Custom Polishing Systems

Similar documents
SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

SECTION EPOXY TERRAZZO

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

The American Society of Concrete Contractors Concrete Polishing Council SECTION BONDED ABRASIVE POLISHED CONCRETE FLOORS

KOSTER AMERICAN CORPORATION

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

1.1 Related Work Specified in Other Sections (Delete if Not Applicable):

for Mortar-Set Concrete Tiling Installations

SECTION CONCRETE PAVING SLABS SET IN MORTAR

Section Polished Concrete Finishing. Vexcon

International Polished Concrete Institute November 2006 Toll Free (866) Website

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

SECTION EPOXY FLOORING SYSTEMS

Florock Seamless Flooring Systems

RESILIENT FLOORING: Select Step Wood

Ash Brook Golf Course Scotch Plains, New Jersey

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

1. Rapid Set Cement. 2. Methods of preparation. 3. How to stage a job site. 4. Installation Mix, place, finish. 5. Coloring the TRU.

CONCRETE & STAINING TECHS SIMPLY WARRANTY

SECTION HYDRAULIC CEMENT UNDERLAYMENT

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

RESILIENT FLOORING: Hot and Heavy - Secoya

***********************************************************************************

SUPER-KRETE SPECIFICATION S-1 EXISTING CONCRETE SURFACE PREPARATION SECTIONS ; /19; ;

SECTION EPOXY TERRAZZO

CEMENTITIOUS CRYSTALLIZING WATERPROOFING PART 1 GENERAL

RESILIENT PHOTOLUMINESCENT STAIR TREADS

SECTION RESILIENT SHEET FLOORING

PRODUCT SPECIFICATIONS

ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound

GUIDE SPECIFICATION

SECTION CONCRETE AND MASONRY COATINGS

Specifier Notes: Edit the following list as required by the project. List other sections with work directly related to the floor coating.

SECTION A. American Society for Testing and Materials (ASTM):

ARDEX GUIDE SPECIFICATION

DECORATIVE EXTERIOR FINISHING

SECTION CAST-IN-PLACE CONCRETE

Sample Specification Guideline for Installing a Polished Concrete System Using Rapid Set TRU PC SECTION POLISHED CONCRETE TOPPING

SECTION ULTRACOMPACT WALL FINISHES - THIN SET

Narrow Modular Pavers (NMP) for Sand-Set Installations

Section COATING RESTORATION

SECTION SITE CONCRETE

SECTION TILING

ARDEX GUIDE SPECIFICATION ARDEX PC-T POLISHED CONCRETE TOPPING Part of the ULTRAFLOR ARDEX DIAMATIC Polished Concrete System

Kolorines Glass Mosaic Tiles Project Specification

GUIDE SPECIFICATION

2018 Flooring Specification - Tile Set Method TECTURA DESIGNS CEMENT TERRAZZO TILES

CONDUCTIVE RESILIENT FLOORING

TILE TILE

SECTION PREFINISHED FSC MAPLE FLOORING. This is a template: edit this specification carefully to suit specific project requirements.

System Specifications

prospec.com Concrete Repair & Restoration

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.

SECTION GYPSUM CEMENT UNDERLAYMENT RECOMMENDED SPECIFICATION FOR DURA-CAP FLOOR UNDERLAYMENT OVER EXTRUDED OR EXPANDED POLYSTYRENE FOAM

GUIDE SPECIFICATIONS For STRUCTURAL PRECAST HOLLOW CORE SLABS SECTION 03410

SECTION RESINOUS MATRIX TERRAZZO FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION COMMON WORK RESULTS FOR CONCRETE SSPECIALTY COATINGS

By CTS Cement Manufacturing Corp.

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

TOPCOAT Restoration Specifications Structural Concrete

SECTION POLYACRYLATE MODIFIED CEMENTITIOUS TERRAZZO FLOORING

A. Section includes cast-in-place concrete, including formwork, reinforcement, concrete materials, mixture design, placement procedures, and finishes.

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

Engine Bay Floors Floor Resurfacing 4000

Editing notes to assist users are separated from specification text by rows of asterisks. Delete these notes prior to final printing.

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

SECTION Pedestrian Traffic Coatings{PRIVATE } 1.1 SUMMARY (Specification writer shall add, delete or amend, as deemed necessary)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

PRODUCT GUIDE SPECIFICATION

SECTION LATEX-MODIFIED MEDIUM BED MORTAR

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

DIVISION 9 - SECTION QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

SPECIFICATION GUIDELINE

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

B. All work of the section shall comply with the conditions of the contract, the drawings and any special conditions forming a part of the contract.

Tolerances- Section

SECTION WOOD FLOORING

CHATTANOOGA, TN Last Updated: 04/12/17. NOTE TO SPECIFIER: Be sure to obtain the latest version of this Guide Specification.

SECTION WOOD FLOORING. 1. Section Above-Grade Vapor Retarders. 2. Section Below-Grade Vapor Retarders

CSI GUIDE Countertops

Product Guide Specification

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

Resilient and Wood Floor Covering Flatness Requires High Performance, Cementitious Self-Leveling Underlayment

Fundamentals of Concrete

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring

Cutting Edge Solutions Using Advanced Self Leveling Materials. ICRI National Convention April 14, 2010

Application Specification:

TECHNICAL SPECIAL PROVISION FOR CONCRETE REPAIRS. Financial Project ID , &

INSTRUCTIONS FOR EDITING AND COORDINATION SECTION WOOD FLOORING - ATHLETIC

Vinyl Rx GUIDE SPECIFICATIONS Ecore Commercial

SECTION EXPANSION CONTROL

Regupol Aktiv RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER

Sections Paver Tiling Guide Specification; for installation of Marion Ceramics, Thin Brick Tiles; Flooring, Veneer

MS-2A LINER SPECIFICATIONS: for STRUCTURAL REPAIR and SEALING of MANHOLES

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

Specifiers Guide to Polished Concrete in Greater Kansas City

WOOD FLOORING WOOD FLOORING

Transcription:

Custom Polishing Systems VitraFlor by Bomanite Guideline Specification Standard Application PART 1 GENERAL SECTION 033000 CAST-IN-PLACE CONCRETE 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this section. 1.2 SUMMARY A. Work specified in this section includes all labor, materials, equipment and services necessary to complete the VitraFlor by Bomanite Custom Polishing System including curing compounds, appropriate suface preparation, concrete densifiers and stain-resistant treatments. B. Related Sections include the following: 1. Division 1 Section Product Requirements for submittals and substitutions. 2. Division 3 Section Curing Compounds for concrete slabs. 3. Division 3 Section Joint Sealers Installation of caulking. 1.3 SUBMITTALS A. Product Requirements: 1. Provide submittal information within 35 calendar days after the contractor has received the owner's notice to proceed. B. Product Data: 1. Submit special concrete finishes manufacturer s specifications, test data and other data required for each type of manufactured material and product indicated. 2. Submit special concrete finishes technical bulletins listing manufacturer s name, product name and descriptive data, curing time and application requirements. 3. Submit special concrete finishes manufacturer s Material Safety Data Sheet (MSDS) and other safety requirements. 1.4 QUALITY ASSURANCE A. Installer Qualifications: The contractor for this work shall be a licensed Bomanite Custom Polishing Licensed Contractor and Certified Applicator trained and equipped by The Bomanite Company (303) 369-1115.

1. Provide letter of certification from The Bomanite Company stating that installer is a certified applicator of special concrete finishes and is familiar with proper procedures/installation requirements of the manufacturer. 2. Use an authorized Bomanite Licensed Contractor and adequate number of skilled workmen who are thoroughly trained and experienced in the necessary craft. 3. Applicator shall be familiar with the specified requirements and the methods needed for proper performance of work of this section. 4. Applicator shall be familiar with the previously approved mockups that demonstrated standard of workmanship. 5. Authorized Bomanite Custom Polishing Systems installers limited to the following: a. Colorado Hardscapes, Inc. 8085 E Harvard Ave Denver, CO 80231 303-750-8200 B. Manufacturer Qualifications: A firm experienced in the support and training of a national installer network and manufacturing products required/listed to complete the work. 1. The Bomanite Company 303-369-1115 no equal C. Source Limitations: 1. Concrete: Obtain each type or class of cementitious material of the same brand from the same manufacturer s plant, obtain aggregate from one source and obtain admixtures from one source from a single manufacturer. D. Mock-ups: 1. Apply each type finish to mock-ups to demonstrate typical joints, depth of grind, color variation (if any) and standard of workmanship. a. Mock-up shall include entire system, including specified concrete mix, depth of grind, hardening chemicals and surface treatments. b. Notify Architect or Owner Representative seven days in advance of dates and times when mock-ups will be constructed. c. Obtain from the Architect or Owner Representative approval of mock-ups before starting construction. d. If the Architect or Owner Representative determines that the mock-ups do not meet requirements, General Contractor will demolish and remove them from the site and cast others until mock-ups are approved. e. Maintain mock-ups during construction in an undisturbed condition as a standard for judging the completed work. 1.5 DELIVERY, STORAGE AND HANDLING A. Deliver materials in original packages and containers, with seals unbroken, bearing manufacturer labels indicating brand name and directions for storage, mixing with other components and application.

B. Store materials to comply with manufacturer s written instructions to prevent deterioration from moisture or other detrimental effects. C. Dispense special concrete finish material from factory numbered and sealed containers. Maintain record of container numbers. 1.6 PROJECT CONDITIONS A. Environmental Limitations: 1. Comply with manufacturer s written instructions for substrate temperature and moisture content, ambient temperature and humidity, ventilation and other conditions affecting installation performance. 2. Concrete must be cured a minimum of 28 days or as directed by the manufacturer before application of Bomanite Custom Polishing can begin. B. Close areas to traffic during and after floor application for time period recommended in writing by licensed installer. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. In other Part 2 articles where titles below introduce products, the following requirements apply to product selection: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering materials decorative in nature required to be incorporated into the work include, and are limited to, manufacturer listed. a. Colorado Hardscapes 8085 E. Harvard Ave Denver, CO 80231 Tel: (303) 750-8200 Fax: (303) 750-8886 2.2 MATERIALS A. Bomanite Stabilizer Pro: Proprietary water based liquid hardener based on Lithium Silicate with Silane additives containing no VOC s applied at three points of the installation process formulated to chemically harden and improve the density of concrete surfaces. B. Bomanite Stain Guard: Proprietary water based liquid hardener with additional stain resistant properties based on Lithium Silicate and Methacrylate additives containing <50 g/l VOC applied as the final step of the installation process formulated to chemically harden and improve the stain resistance of interior concrete surfaces. C. Patching materials: Bomanite GFRC Facing Mix no equals accepted. Trowel or spray applied mortar based on Type II Portland cement blended with Calcium Aluminate cement modified with Styrene Butadiene polymer designed to bond to prepared concrete and cure rapidly in order to aid grinding production. D. No substitutions or alternates to the above will be accepted.

E. Related Materials. 1. Bomanite Clear Cure: A water based acrylic sealer containing <250 g/l VOC designed to bond to fresh concrete and meet ASTM C-309 membrane curing standards while being compatible with the Bomanite Custom Polishing processes. 2. Hi-Tech Structural Systems Polyurea Joint Filler HT-PE85: A two component rapid curing polyurea joint filler containing <70 g/l VOC designed to fill and support the sawed joints in a concrete slab while being compatible with the Bomanite Custom Polishing processes. 1-800-454-5530 3. No substitutions or alternates to the above will be accepted. 2.3 CONCRETE A. Portland cement: shall conform to ASTM C 150, Type I, II or V. B. Aggregates: shall conform to ASTM C 33. C. Water: Mixing water shall be fresh, clean and potable. D. Air Entrainment: No air entrainment is to be used in the concrete mix design. E. Water-Reducing Admixtures: Water-reducing admixtures are permitted and shall conform to ASTM C 494. F. Pozzolans: Fly Ash conforming to ASTM C618 type F or Blast Slag conforming to ASTM C989 is required for use in the concrete mix design. 2.4 CONCRETE MIX SPECIFIC TO BOMANITE VITRAFLOR REQUIREMENTS A. Requirements: 1. Slump: 4 to 6 inch slump. Obtain approval from Owner s Authorized Representative if slump is outside these parameters. 2. Minimum PSI Rating: 28 days @ >3,000 psi with 60 days @ >4,000 psi. 3. Cement quantity per yard of mix: a. Minimum: 5 sacks. b. Maximum: 7 sacks. 4. Water/cement ratio: Maximum.6. 5. Aggregates: Use maximum topsize aggregate with lowest paste content possible. 6. Admixtures: Mid range water reducers recommended. 7. Fly ash or Blast Slag: Use in all applications possible up to 40% cement content. 8. Accelerators: Do not use accelerators. 2.5 CONTROL JOINTS A. Form weakened-plane contraction joints, sectioning concrete into areas as indicated with power saws equipped with shatterproof abrasive or diamond-rimmed blades. B. Cut 1/8 to 1/4-inch-wide joints into concrete when cutting action will not tear, abrade, or otherwise damage surface and before concrete develops random contraction cracks.

C. Construct control joints for a depth equal to at least one-third of concrete thickness. PART 3 - EXECUTION 3.1 PRECONSTRUCTION PLANNING A. Consult General Contractor, Structural Engineer, Architect and Concrete Contractor prior to installation of concrete slab to ensure complete understanding of substrate preparation, reinforcement, penetrations, mix design, placing and finishing requirements, etc. B. Verify that the concrete slab will meet a minimum of 3,000 psi of compressive strength and has a minimum flatness rating of F35 as per ASTM E1155 see supplemental Bomanite Custom Polishing Standard FF/FL Floor Tolerance Specification. Consult American Concrete Institute ACI302.IR-89, Guide for Concrete Floor and Slab Construction requirements in Division 3 Section "Cast-In-Place Concrete," and Project Conditions. C. Confirm that the General Contractor through coordination with other trades will be responsible for the protection of the slab during construction to ensure that no contaminants such as (but not limited to) oil, grease, paint, adhesives, flux, etc will be present at the time of concrete polishing. 3.2 EXAMINATION OF SLAB PRIOR TO APPLICATION A. Examine substrate, with installer present, for conditions affecting performance of finish. Rectify conditions detrimental to timely and proper work. Do not proceed until unsatisfactory conditions are corrected. B. Verify that base slab meets finish and surface profile requirements in Division 3 Section "Cast-In-Place Concrete," and Project Conditions above. C. Prior to application, verify that floor surfaces are free of construction damage and contaminants. D. Repair of defective concrete due to improper installation is the Polishing Concrete Contractor s responsibility. Removal and replacement of concrete that cannot be repaired and patched to Architect s approval is the Concrete Contractor s responsibility. The determination of whether the concrete can be repaired or must be removed and replaced is the General Contractor s to make with the knowledge that adequate cure time of replaced sections must be allowed prior to commencing the grinding, staining and polishing process.

3.3 INSTALLATION OF POLISHING PROCESS A. Construction Process: 1. Apply specialty hardening and polishing process in accordance with manufacturer s proprietary, internal application procedures. a. VitraFlor by Bomanite Exposure of aggregate: Concrete to be ground to a full sand exposure with minimal top size aggregate exposure (minimum starting grit of 150 metal bond) and polished to 3,000 grit. b. Concrete must be in place to reach an adequate strength to begin polishing without experiencing fine aggregate loss from the initial grinding process or as directed by Bomanite before application can begin. c. Control joints to be filled with Polyurea and shaved prior to the grinding and polishing process. d. Application is to take place and be completed prior to racking and other in-store furniture and cabinetry installation, thus providing a complete, un-inhibited concrete slab for application. e. Only a certified applicator shall install Bomanite VitraFlor. Applicable procedures must be followed as recommended by the product manufacturer and as required to match approved test sample and achieve required properties. 3.4 PROTECTION A. General: Protect finished work from traffic until fully cured in accordance with manufacturer s recommendations. END OF SECTION 033000