Disclaimer. Healthcare facilities are required to have written policies approved by their governing body concerning the services that they provide.

Similar documents
CMS, FDA and AAMI Requirements for Bicarbonate Systems Made Simple. Compiled January 2012 by AmeriWater Incorporated

Water and Dialysate Safety: Your Role in Maintaining Quality. Glenda Payne, MS, RN, CNN

Dialysis Water PREVIEW and Dialysate COPY Recommendations:

Hot Topics in Drug Product Process Validation: A Reviewer s Perspective

USP Chapter 823 USP 32 (old) vs. USP 35 (new)

AAMI Quality Systems White Paper: Comparison of 21 CFR Part 820 to ISO 13485:2016 1

DIALYSIS WATER TREATMENT DIALYSIS PROCESS WATER SOLUTIONS THE PREMIER PROVIDER OF WATER TREATMENT SOLUTIONS TO THE DIALYSIS INDUSTRY

photo: Ameriwater.com Dialysis Water Treatment Equipment Monitoring December 2017 Developed by the BCPRA Hemodialysis Committee

FDA Medical Device HFE Guidance

HaemoDialysis: New Technology. Peter G Kerr Monash Medical Centre and Monash University Clayton, Vic, Australia

International Water Standards

Revaclear. For best in class high flux performance. Smarter dialyzer technology

The new AK 96 machine

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 4: Implantable infusion pumps

GENERAL SURGERY DEVICES

Renal Dialysis Services

FDA > CDRH > CFR Title 21 Database Search

Validation Study on How to Avoid Microbial Contamination during Pharmaceutical Production

PHYSICO-CHEMICAL, BIOLOGICAL OR MICROBIOLOGICAL TESTS OF MEDICINAL PRODUCTS

Autoclave Installation and Operation Guidelines

One such problem is blood residual inside the channels of a robotic arm.

Guidelines for Process Validation of Pharmaceutical Dosage Forms

Harmonizing FDA Regulation and the Practice of Pharmacy: Challenges and Opportunities. Plus an update on PET Drug User Fees

Steam Sterilization Monitoring in the New CSA Standard (Z )

GMP and Quality Control: An Industry Perspective. Steven S. Zigler, Ph.D. PETNET Pharmaceuticals, Inc. Knoxville, Tennessee

CAUTION: U.S. Federal law restricts this device to sale by or on the order of a licensed physician.

PDA: A Global. Association. Matrix Approach to Media Fills. (c) 2012 Catalent Pharma Solutions. All rights reserved.

Early Development Best Practices for Stability- Regulatory Perspective

Donner Summit Public Utility District Wastewater Treatment Plant Toxicity Reduction Evaluation (TRE) Work Plan

Process Validation Lifecycle Approach: A Return to Science

Creating, Managing and Delivering Regulated Content in Pharma. Jim Nichols VP, US Operations & Life Sciences DitaExchange Inc.

The interface between Good Clinical Practice and Good Manufacturing Practice

Metrics in Microbiology Monitoring Practices

Aseptic Process Validation

Mar Cor Purification. Carbon Block Filtration System. Operation & Maintenance Manual

ISO INTERNATIONAL STANDARD

ELECTROTECHNIQUE IEC INTERNATIONALE INTERNATIONAL ELECTROTECHNICAL

Guide for Cleaning, Sterilization and Storage of Introducers for Caldera Medical Implants

Instructions for Use Reprocessed Balloon Inflation Devices

STERILIZATION VALIDATION IN THIS SECTION REPROCESSING VALIDATIONS FOR REUSABLE MEDICAL DEVICES. Radiation Sterilization Validation

EU and FDA GMP Regulations: Overview and Comparison

Mar Cor Purification MILLENIUM HX REVERSE OSMOSIS UNIT Operation and Maintenance Manual

Inspections, Compliance, Enforcement, and Criminal Investigations

Dual Port isolated USB Charger

REUSABLE MEDICAL DEVICE VALIDATION

RTV615. Technical Data Sheet

System Management Forum. Conformance Program Issue Tracking Process

Burton Hospitals NHS Foundation Trust. On: 22 January Review Date: December Corporate / Directorate. Department Responsible for Review:

ISO INTERNATIONAL STANDARD

Study Summary. Results: All tested media-filled vials were negative for growth of any microorganisms.

Trinity College Dublin QP Forum 2017 Tuesday 25 th April

Guidelines on procedures and data requirements for changes to approved biotherapeutic products. Proposed guidelines

CV-2566 CONTROLLED VOLATILITY RTV SILICONE ADHESIVE

Quality Manual. Index

ISRCTN: EudraCT Number: Sponsor Protocol Number: UCL 08/0350. Pharmacy Manual

Photographic Processing Facility Sector Control Policy

Water purification in the pharmaceutical industry

STORMWATER MANAGEMENT PROGRAM. Table of Contents

ISO INTERNATIONAL STANDARD. Rigid cellular plastics Spray-applied polyurethane foam for thermal insulation Part 2: Application

Point of intake methods

OOS: Back to Basics. Compliant, Effective, Efficient PATH

Dialysis water purification

Guidance for Industry - Computerized Systems Used in Clinical Trials

Regulatory Pathways. Devices vs. Drugs Are there roles for registries? John Laschinger, MD CDRH/ODE/DCD/SHDB

Work Instruction - Research Billing Risk

Cartridge Based Pyrogen Filtration System (1 Filter)

Mar Cor Purification 700 SERIES REVERSE OSMOSIS UNIT. Operation and Maintenance Manual

for IND and RDRC Regulated PET Compounding

01.48 Receiving and Processing Vendor Owned Surgical Instrumentation in the Sterile Processing Department

OECD and EPA GLP Differences

U.S. FDA TiTle 21 CFR PART 11 ComPliAnCe ASSeSSmenT of SAP SRm

Compounding Solutions. An advanced system for multi-ingredient solution compounding

Sample Bid Specification Revision 2 PVC Expanded-in-Place Pipeline Reconstruction

21 CFR Ch. I ( Edition) Personnel Design controls Identification Traceability.

Questions and Answers on allogenic stem cell-based products for veterinary use: specific questions on sterility

eircom Service Level Agreement for Interconnect Paths

SIMATIC IT. SIMATIC IT R&D SUITE V7.1 Compliance Response ERES. Introduction 1. The Requirements in Short 2

References Concept. Principle. EU Annex 11 US FDA , (g), (i), 11 Orlando Lopez 2/15/11. Old Annex 11.

ISO INTERNATIONAL STANDARD

Infor LN Minimum hardware requirements. Sizing Documentation

SA 450/60 Material Data Sheet

Computerised Systems. Alfred Hunt Inspector. Wholesale Distribution Information Day, 28 th September Date Insert on Master Slide.

Food and Drug Administration, HHS Pt Sec Scope Definitions Quality system.

Patient Handbook on Stem Cell Therapies

The Device Side of Combination Products

ZONING ADMINISTRATOR AGENDA

Summary of LAKE ONTARIO Policies. 1. Requiring SPC approval: LO SEW 3 LO FUEL 2

ISO INTERNATIONAL STANDARD

Requirements for Industry PIF. Regional Training on Product Information File (PIF) Product Information File (PIF)

Mircea Ciuca, MD Global Head Medical & Clinical Drug Safety

VIGILANZA E SORVEGLIANZA POST- COMMERCIALIZZAZIONE

Annex A2. Guidance on Process Validation Scheme for Aseptically Processed Products

Precision Automatic Vacuum Control (PAVC+)

Document Reuse: Theory and Practice

Data Reliability - Internet

GxP Auditing, Remediation, and Staff Augmentation

Automated Plate Replication

DELIVERING SOLUTIONS FOR PATIENTS

Transcription:

Disclaimer Healthcare facilities are required to have written policies approved by their governing body concerning the services that they provide. NxStage Medical, Inc. has prepared this document to assist you in your preparation of policies and procedures for use with the NxStage System One. The information presented herein is intended as a guide for reference purposes only, and all providers are encouraged to modify these draft policies and procedures based on their own unique needs. Warnings and precautions, as documented in the NxStage System One and/or PureFlow User Guides, have not been included in the attached Policies and Procedures. Operators of the equipment should refer to both Policies and Procedures and the User Guides. We encourage providers to include warnings and precautions into their approved Policies and Procedures in a manner consistent with facility protocol. Efforts have been made to ensure that these policies are based on current information. However, policies and procedures are the responsibility of the healthcare facility and therefore must be reviewed and edited carefully before incorporating into an individual facility s program.

Transitional Care Policies & Procedures Page 2 of 5 Policy Number: 4 Effective Date: Water and Dialysate Evaluation and Testing Guidelines for PureFlow SL in Transitional Care Reviewed/Revised Date Purpose: To provide guidelines for testing, evaluating, and monitoring the quality of and dialysate used by the hemodialysis patient using PureFlow SL with the NxStage System One (known to CMS as preconfigured system) for compliance with the CMS Conditions for Coverage. Policy: Water and dialysate testing and documentation will meet NxStage, CMS, and AAMI standards and guidelines. Documentation of testing, results, and interventions will be maintained at the dialysis center. TAG# Sample Frequency Test Performed V593/ V594 Source : Municipal Initially to verify source is within range for the use of PureFlow SL. Chemical analysis of the standard AAMI test panel contaminants to ensure product manufacturer s specifications are met. See PFSL User s Guide 4), Section 10: Specifications for Source Water Purity Limits. V594/ V276 Initially: Test first PAK used near the estimated end of PAK life. Annually: Test near the estimated end of PAK life. Chemical analysis of the standard AAMI test panel contaminates to ensure AAMI specifications are met. No other testing is required, such as at a PAK change or with a Control Unit service swap. V595 Each batch, prior to use of the batch. V595 Dialysate Quarterly: Test within the first month of use, near the estimated end of a batch. Analysis of chlorine/chloramines levels to ensure the AAMI and manufacturer s specifications are met. Bacteriological and endotoxin analysis to ensure AAMI specifications are met. Testing Overview

Transitional Care Policies & Procedures Page 3 of 5 Water quality can be confirmed for all new PureFlow SL patients by performing a standard AAMI test panel then comparing each contaminate level to the corresponding PureFlow SL User Guide Section 10: Specifications for Source Water Purity Limits. Source pressure must be between 20-80 psi or 20 to 120 psi with a Pressure Regulator. Source flow must be at least 150ml/min or greater. Results of source may be recorded on Water and Dialysate Testing Log (TM0427) available from NxStage Home Hemodialysis NxDocuments/Forms. TAG# Regulation Interpretive Guidance V593/ V594 / V276 Monitoring of the quality of and dialysate used by hemodialysis patients and testing of the and dialysate system in accordance with: (A) The recommendations specified in the manufacturer s instructions; and (B) The system s FDA approved labeling for preconfigured systems designed, tested, and validated to meet AAMI quality (which includes standards for chemical and chlorine/chloramines testing) and dialysate. A chemical analysis of the product must be done at the start of PureFlow SL treatment and at least once a year near the end of the usability of any disposable component, or when any modifications are made to the treatment components (other than the replacement of disposable components), to ensure that AAMI-defined maximum allowable chemical contaminant levels are not exceeded. When any repairs are made to treatment equipment, the impact on quality should be evaluated and a chemical analysis performed if indicated. Chlorine/chloramine levels must be tested prior to the start of each treatment (or before use of each new batch of dialysate) in accordance with AAMI guidance and manufacturer s recommendations. For batch systems (integrated systems which prepare enough dialysate for multiple treatment), the chlorine/chloramines testing shall be performed at the worst case scenario, i.e. after the preparation of each batch of dialysate, but before use of that batch, from a testing port that meets manufacturer s specifications to be in compliance with the requirements of AAMI.

Transitional Care Policies & Procedures Page 4 of 5 Draw initial product near the estimated end of the first PAK life. Draw annual product near the estimated end of PAK life. Modifications: NxStage will notify user when modifications are made to the system if additional testing of product for chemical analysis should be performed. Repairs: No non-nxstage field repairs are supported by NxStage. Routine service swap of Control Unit provides new or remanufactured equipment following FDA approved Good Manufacturing Practices. Complete self-tests on every PAK and batch ensures proper function of PFSL or the equipment will stop in fail safe condition. Any individual variations in control pressures or flow rate have no impact on purity. New PAK: Testing is NOT required after installing and priming a new PAK. Control Unit Swap: Testing is NOT required after changing the PFSL Control Unit hardware. Sufficient volume of product : PFSL dispenses product from the Conductivity Line of the SAK for initial and repeat chlorine/chloramines testing. The system will automatically go to drain when the operator indicates that the chlorine/chloramines testing has failed. The product used for testing chlorine/chloramines represents the worst case scenario as the samples are representative of the last product entering the batch. Documentation: Documentation of product testing and dialysate sampling may be recorded on the NxStage System One Hemodialysis Flowsheet (TM0196). Results of product and dialysate testing may be recorded on Water and Dialysate Testing Log (TM0427). TAG# Regulation Interpretive Guidance V595 Dialysate The facility must meet testing and other requirements of ANSI/AAMI RD52:2004. In addition, bacteriological and endotoxin testing must be performed on a quarterly or more frequent basis as needed, to ensure that the and dialysate are within the AAMI limits. The result of and dialysate testing for hemodialysis patients may be included in the patients medical records or in separate logs. According to AAMI, a log sheet should be provided by the dialysis facility and used to record all measures of treatment system performance as required by the equipment manufacturer or the dialysis facility

Transitional Care Policies & Procedures Page 5 of 5 Follow appropriate retesting and retraining procedures in response to any positive test results. Dialysate culture should be drawn near the estimated end of SAK life from a sterile connector. Dialysate bacteriology testing does NOT need to be tested before starting treatment. Testing may begin near the end of SAK life. Documentation: Clinicians may record chlorine/chloramines testing results on the (Sample) NxStage System One Hemodialysis Flowsheet (TM196). Clinicians may record and dialysate sampling on the (Sample) NxStage System One Hemodialysis Flowsheet (TM0196). Results of and dialysate testing may be recorded on the Water and Dialysate Testing Log (TM0427). References: CMS 42 CFR Parts 494 Conditions for Coverage for End-Stage Renal Disease Facilities and related CMS ESRD Program Interpretive Guidance (October 3, 2008) Dialysate Preparation Primer Chronic Hemodialysis with the NxStage PureFlow SL PureFlow SL User s Guide AAMI/FDS-RD52:2004/A1 Dialysate for Hemodialysis, Amendment 1- Annex C; Special Considerations for Home Hemodialysis