HRT 221 Greenhouse Structures and Management. John Biernbaum Department of Horticulture

Similar documents
Topics. Glazing Materials. Glass. Hail damage. Light transmittance through glazing material. Glass Rigid panels Film plastic.

Size: length ft., bay width ft., number of bays: Square feet of floor space: Sq. ft. of bench/floor space covered by crops:

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

SUNTUF Plus. Greenhouse Applications AGRICULTURE

Lexan* Thermopanel Sheet LTP30B4RS36. Property Profile Value Test Method. Lexan*

Hobby Greenhouses for NE Florida

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Heat Requirement Calculations for Greenhouses

Seasonal High Tunnel Systems for Crop Production (798) Update on interim standard

SOLEXX. Adaptive Plastics Inc.

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

RPR Insul-Mate Sheet and Roll Jacketing

EC The Effective Detective : Finding Energy Savings at Home

Exterior Perspective, East End

The most flexible, reliable, versatile and cost effective roofing material

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

MINIMUM SPECIFICATIONS

A. Source Limitations: Obtain each type of building insulation through one source.

RETROFIT INSULATION in WOOD ROOFS

ROOFS ROOFS WALLS FLOORS. Energy efficiency for constructions... Always environment-friendly...

AKRAPLAST Sistemi S.p.A. - I Novate Milanese (Mi) - via Cascina del Sole, 70 Tel: (+39) Fax: (+39)

H O Y L A N D E GREENHOUSES OFFER. Together skips all the obstacles We build according conditions, your requirments and European standards

Military Specifications

Skylights, Canopies, Walkways, Wall Systems & Interiors. Translucent Polycarbonate MULTI-WALL PANEL SYSTEMS

1 Exam Prep 2014 Florida Building Code -Energy Conservation Questions and Answers

Design & Construction Standards, Revised January

FULLBACK V PREMIUM SIDING INSULATION FOR VINYL

TOPCOAT System Specifications Corrugated Transite Panels

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Sealing a Crawlspace. Close the vents and let a heavy-duty vapor barrier keep moisture, mold and radon out of the living space BY LARRY JANESKY

Lock In Energy Savings For Life

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Selecting Energy Efficient New Windows in Tennessee

Selecting Energy Efficient New Windows in Nevada

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

SERIES DESCRIPTION MODEL PAGE

WaterproofingSystems. Roof Waterproofing with Thermoplastic Polyolefin Membranes

Selecting Energy Efficient New Windows in Illinois

Selecting Energy Efficient Replacement Windows in Arizona

Think Fiberglass First For Windows That Last!

Understanding Wind Uplift Ratings

MOISTURE CONDITIONS IN WALLS AND CEILINGS OF A SIMULATED OLDER HOME DURING WINTER

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

Crawl Space Moisture Control

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

Vinyl Replacement Windows and Doors

Insulating systems used in agricultural and industrial buildings

EXPERIENCE INOVO IN ACTION

WESTECK WINDOWS and DOORS

HI-PERFORMANCE REFLECTIVE INSULATION. The most versatile insulation CONTRACTOR INFORMATION AND INSTALLATION GUIDE

RS32 Multi-Section Skylight System under/over seam clip double diverter

American Architectural Manufacturers Association VOLUME 1 - WINDOWS AND DOORS

ATI Evaluation Service A Division of Architectural Testing Certification Services

Chapter 13 Renewable Energy and Conservation

3275 & 3275U, 3285 & 3285U Vertical Sliding, Double-Hung Windows

SPECIFICATION GUIDE SLIDING CLOSET DOOR PART 1 - PRODUCT

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

C H A P T E R 3. Completing the Residential Analysis Worksheet STEP 1: WINDOWS AND OTHER GLASS AREAS

TOTAL INSULATION ROOFS ROOFS WALLS WALLS FLOORS. Energy efficiency for construction projects Always in harmony with the environment.

Weatherproofing & Sealing Systems

Power Zone Center. Your solution for power distribution and control systems

THERMOHALL Insulated Buildings

Smart Vapor Retarders

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

Note: Any verbiage written in red needs to be specified. All other options should be deleted

ACOUSTICAL DUCT & PIPE LAGGING INDUSTRIAL NOISE CONTROL PRODUCTS

Techna-Duc. Advantages. Features and Benefits. LEED Eligible Product

Structural Vacuum Insulation Panels

Analysis 2: Alternative Thermal Window Design

Air and Vapor Barrier 3015

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

Section BUILDINGS, SHELTERS, ENCLOSURES

Getting Technical with Fabric Structures

RS24-10 Single-Section Skylight System

Project s fiche INOV. Frisomat Case study project's fiche INOV

A. Access doors and frames are part of an access door and frame allowance.

Lexan* Thermoclear* Plus 9 wall Sheet

Product information Vertical window element VFE

Flexible Vapor Control Solves Moisture Problems of Building Assemblies - Smart Retarder to Replace the Conventional PE-Film

Insulation Technologies and Installation Specifications for Better Energy Performance of Commercial Buildings

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

Insulated Glass Units

JL Fire Vents - Guide Submittal / Specifications

EcoTouch Insulation with PureFiber Technology

Page 1. Energy Saving skylights. PolyCarbonate Panels

Georgetown Series windows and doors are designed not only for beauty, comfort, and energy-efficiency they re also virtually maintenance-free.

Insulated Tempered. Model Glazing Tape Page

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

Stadtwerke Konstanz Customer Centre, Constance

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

LANE ENTERPRISES, INC. STANDARDS & SPECIFICATIONS

TUNNELS III.

Transcription:

HRT 221 Greenhouse Structures and Management John Biernbaum Department of Horticulture

Topics for Week 4 Review types of Structures Alternative or less common types Functional Features & Design Criteria Structural Materials Greenhouse Coverings Selection criteria Materials

Alternative Greenhouses Sawtooth Only found in warm climates without snow like southern Florida. Designed to capture wind for cooling, to reduce light and limit rain/water on foliage plants for indoor use.

Old greenhouse for botanical collection. Near the San Francisco Bay Bridge.

Geodesic dome for botanical collection.

Other Types of Greenhouses Gothic Pit or in ground Air inflated

Standardization National Greenhouse Manufactures Association http:/www.ngma.com Published Guidelines Not all Companies are members

Function: Strength Dead Load Structure and long term weight Live Load Short term weight (15 lbs/sq ft floor) Snow load 15 lbs/sq ft of floor minimum Wind load Lateral and lifting forces to resist 80 mph wind Foundation Vertical, horizontal and lifting forces.

Structure and Light Orientation covered previously Roof slope 35 degrees preferred 26 to 28 (6:12 slope) degrees common Minimize structural members to minimize shading Also minimize equipment

Structure and Climate Condensation and snow removal Pad/vent to fan distance (100-200 ) Passive ventilation Vents, end walls, side walls Heating efficiency Surface area to floor area Infiltration or air leakage rate

Working Height Gutter height has increased from as low as 8 to 10 to 12 as common and 14 for some structures. Impact of higher gutter: Improved working environment Greater air mass reduces rapid temperature fluctuations Equipment movement in greenhouse

Floors Humidity Management Dry floors reduce humidity Crop movement by carts, etc Prevention of runoff to groundwater Minimize application is best prevention Cost of Cement is an issue

Structural Materials Strength Weight Durability Maintenance Cost Initial Long term

Structural Materials Wood Availability, treatment, maintenance Steel Galvanized Most common material (Gatorshield( Gatorshield) One steel company supplies most of the greenhouse manufacturing companies Avoid reactive chemicals fertilizer Aluminum Light weight, strong, low maintenance High cost; used for glass.

Coverings: Cost Selection Criteria Initial and annual Glass - $1.00 to $2.00/sq ft (surface) lasts 20+ years Plastic at $0.10/sq ft x 2 layers x 5 replacements in 20 years = $1.00/sq ft +labor Structure, heating and light differences must also be considered.

Coverings: Selection Criteria Life Expectancy Photodegradation is the primary breakdown of plastics Greenhouse plastics have UV or ultraviolet stabilizers needed for multiyear use Oxidation Surface erosion

Coverings: Selection Criteria Strength and Weight Structural support weight varies Dead load Shattering resistance to breakage by rock, hail, etc Crazing star like cracks at point of impact reduces light diffusion Tensile strength resistance to tearing

Light Transmission: Light Reflected Transmitted Absorbed heat energy Indirect or Diffused Direct

Definitions Transparent Translucent Opaque Direct light Diffuse light

Light Transmission Amount passing through (inside) X 100 = Percent Light Transmission Amount of light at Surface (outside)

Thermal Qualities Expansion and contraction Plastic films from winter to summer Rigid plastic sheets Heat retention conductance Thermal radiation Infrared or long wave radiation Glass opaque, plastic file transparent Plastic films can have IR additives

Other Factors Flammability Insurance Shading How is light reduced? Taxes Heating and Fuel Costs Labor to change plastic film

Coverings Glass Rigid Structured Sheets Fiberglass Polycarbonate Acrylic Films polyethylene

Types of Glass Float Glass ($0.60/sqft) (Nelson Prices) Single strength (homes) double for greenhouses Shatters into sharp shards Tempered Glass (($0.75/sqft) Stronger Shatters to small pieces Laminated tempered Glass ($4.00 sq ft) Low iron tempered Glass ($0.85/sqft) Hammered Glass diffuses light

Older structures had many small panes or lites of glass That required more sashbars and sealing. New structures have larger pieces of glass.

One piece of glass from gutter to ridge.

Glass Characteristics Light Transmission One of the highest 88% to 92% Strength Cost Initial high, justified for high light crops Thermal Properties Single layer, high conductance Needs a thermal blanket

Rigid Structured Sheets Polyvinylchloride (PVC) at Home Depot Not recommended short life Fiberglass Being replaced with polycarbonate or acrylic Polycarbonate Less rigid, able to curve more Lower price, flame resistant, less hail damage Acrylic Higher price, flammable, hail damage

Rigid Structured Sheets Forms Single layer flat Single layer corrugated Double layer ribbed 8 mm - $1.90 16 mm - $2.60 Aluminum extrusion to hold costs an additional $1.50 per sq ft of panel

Corrugated Fiberglass Panels Diffuses light

Not available in double layers so low insulation and heat retention value. Fiberglass Bloom: resin wears away exposing the fibers. Collects dirt and reduces light.

Double Layer Polycarbonate or Acrylic

Attaching Panels Thermal expansion and contraction requires special mounting.

Large Roof Panels

Sheet Characteristics Light Transmission Depends on thickness and type high 88% to 92% Strength good except crazing Cost Initial high, justified for high light crops Thermal Properties Single layer, high conductance Double layer provides good insulation

Polyethylene Films Many sizes (widths) available Length typically 100 or 150 3 to 4 years longevity Longer with lower light 6 mil (0.006 inch) thick Typically used as an air inflated double layer for the insulation and structure

Inflation Fans

One Large Fan Distributed

Moisture Between Layers

Pressure Between Layers Manometer to measure pressure ¼ inch difference in loop Effects resistance to wind Too much pressure stresses film

Polyfilm over glass was investigated at Penn State around 1980. Light reduction reduced yield of roses more than money saved.

Reduce energy loss of end walls. Triple layer in spring for condensation drip reduction. Not really used.

Film Options Polyvinyl chlorides, polyvinyl fluorides, polyesters Only narrow widths available Some longer life films being tested. Infrared additives Anticondensate additives Light diffusing additives

Greenhouses do get damaged and destroyed Wind damage Snow Damage

Next On Schedule Light and Lighting Systems Benches (Wednesday, 9/29) First Exam (Friday, 10/1)