SUBFLOOR AND INSTALLATION PREPARATION INSTRUCTIONS

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

ATTENTION! READ BEFORE INSTALLING!

ENGINEERED LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

ENGINEERED WATERPROOF FLOORING GENERAL INSTALLATION INSTRUCTIONS FOR VÄLINGE 2G LOCKING FLOORING

WATER TUFF VINYL FLOORING ATTENTION! READ BEFORE INSTALLING! Angle-Tap Installation Instructions

INSTALLATION GUIDELINES PREFINISHED SOLID & ENGINEERED WOOD

ANTIQUED SOLID / SOLID HARDWOOD

LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR LOCKING FLOORING

9.5, 10, 10.5 & 12mm. Product Use & Installation Options. Engineered hardwood flooring INSTALLATION INSTRUCTIONS

Section III Installation Guidelines & Methods Page Chapter 7 Parquet Installation 30 Chapter 8 Engineered Wood Flooring Installation 34 Chapter 9

INSTALLATION INSTRUCTIONS

The. GARRISON Collection. Garrison Glue Down Vinyl Installation Instructions -

CLICK TOGETHER ENGINEERED LONGSTRIP HARDWOOD FLOORING CLICK TOGETHER CORK FLOORING CLICK TOGETHER BAMBOO FLOORING

INSTALLATION INSTRUCTIONS

HAND-SCRAPED FLOORING INSTALLATION INSTRUCTIONS

COMPOSITE (WPC) ENGINEERED VINYL FLOORING INSTALLATION

Installation Guide LVP Glue Down

ECOfusion Flooring Installation Guide 1/2 & 9/16 Prefinished Solid Strandwoven Bamboo Flooring

MILLTOWN. Product Use & Installation Options. 12mm engineered hardwood flooring INSTALLATION INSTRUCTIONS

BLUE FOREST Flooring Installation Instructions

UNDERLAYMENT INSTALLATION INSTRUCTIONS

1. Division 09 Section "Rough Carpentry."

ENGINEERED. 12mm engineered hardwood flooring INSTALLATION INSTRUCTIONS

SECTION PREFINISHED ENGINEERED WIDE-PLANK FSC OAK FLOORING

safari installation instructions

GUIDE SPECIFICATION

SECTION PREFINISHED FSC MAPLE FLOORING. This is a template: edit this specification carefully to suit specific project requirements.

Luxury Vinyl Plank Installation Manual 2017

PRE-INSTALLATION AND JOBSITE CONDITIONS

Floors. Allwood Floors 5/8" & 9/16" Floating Floors For Staple-Down or Glue-Down Installations. Installer/Owner Responsibility

INSTALLATION GUIDELINES Signature Naturals PureForm Solid Strip Bamboo Flooring

GUIDE SPECIFICATION

SECTION WOOD GYMNASIUM FLOORING

OWNER/INSTALLER RESPONSIBILITY

Commercial Resilient Sheet Flooring

Subfloor heating and cooling instructions for Hakwood flooring products Duoplank 20mm (¾ ) and Duoplank 15mm (⅝ )

RADIANT PANEL SYSTEM PLANNING & INSTALLATION. Roth Radiant Heating Systems

HARO SPORTS FLOOR C.S.I. GUIDE SPECIFICATION Helsinki-Gymnasium Floor System 10/2010 SECTION WOOD ATHLETIC FLOORING

General Commercial Installation Guide LAMINATE

INSTALLATION BASICS FOR TUFTED BROADLOOM BACKING

CFI Training Makes the Difference! FLOORING INSTALLERS

ATTENTION! READ BEFORE INSTALLING!

Amtico QuickStix LVF Installation

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

HYBRID. Pre-Laying Checks

The following instructions should be reviewed prior to installation. Shaw Industries will not be responsible for improper installation.

INSTALLATION BASICS FOR TUFTED BROADLOOM BACKING

RESILIENT FLOORING: Hot and Heavy - Secoya

Installation Guidelines for EcoDomo Echelon Collection RECYCLED LEATHER TILES AND SHEETS GLUE-DOWN METHOD WITH WATER BASED CONTACT CEMENT

Glue. Wood Flooring. to a. Concrete Slab FINE HOMEBUILDING

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

NXT SUBSTRATE PREPARATION AND PRIMER GUIDE TDS 230N

CHAMPAIGN CENTRAL HIGH SCHOOL COMBES GYM FLOOR REPAIR. A. Submittals: Product Data, Specification Sheets, Samples and Manufacturer Warranty.

IVC US Commercial Installation Guide - LVT. Leading the Way

PROJECT LOCATION. SECTION RECYCLED WOOD FLOORING Rev. 11/13/2012

Installation Products

Updated 1/25/13. Supercedes all previous versions. Check website for updates. ASE PREPARATIO

Infinity Modular/Infinity Modular RE Carpet Tile Installation Guidelines

Installation Instructions for CushionBac Renew Tiles

FLOORING INSTALLATION SYSTEMS. Product Catalog

Specification Data -- RESILIENT TILE FLOORING

GLUE-DOWN INSTALLATION VIRTUO 30 / 55

SECTION RESILIENT SHEET FLOORING

RESILIENT FLOORING: Select Step Wood

CONTRACT PAGE 1 OF 5

WOOD FLOORING WOOD FLOORING

INSTALLATION GUIDELINES The following instructions shall be reviewed prior to installation. Shaw will not be responsible for improper installation.

Installation Instructions Luxury & Premium Vinyl Plank. San Simeon, Polaris, Courtier

Installation and Maintenance

KOSTER AMERICAN CORPORATION

SECTION LATEX-MODIFIED MEDIUM BED MORTAR

RAUPANEL DRY SYSTEM HIGH PERFORMANCE PANEL SYSTEM

Tidewater Collection

THE GARRISON COLLECTION

INSTRUCTIONS FOR EDITING AND COORDINATION SECTION WOOD FLOORING - ATHLETIC

FlexLok Adhesive Tabs for Carpet Tile

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

CASABELLA HARDWOOD FLOOR MAINTENANCE & INSTALLATION INSTRUCTIONS FOR:

TechLevel 125 Deep Pour Self-Leveling Underlayment

INSTALLING MrPEX TUBING

Product Width Thickness Installation direction Seam treatment. Taraflex Sport M Comfort Approximately mm + 5mm Same Heat Welded

COMPLETE INSTALLATION INSTRUCTIONS AU NATUREL COLLECTION

SPECTRA CLICK RESILIENT VINYL PLANK INSTALLATION GUIDELINES

Access Luxury Vinyl Flooring Installation Guidelines

IVC US Residential Installation Guide - Sheet Vinyl. Leading the Way

Concrete 1,8 2,0 Anidrite 0,3 0,5

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Engineered Hardwood Flooring Installation Instructions Glue: All profiles Nail: 3/8", 1/2", 3/4" Staple: 3/8", 1/2" Float: 1/2"

Engineered Installation Guide

Tufted and Woven Goods Direct Glue-Down

OSB. Design and Application Guide

ADVANTECH SHEATHING SUBMITTAL FORM

Resilient and Wood Floor Covering Flatness Requires High Performance, Cementitious Self-Leveling Underlayment

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Carpet Tile & Plank Direct Glue Down

INSTALLING VINYL FLOORING

Transcription:

Subfloor Guide for Hardwood Ask any quality wood flooring contractor, and he'll tell you that your hardwood installation is only as good as the subfloor you're installing over. Before the wood is delivered to the job site take the time to carefully inspect the subfloor and fix any problems that might affect your installation. The industry standard is that all subfloors should be clean, dry and flat before wood flooring goes down. Following these simple rules and understanding what you are dealing with will help lead to a successful installation. Here are the common subfloors you'll deal with on the job and checklists to help you make sure the subfloors will be ready for your wood flooring installation. The following are general guidelines from NWFA's Installation Guidelines. For specific information, always follow the manufacturer's recommendations for the product you're installing. Plywood and OSB Over Joists Plywood and OSB subfloors over joists are most common in newer homes and new construction, typically in homes with basements or crawlspaces. 1) Suitable Wood Flooring: Any. 2) Thickness: Plywood (CDX grade & exposure 1) and OSB panels are acceptable subfloors for hardwood flooring as long as they are the proper thickness. Generally, the minimum thickness for plywood is 5/8 inch; for OSB it's 23/32 inch. However, as joist spacing increases, the subfloors need to be thicker. For joist spacing of more than 16 inches up to 19.2 inches on center, the minimum thickness for both plywood and OSB is 3/4 inch. For joists spaced more than 19.2 inches on center, the minimum thickness for plywood is 7/8 inch and for OSB, 1 inch. Keep in mind that for mechanically fastened floors, OSB doesn't hold fasteners as well as plywood, so you may need to use a thicker material to get the same holding power. 3) Check Before Installation: Once you determine the subfloor is the proper thickness, check that the subfloor has installed properly, with no issues that could affect your installation. Subfloor panels and fasteners should be properly placed according the panel manufacturer's specifications. If there are protruding fasteners, squeaks or loose panels, re-fasten the subfloor to

the joists. The subfloor should also be clean and free of contaminants such as paint, sealer or drywall compound. Inspect the subfloor from below and note the direction of the joists. With the above specs, the flooring should be installed perpendicular to the floor joists. The flooring can be laid parallel to floor joists, but you may need to add a 1/2-inch layer of plywood diagonally or perpendicularly to the joists, or install a brace between the joists. 4) Flatness: Ensure the subfloor is flat to the recommended tolerances for the flooring you are installing. For installations using mechanical fasteners 1-1/2 inches and longer, subfloors should be within 1/4 inch in 10 feet or 3/16 inch in 6 feet. For glue down installations and those using mechanical fasteners less than 1-1/2 inches, the subfloor should be within 3/16 inch in 10 feet or 1/8 in 6 feet. The subfloor can be flattened by sanding down the high areas or by installing shims such as roofing shingles or various thicknesses of plywood. 5) Moisture: Another critical part of the subfloor inspection process is checking the moisture content (MC) of the subfloor and joists. A moisture meter should be your best friend on the job. Whether you are using a pin or pinless model, make sure it is calibrated correctly for the species you are testing. Take several readings, a minimum of 20 per 1,000 square feet and document them. Many installers write the MC reading and date right on the subfloor, log them in the job-site notes and take photos for further documentation. If problems arise later, you may need to submit proof that you followed the correct procedures. For solid strip flooring, there should be no more than 4 percentage points' difference in MC between the subfloor and the flooring; solid plank flooring wider than 3 inches requires no more than 2 percentage points' difference. Although moisture may be in check at the time of installation, it could slowly seep in through the wood subfloor and eventually into the wood flooring above. To help prevent this, an approved moisture-vapor retarder should be placed between the subfloor and the wood flooring. Approved vapor retarders include 15-pound asphalt felt paper, asphalt-laminated paper such as Aquabar B. A vapor retarder material with a perm rating of 0.7 or less, such as a 6 mil poly, can trap moisture in the wood subfloor and should not be used. Some manufacturers have their own recommendations for vapor barriers depending on which product you are installing, so always check with the flooring manufacturer first.

Particleboard Particleboard is frequently discovered as a subfloor layer over plywood when carpeting or vinyl are ripped out. 1) Suitable Wood Flooring: Floating floors, however some manufacturers do allow for engineered flooring to be stapled over particleboard. Particleboard has little no holding power for fasteners. Other wood floors may be installed if the particleboard is ripped out, but if the original subfloor is not thick enough, at least a 1/2-inch layer of plywood or 3/4-inch OSB must be added once the particleboard is removed. The other option is to install a layer of plywood or OSB over the top of the particleboard although that may create unacceptable height differences with the adjoining rooms; always check. Concrete Slabs 1) Suitable Wood Flooring: There are several options for installing wood flooring over concrete. Always use the product and installation method recommended by the manufacturer. Directly Over Concrete: Floating floors, engineered floors, some solid strip and plank, and some parquet. Solid wood flooring is never recommended below grade, but some solid wood flooring manufacturers now recommend their products for glue-down over slabs. A vapor retarder is recommended any time you install a solid 3/4 inch wood flooring over concrete. Over Concrete with a Wood Subfloor: Any. Over Concrete with Sleepers: Solid strip or plank can be laid directly over a sleeper system, but engineered wood flooring less than 3/4 inch thick or solid plank wider than 4 inches requires a wood subfloor over the sleepers. For obvious reasons, parquet cannot be installed over sleepers unless an additional layer of plywood or OSB is added.

2) Weight: There are different types and weights of concrete slabs, and not all are acceptable for glue-down installation of hardwood flooring. The slab must be a minimum of 3,000 psi; lightweight concrete is not acceptable unless you are installing a floating floor or a wood subfloor over the slab. A quick test is to drag a nail or other sharp object across the slab if it leaves an impression, there's a good chance it's lightweight concrete. 3) Surface: As with all subfloors, inspect the surface of the slab for areas that can affect the flooring installation. The slab should be clean and free of contaminants such as sealers, waxes, drywall or paint. Slick slabs can prevent adhesive transfer, so areas may need to be abraded according to the adhesive manufacturer's recommendations. Also check for hollow spots, cracks and loose areas. You may need to grind down the slab or repair these problem areas. 4) Flatness: The slab should also be flat to the wood flooring manufacturer's specifications, usually 1/8 inch in a 10-foot radius. Mechanical methods for flattening the slab include grinding, bead-blasting or abrading. There are many self-leveling concrete compound products on the market, as well as patching compounds. The condition of the slab and products you are working with determine which methods to use. Always check with the flooring adhesive manufacturer to determine what is the best method to flatten the slab with the products you're using. 5) Moisture: As with plywood and OSB subfloors, moisture testing is one of the most important parts of your installation. Concrete is a porous material and can retain moisture and emit moisture vapor, which could end up in the wood floor above unless the proper precautions are taken. In new construction, the slab should be given at least 60 days to cure. No matter if it's new or old, or on or above grade, the slab should be thoroughly tested for moisture before any installation begins. Common concrete moisture testing methods include: Calcium-chloride test (ASTM F1869): measures the amount of moisture emitted from a 1,000-square-foot sample of slab surface in 60 to 72 hours. Concrete moisture meter: uses electrical impedance and electrical resistance to measure moisture in the slab.

Relative humidity (RH) tests: measures RH by using either the Insitu Method (ASTM F- 2170) or the RH Hood Method (ASTM F2420). 6) Additional subfloors: Depending on the product you're installing, you may need to install a wood subfloor over the slab. There are several methods, including: Floating subfloor: There are two common methods for this. The first is to lay two layers of 3 8 -inch plywood over the slab without fastening or gluing them to the slab. One layer is laid, and the second layer is stapled or glued perpendicularly or diagonally over the top. The second method is to loose-lay one layer of 3/4 -inch plywood cut into 16-inch planks perpendicularly or diagonally to the direction of the flooring. The panels should be staggered every 2 feet and spaced 1/8 inch between ends. Glue-down subfloor: 5/8 -inch plywood panels are glued in a staggered joint pattern directly to the slab. Nail-down subfloor: 5/8 -inch or thicker plywood panels are fastened every 12 inches on center and every 6 inches along the border. Sleeper system Common over radiant heat, this system has 2-by-4s spaced 12 inches apart. Solid strip or plank can be laid directly over a sleeper system, but engineered wood flooring less than 3/4 inch thick or solid plank wider than 4 inches requires a wood subfloor over the sleepers. Whichever method you use for an additional subfloor, allow 3/4 -inch expansion space at the walls and vertical obstructions. Older Subfloors When you're walking into a remodeling situation, you never know what you will encounter on the job site. Removing existing floor covering can reveal many unpleasant surprises such as rotten boards, water damage, severe dips or humps, old adhesive or even mold. That is why

it's important to do a thorough inspection from below from the basement or crawlspace. Common older subfloors include: Solid Wood Subfloor. This type of subfloor is common on older homes. As with plywood subfloors, if there is movement or squeaks, refasten the subfloor to the joists and set protruding fasteners into the subfloor. The boards should be no wider than 6 inches and installed on a 45-degree angle. If the subfloor is not acceptable, it can often be overlaid with 1/2 -inch plywood. Some wood flooring may not hold sufficiently if installed directly over solid wood subfloors. Engineered or solid strip flooring less than 1/2 -inch thick and parquet flooring may need an additional 3/8 -inch layer of plywood installed over these types of subfloors. Always check with the flooring manufacturer when in doubt. Existing Floor Covering. Vinyl, linoleum or an old wood floor, your best bet may be to install the new floor directly over the old one. The existing flooring must be fully adhered. Do not remove an old floor covering if you think it may contain asbestos. Flooring and cutback adhesives manufactured into the late 1970 s contained asbestos. If you can't determine the age of the floor or are in doubt, have a sample tested before you rip out the floor. Any floor containing asbestos requires a professional abatement crew to remove the old floor. Even if you know older floor covering doesn't contain dangerous contaminants, you may still want to leave it in place. For nail down hardwood floors, you can leave vinyl floor covering in place, and it can even act as a vapor retarder. For glue-down applications, you need to make sure and waxes or polish has been removed from the floor covering. Always check with the adhesive manufacturer for its recommendation. If you leave existing floor covering in place, always check the height differences with floor coverings in adjoining rooms. No matter which subfloor you are dealing with, you need to let everyone involved know what is needed for a successful wood flooring installation. Your customer may not see what is beneath the beautiful wood floor, but what you do below determines how the floor will look above. By following all the steps to prepare your subfloor, you create a solid foundation for your wood flooring.

Tim is a certified instructor for Armstrong, Avaire, Konecto and Starloc products an has been a member of the Armstrong Installation Training Team since 1984. Tim has highly developed installation skills and qualifications that have been combined over his 32 years in the floor covering industry. Tim is privy to all the latest innovations and techniques used in the installation of their products. We are sure you will find your skills improved after attending one of his installation courses. To view a complete list and register for one of Tim s installation trainings, click here on the QR or visit: http://www.jjhaines.com/forcustomers/installation-training/ CONTACT TIM tmcadoo@jjhaines.com 410-903-2930