

NOVEMBER 2016 GRANDWALL. retaining walls installation guide

TABLE OF CONTENTS. 0 Structural calculations 0.1 General 0.2 Safety concept 0.3 Calculations for waterfront structures

Bridge Installation Guide

ARMOR-BLOCK. Installation guide. Installation Manual: ARMOR-BLOCK Retaining Wall System. Cap Block. Exposed void for planting.

Garden WallScape Installation Guide

Reinforced Earth wall Construction Manual

5-20 FOUNDATION REPORT/GEOTECHNICAL DESIGN

Drawings shown within this brochure is the Preston CarPark Innovation Concept and patents filed in August 2018.

DESIGN OF RETAINING WALLS

Right look. Right strength. Right size.

CONCRETE RETAINING BLOCK WALLS

Submission for the NEW ZEALAND CONCRETE SOCIETY CONCRETE AWARDS 2015 OKURA RIVER BRIDGE. Submitted by David Hepburn Bridge Concepts Ltd

Uwall UNIVERSAL CONSTRUCTION MANUAL

Providing proper drainage system

HUITEX GEOCELL INSTALLATION MANUAL

GRAVITY SEGMENTAL RETAINING WALL

Notes for Erection of Evergreen Maxi Wall Retaining Walls

Tasman and Norfolk Retaining Wall

Tasman Retaining Wall System

CONCRETE SEGMENTAL RETAINING WALLS

DE-SPAN Design Guideline. Manufactured 100% indoors. Under 100% controlled conditions.

207 TEMPORARY SEDIMENT AND EROSION CONTROLS

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

Transcription:

PIPELINE SYSTEMS 131 004 www.rocla.com.au MassBloc Permeable Instant Wall System PIPELINE SYSTEMS

MassBloc Retaining Wall Permanent Retaining Structures The Rocla MassBloc retaining wall system comprises large precast permeable concrete blocks manufactured under stringent quality control. Construction is mortarless and an experienced crew can place up to 70m 2 of wall per day. The blocks are interlocked by a nib precast into the base of each standard unit. The rough concrete surface of the blocks aids resistance to shearing by increasing the friction between units. Ease of handling makes the Rocla MassBloc system ideal for: Temporary highways - slip stabilisation Embankment stabilisation Temporary bin storage Mass gravity walls Reinforced soil structures Bridge abutments Stream channels Coastal protection Sea walls Erosion prevention Tunnel access walls Wing walls

Design service Rocla can provide a design service as part of the MassBloc package, if required. Note that all Rocla MassBloc walls must be built in accordance with a design specific to each site prepared by a registered engineer. Manufacturing flexibility Blocks can be manufactured with varying height and width (maximum height 1000mm, maximum width 1190mm). Blocks can also be supplied in a range of colours to improve aesthetic appearance or complement the surrounding environment. Minimal impact on waterways For environmentally sensitive areas, construction can proceed by reaching out from waterway banks or off a previously constructed span. No need to build coffer dams or interfere with the waterway. Transport The Rocla MassBloc system is available ex-factory or delivered to site. The base unit weighs 1.7 tonne and the standard block 1.8 tonne. Care must be taken during transport to prevent blocks from coming into contact with each other. Fast, permanent prevention of land slippage Rocla MassBloc retaining walls are economical, easy to transport, quick to install and require minimal base preparation. The precast concrete blocks interlock to create permanent retaining structures that can be rapidly deployed to counter erosion, land slippage and wave energy. The system is ideal for cut and fill installations. Blocks are manufactured at a number of Rocla precast facilities for delivery Australia-wide. Installation Rocla s MassBloc system is simple to install. Blocks are manufactured consistently to specification. The key to successful installation is a perfectly level, well compacted base.

Typical Rocla MassBloc Retaining Wall Backfill to engineer s design Block geometry permits radius curves Set back 170mm In situ soil Geotextile Backfill to engineer s design Block geometry permits radius curves Set back 170mm Half width block In situ soil Geotextile Half width block Agricultural pipe Fully compacted hardfill to engineer s design In situ soil IMPORTANT: This diagram is indicative and for setout reference only. All Rocla MassBloc walls irrespective of height must be built in accordance with a design prepared by a registered engineer who is to be engaged by the purchaser. The engineer s design drawings and details shall take precedence if there is any conflict or ambiguity In situ soil with this diagram. Agricultural pipe Fully compacted hardfill to Standard Unit Base engineer s Unit design The standard unit has a nib (170mm wide) at the bottom of the block that overhangs the blocks below Block weight 1.8 tonne The base unit forms the bottom row of the wall and has no nib Block weight 1.7 tonne Width of back 840mm Depth of block 900mm Width of back 840mm Depth of block 900mm SwiftLift anchor Height of back 1150mm Height of block 1000mm Height of front 1000mm Width of front 1190mm Width of front 1190mm

Performance Dry stacked, mortarless construction. The system can tolerate movement and settlement without causing visual distress at the face. Rocla MassBloc walls are relatively flexible structures that are typically based on a compacted aggregate foundation. Permeability Rocla MassBloc walls are permeable structures. Permeability can be supplemented by agricultural pipe to reduce the development of hydrostatic pressure behind the blocks. Durability Rocla MassBloc components are manufactured from wet-cast concrete, resulting in a very durable retaining wall system. The blocks are resistant to cracking and do not splinter or decay like treated timbers or railroad sleepers. The blocks contain no steel reinforcement (apart from a galvanised lifting eye) and have no exposed wires to corrode. Rapid Deployment Two experienced workers with an excavator can place up to 70m 2 of wall per day. Blocks are easily lifted and placed using the galvanised lifting eye cast into the top of each block.

MassBloc Retaining Wall MASSBLOC PIPELINE SYSTEMS