Series 400 Structural repair system that doubles the strength of the original timber pile. SeaShield Marine Systems. Features

Similar documents
Don't Replace. Restore. Rehabilitation & Stabilization for Marine Facilities & Underwater Structures FIVE STAR PRODUCTS, INC.

Series 2000HD Heavy-duty pile protection system with marine grade petrolatum tape and an HDPE outercover secured with a bolted system

SPECIAL SPECIFICATION 4900 Sacrificial Cathodic Protection Pile Jacket

WEIR PLATES & SCUM BAFFLES

September 1, 2003 CONCRETE MANUAL SPECIAL TYPES OF CONCRETE

Long-term Corrosion Control for Jetty Piles & Marine Structures

FIVE STAR PRODUCTS, INC. (800)

Steel Rehabilitation Resins MIR-940 & MIR-950

LATEST ADVANCES IN PIPELINE RENOVATION WITH FIBER REINFORCED POLYMER (FRP)

Applications (As provided by Avanti International)

1. Cast-in-place concrete is specified in Section

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.

GREEN THREAD Piping Systems

INDUSTRIAL PIPE FITTINGS, LLC

Infrastructure Point Repair System Technical Specifications

Trusted ICC ES. Conformity! Look. Evaluation. ICC-ES Evaluation

***************************************************************************************************************

By CTS Cement Manufacturing Corp.

Author: M Shaw, Sika Limited. Construction. A Guide to the Concrete Repair European Standards BS EN 1504 Series

The Leader in Underwater Piling Repair Technology

TECHNICAL SPECIAL PROVISION FOR CONCRETE REPAIRS. Financial Project ID , &

Rehabilitating Bridge Substructures with FRP Materials

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. March 16,

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

UNI-BELL PVC PIPE ASSOCIATION UNI-B-15-10

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers

SECTION ROLLER GATES

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA

Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe

FIBERGLASS HANDRAIL & LADDER SYSTEMS

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

Construction. Tricosal Waterstops - Tricomer. Waterstops for joint sealing in watertight concrete construction according to DIN and DIN

CTP STITCH-TIE AGAIN! Quick and easy way to re-anchor existing veneers to back-up structures.

Araldite EP 300 A/B High Temperature Adhesive

4 1 /2 MARK 73-5 AMERICAN FLOW CONTROL. It s What We Know. AMERICAN-DARLING FIRE HYDRANT AMERICAN-DARLING 4 1 /2 MARK 73-5 FIRE HYDRANT

LOW VISCOSITY STRUCTURAL EPOXY. Table of Contents. Made in the U.S.A. AF35LVE TECHNICAL DATA SHEET

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

High Strength Epoxy tested in accordance to ICC-ES AC308

Section Soil Erosion Protection Tender No. [ ] Page 1

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,

Section Fluid Applied Waterproofing

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

Installation Practice InnerSeal

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Structural Shapes/Plate and Fabrications REVISED

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

ASLAN 500 CARBON FIBER REINFORCED POLYMER (CFRP TAPES) FOR STRUCTURAL STRENGTHENING COMPOSITE REINFORCING FOR LONG LASTING CONCRETE STRUCTURES

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

Engineering Branch Assets Delivery Group

Restoration and Rehabilitation FRP Wrapping

PLASTERFORM GLASSFIBER REINFORCED GYPSUM (GRG) REV: 4/11

Trusted ICC ES MILAN ITALY SYSTEMS. Look. Conformity! Evaluation. ICC-ES Evaluation

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.

SECTION EPOXY TERRAZZO

SOLAR SHADING SYSTEMS - Manual Solar Shade SECTION ROLLER WINDOW SHADES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Behaviour of Post-Installed GFRP Adhesive Anchors in Concrete

LOCTITE HC AERO

INNOVATIVE FIBRE REINFORCED BRIDGE DECK MODULES ABSTRACT

Diffused Aeration Piping Equipment

High Strength Epoxy Tested in Accordance with ICC-ES AC308

AEC Premier Straw Double Net Quick Mow EROSION CONTROL BLANKET SPECIFICATION

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Pultruded Grating/Treads and Fabrications REVISED

Series 2000PV Mechanical Joint Restraint for PVC Pipe

INIZIATIVE INDUSTRIALI

E.V.A. EXPANSION JOINT SYSTEMS

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

ENGINEERING SPECIFICATION. PULTRUDED PEDESTRIAN FIBERGLASS GRATING SAFE-T-SPAN T1210 VINYL ESTER and ISOPHTHALIC. October 25, 2004 Revision 1

High Strength Epoxy Tested in Accordance with ICC-ES AC308

FIBERGLASS ROUND CONTROL DAMPERS. Model K-RD INTRODUCTION M.K. PLASTICS PROVIDES FOUR DAMPER MODELS K-RD SUGGESTED SPECIFICATION

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

TOPCOAT System Specifications Corrugated Transite Panels

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

SECTION EXPANSION CONTROL

SECTION EPOXY FLOORING SYSTEMS

Construction. Injectable hose for sealing construction joints in watertight structures. Product Description. Product Data. Tests.

Wall Modular Block Mechanically Stabilized Earth, Item S.

DIVISION 9 FINISHES Section Floor Finishes

Section [ ] Stormwater Catch Basin Filtration Device

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

TAMDID PIPES GRP MANHOLE BROCHURE

Advantages of Incorporating Fiber Reinforced Polymers into the Earthquake Safety Program for the Bay Area Rapid Transit (BART)

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

CERTIFIED. The Global Leader In Innovative Geotechnical Applications Using Synthetic Sheet Piling

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 5 REINFORCING STEEL. 5.1 General Certification Fabrication...

FRP Repair to a Reinforced Concrete Chimney

Curlex High Velocity EROSION CONTROL BLANKET SPECIFICATION

Attachment A-Flagpole(s) Specifications

Joining & Bonding of Composite Parts The Structural Adhesive Advantage

Technical Data Sheet: The Corrugated HC-Omega

PRECAST PRESTRESSED CONCRETE PAVEMENT SECTION 509, AFTER LINE 285, INSERT AS FOLLOWS: SECTION PRECAST PRESTRESSED CONCRETE PAVEMENT

ZZ-M-71F February 26, 1987 SUPERSEDING ZZ-M-71E May 3, 1979 FEDERAL SPECIFICATION MATTING, RUBBER AND VINYL

Elastomeric Protected Membrane Roofing Fluid-Applied Protected Membrane Roofing. Restoration Coating System (RCS) over Cap Sheet

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for LIQUEFIED NATURAL GAS (LNG) CRYOGENIC REFRIGERATION CHILLED WATER

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

Curlex II EROSION CONTROL BLANKET SPECIFICATION

SECTION REINFORCING STEEL

SECTION POLYVINYL CHLORIDE (PVC) WATERLINE

Transcription:

SeaShield Marine Systems The SeaShield Series 400 System has been independently tested by Texas A&M University, Department of Civil Engineering, Structural and Materials Testing Laboratory. Features Provides double the strength of the original timber pile Non-corrosive reinforcement Series 400 Structural repair system that doubles the strength of the original timber pile Reduced weight when compared to steel reinforcement Requires inexpensive pumping equipment Flowable non-shrink grout Manufactured to be translucent with clear gel coat High impact resistance UV resistant S Long maintenance-free service life eashield Series 400 System is comprised of the SeaShield Fiber-Form Jacket, C-GRID 450 and SeaShield 510 UW Grout or SeaShield 550 Epoxy Grout. The Series 400 is a revolutionary encapsulation system that not only protects timber piles from aggressive saltwater environments and marine borers, but also strengthens deteriorated piles with a durable, lightweight and non-corrosive reinforcement.

The lightweight and non-corrosive C-GRID 450 is installed around the pile. The SeaShield Fiber-Form jacket is then snapped in place around the C-GRID 450. Grout can be pumped as soon as the SeaShield Fiber-Form jacket is secured in place. SeaShield Series 400 System The SeaShield Series 400 System is comprised of a SeaShield Fiber-Form Jacket, C-GRID 450, and either SeaShield 510 UW Grout or SeaShield 550 Epoxy Grout. The complete system doubles the strength of the original timber pile. The C-GRID 450 should be unrolled and cut using tin snips or other suitable method. The cut width of C-GRID 450 is determined by including enough material to be imbedded within the grout and a 6" overlap along vertical seam. Locate the C-GRID 450 between the elevations indicated in the specification and drawings. Then, the SeaShield Fiber-Form Jacket is installed around the pile and C-GRID 450. A foam seal should be installed at the bottom of each jacket to prevent any grout from leaching out of the bottom of the jacket during in- stallation. Once jacket is in place, inject grout approximately 6" to 12" into the bottom port and allow it to cure before proceeding with subsequent lifts. The injection process should be continuous, except when the injection hose is moved from port to port. For further information please refer to the technical data sheets for the SeaShield Fiber-Form Jacket, C-GRID 450 and SeaShield 510 UW Grout or SeaShield 550 Epoxy Grout. Complete details can be found on the SeaShield Series 400 Engineering Specifications. C-GRID 450 utilized by Denso North America in the SeaShield Series 400 System is protected under the following US and European Patents: 6,263.629; 5836,715; 6,123,879;6,454.889;6,632,309;0861353;1094171. C-GRID is registered trademark of Chomarat North America, LLC. SeaShield 510 UW Grout or SeaShield 550 Epoxy Grout C-GRID 450 Tongue-andgroove closure HOUSTON: 9747 Whithorn Drive, Houston, Texas, U.S.A. 77095 Tel: 281-821-3355 Fax: 281-821-0304 TORONTO: 90 Ironside Crescent, Unit 12, Toronto, Ontario, Canada M1X1M3 Tel: 416-291-3435 Fax: 416-291-0898 e-mail: info@densona.com Fiber-Form Jacket SS 400 VER 109.1 www.densona.com A Member of Winn & Coales International

Engineering Specifications for SeaShield Series 400 Timber Pile Rehabilitation 1.0 Scope 1.1 This specifi cation may be used for the materials and application of SeaShield Series 400 Timber Pile Rehabilitation System. 1.2 The engineer shall select appropriate sections of the specifi cations to ensure that the specifi cation is comprehensive for specifi ed work. 2.0 General Requirements 2.1 Contractor shall comply with all written recommendations of the manufacturer regarding application of the specifi ed system. 2.2 The manufacturer of specifi ed materials shall be Denso North America, 9747 Whithorn Drive, Houston, TX 77095, Tel: 281-821-3355 or 90 Ironside Crescent, Unit 12, Toronto, Ontario, Canada M1X1M3 Tel: 416-291-3435. E-mail: info@densona.com 2.3 All materials used to comprise the SeaShield Series 400 System must be purchased from the same manufacturer. These include SeaShield Fiber-Form Jackets, C-GRID 450, SeaShield 525 Epoxy, and either SeaShield 510 UW Grout (Cementitious) or SeaShield 550 Epoxy Grout. 3.0 Materials 3.1 Fiberglass Jacket (SeaShield Fiber-Form) 3.1.1 The fi berglass jacket thickness shall be a minimum of 1/8 inch (3 mm) constructed of layers of woven roving and mat. 3.1.2 The jacket shall be translucent to provide visual inspection during the injection of the grout. 3.1.3 The jacket shall have minimum one inch injection ports spaced at intervals not to exceed fi ve feet. To provide even distribution of the grout, the injection ports shall be placed on alternate sides. 3.1.4 The jackets shall have adjustable stand-offs inserted through the jacket to maintain the specifi ed annulus between the pile and the jacket. A UV gel coat shall be applied to the outside of the completed fi berglass jacket. 3.1.5 The fi berglass jackets shall have the following properties: Ultimate Tensile Strength ASTM D638 15,000 PSI IZOD Impact Strength ASTM D256 20 ft.-lbf/in. Barcol Hardness ASTM D2583 35 Water Absorption ASTM D570 1% Max UV Stability ASTM G23 500 Hr. Pass 3.1.6 The fi berglass jacket may be manufactured as either a single unit or as two pieces that shall be joined in the fi eld. The jackets can be placed one above the other via bell and spigot. 3.2 Carbon-Fiber Grid 3.2.1 The Carbon-Fiber Reinforcement shall be C-GRID 450 as provided by Denso North America. 3.2.2 Please refer to the C-GRID 450 data sheet for complete property specifi cations. 3.2.3 All C-GRID 450 shall be stored in a sheltered area to prevent degradation of the epoxy resin due to UV exposure. 3.3 Grout 3.3.1 The grout shall consist of either SeaShield 510 UW (Cementitious) Grout or SeaShield 550 Epoxy Grout as manufactured by Denso North America. For detailed grout specifi cations, please refer to the SeaShield 510 UW (Cementitious) Grout or SeaShield 550 Epoxy Grout product data sheets. 3.3.2 All grout shall be stored in a sheltered area away from rain and water. 3.4 Marine Epoxy 3.4.1 The SeaShield 525 Epoxy shall be used

to adhere the fi berglass vertical seams. The 525 Epoxy may also be used to fi nish the tops of the encapsulation. 4.0 Equipment 4.1 The grout shall be pre-mixed and pumped through a peristaltic pump or other suitable pump. The equipment shall be capable of delivering mixed grout through hoses into the jackets at a rate 1 GPM or greater. 4.2 Prior to using the pump, all lines shall be primed by circulating 1 gallon of the SeaShield Hose Lubricant. 5.0 Surface Preparation 5.1 Prior to application, thoroughly clean and remove marine growth, oil, grease and any other deleterious material which might prevent proper bonding between the pile and grout. Surface preparation shall be accomplished by water blasting to provide a clean surface. 6.0 Installation 6.1 Installation of C-GRID 450 and Fiberglass Jacket 6.1.1 The inside surface of the jacket shall be lightly roughened to remove residue and contamination. 6.1.2 Adjustable stand-offs shall be inserted through the jacket at 18" to 48" intervals (depending on diameter size, length and thickness of jacket) along entire length of jacket. 6.1.3 All longitudinal and transverse seams shall be sealed with SeaShield 525 Epoxy as described in Section 3.3.1 and fastened with 3/16" diameter stainless steel hex screws that shall not exceed 6" spacing. 6.1.4 The C-GRID 450 shall be unrolled and cut using tin snips or other suitable method. The cut width of C-GRID 450 shall be determined by including enough material to be imbedded within the grout and a 6 overlap along vertical seam. The grid will require a minimum of ¼" grout cover. 6.1.5 Locate the C-GRID 450 between the elevations indicated in the specifi cation and drawings. The C-GRID 450 shall be wrapped around the timber pile with a minimum 6" overlap along the vertical seam. Use nylon zip ties, plastic clips or other plastic accessories to secure vertical seam and maintain the position of the grid during the pumping of grout. On long length repairs which require more than one panel of grid, the C-GRID 450 shall be overlapped 6" above or below the fi rst panel of grid. 6.1.6 The fi berglass jacket shall be installed around the pile and C-GRID 450. The jacket shall be supported by temporary nylon straps or other means to assure that the jacket or C-GRID 450 will not move or distort during placement of grout. 6.1.7 A foam seal shall be installed at the bottom of each jacket to prevent any grout from leaching out of the bottom of the jacket during installation. A ratcheting strap shall be placed on outside of jacket to compress the foam seal. 6.2 Grout Placement 6.2.1 Once jacket is in place, inject grout approximately 6" to 12" into the bottom port and allow it to cure before proceeding with subsequent lifts. 6.2.2 Grout injection shall begin at the bottom injection port and proceed upwards. As the jacket is fi lled to each port, the lower port shall be capped off and repeated until the top of the jacket is reached. 6.2.3 The injection process shall be continuous, except when the injection hose is moved from port to port. 6.3 Completion 6.3.1 After the injection process is completed and the epoxy grout has cured, all temporary supports shall be removed. 6.3.2 The top of each fi berglass jacket may be fi nished with the SeaShield 525 Epoxy described in Section 3.4.1. C-GRID 450 utilized by Denso North America in the Sea- Shield Series 400 System is protected under the following US and European Patents: 6,263.629; 5836,715; 6,123,879;6,454.889;6,632,309;0861353;1094171. C-GRID is registered trademark of Chomarat North America, LLC. HOUSTON: TORONTO: 9747 Whithorn Drive, 90 Ironside Crescent, Houston, Texas, Unit 12, Toronto, U.S.A. 77095 Ontario, Canada M1X1M3 Tel: 281-821-3355 Tel: 416-291-3435 Fax: 281-821-0304 Fax: 416-291-0898 www.densona.com A Member of Winn & Coales International VER 109.1

Elevation View SeaShield Series 400 Detail Drawing Sheet 1 (Not to Scale)

Step 1 Position SeaShield Fiber- Form Jacket around pile/ C-GRID 450 and seal longitudinal seams. Step 2 Affi x bottom seal gasket with select strapping. Step 3 Connect grout hose to lower injection port and pump SeaShield 510 UW Grout or SeaShield 550 Epoxy Grout. Visually check for leaks. Plug upper port(s) and pump grout until it reaches top of jacket. (Upper ports are used only if pumping from lower ports becomes diffi cult.) Step 4 (Alternate Pumping Method) Contractor may choose to inject approximately 6" of SeaShield 510 UW Grout or SeaShield 550 Epoxy Grout and let cure before moving grout hose to next higher port and pumping remainder of grout. Pumping would then continue until grout reaches top of jacket. Cured SeaShield 510 UW Grout or SeaShield 550 Epoxy Grout Sheet 2 (Not to Scale) SeaShield Series 400 Grout Placement Sequence VER 109.1

P R O D U C T D A T A S H E E T C-GRID 450 Carbon-Fiber Grid for Strengthening Timber Piles Description C-GRID 450 is a high strength carbon-fiber/epoxy grid for structural repairs of timber piles. The C-GRID 450 requires less grout fill leading to a much lighter structure when compared to typical steel reinforced repairs. The composition is carbon-fi ber and epoxy resin. The C-GRID 450 geometry is longitudinal and transverse spacing (2.36" x 2.36"). Features Provides double the strength of the original timber pile Reduced weight when compared to steel reinforced repairs Non-corrosive (no steel to corrode) Lightweight and easy to install High tensile strength and modulus Requires much less grout when compared to steel reinforcement repair Requires only 1/4" grout cover Grid has excellent bond to grout Independently tested by Texas A&M University, Department of Civil Engineering, Structural and Materials Testing Laboratory Installation The C-GRID 450 shall be unrolled and cut using tin snips or other suitable method. The cut width of C-GRID 450 shall be determined by including enough material to be imbedded within the grout and a 6" overlap along vertical seam. The grid will require a minimum of ¼" grout cover. Locate the C-GRID 450 between the elevations indicated in the specification and drawings. The C-GRID 450 shall be wrapped around the timber pile with a minimum 6" overlap along the vertical seam. Use nylon zip ties, plastic clips or other plastic accessories to secure vertical seam and maintain the position of the grid during the pumping of grout. On long length repairs which require more than one panel of grid, the C-GRID 450 shall be overlapped 6" above or below the first panel of grid. The fi berglass jacket shall be installed around the pile and C-GRID 450. Please refer to the SeaShield Series 400 Engineering Specifications for complete installation guidelines.

C-GRID 450 Property Specifications PROPERTIES LONGITUDINAL PROPERTIES TRANSVERSE PROPERTIES Individual strand cross-sectional area 0.00321 in. 2 (2.07 mm 2 ) 0.00321 in. 2 (2.07 mm 2 ) Average number of strands per unit width 5.0 strands/ft (16.6 strands/m) 5.0 strands/ft (16.6 strands/m) Area of strands per unit width 0.0241 in. 2 /ft. (50.9 mm 2 /m) 0.0241 in. 2 /ft. (50.9 mm 2 /m) Strand tensile strength 830 lbs (3.7 kn) 730 lbs (3.2 kn) Grid tensile strength per unit width 4565 lbs/ft (66.4 kn/m) 4015 lbs/ft (58.4 kn/m) Tensile modulus of elasticity 34,000 ksi (234,500 MPa) 34,000 ksi (234,500 MPa) Elongation at break 0.99% (0.99%) 0.94% (0.94%) Notes: 1. Centerline-to-centerline spacing between strands is nominal and based on the average number of strands per unit width. Actual spacing may vary by ± 0.10 inch (± 2.5 mm). 2. The longitudinal direction is in the direction of the roll and the transverse direction is across the width of the roll. For example, if a roll of C-GRID 450 is 47.5" wide the carbon strands in the transverse direction are 47.5" in length. If a roll of C-GRID 450 is 500 yards long, the longitudinal strands are 500 yards in length. 3. Individual strand cross-sectional area is normalized to the cross-sectional area of the fibers in accordance with ACI 440.2R. The actual measured thickness and width are larger and shall not be used for design purposes. 4. Reported tensile strengths are typical or average properties based on testing. Tensile modulus values are based on properties reported by the carbon fiber supplier. C-GRID 450 exhibits linear elastic behavior so failure strains are estimated using Hooke s Law. 5. C-GRID 450, utilized by Denso North America in the SeaShield Series 400 System, is protected under the following US and European Patents: 6,263.629; 5836,715; 6,123,879;6,454.889;6,632,309;0861353;1094171. C-GRID is registered trademark of Chomarat North America, LLC. HOUSTON: TORONTO: 9747 Whithorn Drive, 90 Ironside Crescent, Houston, Texas, Unit 12, Toronto, U.S.A. 77095 Ontario, Canada M1X1M3 Tel: 281-821-3355 Tel: 416-291-3435 Fax: 281-821-0304 Fax: 416-291-0898 www.densona.com A Member of Winn & Coales International The information given on this sheet is intended as a general guide only and should not be used for specifi cation purposes. We believe the information to be accurate and reliable but do not guarantee it. We assume no responsibility for the use of this information. Users must, by their own tests, determine the suitability of the products and information supplied by us for their own particular purposes. No patent liability can be assumed. VER 109.1