DEPARTMENT OF BIOLOGICAL SCIENCES MEDICAL/BIOHAZARDOUS WASTE DISPOSAL AUTOCLAVE TRAINING

Similar documents
PROGRAM FOR THE MANAGEMENT AND DISPOSAL OF RADIOACTIVE WASTE

Biomedical Waste Management Guide

LABORATORY WASTE MANAGEMENT PROGRAMMES

Health Sciences Campus Biomedical Waste Management Standard Operating Procedure (SOP)

Medical, Pathological and Low-level Radioactive Waste Management Plan for Incinerator Revised 3-08

BIOMEDICAL WASTE MANAGEMENT POLICY

EH&S. Sheet. Fact. Safe and Effective Use of Autoclaves. What are autoclaves? Factors for effective sterilization. Dry heat cycle - when to use

Employee Environmental, Health & Safety Manual. INFECTIOUS WASTE MANAGEMENT PROGRAM Latest Revision: 05/27/08

INFECTIOUS/BIOLOGICAL WASTE MANAGEMENT PROTOCOL

Safe Operating Procedure

University Health Services Health and Safety

Regulated Medical Waste Management and Proper Waste Segregation. State-Specific Information Florida

Biological Materials and Biohazardous/Medical Waste Disposal Program

AREAS OF RESPONSIBILITY

SEB Autoclave Training

You are required to complete this course with a passing score of 85% or higher if you:

Biomedical Waste Management Plan

Biosafety Protocol. Biodesign Swette Center for Environmental Biotechnology Standard Operating Procedures

DOT Hazardous Materials and Regulated Medical Waste Prepared By: George Weishoff

B. The Facility Manager is responsible for ensuring all staff are adequately trained and experienced in autoclave sterilization procedures.

CHAPTER 31 BIOMEDICAL WASTE. by George F. Indest III, JD, MPA, LL.M SCOPE

OREGON HEALTH & SCIENCE UNIVERSITY RADIATION SAFETY OPERATING PROCEDURE 1801 RADIOACTIVE WASTE HANDLING & STORAGE

Biohazardous/Medical Waste Management and Sharps Procedures

Biosafety Level 2 (BSL-2) Laboratory Guidelines

THE SAFE DISPOSAL OF CLINICAL/DOMESTIC WASTE

Procedure for Health Care Risk Waste Management. Procedure No. 403

BIOMEDICAL WASTE PLAN Health Sciences Campus / Biological Sciences Titusville Campus

Development of a New Classification and Colour Code for Medical Waste Segregation

University Health Services Health and Safety REGULATIONS FOR AUTOCLAVE USE, MAINTENANCE AND RECORDKEEPING

Regulated Medical Waste Management and Proper Waste Segregation. State-Specific Information California

MODEL EXPOSURE CONTROL PLAN

Waste Disposal Procedures (EHS Program 5.2)

UNIVERSITY OF TOLEDO HEALTH SCIENCE CAMPUS

Guidelines for the Use of Cytotoxic or Chemotherapeutic Drugs

For ethidium bromide waste that is generated at Harvard, each waste stream is to be managed or accumulated as described below.

PROGRAM FOR THE MANAGEMENT AND DISPOSAL OF BIOHAZARDOUS WASTE

Regulated Medical Waste Management and Proper Waste Segregation. State-Specific Information New Jersey

BOWDOIN COLLEGE BIOMEDICAL WASTE MANAGEMENT PLAN

Standard Microbiological Practices

LABORATORY SAFETY EVALUATION. S = Satisfactory N = Needs Improvement* N/A = Not Applicable

PURE CULTURE TECHNIQUES

MEDICAL WASTE MANAGEMENT STUDY NOTES

Bloodborne Pathogens Exposure Control Plan

Clinical Waste. Policy. Responsibilities

Performance-Based Inspection Field Guide

Legal Aspects and Process of Biomedical Waste Management Practices in India. *Prakash V **Dr. N. Palaniraj

GUIDELINES FOR SHIPPING NONPATHOGENIC BIOLOGICAL CULTURES AND NON-INFECTIOUS BIOLOGICAL MATERIALS

Inspection Checklist for NIH BL3 Laboratories (7 CFR 331; 9 CFR 121; 42 CFR 73; NIH Guidelines)

Last Revised: 1/2018 Prior Version: 12/2014 SOP NUMBER: SC-402 Page 1 of 9

BIOSAFETY GUIDELINES BACKGROUND ON BIOSAFETY

Special Specimen Collection Procedures for Coagulation Testing

COMPLETE COMPLIANCE CHECKLIST

BIOMEDICAL WASTE FACILITY INSPECTION REPORT* Facility name: Permit #: Date of Inspection:

Safe Operating Procedure

Laboratory Research Ethics, Conduct and Safety

Departmental Exposure Control Plan

Biomedical Waste Handling and Disposal

Human DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure

Standard Operating Procedure. Handling of Radioactive Material. PC-SOP-IM-005-v02

SAFETY MANUAL OF GOOD LABORATORY

ASEPTIC TRANSFER & PURE CULTURE TECHNIQUES

Approved by CAC Board August 18, 2011

LABORATORY CLOSURE AND DECOMMISSIONING POLICY

Biology Lab Safety. Document No Audit Title Biology Lab Safety Inspection. Conducted on 9/28/16, 1:43 PM

Asbestos in the Home

Appendix B. Sanitation Performance Standards

INTRODUCTION TO THE PROGRAM

MODULE 14: Off-site Transport and Storage of Healthcare Waste

Laboratory (LAB) prepares sample kits prior to Epidemiologist Investigator (EPI) arrival.

transport of biological materials

Health Care Waste Management - To Reduce the Burden of Disease, Health- Care Waste Needs Sound Management, Including Alternatives to Incineration

SPECIAL WASTE CONTAINERS

TRANSFER OF BACTERIA USING ASEPTIC TECHNIQUE

Disposal of biological waste from containment level 2 laboratories in the WIMM

Working with blood and human tissues Code of Practice. Hatchcroft Laboratories - Middlesex University

Material Safety Data Sheet

Sterilization & Disinfection

"ASBESTOS AWARENESS IN THE WORKPLACE"

8.0 Radioactive Waste

1060 Holland Dr: Suite A Boca Raton, FL Nationwide: (877) Local: (561) Fax: (561)

Safety and Health Policy and Procedure Manual. Biological Safety Manual Section 280

Sample for use a Guide Revised IDEXX COLILERT -18 TEST METHOD FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND E.

F2. Vehicle and Heavy Equipment Repair and Maintenance

Manatee County Sheriff s Office PROPERTY AND EVIDENCE

Maxwell RSC Blood DNA Kit

Specialty Testing of Steam Sterilizers

To Pesticide Use Around the Home and Garden

Handling Hazardous Waste

Completing. By the end of this chapter, you will be able to: Introduction. Chapter 16

Maxwell RSC Whole Blood DNA Kit

Swette Center for Environmental Biotechnology Radiation Safety Policy

General Guidelines for Users and Visitors to NTU. Animal Research Facility

Revised 27 Aug rm (Vers. 4.1)

If location of the facility is within an urban

Managing Hazardous Chemical Waste

Fairview Freezer Facility Policy September Shared Resources &Facilities Engineering

A Critical Review of Rentokil Initial s Plus by Initial Service for the Treatment, Handling, Collection and Transport of Sanitary Waste

Copyright 2017 Aegis Sciences Corporation All Rights Reserved

Environmental Guideline for. Biomedical and Pharmaceutical Waste

Transcription:

DEPARTMENT OF BIOLOGICAL SCIENCES MEDICAL/BIOHAZARDOUS WASTE DISPOSAL AUTOCLAVE TRAINING

INTRODUCTION In accordance with the California Medical Waste Management Act, Health and Safety Code Stanford University generates, processes and disposes of medical waste as a distinct entity. In the past, medical waste was defined as hazardous waste containing a disease bearing organism. As a result of this new law, Stanford University must properly segregate medical waste at the point of origin and document handling prior to disposal. The methods of disposal of Department of Biological Sciences medical/biohazardous waste will be discussed in detail during this class.

DEFINITION OF MEDICAL WASTE Medical Waste is defined as follows: Biohazardous Waste Sharps Waste BIOHAZARDOUS WASTE Biohazardous/Medical waste is defined as including, but not limited to the following: Laboratory Waste from the production of bacteria, viruses, or the use of spores, discarded live and attenuated vaccines, and culture dishes and devices used to transfer, inoculate and mix cultures that normally causes or significantly contributes to the cause of morbidity or mortality of human beings. Microbiological specimen waste Infected pathological waste (both human and animal)

Waste containing recognizable fluid blood BL2 levels of waste SHARPS WASTE Sharps waste means any device having acute Rigid corners capable of cutting or piercing Including the following: hypodermic needles, blades, and syringes with needles or biohazardous materials Glass items such as Pastuer pipettes and blood vials contaminated with biohazardous waste NON-MEDICAL WASTE Waste generated that does not contain an infectious agent. Waste that does not contain human blood or blood products Or animal blood or blood products suspected of being Contaminated with infectious agents known to be communicable to Humans. Urine, feces, saliva, sputum, nasal secretions, sweat, tears or vomitus, unless it contains fluid blood

RESPONSIBILITIES OF THE RESEARCH LABORATORY Segregate medical waste from the point of generation and from other waste streams Insure that workers are trained in the proper disposal of medical waste PRIOR to the commencement of experimental work Use the proper medical waste packaging materials for sharps and autoclave waste RESPONSIBLITIES OF THE DEPARTMENT OF BIOLOGICAL SCIENCES Ensure that autoclaves are properly maintained. Ensure that adequate maintenance testing records are being maintained Ensure that medical waste management plan and permit are update annually and kept on file for review

PROPER LIQUID BIOHAZARDOUS WASTE DISPOSAL For all known infectious blood or known Biohazardous liquid fluids: Treat with 10% bleach or autoclave Pour down sanitary sewer PROPER DISPOSAL OF ANIMAL CARCASSES Place in red bag Transport to RAF storage freezer DO NOT PUT IN AN AUTOCLAVE BAG OR THE REGULAR TRASH PROPER DISPOSAL OF SHARPS WASTE

Place in red, hard plastic container Do not autoclave sharps containers Ensure that the sharps container will be disposed of as red bag waste SHARPS CONTAINERS MUST NOT BE DISPOSED OF IN THE REGULAR TRASH! PROPER DISPOSAL OF NON CONTAMINATED PLASTIC PIPETTES AND SYRINGES Plastic Pipettes and pipet tips may be disposed of in the regular trash Non-contaminated plastic syringes WITHOUT NEEDLES may also be Disposed of in the regular trash PROPER DISPOSAL OF MIXED WASTE Waste containing biological and chemical waste must be handled as

Chemical Waste Waste containing both biological and radioactive waste must be treated as Radioactive Waste AUTOCLAVE HAZARDS Steam Leaks Hot metal surfaces Implosion risk Hot liquid boil over Pre-cycle bioharzards Shattered glass SAFETY CONSIDERATIONS FOR AUTOCLAVE ATTENDENTS Use heat resistant gloves, goggles and other protective clothing

DO NOT OVERLOAD any containers or bags which are put in the autoclave Never place tightly sealed containers in an autoclave Never autoclave volatile chemicals or radionuclides Use caution in opening the hatch Never lift an autoclave bag from the bottom in case sharps or broken glass may be present Use caution when autoclaving pressurized containers. Lightly cover such glassware. Check glassware for cracks prior to cycle. PROPER AUTOCLAVE BAG PACKAGING Bag should be clear, not red Bag must not be over packed Bag should be loosely secured with indicator tape Bag must not contain loose sharps

AUTOCLAVE LOADING Never autoclave anything directly on the floor of the autoclave Use a rack and autoclave proof plastic trays Never overpack the autoclave so that material brushes against a metal surface (which is super-heated during the cycle) DRY LOADS Allow time for cool-down period Place dry loads in racks or grids. If foil wraps are used, allow for a steam path Water accumulation on trays degrade the effectiveness of the dry cycle Glassware should contain a small amount of

water to expedite the decon process WET LOADS COOL DOWN PERIOD IS MANDATORY! Avoid the use of boiling stones in autoclave liquids Flasks must be no more than 2/3 full to prevent boil-over use eyewash/deluge shower if scalded by hot autoclaved liquids AUTOCLAVE PRE-START PROCEDURES Be sure to wear gloves and safety equipment Check gasket seat for cleanliness Check the door gasket for cracks and fraying Load run on trays Do not rely on autoclave signals

AUTOCLAVE OPERATIONAL CONSIDERATIONS Keep safety equipment clean and available IN THE EVENT OF AN ABOTED RUN DO NOT OPENT THE AUTOCLAVE OR LOOK INTO THE HATCH! Label cooling materials with a Caution, Hot! sign OTHER AUTOCLAVED WASTE CONSIDERATIONS Not all clear bags are autoclavable Never autoclave a clear bag with recognizable fluid blood. This bag must be handled as biohazardous wste Never autoclave a clear bag with animal waste. The animal carsasses go in a red bag

RECORDKEEPING Autoclaves must be tested and documented on a monthly basis with the indicator organism, bacillus stearothermophilus. A written SOP must be filed for biological indicators and the autoclave procedures Calibrated thermometer records must be kept for one year. CONCLUSION The Department of Biological Sciences generates a variety of waste. Because of current laws, we must make every effort to properly segregate and dispose of medical waste. The use of the autoclave must also be consistent with the Medical Waste Management Act.