Confocal Microscopy Analyzes Cells

Similar documents
Spectral Separation of Multifluorescence Labels with the LSM 510 META

Welcome! openmicberkeley.wordpress.com. Open Berkeley

Simultaneous multi-color, multiphoton fluorophore excitation using dual-color fiber lasers

Monitoring and Optimizing the Lipopolysaccharides-plasmid DNA interaction by FLIM-FRET

Confocal Microscopes. Evolution of Imaging

Comparison of LANCE Ultra TR-FRET to PerkinElmer s Classical LANCE TR-FRET Platform for Kinase Applications

Challenges to measuring intracellular Ca 2+ Calmodulin: nature s Ca 2+ sensor

Partha Roy

Flow Cytometry - The Essentials

NovoCyte Flow Cytometer

3D Laser Lithography in Biotechnology and Medical Technology

Exam MOL3007 Functional Genomics

QImaging Camera Application Notes Multicolor Immunofluorescence Imaging

Photon Upconversion Sensitized Nanoprobes for

Introduction to Fluorescence Jablonski Diagram

CytoPainter Golgi Staining Kit Green Fluorescence

FLUORESCENT PEPTIDES. Outstanding Performance and Wide Application Range

TWO-PHOTON EXCITED FLUORESCENCE OF THE LENS FOR THE DIAGNOSIS OF PRESBYOPIA

Multiphoton Microscopy: Seeing deeper and clearer

Direct visualization, sizing and concentration measurement of fluorescently labeled nanoparticles using NTA

Chapter 10 Analytical Biotechnology and the Human Genome

How to perform-control immunostaining experiment - microscopist subjective point of view. Pawel Pasierbek

Super-resolution Microscopy

Innovations To Meet Your Needs

CENTER FOR BRAIN EXPERIMENT

1. A brief overview of sequencing biochemistry

Resolution of Microscopes Visible light is nm Dry lens(0.5na), green(530nm light)=0.65µm=650nm for oil lens (1.4NA) UV light (300nm) = 0.13µm f

Chapter 4 Fluorescence Resonance Energy Transfer (FRET) by Minor Groove-Associated Cyanine-Polyamide Conjugates

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

Applicability of Hyperspectral Fluorescence Imaging to Mineral Sorting

Nature Methods: doi: /nmeth Supplementary Figure 1. Retention of RNA with LabelX.

Practical light microscopy: an introduction

Lecture 13: Analysis of 2D gels

Automated Imaging and Dual-Mask Analysis of γh2ax Foci to Determine DNA Damage on an Individual Cell Basis

Performance of the Micro Photon Devices PDM 50CT SPAD detector with PicoQuant TCSPC systems

Azure Biosystems Western Blotting Workflow

Application of Quantum Mechanics to Biology

CBI Toolbox Tour 2015

Diffraction Contrast Tomography. Unlocking Crystallographic Information from Laboratory X-ray Microscopy. Technical Note

Bioinstrumentation Light Sources Lasers or LEDs?

Introduction to N-STORM

AFM-Raman Characterization of Pharmaceutical Tablets

Next Level of Super Resolution Fluorescence Microscopy

Fluorescence Nanoscopy

a Beckman Coulter Life Sciences: White Paper

Orflo Application Brief 3 /2017 GFP Transfection Efficiency Monitoring with Orflo s Moxi GO Next Generation Flow Cytometer. Introduction/Background

Technical Review. Real time PCR

See what s really in your sample

Genetically targeted all-optical electrophysiology with a transgenic Credependent

Three-Color Spectral FRET Microscopy Localizes Three Interacting Proteins in Living Cells

Lighting research Toulouse team (France) Ludovic VANQUIN Ikbal MARGHAD Lydie AREXIS BOISSON

FLOW CYTOMETRY. CyAn ADP. Analyzer

APPLICATION NOTE Rev. 7/2017, v4.0 Fluorescent Nanodiamonds: Bio-applications. Physical and Fluorescence Properties

SAPIENZA Università di Roma Laurea magistrale in Ingegneria delle Nanotecnologie A.A Biophotonics Laboratory Course

Qdot nanocrystal. wide range of biological investigations, Qdot nanocrystals are powerful complements

Cationic Vector Intercalation into the Lipid Membrane Enables Intact Polyplex DNA Escape from Endosomes for Gene Delivery

Lecture Four. Molecular Approaches I: Nucleic Acids

CHEMOMETRICAL ANALYSIS OF ENDOMETRIAL TISSUE FLUORESCENCE SPECTRA

!! PLEASE READ BEFORE USE!!

ADVANCED PRACTICAL COURSE IN BIOPHYSICS: FRET

Boundary-breaking acoustic focusing cytometry


BioScope Catalyst Life Science Atomic Force Microscope

DeltaPro. DeltaFlex FORENSICS PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Using ULS24 CMOS Bio-imager as a Readout Sensor for Chemiluminescence Immunoassay and DNA Hybridization Assay

Flow Cytometry. Flow Cytometry Basics Guide

Final exam. Please write your name on the exam and keep an ID card ready.

CyFlow Cube series Appealing from every angle

Flow Cytometry. Cell Sorting 34 Instruments 34 Consumables 38

Recent technology allow production of microarrays composed of 70-mers (essentially a hybrid of the two techniques)

Chapter 10: Classification of Microorganisms

Single-Molecule FISH. Single-Molecule Fluorescence Resonance Energy Transfer. Synonyms. Definition. Photophysical Basis of smfret.

Imagerie et spectroscopie de fluorescence par excitation non radiative

Masayoshi Honda, Jeehae Park, Robert A. Pugh, Taekjip Ha, and Maria Spies

Lecture #1. Introduction to microarray technology

The Raman effect, discovered in 1928 by C.V. Raman in his

Methods of Biomaterials Testing Lesson 3-5. Biochemical Methods - Molecular Biology -

Chapter 1 Nanophotonics and Single Molecules

Towards Probing Skin Cancer using Endogenous Melanin Fluorescence

Notes to accompany the slidecast on theory of SDS PAGE and Western blotting

University of Groningen

Onsite FTIR quantitative analysis of water in mineral-based oils using a novel water stabilization technique

Biochemical Analysis The Lambda Series UV/Vis Spectroscopy

SIL-based confocal fluorescence microscope for investigating individual nanostructures

Franzens-Universitaet Graz, Humboldtstrasse 50, 8010 Graz. Phone: ++43 (0) Fax: ++43 (0)

Fundamentals and Applications of Biofilms Analysis, Structure and Physiology of Bacterial Biofilms Ching-Tsan Huang ( 黃慶璨 ) Office: Agronomy

Roche Molecular Biochemicals Technical Note No. LC 10/2000

determine optimum instrument settings for their own instruments and establish their own daily values.

AURORA AIRY BEAM LIGHT SHEET IMAGING SYSTEM THE CUSTOM DEVELOPMENT PROGRAMME

Reading for lecture 11

Lecture 8: Sequencing and SNP. Sept 15, 2006

SI8000 Live Cell Imaging System

LUPAS Luminescent Polymers for in vivo Imaging of Amyloid Signatures

Life Tein. Understanding Life One Protein at a Time... Modifications of peptides

Fs- Using Ultrafast Lasers to Add New Functionality to Glass

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

A Survey of Laser Types. Gas Lasers

Live Specimen Microscopy

Return to Web Version

Transcription:

Choosing Filters for Fluorescence A Laurin Publication Photonic Solutions for Biotechnology and Medicine November 2002 Confocal Microscopy Analyzes Cells Reprinted from the November 2002 issue of Biophotonics International Laurin Publishing Co. Inc.

Confocal Microscopy Reveals Molecular Interactions by Dr. Richard Ankerhold and Dr. Bernhard Zimmermann SUMMARY When and where specific proteins interact with each other is the central question that needs to be resolved to gain a better understanding of their function. Confocal laser scanning microscopes can support key approaches to the study of functional interactions of biomolecules. In living cells, protein activity often depends on their association in a complex of several molecules. For example, the replication of chromosomes prior to cell division requires the cooperation of proteins such as DNA polymerases, helicases and ligases to build the replication machinery. Furthermore, most enzymes need to interact with co-factors to become active. For instance, protein kinase C is a crucial enzyme that influences a great number of cellular processes, including secretion, cell growth and differentiation. The interaction of the kinase with specific lipid co-factors is essential for the regulation of its activity. To study when and where proteins associate with each other, scientists commonly label them with different fluorophores and subject them to fluorescence microscopy. Labeling can be either indirect, by using fluorescently labeled antibodies that are directed against the protein of interest, or direct via conjugation between protein and fluorophore. A popular method for the latter approach is the Figure 1. Individual pinholes in front of every detector (P1-P4), including the Meta detector, allow the user control of confocal slice thickness for each channel.

genetic engineering of fusion proteins composed of the protein of interest and green fluorescent protein (GFP) or its variants. The fusion construct can then be expressed in cells, tissues or even whole animals. A major advantage of confocal methods over conventional fluorescence microscopy is the ability to optically section cells and tissue in three dimensions without mechanically disrupting the structure of interest. In addition, a laser scanning microscope allows the user to fully control the depth of focus and eliminate unwanted light from out-of-focus areas. Quantitative collocalization assays, fluorescence resonance energy transfer (FRET) microscopy and fluorescence correlation spectroscopy are all techniques that can be used where confocal methods are beneficial or essential to investigate the functional interaction of molecules. Figure 2. A confocal image of a 6-day-old zebra fish (dorsal view) embryo that has been double-labeled with antibodies against cell adhesion molecules shows staining of different subpopulations of axons in the nervous system. Yellow indicates areas of collocalization, while other axons show either green or red fluorescence. Courtesy of M. Marx, University of Konstanz, Germany, and M. Bastmeyer, University of Jena, Germany. Identifying collocalization In collocalization experiments, the coincidence of two fluorescently labeled proteins in the same spot is indicative of their potential interaction. Hereby, confocal technology virtually excludes the possibility of false-positive observations that can result from the low depth of focus of conventional fluorescence microscopy. Collocalization studies require identical dimensions for the detection volumes from which the two signals are collected. Most importantly, the confocal sections must exhibit identical thicknesses; otherwise, the reconstructed 3-D image will show overlapping parts that do not overlap in reality. Also, the two fluorescent signals indicating the position of the proteins must be completely and unambiguously separated, each in its own imaging channel. Finally, the method requires advanced software functions specialized for quantitative analysis of the collocalization data. This may sound simple, but it is not. The thickness of confocal image slices depends upon the excitation and emission of the dyes used, as well as on the size of the confocal pinhole; the pinhole can help compensate for differences in slice thickness that result from different-colored dyes. However, this requires a multipinhole system, so that the user can adjust the optical slice thickness for each color/detector individually. The LSM 510 series from Carl Zeiss provides the required architecture with individual motorized pinholes in front of every detector and automatic adjustment routines (Figure 1). The software allows the researcher to adjust the pinholes of each confocal channel to the same optical thickness, independent of the color. Complete separation of the fluorescent signals requires careful selection of the fluorescent dyes for a collocalization experiment. Because of the spectral properties of dyes, the emission of one dye typically overlaps the emission of the second. This effect is present in most combinations of fluorescent dyes, even for the classical combination of FITC and rhodamine. Simultaneous excitation and detection of these dyes causes the green fluorescence emission to contribute to the detection of the red, a phenomenon known as crosstalk. One solution implemented in the microscope, multitracking, allows the user to alternate between excitation lines in an extremely fast manner that can be applied to livecell measurements. This procedure can minimize crosstalk and may even eliminate it if the excitation spectra of the dyes do not overlap. However, this doesn t eliminate crosstalk for all experiments because some studies require fluorophores with overlapping emission and excitation spectra, such as combinations of GFP and its variants. To address this issue, emission fingerprinting, a detection technology incorporated into the LSM 510 Meta, can separate the spectra even if the overlap is extreme. The system allows the user to completely separate fluorescence emissions even if much of the emission profiles overlap, such as green and yellow fluorescent protein or GFP and Sytox Green. Emission fingerprinting requires the acquisition of the spectral composition of the fluorophores emission signatures in the sample and mathematical separation into images representing the distribution of the individual fluorophores (Figure 3). An algorithm allows the user to au-

Figure 3. For emission fingerprinting of GFP and yellow fluorescent protein in cultured cells, the user acquires the spectral emission signature in a series of spectrally resolved images (lambda stack) followed by linear unmixing on the basis of reference spectra for the proteins. The result is a pair of images representing the GFP and yellow fluorescent protein distribution in the sample, respectively. Sample courtesy of Frank D. Böhmer, Friedrich Schiller University. tomatically extract the spectral components. A highly parallel acquisition scheme makes emission fingerprinting ideal for live-cell imaging, particularly in the online mode where the separation occurs instantaneously during data acquisition. We are anxious to move into multicolors, said William C. Hyun, director of the Laboratory of Cell Analysis at the University of California, San Francisco. The ability to tune emissions and pick out the specific pattern of these fluorescent proteins allows us to go in and tease apart multiple probe sets for multiple GFPs. Being able to clear out the complicated spectral overlaps is a tremendous benefit. Key to success Accurate three-dimensional detection with a multiple pinhole system and unambiguous separation of spectrally overlapping dyes are the first prerequisites for a successful collocalization experiment. Such studies also require software functions for analysis of the resulting image. The latest version of the LSM 5 software (Rel. 3.2) introduces a collocalization analysis package (Figure 4). Key is the interactive link of the image display with a two-dimensional scatter plot representing the distribution of individual voxels of the image according to the signal intensities of the image channels. Either in the image display or in the scatter plot, regions can be selected interactively for analysis. A comprehensive set of quantitative data, including various collocalization coefficients and correlation parameters, can be directly extracted from the selected regions. With this, the user can adjust collocalization thresholds according to background intensities within the images or can perform, visualize and quantitatively assay for collocalization in the image set and color-overlay image voxels that are positively tested for collocalization. The optical resolution of light microscopes, including confocal microscopes, limits the detection of protein proximities to about 0.2 µm in conventional collocalization experiments. However, studying the physical interactions of protein partners requires higher resolution. FRET can resolve the proximity of proteins beyond the optical limit of light microscopes (in Figure 4. The software allows the user to perform quantitative collocalization analysis.

Figure 5. Emission fingerprinting reveals complete bleaching of yellow fluorescent protein and concomitant dequenching of cyan fluorescent protein, indicating fluorescence resonance energy transfer in the bleached areas (marked by dashes). the range of 1 to 10 nm). FRET imaging measures the nonradiative transfer of photon energy from an excited fluorophore (the donor) to another fluorophore (the acceptor). This interaction results in quenching of donor fluorescence and simultaneous sensitized photon emission by the acceptor molecule. Its efficiency depends on various parameters, including a sufficient overlap of donor emission and acceptor excitation spectra (as in cyan and yellow fluorescent proteins, today the most widely used FRET pair). The amount of energy transferred depends on the distance between the donor and acceptor. Therefore, the technique can be used as a molecular ruler and as an indicator of physical interactions between fluorescently labeled molecules. The use of pairs of fluorescent proteins, such as cyan fluorescent protein and yellow fluorescent protein as donor and acceptor molecules, respectively, has greatly facilitated in vivo FRET studies because they allow labeling of the molecules of interest with excellent specificity while retaining the integrity of the cell and its physiological functions. Several methods have been developed for imaging FRET in cells. One approach involves either bleaching the acceptor molecule and subsequent monitoring of concomitant dequenching of donor fluorescence or examining relative temporal changes of donor emission and acceptor/fret signals under donor excitation in dynamic situations (Figure 5). An al- Figure 6. By combining a confocal laser scanning microscope and a fluorescence correlation spectrometer, structures can be made visible and, at the same time, molecular interactions can be investigated.

ternative approach uses various excitationemission configurations (such as donor excitation-donor emission, acceptor excitation-acceptor emission, donor excitation-acceptor emission) and subsequent evaluation of sensitized acceptor emission via mathematical correction. The LSM 510 s abilities, such as multitracking, pixel-precise bleaching and online ratiometric analysis, allow the user to perform the described types of FRET experiments with high three-dimensional resolution. Until now, however, acceptor and donor with overlapping excitation and emission spectra required that the user select narrow detection bands to differentiate between emissions. Even then, quantitative approaches had to include complex mathematical corrections to account for inevitable crosstalk between channels and for local concentration differences. Emission fingerprinting overcomes several of these drawbacks. Parallel acquisition of the emissions from donor and acceptor provide the high photon efficiency and the image acquisition speed required in live-cell FRET microscopy. Sorting donor and acceptor emissions into separate output channels can produce significantly bigger signal changes in dynamic FRET situations. Finally, this method eliminates the need to correct for emission crosstalk in quantitative studies. While collocalization and FRET experiments still measure the distance between the protein partners of interest as an indicator of their possible interaction, fluorescence correlation spectroscopy directly measures the associated changes of diffusion times. We have combined our system with this technique in one instrument dedicated to fluorescence correlation spectroscopy analysis in living cells. Single-molecule sensitivity First, the researcher acquires a 3-D image stack of the cell. Then several fluorescence correlation spectroscopy analysis spots can be placed anywhere in or outside the cell at X, Y and Z positions. Each spot represents a measurement volume of less than 10 15 l. When starting the measurement, the system excites the spot and measures the fluorescently la- beled biomolecules passing through the defined volume as a photon shower of a defined time (Figure 6). From this, the system can calculate the characteristic diffusion times of the proteins of interest. If the instrument detects a prolonged diffusion time, the molecule of interest is directly interacting with another. A software correlator analyzes the photons registered by the detector for time interrelations. Thereby, the instrument can distinguish between populations of biomolecules with different diffusion times; e.g., populations of single molecules and a population of molecules associated in a complex. High-sensitivity avalanche photodiodes allow it to detect single molecules, providing a tool for direct measurement of dynamic molecular interactions within living cells. G Meet the authors Richard Ankerhold is head of the Training, Application and Support Center, and Bernhard Zimmermann is product manager for confocal laser scanning and advanced imaging microscopy at Carl Zeiss GmbH in Jena, Germany.