Dekati. ELPI Electrical Low Pressure Impactor. Real-time particle size distribution Wide particle size range Wide range of applications

Similar documents
MMEA D Results of the feasibility studies for combustion and diesel exhaust gas measurements

Flue Gas Particle Characterization at Different Parts of the Power Plant

Compact flue gas analyser: testo 300 M-I

Combustion Laboratory Unit C492

Fine particle measuring system

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

New Measurement Engineering For Monitoring Emissions In Industry

Using the PPM2 Portable Trace Moisture Transmitter

testo 350 M testo 350 XL

Product data sheet Palas Condensation particle counter UF-CPC 100

testo 330 Flue gas analysis with increased convenience and safety

The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Gas concentrations in the air

FIDAS FINE DUST MONITORING SYSTEMS. Fidas the world s only certified optical fine dust measurement system with single particle analysis for PM 2.

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

Fpollutant-free zero air for analytical

THE ULTIMATE Environmental fine dust measurement devices

GreenLine 8000 GAS ANALYSIS. Portable Industrial Combustion & Emission Analyser O 2 CO 2 CO CO% SO 2 CH X Y NO 2 HS 2

GAS 3050P NDIR FLUE GAS

GRIMM Aerosol Technik Grimm Instrumentation The future of particle measurement Ing. Wolfgang Brunnhuber Environmental Division Manager

Pioneering ALD experience since The ALD Powerhouse PRODUCT CATALOGUE FOR SUNALE P-SERIES ALD SYSTEMS

TECHNICAL DATA SHEET

The most energy efficient compressed air filters in the world.

Validation Guide USTR 2114 (2) Validation Guide for Pall Emflon PFR Filter Cartridges

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

AIRBORNE PARTICULATE MATTER WITHIN 100 RANDOMLY SELECTED OFFICE BUILDINGS IN THE UNITED STATES (BASE)

PORTABLE COATING THICKNESS GAUGE

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

EUROλYZER STx. Flue Gas Analyzer. BlueLine

Online Gas Analyzer / Monitor

Multi-function VAC measuring instrument

Humidity/temperature measuring instrument

COMBIMASS. Technical Data COMBIMASS GA-m / GA-e Version

Instruction Manual Dräger MSI EM200-s

HiSeqTM 2000 Sequencing System

CyFlow Cube series Appealing from every angle

Flue gas analyzer. We measure it. testo 310 Flue gas analysis the easy way. Robust design for daily use. Battery lifetime up to 10 hours

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Counting the Way to Cleaner Air

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

Sampling method for particle measurements of vehicle exhaust

General Plan OXYGEN SERVICE CONTAINER 2005 Version 1.02

Low Temperature Testers

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

A UT OCL A VE VE OCLA UT A _AutoClave_D1102EN_1703.indd /03/01 13:45

PORTABLE HARDNESS TESTING

GRAVOTECH GROUP. Complete range of Integrable Fiber Laser Marking Solutions LASER SOLUTION F-SERIES.

Melting Point M-565 Technical data sheet

Filtration Products. Fluid purifier systems and oil service equipment

Power Resistor for Mounting onto a Heatsink Thick Film Technology

RHEOLOGICAL PROPERTIES ROSAND RH7 & RH10 RHEOLOGICAL INSTRUMENTS BACKED WITH RHEOLOGICAL EXPERIENCE

Size reduction principle Material feed size* wet impact, friction < 10 mm Final fineness* < 1 µm, for colloidal grinding < 0.1 µm Batch size / feed qu

Nilan VPL Active heat recovery and cooling (air/air)

EBI 10 High Precision Wireless Data Loggers

MEASUREMENT OF BRAKE WEAR EMISSIONS BY THE ENGINE EXHAUST PARTICLE SIZER (EEPS) SPECTROMETER AND OPTICAL PARTICLE SIZER (OPS)

Power Electronics Packaging Revolution Module without bond wires, solder and thermal paste

Thermally operated mobile air-conditioning system

Online data sheet MCS100E HW-C CEMS SOLUTIONS

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

Electra Elite IPK II In-Mail Utility Guide

Assessment of the emission behavior of nanomaterial-containing waste in thermal treatment plants

Data Logging Solutions from Lascar Electronics

Remote AMD Operator Manual

Product Bulletin. Panduit Permanent Identification System. Applications. Technical Information

Hydrotherm. C. Gerhardt - Analytical Systems. Hydrolysis System

Designed to meet BS7927, TUV, ISO, Gastec QA Criteria, GOST, Qualigaz, and UNI 10389

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

DEK Gemini Platform Technical Specification

3SP_CO_1000 Package

TOUCH FOIL INSTALLATION GUIDE

Effect of Flue Gas Recirculation on the Formation of Fine Particulate Matter in a Domestic Pellet-Fired Boiler

WBEA Standard Operating Procedure

Provide Accurate Results. Operational Manual. AccuReader. AccuMate. PC Software. Metertech Inc. Version 1.02

TOTEM. Cogeneration (CHP) Range. TECHNICAL SUBMITTAL TR r2. Highest total efficiency with modulating output and lowest NO X emissions available

TEMPERATURE CHAMBER (+5 C +180 C) TK-50 CK TK-105 CK TK-190 CK TK-340 CK TK-500 CK TK-1000 CK

Steven L. Alderman, Michael S. Parsons, and Charles A. Waggoner. Institute for Clean Energy Technology, Mississippi State University

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Laser Sintering Solutions

2008 Beltwide Cotton Conferences, Nashville, Tennessee, January 8-11, 2008

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

GRAVOTECH GROUP FIBRE LASER. Complete range of integrable laser marking systems LASER SOLUTION F-SERIES.

Instrument specifications Technology Software Host interfaces Printer interfaces Data Station Physical dimensions Weight Certifications

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

The Leader in Performance Indoor Air Quality Measurements

SpeedExtractor E-916 / E-914 Technical data sheet

GHS VSD + SERIES. Oil-sealed rotary screw vacuum pumps With Variable Speed Drive (VSD + ) technology

GreenLine 6000 GreenLine 8000

If you think vertical sterilizers are all the same, have a look at what we have done: the new FVA /A1 FEDEGARI AUTOCLAVI SPA

Enterprise Call Recorder

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

Panduit Permanent Identification System

Instruction Manual. for. gskin U-Value Kit

Digital Self Contained Weighing Module

Smarter Choices, Better Air.

July P Wide Format Stacker User Guide

RMF Intercell. NBS Specification 2013 K41

INDEX. 1 Introduction. 2 Software installation. 3 Open the program. 4 General parameters. 5 Tuning

Formation of Fine Particulate Matter in a Domestic Pellet-Fired Boiler. José Madeira

Transcription:

Dekati ELPI Electrical Low Pressure Impactor Real-time particle size distribution Wide particle size range Wide range of applications Excellence in Particle Measurements

Dekati ELPI Electrical Low Pressure Impactor ELPI (Electrical Low Pressure Impactor) enables measurement of real-time particle size distribution and concentration in the size range of 7nm - 10μm. The ELPI combines well-known impactor technology with particle charging and electrical detection. The result is a robust instrument which measures particle size distribution in a wide size and concentration range, accurately and in real-time. The use of impactor technology also enables post-measurement chemical analysis of size classified particles. The ELPI can also be used for real-time particle charge distribution and gravimetric impactor measurements. During measurement, the ELPI instrument is completely controlled and data is saved with easy-to-use ELPIVI software. In addition to controlling the instrument operations, Sample Corona charger Flush pump and filter HV and power source External PC or laptop the ELPIVI enables the monitoring of total concentration and particle size distribution of the sample in real-time. The software enables operating of several ELPI units with one piece of software and sending the data or using the instrument via a network connection. Operating Principle The ELPI operating principle can be divided into three major parts: particle charging in a unipolar corona charger, size classification in a cascade impactor and electrical detection with sensitive electrometers. The particles are first charged into a known charge level in the corona charger. After charging, the particles enter a cascade low pressure impactor with electrically insulated collection stages. The particles are collected in the different impactor stages according to their aerodynamic diameter, and the electric charge carried by particles into each impactor stage is measured in real time by sensitive multi-channel electrometers. This measured current signal is directly proportional to particle number concentration and size. The components are housed in a single compact unit. Standard RS232 port is used for communication with a laptop or PC using ELPIVI software. Impactor Vacuum pump Electrometers and A/D Pressure sensor Internal PC (External in/out) Controls and LCD display The particle collection into each impactor stage is dependent on the aerodynamic size of the particles. Measured current signals are converted to (aerodynamic) size distribution using particle size dependent relations describing the properties of the charger and the impactor stages. The result is particle number concentration and size distribution in real-time. By switching the charger unit off, the ELPI can be used for particle charge distribution measurements.

Excellence in Particle Measurements Applications The ELPI can be used in various different types of applications where the requirements for the instrument include wide particle size range and fast response time. Because of its rapid response, the ELPI is an ideal instrument for the analysis of unstable concentrations and size distributions, or the evolution of size distributions. Typical applications for the ELPI include: Automotive exhaust measurements Blow-by gas measurements Combustion studies Outdoor and indoor air quality measurements Pharmaceutical inhaler studies Particle charge distribution measurements Filter grade efficiency studies Benefits Real-time particle size distribution and total concentration Wide particle size range; 7nm - 10μm * Real-time charge distribution measurements Gravimetric impactor measurements Possibility for chemical characterization of size classified samples Wide operational concentration range Two sample flow rate versions; 10 or 30 lpm Simple construction Robust structure Wide range of applications *with the filter stage accessory Outdoor Air ELPI TM The Outdoor Air ELPI is a modified version of the standard ELPI instrument. Like the standard version, the Outdoor Air ELPI measures airborne particle size distribution and concentration in real-time. It operates in the size range of 7 nm 10 μm with the filter stage accessory, and can be applied to various different types of measurements where the requirements for the instrument include a wide particle size range and fast response time. The Outdoor Air version is specially designed for ambient air measurements, although it can be used in other applications as well. The operating principle of the Outdoor Air ELPI is the same as that of the ELPI s. Some features have been added to the Outdoor Air version to make it more suitable for ambient air monitoring: Higher sample flow rate (30 lpm) to increase sensitivity Integrated humidity and temperature sensor for monitoring the sample Option for stand-alone operation USB connection for stored data output

Accessories Filter stage The ELPI filter stage extends the standard ELPI measurement range from 30 nm 10 μm to 7 nm 10 μm. The filter stage is a back-up filter installed under the impactor stages; stage 12 is removed from the impactor assembly to enable an easy upgrade and use of the existing electrometers. The upgrade is fully reversible; the ELPI can be used with or without the filter stage after the upgrade. Sintered Collection Plates Sintered collection plates are designed to prevent common problems in impactor measurements: impactor overloading and particle bounce. Instead of collecting the particles on smooth aluminium foil, the collection area is vacuum oil embedded porous metal. When the particles are collected on the plates, the oils seep up due to capillary forces and thus the impaction always occurs to a liquid surface effectively eliminating bouncing. External Heating Assembly The ELPI External Heating Assembly Set allows the ELPI charger and impactor to be heated up to 200 C. The use of the External Assembly Set requires some modifications to the standard ELPI unit since the impactor and charger have to be pulled out of the ELPI box. For example, the external heating assembly can be used in combustion aerosol and ambient air measurements to prevent the effect of VOCs and humidity on the aerosol size distribution. Other Accessories and Consumables Include: Aluminium and polycarbonate Impactor collection foils, 25mm Collection substrate spray (DS-515) with a stencil (DS-125) Vacuum pumps for 10 and 30lpm ELPIs Spare Impactors (10 or 30lpm) Dekati Fine Particle Sampler (FPS-4000) for diluting and conditioning sample from combustion flue gas and automotive exhaust Dekati Dryer (DD-600) for removing water from ambient air aerosol PCI board for analogue ELPI data output

Software ELPIVI software features a graphic user interface to control the ELPI or Outdoor Air ELPI instrument, and save the measured data. A real-time display of particle concentration, intensity and size distribution is displayed during data acquisition. Data can be displayed either on a number, volume, area or mass basis. Measured data is saved in an ASCII text file which can be processed later with e.g. ELPIxls spreadsheet. The software is equipped with user informative displays and warnings for all critical instrument operations. General view: Particle size distribution and time variation in concentration and intensity in the same view Own window for each data format Detailed measurement setup data Own window for each data format Unit info: measurement parameters

Dekati ELPI Electrical Low Pressure Impactor Specifications Particle size range 0.007 10 μm with filter stage 0.030 10 μm standard Number of size classes 12 Sample flow rate 10 or 30 l/min Impactor dimensions Ø 65 x 300 mm ELPI dimensions H 570 x W 400 x D 230 mm Collection plate diameter 25 mm Unit weight 35 kg Lowest stage pressure 100 mbar Pump requirements* 7 m 3 /h at 100 mbar (10 lpm) 21 m 3 /h at 100 mbar (30 lpm) Operating temperature 5 40 ºC Up to 200 ºC with the External Heating Assembly Operating humidity 0-90 % RH Non-condensing Time resolution 1 Hz Computer requirements Pentium III 500 MHz, 512 MB RAM, MS-Windows NT TM, 2000 TM, XP TM or Vista TM *Suitable pumps available at Dekati Ltd. Stage D50% Di Number min Number max Mass min Mass max [μm] [μm] [1/cm 3 ] [1/cm 3 ] [μg/m 3 ] [mg/m 3 ] 13 10 12 6,8 8,4 0,10 2,0E+04 31 8300 11 4,4 5,3 0,10 2,0E+04 10 2700 10 2,5 3,2 0,17 4,5E+04 3 810 9 1,6 2 0,33 8,8E+04 1,4 370 8 1 1,3 0,6 1,6E+05 0,70 180 7 0,65 0,81 1,1 2,9E+05 0,30 80,0 6 0,4 0,51 2 5,4E+05 0,10 40,0 5 0,26 0,33 3,7 9,8E+05 0,07 18,00 4 0,17 0,21 6 1,7E+06 0,03 8,00 3 0,108 0,14 12 3,1E+06 0,02 4,00 2 0,06 0,081 23 6,1E+06 0,006 1,70 1 0,03 0,042 50 1,4E+07 0,002 0,50 Filter stage 0,007 0,014 250 6,9E+07 0,0004 0,11 Labview is a trademark of National Instruments Inc. ELPI is a trademark of Dekati Ltd. Dekati is a registered trademark of Dekati Ltd. Related patent 6401553. Dekati Ltd. reserves the right to make changes to product(s) described herein without prior notice. Copyright Dekati Ltd. 2010. Values are for 10lpm ELPI - with 30lpm ELPI the sensitivity is improved by approximately 300%. Acknowledgements This instrument originated through work carried out at the Aerosol Research Group at Tampere University of Technology, Tampere, Finland. The ELPI low pressure impactor was designed in co-operation with the Finnish Meteorological Institute, Aerosol Research Group. For more information, please contact: sales@dekati.fi Dekati Ltd. Osuusmyllynkatu 13 FIN-33700 Tampere Finland Tel. int. +358 3 3578 100 Fax int. +358 3 3578 140 E-mail sales@dekati.fi www.dekati.fi Dekati Ltd. is specialized in the design and manufacture of innovative fine particle measuring and sampling devices. Since its founding in 1994, Dekati has become the technological market leader in producing fine particle measurement instrumentation for various applications and hundreds of customers. Pictorino Oy 1/2010