ADVANTECH SHEATHING SUBMITTAL FORM

Similar documents
ESR-1785* Reissued December 1, 2012 This report is subject to renewal December 1, 2014.

ICC-ES Evaluation Report Reissued October 1, 2010 This report is subject to re-examination in two years.

AdvanTech Sheathing and Subfloor Panels

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHEATHING REPORT HOLDER: HUBER ENGINEERED WOODS, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHEATHING REPORT HOLDER: HUBER ENGINEERED WOODS, LLC EVALUATION SUBJECT:

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Explaining PS 1 and PS 2 Gradestamps

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLEXIBLE FLASHINGS REPORT HOLDER: HUBER ENGINEERED WOODS, LLC

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

Section II Subfloor Guidelines & Specifications Page Chapter 4 Wood Subfloor Guidelines 23 Chapter 5 Concrete Subfloor Guidelines 26 Chapter 6

ZIP System Sheathing Load-Span Tables

Green Features. Exterior Features. Luxury Kitchen Features. Interior Features

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

WOOD I-JOIST AWARENESS GUIDE

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

LP OSB Sheathing & Structural 1 Sheathing

Trusted ICC ES APA TH STREET. Conformity! subject of the

Innovative Solutions for Multifamily & Light Commercial

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

SECTION STRUCTURAL INSULATED PANELS

Originally Issued: 11/04/2016 Revised: 11/28/2017 Valid Through: 11/30/2018

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

Specifications. Materials and Fabrication. Physical Properties. Environmental Impact. Sizes. Installation - General Requirements.

1. The subfloor must be structurally sound and able to withstand live and dead loads with a deflection limitation of L/360.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

ESR-2961 Reissued September 1, 2011 This report is subject to renewal in two years.

AdvanTech Flooring & Sheathing

Eclipse OSB Radiant Barrier OSB Structural Panels from RoyOMartin

PLYWOOD FLOATING FLOOR

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

Warmboard-S Radiant-Floor Heating Panels PR-V180 Warmboard, Inc. Revised February 19, 2018

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

Please read and review installation instructions completely before proceeding with the actual installation.

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

Overcoming Structural Floor Squeaks in Wood Framed Construction Presented by: Don Simon Huber Engineered Woods

Table R (1) Allowable Spans and Loads for Wood Structural Panels for Roof and Subfloor. Sheathing and Combination Subfloor Underlayment

City of Long Beach Department of Development Services Building and Safety Bureau. Design Limitation for Wood Shear Walls

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

SECTION Fiber Reinforced Stucco 1

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

Joint Evaluation Report ICC-ES (800) (562)

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

DIVISION: CONCRETE SECTION: CEMENTITIOUS WOOD FIBER DECKS DIVISION: FINISHES SECTION: ACOUSTIC ROOM COMPONENTS

Joint Evaluation Report ICC-ES (800) (562)

Where Vision Meets Integrity Structural and Envelope Solutions Multifamily & Commercial

FIGURE R502.2 FLOOR CONSTRUCTION

LPI 56 Technical Guide

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

A. Dimension Lumber: Lumber of 2 inches nominal or greater but less than 5 inches nominal in least dimension.

A. Dimension Lumber: Lumber of 2 inches nominal or greater but less than 5 inches nominal in least dimension.

PRP-108 Performance Standards and Policies for Structural-Use Panels

PROJECT LOCATION. SECTION RECYCLED WOOD FLOORING Rev. 11/13/2012

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003

PFC-5804* Reissued February 1, Filing Category: DESIGN Wood

A. Meet at Project site <insert number> days before starting installation.

Trusted WOOD I JOISTS SECTION: 06 ON WEB i. Conformity! ICC-ES Evaluation. Copyright 2015

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

OUR COMPANY OUR WARRANTY OUR GUARANTEE

Joint Evaluation Report

GREEN BRIEF. Conserve. Create. Renew. Rim Board. LP SolidStart Rim Board & the Environment

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

PR-L274 Nordic Structures Revised April 16, 2017

RoyOMartin TuffStrand and Windbrace 7/16 Performance Category OSB PR-N129 Martco, L.L.C. Revised November 6, 2017

SECTION PREFINISHED ENGINEERED WIDE-PLANK FSC OAK FLOORING

Installation of Stucco Exterior Finish Over Wood Structural Panel Wall Sheathing

SECTION PREFINISHED FSC MAPLE FLOORING. This is a template: edit this specification carefully to suit specific project requirements.

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

Joint Evaluation Report

Joint Evaluation Report

Contents. ZIP System R-Sheathing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

SHEATHING & TAPE THE START TO A GREAT BUILD.

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

TECH BULLETIN. SIP No. Subject: Engineered Wood Lap Siding from Louisiana-Pacific. Date: August 2010 (Revised January 2015)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

Updated references to SEI/ASCE 7 to the 2016 edition once it is available.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

Wood-Framing Methods For Energy Savings

Mr. Bamboo, Inc. - BamLoc Prefinished Strand Woven Bamboo Flooring CSI Masterformat 3-Part Specification

Technical Data for. Headers. and Beams

TECHNICAL BULLETIN. MR 7.0 Certified Wood Encourage environmentally responsible forest management.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

International Beams, Inc. Revised June 20, 2018

MFMA Guide Specification for Sleeper and Sleeper with Plywood Floor Systems

SECTION ROOF AND DECK INSULATION

ZIP SYSTEM Roof & Wall SHEATHING

Joint Evaluation Report

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER

1¾" VERSA-LAM WESTERN HEAdER GuidE

Transcription:

ADVANTECH SHEATHING SUBMITTAL FORM APPLICATION: TWO LAYER FLOATING FLOOR Submitted to: Job Name: Submitted by: Date: Product * : Top Layer: 1/2 PERF CAT (SE) 5/8 PERF CAT (SE) 5/8 PERF CAT (T&G) 23/32 PER CAT (SE) Bottom Layer: 1/2 PERF CAT (SE) 5/8 PERF CAT (SE) 5/8 PERF CAT (T&G) 23/32 PER CAT (SE) *SE indicates square edge profile. T&G indicates tongue and groove edge profile. Tongue and groove edge profile is only available in 5/8 PERF CAT. Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262 800 933 9220. www.zipsystem.com. www.huberarchitectlibrary.com Technical Service Hotline: 800.933.9220 ext. 2716

ADVANTECH SHEATHING MANUFACTURER Huber Engineered Woods LLC 10925 David Taylor Drive, Suite 300, Charlotte, NC 28262 800.933.9220 Technical Service: 800.933.9220 x2716 ZIPSystem.com HuberArchitectLibrary.com BASIC USE AND APPLICATIONS AdvanTech sheathing is a high performance engineered panel designed to replace plywood and commodity oriented strand board (OSB) for roof, wall, and 2 layer floating subfloor system applications. Fabricated in highly controlled production facilities utilizing advanced resin technology, AdvanTech sheathing exhibits higher strength, greater stability and enhanced moisture resistance. AdvanTech sheathing exceeds the code minimums representing other sheathing products, providing owners with a more stable sheathing and builders with a more reliable product that retains its qualities under environmental exposure during construction. AdvanTech sheathing panels are appropriate for a wide range of applications, including, but not limited to: Wall sheathing Roof sheathing 2 Layer floating subfloor Shear walls LIMITATIONS ON USE When installing AdvanTech sheathing, designers should incorporate a 1/8 expansion joint to accommodate panel expansion. This is an industry recommendation and is not unique to AdvanTech sheathing. AdvanTech sheathing is an Exposure 1 rated panel, and should not be used in permanent exterior applications. AVAILABLE SIZES AND RATINGS AdvanTech sheathing panels are offered in three thicknesses (1/2", 5/8", 23/32") for a wide range of conditions. All panels are available in nominal 4 by 8 foot sheets with square edge profiles, and a tongue and groove edge profile is also available in the 5/8" thickness. AdvanTech sheathing is available in the following DOC PS 2 Sheathing span ratings and performance categories. All panels are Exposure 1 rated. Net Face width is 47 1/2 on tongue and groove panels 32/16, Structural 1, 1/2 PERF CAT 40/20, Structural 1, 5/8 PERF CAT 48/24, Structural 1, 23/32 PERF CAT Third party independent compliance testing of AdvanTech sheathing performed by Timberco, Inc. (TECO). POTENTIAL LEED CREDIT CONTRIBUTION Credit IEQ 4.4 Low Emitting Materials, Composite Wood and Agrifiber: AdvanTech contains no added urea formaldehyde Credit MR 5.1 or 5.2 Regional Materials: Materials harvested, processed, and manufactured within 500 miles of project site. Credit MR 2.2 Environmentally Preferable Products Local Production (LEED for Homes) GENERAL SUSTAINABLE DESIGN CONTRIBUTIONS Low Emitting Material: No added urea formaldehyde or VOC constituents Sustainable Forestry Initiative Certified Wood: Harvested, transported, manufactured, and distributed utilizing sustainable practices Renewable Forest Resources: Composed of primarily young growth bio based resources Regional Materials: Made in the United States at one of our four regional manufacturing facilities: Commerce, GA; Broken Bow, OK; Crystal Hill, VA; and Easton, ME AVAILABLE RESOURCES Section 06 16 00 SHEATHING guide specification for AdvanTech flooring and sheathing products in CSI 3 part format is available at HuberWood.com or HuberArchitectLibrary.com. STORAGE AND HANDLING Store and handle products according to manufacturer s written recommendations. Support panel bundles off the ground. Cover stored panels with weatherproof protective material; allow sides of protective material to remain loose to assure adequate air circulation. In high moisture conditions, cut bundle banding to prevent edge damage to the panels.

ROOF/WALL SHEATHING INSTALLATION Before beginning installation, verify framing is properly spaced and aligned to support panel edges. Install AdvanTech sheathing in accordance with: AdvanTech sheathing installation instructions ICC ES ESR 1785 Requirements of authorities having jurisdictions When used as roof sheathing, install panels with the long edge perpendicular to framing members, spanning at least three framing members, and with short edges fully supported. Stagger short edge seams. When used as used as wall sheathing, the panels may be installed with the long side of the panel oriented either horizontally or vertically to the framing members. Walls that are designed to resist lateral shear forces and sheathed with wood structural panels typically require solid framing or blocking behind all panel edges. For both roof and wall applications, all panel edges should be manually spaced approximately 1/8 inch (3 mm) apart. AdvanTech sheathing can be installed over wood or coldformed metal framing. Install over wood using nail or screw fasteners, and over metal with screw fasteners. Install fasteners approved by applicable building code. Install fasteners 3/8 inch (9.5 mm) from panel edges. Space fasteners 6 inches (152 mm) on center on supported panel ends and 12 inches (305mm) on center at intermediate supports in the field unless otherwise specified. AdvanTech sheathing panels have a printed fastening guide for 16 inch (406 mm) and 24 inch (610 mm) on center fastener locations. FLOATING SUBFLOOR INSTALLATION When used as a floating subfloor system, verify the concrete slab is fully cured per the applicable building code with the building fully dried in. Floating subfloor systems can be installed on sub grade, on grade, or above grade concrete slab. A vaporretarder should be installed anytime solid wood flooring is being installed over a concrete slab per National Wood Flooring recommendation. The minimum AdvanTech panel thickness on the first layer should be 1/2 with 1/8 spacing between panels and 3/4 spacing between vertical obstructions. The second layer of AdvanTech panels are to be installed perpendicular or at a 45 degree angle to the first layer. The same 1/8 spacing between panels and 3/4 spacing between vertical obstructions should be applied. The second layer should be fastened to the first layer using staples or staple and glued fastening method using a 12 interior grid pattern and a 6 spacing around the perimeter. Screws or screws and glue may also be used in lieu of staples. For complete installation instructions for AdvanTech panels as a 2 layer floating subfloor system please see our Tech Tip AdvanTech Panels Installed as a 2 Layer Floating Subfloor. WARRANTY AdvanTech sheathing carries a lifetime limited warranty. Refer to the designated warranty based on application for limitations and restrictions. AdvanTech panel warranty information found on advantechperforms.com. AVAILABILITY Huber Engineered Wood s AdvanTech sheathing panels are manufactured at multiple locations in the U.S. and are available through distributors nationwide. Visit advantechperforms.com or contact Huber Engineered Woods for a retailer near you.

TECHNICAL SERVICE Detailed information including specifications, product literature, test reports, installation instructions, and special applications are available through Huber Engineered Woods. Please visit advantechperforms.com or call 800.933.9220 Ext 2716 to speak to a technical representative. 1 ICC ES Evaluation Services Report ESR 1785 2 2012 edition of the AF&PA American Wood Council s, Allowable Stress Design (ASD)/LFD Manual for Engineered Wood Construction, based on 4 ply plywood 3 2005 Edition National Design Specification, Nail and Spike withdrawal equation using 10d Common Nail 4 APA Technical Topic TT 039C, Recommended Design Values for Nail Withdrawal from APA Plywood and OSB 2015 Huber Engineered Woods LLC. AdvanTech is a registered trademark of Huber Engineered Woods LLC. Huber is a registration trademark of J.M. Huber Corporation. HUB 9001 REV 5/15