Assessing contaminant mass flow rates obtained by the integral groundwater investigation method by using the Virtual Aquifer approach

Similar documents
Groundwater Models and Modeling Considerations

CHAPTER 2. Objectives of Groundwater Modelling

Design of a passive hydraulic containment system using FEFLOW modelling

Groundwater Risk Assessment

7.0 GROUNDWATER AND STABILIZER TRANSPORT MODELING

(,,,) = ( )exp ( + C(x,y,z,t) = the concentration of the contaminant at location x, y, z from the source at time t.

ATTACHMENT 12: CDISCO Description and Sensitivity to Input Parameters

Simulation of horizontal well performance using Visual MODFLOW

Simplicity in Modeling Use of Analytical Models with PEST

Site Verified Contaminant Transport Model as a Mathematical Vehicle for Prevention of the Natural Aquifer Contamination

Geothermal reservoir simulation of hot sedimentary aquifer system using FEFLOW

SOURCES OF WATER SUPPLY GROUND WATER HYDRAULICS

Genetic Algorithm based Simulation Optimization Approach to Seawater Intrusion

AIR FORCE INSTITUTE OF TECHNOLOGY

TECHNICAL GUIDANCE. Groundwater Protection Model ON CONTAMINATED SITES

OPTIMIZATION OF GROUNDWATER RESOURCES MANAGEMENT IN POLLUTED AQUIFERS

POROSITY, SPECIFIC YIELD & SPECIFIC RETENTION. Physical properties of

CERAMIC DOSIMETERS FOR TIME-INTEGRATED CONTAMINANT MONITORING

Limitations of Using Uniform Heat Flux Assumptions in Sizing Vertical Borehole Heat Exchanger Fields

Monitoring and modelling catchment water quantity and quality

EFFECT OF NATURAL CONVECTION PATTERNS ON OPTIMAL LOCATION AND SIZE OF A HEAT SINK IN A GEOTHERMAL RESERVOIR

Upscaling of two-phase flow processes in heterogeneous porous media: determination of constitutive relationships

Mathematical Modeling of Groundwater Pollution

Using Fractran Fracture Flow Modeling in Tandem with Modflow to Assist in the Development of Wellfield Protection Zones for Municipal Wells in Bedrock

Connecticut Department of Energy and Environmental Protection and Environmental Professionals Organization of Connecticut, Inc.

Transient and Succession-of-Steady-States Pipeline Flow Models

VI. WATER QUALITY MODELING

Estimation of Nitrate Load from Septic Systems to Surface Water Bodies Using ArcNLET: an ArcGIS-Based Nitrate Load Estimation Toolkit

Practical considerations for Monte Carlo simulations: From characterization of complex spatial uncertainty to prediction of groundwater flows

STAGNATION POINTS: ANALYTICAL THEORIC APPROACH

Lateral Outflow from Supercritical Channels

Comparison between Neuman (1975) and Jacob (1946) application for analysing pumping test data of unconfined aquifer

Interpreting tracer data to forecast remedial performance

Importance of irrigation return flow on the groundwater budget of a rural basin in India

Groundwater modelling to assess the effect of interceptor drainage and lining

AN APPLICATION OF STAGNATION POINTS THEORY

Propagation of water table waves in unconfined aquifers

Aquifer Physics Modes for Hydrogeological Modeling an Application of the COMSOL Physics Builder

ELBE RIVER MODEL: UVP FLOW MAPPING

Potential effects evaluation of dewatering an underground mine on surface water and groundwater located in a rural area

OpenMI coupling of FEFLOW and MIKE SHE

Thermal Performance of a Deviated Deep Borehole Heat Exchanger: Insights From a Synthetic Heat and Flow Model

Purpose. Utilize groundwater modeling software to forecast the pumping drawdown in a regional aquifer for public drinking water supply

Groundwater modelling to help diagnose contamination problems

Multiphase flow and enhanced biodégradation of dense non-aqueous phase liquids: experimental design

Residual Stress Analysis in Injection Moulded Polycarbonate Samples

5.4 Analysis for Torsion

Sections 5 & 6. Site Characterization and Lines of Evidence. Steve Posten

SHE: towards a methodology for physically-based distributed forecasting in hydrology

Measuring discharge. Climatological and hydrological field work

Numerical study of the influence of injection/production well perforation location on CO 2 -EGS system

Discrete Fracture Embedding to Match Injection Returns in a Single Porosity Model

An experimental study of permeability determination in the lab

Subject: Peer review of Duntroon Quarry hydrogeologic modelling: Report #1

Estimating Streambed and Aquifer Parameters from a Stream/Aquifer Analysis Test

API SOIL & GROUNDWATER RESEARCH BULLETIN

Literature Review: Groundwater in LSMs

Development of an Analytical Groundwater Contaminant Transport Model

Computation and analysis of temperature distribution in the crosssection

A simple model for low flow forecasting in Mediterranean streams

List of Tables... iii List of Figures... iii Executive Summary... ES - i

CWR 6536 Stochastic Subsurface Hydrololgy

National Groundwater & Contaminated Land Centre report NC/99/38/2

Permeability, Flow Rate, and Hydraulic Conductivity Determination for Variant Pressures and Grain Size Distributions

CHAPTER 6 COLLECTION SYSTEM HYDRAULIC MODEL

9 Multi-layered aquifer systems

UNIT HYDROGRAPH AND EFFECTIVE RAINFALL S INFLUENCE OVER THE STORM RUNOFF HYDROGRAPH

Task 1 For Task 1, the outlet was set as a zero-gauge pressure outlet, which is the same outlet condition as the five smaller pipes.

Parametric Study for Evaluation of Design Parameters of Standing Column Well

Site Profiles - View. General Information. Contaminants: Site Hydrology:

SALINISATION OF THE NORTHERN COASTEL AREA OF THE NETHERLANDS DUE TO LAND SUBSIDENCE AND SEA LEVEL RISE

Technical Review of the 2011 ESC for the LLWR near Drigg. Issue Resolution Form ESC-TQ-ASO-009 TECHNICAL QUERY

MODELLING AND SIMULATION OF GROUNDWATER INFLUENCE ON BOREHOLE THERMAL ENERGY STORES

Vapor Intrusion Attenuation Factors Based On Long Term Monitoring Data

Groundwater Statistical Analysis Plan

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Comparison of geotechnic softwares - Geo FEM, Plaxis, Z-Soil

Chapter 7 : Conclusions and recommendations

USER S GUIDE. Development of a Design Tool for Planning Aqueous Amendment Injection Systems. ESTCP Project ER June 2008

SUSTAINABILITY AND THE EU LANDFILL DIRECTIVE

Learning objectives. Upon successful completion of this lecture, the participants will be able to:

Project Summary Compilation of Saturated and Unsaturated Zone Modeling Software

APPENDIX 8A HYDROGEOLOGICAL MODEL PRE-MINING, DURING MINING, AND CLOSURE

Upscaling sub-core scale heterogeneity

4D grouting pressure model PLAXIS

STEAM ENHANCED EXTRACTION (SEE) AS INNOVATIVE APPROACH FOR TCE REMOVAL

Analysis of Shear Wall Transfer Beam Structure LEI KA HOU

Using Mass Balance to Assist in Determining Remedial Options. Stephen Thomson URS New Zealand Limited

Rapid Drawdown with Effective Stress

URBAN FLOODING: HEC-HMS

ESECMASE - SHEAR TEST METHOD FOR MASONRY WALLS WITH REALISTIC BOUNDARY CONDITIONS

MELT POOL GEOMETRY SIMULATIONS FOR POWDER-BASED ELECTRON BEAM ADDITIVE MANUFACTURING. Bo Cheng and Kevin Chou

Residual Stress Influence on Material Properties and Column Behaviour of Stainless Steel SHS. M. Jandera 1, J. Machacek 2

2D flood modelling: coping with real world applications

THE RTM-LIGHT MANUFACTURING PROCESS: EXPERIMENTATION AND MODELLING

Development of hydraulic tanks by multi-phase CFD simulation

Explaining soil moisture variability as a function of mean soil moisture: A stochastic unsaturated flow perspective

Impact of Sustainable Cool Roof Technology on Building Energy Consumption

Case study on pollution prediction through atmospheric dispersion modelling

Transcription:

Calibration and Reliability in Groundwater Modelling: From Uncertainty to Decision Making (Proceedings of ModelCARE 25, The Hague, The Netherlands, June 25). IAHS Publ. 34, 26. 23 Assessing contaminant mass flow rates obtained by the integral groundwater investigation method by using the Virtual Aquifer approach S. BAUER & O. KOLDITZ Chair of GeoSystemsResearch, Centre for Applied Geosciences, University of Tübingen, Sigwartstrasse, D-7276 Tübingen, Germany sebastian.bauer@uni-tuebingen.de Abstract Contaminant mass flow rates originating from a contaminant source zone provide a basis for quantifying the environmental impact and may thus play an important role in assessing natural attenuation as a remedial or management option for contaminated aquifer cleanup. A reliable quantification of the contaminant mass flow rate is thus sought. The integral groundwater investigation method provides a possibility for estimating mass flow rates by using long-term pumping tests. This work focuses on the performance and reliability of this method in heterogeneous aquifers and under realistic conditions, representative of a typical site investigation. The Virtual Aquifer method is used for study. The results show that the method is mainly influenced by the hydraulic flow regime near the control plane, where uncertainty in hydraulic conductivity or estimated hydraulic gradient may severely influence the mass flow rate obtained. Determination of the average concentration along the control plane is much less uncertain. Keywords integral groundwater investigation method; mass flow rates; monitoring strategy; uncertainty assessment INTRODUCTION The principal idea of the virtual aquifer is to simulate and evaluate contaminated site investigation strategies by using typical contamination scenarios (Schäfer et al., 22; Schäfer et al., 24; Bauer et al., 25; 26). To achieve this goal, typical aquifers, closely related to reality, are generated in the computer and are polluted with a defined contaminant source. A transport model incorporating the processes governing the pollutant fate in the subsurface is then used to simulate the development of the contaminant plume within the virtual aquifer. The plume generated is then investingated, e.g. by using monitoring wells, just as in reality. However, in contrast to a real contaminated site, the true concentration distribution is known. By comparing the measured to the known true concentrations or other investigation results, the investigation strategy employed can be assessed and maybe improved. The integral groundwater investigation method (compare Fig. ), or integral pumping test method, is used here to quantify contaminant mass flow rates. The methodology has so far been applied at a number of study sites to estimate contaminant mass flow rates (Holder et al., 998; Bockelmann et al., 2; Bauer et al., 24), a study site based uncertainty investigation has been conducted by Jarsjö et al. (23) and new theoretical developments are given in Bayer-Raich et al. (24). In this approach, pumping wells positioned along control planes perpendicular to the

24 S. Bauer & O. Kolditz ) Conduct Pumpinglong tests term with pumping concentration tests with contaminant time series concentration measurements measurements Plot 2) Plot of concentration versus vs. time time during during the pumping tests test (compound specific) Contaminated site Well Control Plane C C C C C C C Well 2 Isochrones Well Well2 Well3 Well Well 2 Well 3 Source zone (Location generally unknown) Well 3 t t t t t t t t 2 2 3 t 2 Contaminant 4) Estimate contaminant mass flux mass and mean flow rate and mean concentration at the control concentration plane at control plane Transient 3) Use analytisal inversion inversion algorithm algorithm basedto on estimate a numerical the concentration flow and transport distribution in the aquifer model of the field site Fig. Schematic representation of the integral groundwater investigation method Reprinted from Bauer et al. (24) with permission from Elsevier, 24 Elsevier. groundwater flow direction are operated for a time period on the order of a few days and sampled for contaminants in the pump discharge (Fig. ). The concentration time series of the contaminants thus measured during operation of the pumping wells are then used to determine contaminant mass flow rates, mean concentrations and the plume shapes and positions at the control planes. This is performed by employing an analytical inversion methodology. In this work, the determination of mass flow rates by the integral groundwater investigation method is studied by using the Virtual Aquifer approach. A virtual reality is generated by simulating the spreading of a plume originating from a defined source in a heterogeneous aquifer. This plume is investigated using monitoring wells, and from these the location for a control plane for mass flow rate or concentration determination is obtained. Integral pumping tests are then virtually conducted along the control plane and the measurements during the pumping test, i.e. drawdown and the contaminant concentration time series, are evaluated to yield contaminant mass flow rates and average contaminant concentrations at the control plane. These values are then compared to the true concentration distribution and the true mass flow rate. METHODS First, two-dimensional aquifers of 84 m length and 64 m width are generated, which are discretized by m elements (Fig. 2(a)). Groundwater flows from left to right, driven by a hydraulic gradient of.3, induced by fixed head boundary conditions along the left and right hand side. The hydraulic conductivity is lognormally distributed with a mean of ln(k) = 9.54, corresponding to 7.2-5 m s -. The spatial distribution of the hydraulic conductivity is described by an isotropic exponential covariance model, using an integral scale of 2.67 m and a variance σ 2 Y of.7. The value for the integral scale stems from the Borden field site (Sudicky, 986), the variance was determined for a Quaternary alluvial aquifer in southern Germany (Herfort, 2). At a distance.5 m downstream of the upstream model boundary, a

Integral groundwater investigation method using the Virtual Aquifer approach 25 (a) fixed head boundary Contaminant source C =. no flow main ground water flow direction fixed head boundary c) (c) no flow (b) (d) d) Fig. 2 Schematic representation of the Virtual Investigation by Integral Pumping Test. a) Model setup and boundary conditions, b) Plume investigated by observation wells and interpolation, c) location and design of the integral pumping test in the investigated plume, and d) integral pumping test in the real plume. contaminant source is emplaced, emitting a non-reactive contaminant with source concentration.. Source width is between 4 and 2 m. Porosity is.33, local longitudinal and transverse dispersivities are m and. m. Thus the contaminant is transported with an average flow velocity of 6.5-7 m s -. The simulation code GeoSys (Kolditz & Bauer, 24; Kolditz et al., 24), which is based on the standard Galerkin Finite Element Method, is used to calculate the steady-state plume evolution. The evolved steady-state plume was investigated virtually using observation wells with a subsequent interpolation step, where the hydraulic heads and the concentrations found at the well locations were interpolated using kriging. The investigation steps: (a) placing new wells, and (b) interpolating the measured heads and concentrations were repeated, until the plume interpolation was found to be satisfactory (Fig. 2(b)). This plume interpolation was performed by a number of German scientists and hydrogeologists, and the task was to obtain a good plume investigation and interpolation by using any number of wells and interpolation steps. The results of the investigation are thus independent and yield individually and realistically investigated plumes. The interpolation results are used as the basis for the investigation of the integral pumping test method (Fig. 2(c)). Based on the interpolated plume, a control plane is placed perpendicular to the main plume axis 5 m downstream of the contaminant source with a width of 2 m. Thus location and width of the control plane to be covered by integral pumping test for mass flow rate determination are defined. Other possibilities for locating the control plane would be depending on concentration, i.e. cover all of the plume with concentrations larger than. of the source concentration. For this investigation, just one pumping test was used. From the (known) aquifer porosity n, the aquifer thickness m of m, the control plane width w and a pumping time t of 4.5 days the pumping rate Q needed to cover the given width can be calculated by: Q = πmnw t () 2

26 S. Bauer & O. Kolditz It is clear, that with increasing width of the control plane the pumping rate needed to achieve this width is increasing quadratically. In the next step (Fig. 2(d), the pumping test is conducted. The pumping well is placed in the middle of the control plane with the corresponding pumping rate. To achieve valid numerical results, the finite element mesh is refined around the well, with element sizes close to the pumping well of.5 m rising to element sizes of m at the control-plane ends. Small time steps of increasing size are used to simulate flow and transport in the evolving convergent flow field. In the pumping well, hydraulic heads and concentrations are recorded with time. Evaluation of the pumping test starts by determination of the hydraulic conductivity (Fig. 3(a)). The measured drawdown data and the Cooper-Jacob method are used here to determine the hydraulic conductivity. In the second step (Fig. 3(b)), the analytical solution of the inversion problem (Schwartz et al., 998; Bayer-Raich et al., 24) is used to estimate mass flow rates across the control plane. This is a simplification, as this analytical solution assumes homogeneous aquifer properties and a negligible hydraulic gradient within the maximum isochrone developed. The analytical solution uses the aquifer thickness, the hydraulic conductivity (determined from the drawdown data), the hydraulic gradient across the control plane (determined from nearby wells of the interpolated plume), the porosity and the pumping rate to yield an estimate of the average concentration within the well capture zone as well as an estimate of the contaminant mass flow rate. M and groundwater discharge across the control plane Q CP as well as the average concentration in the well capture zone C Av are related by: (a) Headinpumpingwell[m] 3 2 Head [m] Drawdown [m] 4 3 2 Drawdown Cooper - Jacob y =.248Ln(x) -.2556 R 2 =.9962 (b) Concentration in pumping well [mg/l] - - 9 9 29 39 49 Time [s] Time [s].9.8.7.6.4.3.2. 2 samples Concentration 2 3 4 5 Time [s] Inverted Concentration [mg/l].75.25 2 3 4 5 6 Length along control plane [m] Fig. 3 Schematic representation of the Virtual Investigation by an Integral Pumping Test. (a) head observation in the pumping well (left) and drawdown data with fitted line for calculation of K by the Cooper-Jacob method; (b) observed concentration time series and inverted concentrations in aquifer along control plane.

Integral groundwater investigation method using the Virtual Aquifer approach 27 M = Q C (2) CP Av The mass flow rate thus determined is compared to the true mass flow rate. The true mass flow rate is obtained from the results of the steady-state simulation prior to conducting the pumping test by adding up the local element mass flow rates along the control plane. This true mass flow rate thus accounts completely for the heterogeneity of the hydraulic conductivity. Additionally, the concentration distribution and the water flow rate along the control plane are calculated. RESULTS AND DISCUSSION Figure 4 summarizes the results of the assessment by the Virtual Aquifer approach of the integral groundwater investigation method. Shown are normalized values, i.e. the corresponding estimated parameter is normalized to the true value. For example, the normalized mass flow rate is the estimated mass flow rate divided by the true mass flow rate, and the better the estimate, the closer the shown value is to one (horizontal grey line). Figure 4 shows the results of the individual realizations as well as average values with standard deviations. As can be seen from Fig. 4, estimated mass flow rates deviate from the true mass flow rate. s may be overestimated by a factor of about 4 and underestimated by about a factor of 3. The same is true for the water flow rate, which shows a similar span of normalized values. Thus both mass flow rate and water flow rate show an uncertainty of more than one order of magnitude. normalized average concentration [], normalized maximum concentration []. Average Concentration Maximum Concentration. Average Concentration Maximum Concentration Fig. 4 Normalized results of the integral groundwater investigation, where values are normalized to their true values. The grey symbols denote the results from a single realization, the black symbols the arithmetic average and the error bars show one standard deviation.

28 S. Bauer & O. Kolditz Concentration in Aquifer [g/m3].4.3.2. Average Concentration 5.E-6 4.E-6 3.E-6 2.E-6.E-6 [g/s] and Water flow rate [m³/s] Concentration in Aquifer [g/m3].4.3.2. Average Concentration 5.E-6 4.E-6 3.E-6 2.E-6.E-6 [g/s] and Water flow rate [m³/s]. 2 25 3 35 4 Length along CP.E+. 2 25 3 35 4 Length along CP Fig. 5 Length profiles of concentration, mass flow rate and water flow rate along the control plane. Real values (left hand side) and values estimated by the inversion of pumping test data. The pumping well is positioned at 32 m, the control plane reaches from 22 to 42 m..e+ Determination of the average concentration is much more certain; the smallest estimated average concentration is.88, the largest.4. The maximum concentration within the largest isochrone during the pumping test is the parameter with the smallest uncertainty, the span ranges from.7 to.2. Mean and standard deviations for the mass flow rate, the water flow rate, the average concentration and the maximum concentration are.4 (±.9),.3 (±.),.7 (±. 7) and.92 (±.). Figure 5 shows a typical result of the investigation. In this case, the correspondence between estimated and true parameters is good. The left hand side shows the real (although virtual) values of concentration in the aquifer, the mass flow rate and water flow rate along the control plane, while the right hand side shows the values estimated by the above described procedure. The real aquifer shows fluctuations in water flow rate across the control plane of about a factor of, causing also local fluctuations of the mass flow rate, which is given by the product of local water flow rate and local concentration. The estimated water flow rate is homogeneous along the control plane, yielding a smooth profile of the estimated mass flow rate. In the case of Fig. 5, the water flow rate is slightly underestimated, however the concentration is overestimated towards the ends of the control plane, causing in total a slight overestimation of the mass flow rate by 7%. The estimated water flow rate is strongly influenced by the hydraulic conductivity determined by the long-term pumping test and the hydraulic gradient of the interpolated plume, as determined by the plume investigators. Both provide sources of error. As the correlation length of 8 m (corresponding to an integral scale of 2.66 m) is smaller than the size of the control plane by a factor of 2.5, the hydraulic conductivity determined from the pumping test may not be representative for the complete control plane. Both underestimation and overestimation of the hydraulic conductivity by up to a factor of was found in this study. This directly causes an underestimation or overestimation of the mass flow rate of the same factor (compare equation (2)). The hydraulic gradient also linearly influences the mass flow rate, but here the uncertainty is lower and deviations found were smaller than a factor of 3. Concerning the average concentration, overestimation occurs if the plume fringes are very sharp within the control plane. Underestimation occurs if the pumping well is

Integral groundwater investigation method using the Virtual Aquifer approach 29 not positioned within the plume centre and contaminated water is pumped only at the end of the pumping test. As is clear from Fig. 4, the dominating uncertainty is the uncertainty in water flow rate, stemming from uncertainty in determining the hydraulic conductivity and from uncertainty in interpolating the local hydraulic gradient across the control plane. In field applications, therefore, care should be taken to obtain a realistic representation of the hydraulic flow regime at and near the control plane. One of the possibilities would be to use multiple pumping tests along the control plane, thus yielding a better estimation of the hydraulic conductivity. Acknowledgements This work was funded by the German Ministry of Education and Research (BMBF) as part project 7. (Virtual Aquifers) of the KORA priority research initiative. REFERENCES Bauer, S., Bayer-Raich, M., Holder, T., Kolesar, C., Müller, D. & Ptak, T. (24) Quantification of groundwater contamination in an urban area using integral pumping tests. J. Contam. Hydrol. 75, 83 23. Bauer, S., Beyer C. & Kolditz, O. (24) Assessing measurements of first order degradation rates by using the Virtual Aquifer approach. In: Bringing Groundwater Quality Research to the Watershed Scale (ed. by N. R. Thompson) (Proc. Int. Conf. GQ 24, July 24, Waterloo, Canada), 274 287. IAHS Publ. 297. IAHS Press, Wallingford, UK. Bauer, S., Beyer, C. & Kolditz, O. (26) Assessing measurement uncertainty of first order degradation rates in heterogeneous aquifers. Water Resour. Res. 42, W42, doi:.29/24wr3878. Bayer-Raich, M., Jarsjö, J., Liedl, R., Ptak, T. & Teutsch, G. (24) Average contaminant concentration and mass flow in aquifers from time dependent pumping well data: analytical framework. Water Resour. Res. 4(8), W833, doi:.29/24wr395. Bockelmann, A., Ptak, T. & Teutsch, G. (2) An analytical quantification of mass fluxes and natural attenuation rate constants at a former gasworks site. J. Contam. Hydrol. 53(3 4), 429 453. Herfort, M. (2) Reactive transport of organic compounds within a heterogeneous porous aquifer. PhD Thesis, Tübinger Geowissenschaftliche Arbeiten 54, University of Tübingen, Tübingen, Germany. Holder, T., Teutsch, G., Ptak, T. & Schwarz, R. (998) A new approach for source zone characterization: the Neckar Valley study. In: Groundwater Quality: Remediation and Protection (ed. by M. Herbert & K. Kovar) (Proc. Int. Conf. GQ 98, September 998, Tübingen, Germany), 49 55, IAHS Publ. 25. IAHS Press, Wallingford, UK. Jarsjö, J., Ptak, T., Bayer-Raich, M. & Holder, T. (23) Uncertainties in contaminant plume characterisations based on concentration measurements in pumping wells: the Stuttgart-Neckartalaue site. In: Calibration and Reliability in Groundwater Modelling: A Few Steps Closer to Reality (ed. by K. Kovar & Z. Hrkal) (Proc. Int. Conf. ModelCARE 22, June 22, Prague, Czech Republic), 35 358. IAHS Publ. 277. IAHS Press, Wallingford, UK. Kolditz, O., de Jonge, J., Beinhorn, M., Xie, M., Kalbacher, M., Wang, W., Bauer, S., McDermott, C., Chen, C., Beyer, C., Gronewold, J., Kemmler, D., Manabe, T., Legeida, D. & Adamidis, P. (24) GeoSys Theory and Users Manual, release 4.. GeoHydrology / HydroInformatics, Center for Applied Geoscience, Universität Tübingen, Tübingen, Germany. Kolditz, O. & Bauer, S. (24) A process-oriented approach to computing multi-field problems in porous media. J. Hydroinformatics 6(3), 225 244. Schäfer, D., Dahmke, A., Kolditz, O. & Teutsch, G. (22) Virtual Aquifers : a concept for evaluation of exploration, remediation and monitoring strategies. In: Calibration and Reliability in Groundwater Modelling: A Few Steps Closer to Reality (edited by K. Kovar & Z. Hrkal), (Proc. Int. Conf. ModelCARE 22, June 22, Prague, Czech Republic), 52 59. IAHS Publ. 277. IAHS Press, Wallingford, UK. Schäfer, D., Schlenz B. & Dahmke, A. (24) Evaluation of exploration and monitoring methods for verification of natural attenuation using the virtual aquifer approach. Biodegradation J. 5(6), 453 465. Schwarz, R., Ptak, T., Holder, T. & Teutsch, G. (998) Groundwater risk assessment at contaminated sites: A new investigation approach. In: Groundwater Quality: Remediation and Protection (ed. by M. Herbert & K. Kovar) (Proc. Int. Conf. GQ 98, September 998, Tübingen, Germany), 68 7. IAHS Publ. 25. IAHS Press, Wallingford, UK. Sudicky, E. A. (986) A natural gradient experiment on solute transport in a sand aquifer: spatial variability of hydraulic conductivity and its role in the dispersion process. Water Resour. Res. 22(3), 269 282.